• Title/Summary/Keyword: reference range

Search Result 1,777, Processing Time 0.025 seconds

Papers : Transonic Wing Planform Design Using Multidisciplinary Optimization (논문 : 다분야 통합 최적설계 기법을 이용한 날개 기본 형상 설계)

  • Im,Jong-U;Gwon,Jang-Hyeok
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.30 no.1
    • /
    • pp.20-27
    • /
    • 2002
  • Aircraft design requires the intergration of several disciplines, inculding aerodynamics, structures, controls. To achieves advances in performance, each technology, or discipline must be more accurate in analysis and must be more highly intergrated. One of the important interdisciplinary interactions in mordern aircraft design is that of aerodynamics and structures. In this study, for increasing accuracy in each discipline's analysis, CFD for aerodynamic analysis and FEM for structurral analysis was used and, for considering important interdisciplinary interactions, aeroelastic effect was considered. As optimization algorithm, PBIL algorithm was used for global optima and was parallelized to alleviate the computational burden. The efficiency and accuracy of the present method was assesed by range maximiziation of reference of reference wing.

Event-specific Detection Methods for Genetically Modified Maize MIR604 Using Real-time PCR

  • Kim, Jae-Hwan;Kim, Hae-Yeong
    • Food Science and Biotechnology
    • /
    • v.18 no.5
    • /
    • pp.1118-1123
    • /
    • 2009
  • Event-specific real-time polymerase chain reaction (PCR) detection method for genetically modified (GM) maize MIR604 was developed based on integration junction sequences between the host plant genome and the integrated transgene. In this study, 2 primer pairs and probes were designed for specific amplification of 100 and 111 bp DNA fragments from the zSSIIb gene (the maize endogenous reference gene) and MIR604. The quantitative method was validated using 3 certified reference materials (CRMs) with levels of 0.1, 1, and 10% MIR604. The method was also assayed with 14 different plants and other GM maize. No amplification signal was observed in real-time PCR assays with any of the species tested other than MIR604 maize. As a result, the bias from the true value and the relative deviation for MIR604 was within the range from 0 to 9%. Precision, expressed as relative standard deviation (RSD), varied from 2.7 to 10% for MIR604. Limits of detections (LODs) of qualitative and quantitative methods were all 0.1%. These results indicated that the event-specific quantitative PCR detection system for MIR604 is accurate and useful.

Bioequivalence Study of Ranitidine Tablet

  • Shim, Chang-Koo;Hong, Jae-Sung;Lee, Chang-Ki;Han, Ik-Soo;Choi, Kwang-Sik
    • Archives of Pharmacal Research
    • /
    • v.13 no.2
    • /
    • pp.180-186
    • /
    • 1990
  • A bioequivalence study of ranitidine tablets was conducted according to the Korean Guidine for the Bioequivalence Test using twelve healthy male subjects. The plasma concentration-timecurves of ranitidine from the test and reference tablets showed profound multiple peak phenomenon in each subject as reported earlier. However, the area under the plasma concentration-time curve (AUC) and the maximum ploasma concentration at the first peak ($C_{max1}$) of the two preparations was proven to be equal when analyzed satistically according to the criteria of the guidline;i. e., statistical power (1-$\beta$)was calculated to be over 0.8 under the condition of $\alpha$ = 5% and $\Delta$(minimum detectable difference) = 20%, and the confidence interval of the difference in AUC at 95% confidence level was in the range of $\pm$ 20%, which statisfied the criteria of bioequivalence. Equivalence of the peak concentration of ranitidine at the second peak ($C_{max2}$), and the time to reach the first ($T_{max1}$) and second verify the bioequivalence of $c_{max2}$ , $T_{max1}$ and $T_{max2}$ between the two tablets. However, we conclude that the test and reference tablets are bioequivalent taking the therapeutic characteristics of the ranitidine preparations into consideration.

  • PDF

A Study on the Damage Design of Military Aircraft Structure Material by Armor Piercing Bullet Hit (철갑탄 피격에 의한 군용 항공기 구조재료의 손상설계에 관한 연구)

  • Hur, Jang-Wook;Hyun, Young-Jin
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.13 no.6
    • /
    • pp.1051-1057
    • /
    • 2010
  • Database for the damage reference by armor piercing bullet test was established for both tube and plate specimens having a range of thickness. As the inclined angles of hit are increasing, it has been found that penetration damage diameter tends to increases accordingly in both specimen of the tube and plate, and such penetration damage diameter on the rear side becomes bigger than those on the front side. The tube specimen showed that the damage becomes bigger when central areas rather than the peripheral were hit. Through the plate test, it also has been found that the penetration ballistic limit for Al alloy is about 25.4mm and that of stainless steel about 12.7mm. From the fatigue analysis results using the database for damage reference, it has been identified whether the safety requirements of military aircraft could be met.

Angle Sensors Based on Oblique Giant Magneto Impedance Devices

  • Kim, Do-Hun;Na, Ji-Won;Jeung, Won-Young
    • Journal of Magnetics
    • /
    • v.14 no.1
    • /
    • pp.42-46
    • /
    • 2009
  • The measurement of external magnetic field orientation using Giant Magneto Impedance (GMI) sensors has been performed. A soft magnetic alloy of $Co_{30}Fe_{34}Ni_{36}$ was electroplated on a Si wafer with a CoFeNi seed layer. V-shaped microwire patterns were formed using a conventional photolithography process. An external magnetic field was generated by a rectangular AlNiCo permanent magnet. The reference direction was defined as the external magnetic field direction oriented in the middle of 2 GMI devices. As the orientation of the magnetic field deviated from the reference direction, variation in the field component along each device introduced voltage changes. It was found that, by taking the voltage difference between the left and right arms of the Vshaped device, the nonlinearity of each device could be significantly reduced. The fabricated angle sensor had a linear range of approximately $70^{\circ}$ and an overall sensitivity of approximately 10 mV.

