• Title/Summary/Keyword: reference range

Search Result 1,777, Processing Time 0.03 seconds

Extensometers results correction in concrete dams: A case study in RCC Zhaveh Dam

  • Ziaei, Ahad;Ahangari, Kaveh;Moarefvand, Parviz;Mirzabozorg, Hasan
    • Structural Monitoring and Maintenance
    • /
    • v.4 no.1
    • /
    • pp.17-31
    • /
    • 2017
  • Since extensometers are used to determine the absolute deformation of foundation and abutments and all results are obtained in reference to the base rod, the accuracy of these results has been constantly a subject of debate. In this regard, locating and installing extensometers outside the range of effect zone is also another challenge. The main purpose of this paper is to investigate and modify extensometers results based on the mentioned issues. For this aim, the concrete RCC Zhaveh dam in Iran was selected as the case study. To study the results of extensometers installed in this dam, first, the 3DEC_DP 5.00 software was applied for numerical modeling. Parameters such as discontinuities, dead load and piezometric pressure in the interface of concrete and rock were considered. Next, using the results obtained from 6 extensometers in foundation and abutments and 4 clinometers in dam body, the numerical model was calibrated through back analysis method. The results indicate that the base rod is moved and is not recommended being used as the base point. In other words, because installation of base anchor outside the range of effect zone is not possible due to the operational and economic considerations, the obtained results are not accurate enough. The results indicate a considerable 2-3 mm displacement of the base rod (location of the base anchor) in reference to the real zero point location, which must be added to the base rod results.

Monitoring Nutritional Status of Dairy Cows in Taiwan Using Milk Protein and Milk Urea Nitrogen

  • Hwang, Sen-Yuan;Lee, Mei-Ju;Chiou, Peter Wen-Shyg
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.13 no.12
    • /
    • pp.1667-1673
    • /
    • 2000
  • The climate and marketing system of raw milk in Taiwan create problems in balance feeding of protein and energy in lactating cows in Taiwan. Level of urea nitrogen both in bulk milk and serum reflects ruminal protein degradation and post-ruminal protein provision, whereas milk protein concentration responds to dietary energy intake and bacterial protein production in the rumen. Establishment of a range of reference standards in milk protein and urea nitrogen levels can be applied as a noninvasive economical feeding guide to monitor the balance of protein and energy intake. Standard reference levels of 3.0% milk protein and 11-17 mg/dL milk urea nitrogen (MUN) were established. Level of milk protein below 3.0% is regarded as indicating inadequate dietary energy whereas MUN below or above the range is regarded as a deficiency or surplus in dietary protein. Results from analysis of bulk a milk samples collected from 174 dairy herds over Taiwan showed that only one quarter (25.29%) of the herds received a balanced intake of protein and energy, 33.33% adequate protein with energy inadequate, 22.99% herds in protein surplus with energy inadequate, 10.35% herds in protein surplus with energy adequate, 4.6% protein deficiency with energy adequate, and 3.45% herds with both protein and energy inadequate. Energy inadequate herds accounted for 60% of the total dairy herds in Taiwan with 56% adequate, 38% surplus and 6% inadequate in protein. In comparing milk sampled from bulk milk on different seasons from Lee-Kang area in the southern Taiwan, the concentrations of milk fat and milk protein were significantly higher in the cool season (February) than in the warm season (August) (p<0.05), whereas the urea nitrogen in the milk was significantly lower in the cool season than in the warm season (p<0.05). This indicated that lactating cows had excess protein and/or inadequate energy intake in the warm season in this area. It appears that the major problem feeding in lactating cows is energy intake shortage, especially during the warm season in Taiwan.