VCO Nonlinearity Correction Scheme for a FM-CW Radar using a Reference Signal (기준 신호를 이용한 FM-CW 레이더의 VCO 비선형성 보정)

  • 박형근;김병욱;김영수
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.10 no.7
    • /
    • pp.1104-1110
    • /
    • 1999
  • When a FM-CW radar is used to measure the target distance, the nonlinearity relationship between the VCO control voltage and the output frequency makes an adverse effect on the measurement accuracy. Recently, many nonlinearity correction schemes using signal processing techniques and dedicated hardwares have been studied. This paper presents a signal processing technique to compensate for the VCO nonlinearity using a reference signal. To demonstrate the validity of the presented technique, several experiments were conducted and the results show reduction of the distortion in the range profile and the resolution improvement.

  • PDF

Solid-State $CO_2$ Sensor using ${Li_2}{CO_3}-{Li_3}{PO_4}-{Al_2}{O_3}$ Solid Electrolyte and ${LiMn_2}{O_4}$ as Reference Electrode (${Li_2}{CO_3}-{Li_3}{PO_4}-{Al_2}{O_3}$계의 고체 전해질 및 ${LiMn_2}{O_4}$의 기준전극을 사용한 $CO_2$ 가스센서)

  • 김동현;윤지영;박희찬;김광호
    • Journal of the Korean Ceramic Society
    • /
    • v.37 no.8
    • /
    • pp.817-823
    • /
    • 2000
  • A solid-state electrochemicall cell for sensing CO2 gas was fabricated using a solid electrolyte of Li2CO3-Li3PO4-Al2O3 mixture and a reference electrode of LiMn2O4. The e.m.f. (electromotive force) of sensor showed a good accordance with theoretical Nernst slope (n=2) for CO2 gas concentration range of 100-10000 ppm above 35$0^{\circ}C$. The e.m.f. of sensor was constant regardless of oxygen partial pressure at the high temperature above 0.1 atm. It was, however, a little depended on oxygen partial pressure as the pressure decreased below 0.1 atm. The oxygen-dependency of our sensor gradually disappeared as the operating temperature increased. The sensing behavior of our CO2 sensor was affected by the presence of water vapor, but its effect was small comparing with other sensors.

  • PDF

Adaptive Bandwidth Algorithm for Optimal Signal Tracking of DGPS Reference Receivers

  • Park, Sang-Hyun;Cho, Deuk-Jae;Seo, Ki-Yeol;Suh, Sang-Hyun
    • Journal of Navigation and Port Research
    • /
    • v.31 no.9
    • /
    • pp.763-769
    • /
    • 2007
  • A narrow loop noise bandwidth method is desirable to reduce the error of raw measurements due to the thermal noise. However, it degrades the performance of GPS initial synchronization such as mean acquisition time. And it restricts the loop noise bandwidth to a fixed value determined by the lower bound of the allowable range of carrier-to-noise power ratio, so that it is difficult to optimally track GPS signal. In order to make up for the weak points of the fixed-type narrow loop noise bandwidth method and simultaneously minimize the error of code and carrier measurements, this paper proposes a stepwise-type adaptive bandwidth algorithm for DGPS reference receivers. In this paper, it is shown that the proposed adaptive bandwidth algorithm can provide more accurate measurements than those of the fixed-type narrow loop noise bandwidth method, in view of analyzing the simulation results between two signal tracking algorithms. This paper also carries out sensitivity analysis of the proposed adaptive bandwidth algorithm due to the estimation uncertainty of carrier-to-noise power ratio. Finally the analysis results are verified by the experiment using GPS simulator.

Effect of Thermal Mechanical Stresses on Electrical Characteristics of Polymer Housed Surge Arresters (열-기계적 스트레스가 폴리머 피뢰기의 전기적 특성에 미치는 영향)

  • Cho, Han-Goo;You, Dae-Hoon
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.20 no.6
    • /
    • pp.555-560
    • /
    • 2007
  • This paper describes the results of a study on the sealing integrity of polymer housed surge arrester based on the thermal mechanical test. The polymer housed surge arrester employs silicone insulating materials for its housing, instead of the conventional porcelain housing. The polymer housed surge arresters exhibited the highest sealing integrity because it is not air volume between the FRP(fiber reinforced plastics) module and the silicone housing. In accordance, the sealing integrity of station class surge arresters is investigated with moisture ingress test. And, the influence of sealing integrity was evaluated through such as measurement of the deflection, reference voltage, leakage current. In electrical characteristics, reference voltage decreased in the range of $16.45{\sim}16.15\;kV$ with after thermal mechanical test. In contrary, despite the continued moisture ingress, the polymer housed surge arresters exhibited almost the same leakage current value and the resistive leakage current has risen slightly. As a results, It was thought that the polymer housed surge arresters shows good stability with sealing integrity.

A Study on the Development of Simple DGPS for the Coastal Survey (연안 해양 관측을 위한 간역 DGPS 개발 연구)

  • 이상룡;문동준;전호경
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.8 no.1
    • /
    • pp.10-17
    • /
    • 1996
  • A real time simple DGPS (SDGPS) for coastal survey is developed and in situ tested. While the accuracy of the system is almost the same as that of existing commercially available DGPS, it is very economical compared to the commercial ones. The RMS error of the positions fired by the system is estimated to be less than 2 m within the range of 30 km from the reference station. Even if the coordinates of the reference station are uncertain, they can be fixed, from the continuous GPS observation of one day, with the maximum error less than 1 m. The system is believed to be helpfully utilized to most of coastal surveys despite of some minor defects.

  • PDF