A Study on the Dynamic Characteristics of Nitrogen Mixed Gas for Thermostatic Expansion Valve Sensing Blub (온도 감지식 팽창밸브 감온통 질소가스 혼합냉매의 동특성 연구)

  • Kim, Si-Young;Koo, Su-Jin;Ju, Chang-Sik
    • Journal of Power System Engineering
    • /
    • v.18 no.1
    • /
    • pp.69-75
    • /
    • 2014
  • The pressure and temperature characteristics of mixed refrigerant gases in bulb for thermostatic expansion valve were studied using R22 refrigerant and $N_2$ gases. The characteristics of mixed refrigerant gases were investigated according to pressure variation and the variation of composition ratio of R22 refrigerant and $N_2$ gases in the temperature range of -$15^{\circ}C$~$15^{\circ}C$. The Maximum operating pressure(MOP) of mixed refrigerant gases were showed a tendency to decrease with decreasing the mixing ratio of $N_2$ gas. The characteristics in the case of the mixing ratio of 90:1 for R22 refrigerant and $N_2$ gases were the same result as Reference refrigerant. In addition, the characteristics of the mixed refrigerant gases in the mixing ratio of 90:1 for R22 refrigerant and $N_2$ gases were showed almost linear in the measurement range of pressure-temperature, and the physical properties also were showed similar results with Reference refrigerant. It was able to confirm that a MOP on the thermostatic expansion valve for sensing bulb can be maintained by adjusting the mixing ratio of R22 refrigerant and $N_2$ gases.

A Sensing Scheme Utilizing Current-Mode Comparison for On-Chip DC-DC Converter (온칩 DC-DC 변환기를 위한 전류 비교 방식의 센서)

  • Kim, Hyung-Il;Song, Ha-Sun;Kim, Bum-Soo;Kim, Dae-Jeong
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.44 no.4
    • /
    • pp.86-90
    • /
    • 2007
  • An efficient sensing scheme applicable to DC-DC converters is proposed. The output voltage of the DC-DC converter is fed back and converted to a current signal at the input terminal of the sensor to decide if it is in the tolerable range. The comparison is accomplished by a current push-pull action. With the embedded reference current in the sensor realized from the reference voltage. The advantages of the scheme lie in the fairly accurate and efficient implementation in terms of power consumption and chip size overhead compared with conventional voltage-mode schemes as the major parameter in converting voltage to current is determined by (W/L) aspect ratio of the core transistors. In this paper, a DC-DC converter of 5V output from battery range of 2.2V${\sim}$3.6V adopting the proposed sensing scheme is implemented in a 0.35um CMOS process to prove the validity of the scheme.

Development of Reference Epoch Adjustment Model for Correction of GPS Precise Point Positioning Results (GPS 정밀단독측위 성과의 보정을 위한 기준시점 조정모델 개발)

  • Sung, Woo-Jin;Yun, Hong-Sik;Hwang, Jin-Sang;Cho, Jae-Myoung
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.30 no.3
    • /
    • pp.249-258
    • /
    • 2012
  • In this study, the epoch adjustment model was developed to correct GPS precise point positioning result to be suitable for the current geodetic datum of Korea which is tied at past epoch statically. The model is based on the formula describing crustal movements, and the formula is composed of several parameters. To determine the parameters, the data gathered at 14 permanent GPS stations for 10 years, from 2000 to 2011, were processed using GIPSY-OASIS II. It was possible to determine the position of permanent GPS stations with an error range of 16mm and the position of check points with an error range of 12mm by appling the model to GPS precise point positioning result. It is considered that more precise model could be calculated by using GPS data of more permanent GPS stations.

Clinical Utility and Cross-Reactivity of Insulin and C-Peptide Assays by the Lumipulse G1200 System

  • Oh, Jongwon;Kim, Jae Hyeon;Park, Hyung-Doo
    • Annals of Laboratory Medicine
    • /
    • v.38 no.6
    • /
    • pp.530-537
    • /
    • 2018
  • Background: Measurement of insulin and C-peptide concentrations is important for deciding whether insulin treatment is required in diabetic patients. We aimed to investigate the analytical performance of insulin and C-peptide assays using the Lumipulse G1200 system (Fujirebio Inc., Tokyo, Japan). Methods: We examined the precision, linearity, and cross-reactivity of insulin and C-peptide using five insulin analogues and purified proinsulin. A method comparison was conducted between the Lumipulse G1200 and Roche E170 (Roche Diagnostics, Mannheim, Germany) systems in 200 diabetic patients on insulin treatment. Reference intervals for insulin and C-peptide concentrations were determined in 279 healthy individuals. Results: For insulin and C-peptide assays, within-laboratory precision (% CV) was 3.78-4.14 and 2.89-3.35%, respectively. The linearity of the insulin assay in the range of 0-2,778 pmol/L was $R^2=0.9997$, and that of the C-peptide assay in the range of 0-10 nmol/L was $R^2=0.9996$. The correlation coefficient (r) between the Roche E170 and Lumipulse G1200 results was 0.943 (P <0.001) for insulin and 0.996 (P <0.001) for C-peptide. The mean differences in insulin and C-peptide between Lumipulse G1200 and the Roche E170 were 19.4 pmol/L and 0.2 nmol/L, respectively. None of the insulin analogues or proinsulin showed significant cross-reactivity with the Lumipulse G1200. Reference intervals of insulin and C-peptide were 7.64-70.14 pmol/L and 0.17-0.85 nmol/L, respectively. Conclusions: Insulin and C-peptide tests on the Lumipulse G1200 show adequate analytical performance and are expected to be acceptable for use in clinical areas.

Remission of Progesterone-induced Diabetes Mellitus after Ovariohysterectomy in an Intact Female Dog

  • Kim, Ill-Hwa;Choi, Jin-Young;Hwang, Dae-Youn;Kang, Hyun-Gu
    • Journal of Veterinary Clinics
    • /
    • v.36 no.1
    • /
    • pp.74-77
    • /
    • 2019
  • A 10-year-old, 8.28 kg, intact female Cocker Spaniel was presented with continuous polyuria and polydipsia. The dog had proestrus bleeding 5 weeks earlier, and hyperglycemia, glucosuria, ketouria, and high level of serum fructosamine in laboratory findings. Based on hyperglycemia, glucosuria, ketouria, and ketosis, the patient was tentatively diagnosed as diabetes mellitus (DM) with ketouria. After diagnosis, 5 to 7 U/body porcine lente insulin was administered during 11 days from initial presentation as the remission of DM for the dog. But, blood glucose was still high level. Because there was no reaction to porcine lente insulin, it was replaced by 4-10 U/body neutral protamine Hagedorn (NPH) during 3 days. But, NPH also did not regulate blood glucose level. Because insulin therapy failed to regulate blood glucose level, the dog was considering insulin-resistant diabetes. The dog was tentatively diagnosed with progesterone-resistant DM on the basis of the history that had revealed proestrus bleeding 5 weeks earlier. Progesterone level was moderate high (43.7 ng/ml; reference range, 15.0-90.0 ng/ml). Ovariohysterectomy (OHE) was performed to remove the cause of the dog's diabetes. After OHE 11 days, blood glucose was gradually declined by insulin treatment. Consequently, blood glucose was well controlled in reference range without insulin treatment after 2 months. This case is a report on progesterone-induced DM treated with OHE and insulin treatment during the diestrus.

Comparative evaluation of obesity-related parameters in junior sumo wrestlers and children with obesity

  • Ogawa, Miori;Sagayama, Hiroyuki;Tamai, Shinsuke;Momma, Reiko;Hoshi, Daisuke;Uchizawa, Akiko;Ichikawa, Go;Arisaka, Osamu;Watanabe, Koichi
    • Korean Journal of Exercise Nutrition
    • /
    • v.25 no.3
    • /
    • pp.36-43
    • /
    • 2021
  • [Purpose] Exercise is a key factor in preventing obesity and metabolic syndrome. Sumo wrestlers increase their body size from childhood for athletic advantage; however, the risk of metabolic syndrome in junior sumo wrestlers is undetermined. Preventive measures against pediatric obesity should be initiated during childhood to prevent obesity in adulthood, considering its high global incidence. We comparatively evaluated the risk factors for metabolic syndrome in junior sumo wrestlers and children with obesity. [Methods] We enrolled 70 male children (age 9-17 years [sumo group, n = 14] and 9-14 years [other sports and non-exercise groups, n = 28 each]) and evaluated their anthropometric parameters (height, weight, body mass index z-score, obesity rate, waist circumference, waist to height ratio) and hematological parameters (total, low-density, high-density, and non-high-density lipoprotein-cholesterol; triglycerides; plasma glucose, and glycated hemoglobin levels). [Results] The BMI z-score, obesity rate, waist circumference (p < 0.05, along with the non-exercise group), and systolic blood pressure were significantly higher and the high-density cholesterol level was lower in the sumo group than in the other sports group (p < 0.05). The waist to height ratio was significantly higher in the non-exercise group than in the other sports group (p < 0.05). No significant difference was found in other blood lipid, plasma glucose (significantly lower level than the reference range in the sumo group, p < 0.05), and glycated hemoglobin (within the reference range in all groups) levels among the three groups. [Conclusion] Junior sumo wrestlers had a larger body size and higher blood pressure than children with obesity who exercised regularly. This provides direction for future research into targeted preventive interventions against metabolic syndrome for junior sumo wrestlers with large body size.

Treatment of central diabetes insipidus with anemia in a dog

  • Kim, Sol;Lee, Han Joon;Seo, Kyoung Won;Song, Kun-Ho
    • Korean Journal of Veterinary Service
    • /
    • v.45 no.2
    • /
    • pp.139-143
    • /
    • 2022
  • A 10-year-old, spayed female miniature schnauzer was referred to the Veterinary Medical Teaching Hospital of Chungnam National University due to evaluation of sudden polyuria (PU) and, polydipsia (PD) (540 mL/kg/day) with severe anemia and weight loss. Blood examination results were normal except for severe anemia (hematocrit, [HCT]: 11.8%). Urinalysis revealed a urine specific gravity (USG) of 1.003, whereas urine sediment was not specific. Urine osmolality was 90 mOsm (reference range: 800~2500 mOsm), and plasma osmolality was 303 mOsm. No specific lesions were found using diagnostic imaging including radiography, ultrasonography and magnetic resonance imaging (MRI). The serum cortisol level was normal in cosyntropin stimulation test. Plasma arginine vasopressin (AVP) concentration was <0.4 pg/mL (reference range: 3.49~5.45 pg/mL). Blood transfusion was initiated in addition to an oral prescription of desmopressin acetate (DDAVP, 0.1 mg/head) thrice a day for one week. The patient was rechecked for clinical signs, urine osmolality, and USG; the clinical signs of PU/PD were resolved, urine osmolality increased to 1106 mOsm, and, USG increased to 1.021. Considering the improved clinical signs, and increased urine osmolality, and USG after DDAVP treatment, the dog was diagnosed with central diabetes insipidus. USG and urine osmolality increased to >1.030 and 2200 mOsm, respectively. Anemia also gradually improved and HCT increased to >37%. DDAVP was tapered to 0.1 mg/head twice a day and all clinical signs in the patient have completely resolved.

A Study on the Synthetic Aperture Radar System Motion Compensation Technique (SAR(Synthetic Aperture Radar)시스템 요동보상기법 연구)

  • Kang, Eun-Kyun;Ra, Keuk-Hwan
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.3
    • /
    • pp.221-229
    • /
    • 2013
  • In this paper, the image formation by the motion compensation technique for Synthetic Aperture Radar system(SAR) were realized through the computer simulation. The motion compensation technique performed image data with the range compression, the compensation procedure, the azimuth compensation and the noise elimination procedure. The range compression procedure transform the SAR raw data into the frequency domain and correlate with the range reference function and then inversely transform into the time domain. The compensation procedure contain the aircraft fluctuations compensation and the radar image degrading effect elimination procedure which was caused by image formation algorithm itself. The aircraft fluctuations compensation procedure perform the first stage which correct the phase angle and the second stage which calculate the Doppler frequency and determine the coordinate of the received signal. The radar image degrading effect elimination procedure also perform range migration compensation and the image defocussing effect compensation. The azimuth compression procedure transform the compensation data to the frequency domain and correlate with the azimuth reference function. The azimuth correlated data are inversely transformed to the time domain which is called SAR image data. When the above procedure were completed, the image data contains the received signals mixed with noise. The threshold technique was applied to elimination the noise from the mixed image data.