• Title/Summary/Keyword: reference range

Search Result 1,775, Processing Time 0.043 seconds

Fabrication and Characteristics of SAW Gas Sensor (SAW 가스센서의 제작 및 특성)

  • Jun, C.B.;Park, H.D.;Choi, D.H.;Lee, D.D.
    • Journal of Sensor Science and Technology
    • /
    • v.3 no.1
    • /
    • pp.40-45
    • /
    • 1994
  • $112^{\circ}$ rot. x-cut $LiTaO_{3}$ wafer was used as the substrate of SAW gas sensor. Dual delay line SAW device with IDTs which consist of the reference delay line and the sensing delay line was fabricated using photolithigraphy. Each IDTs had 10 finger pairs and finger spacing is 10 microns. One delay line channel is the reference, while the second is the sensing channel with Pb-phthalocyanine film in the propagation path. Pb-phthalocyanine film which is p-type organic semiconductor was evaporated in $10^{-5}$ torr vacuum using shadow mask selectively. Dual delay line oscillator was constructed by using the rf amplifier and AGC. Frequency of the IDTs had the range of $87{\sim}$89 MHz oscillation frequency. Oscillation frequency shifts were investigated as a function of the temperature and the concentration of $NO_{2}$ gas.

  • PDF

The Synchronous Control System Design for Four Electric Cylinders (4축 전동실린더의 동기제어시스템 설계)

  • Yang, Kyong-Uk;Byun, Jung-Hwan
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.11 no.12
    • /
    • pp.1209-1218
    • /
    • 2016
  • In order to safely and speedily transport a load such as a large glass plate using four electric cylinders, the synchronous error outside the permitted range should not be continuously generated between the cylinders. In this study, a methodology of synchronous control which can be applied to synchronization of four or more cylinders is developed. The synchronous control system based on the decoupling structure is composed of a reference model, position and synchronous controllers in the respective cylinders. The reference model is used for calculating the decoupled synchronous error and control input for the each cylinder. The position controller of I-PD type is designed in order that the cylinder may follow the reference signal without overshoot and input saturation. And the synchronous controller of lead compensator is designed to achieve stable and accurate synchronization through loop shaping approach. Finally, the simulation results show that the synchronization between the four cylinders can be quickly and stably while each cylinder rod is transferred to the target point under torque disturbance.

A Warning Threshold Proposal for Operation Improvement of Maritime DGPS Reference Station (해양용 DGPS 운영성 개선을 위한 시스템 경고 임계값 제안)

  • Choi, Yong Kwon;Lee, Ju Hyun;Son, Seok Bo;Lee, Sang Jeong
    • Journal of Advanced Navigation Technology
    • /
    • v.21 no.1
    • /
    • pp.12-20
    • /
    • 2017
  • A maritime DGPS in Korea offers pseudo-range correction information and monitors integrity of correction data by using multiple GNSS receivers. The maritime DGPS reference station and integrity monitor service sets alarm threshold value about integrity monitoring parameters for preventing service interruption status. However there is no way to avoid system interruption according to malfunction of backup systems and outside factors. Therefore, in this paper, warning threshold values were proposed for maritime DGPS operator can be counteract in advance. And Markov analysis method was carried out for selection of these warning threshold values.

Efficiency Enhancement Plan of the Ambiguity Leveling System for Multiple Clusters (미지정수 수준 조정을 고려한 다중클러스터 시스템 효율화 방안)

  • Yu, Sunkyoung;Song, Junesol;Kee, Changdon
    • Journal of Advanced Navigation Technology
    • /
    • v.21 no.6
    • /
    • pp.572-578
    • /
    • 2017
  • As the demand of high accuracy positioning for dynamic users increases, Network RTK is actively researched for dynamic users. Network RTK is a system which provides precise positioning in the range of about 50 to 70km radius using carrier phase measurements from several reference stations. By configuring multiple clusters, which provide Network RTK corrections independently, as a single system, it could provide precise positioning for a wider area. In this paper, we have studied how to efficiently operate multiple clusters in the Korean Peninsula. We analyzed the computational load according to the configuration of a multi-cluster system and proposed a method of selecting the main reference station and system infrastructure configuration for efficient operation. In order to analyze the effects of each proposed method, 71 clusters were constructed using the reference stations of the National Geographic Information Institute and simulations were conducted. As a result of the simulation, system computation amount was reduced by 66 % and system configuration cost was reduced by 90 %.

Reference white setting based on brightness of CPT and resolution (수상관의 밝기 및 해상도를 고려한 기준 백색 설정)

  • 최덕규;김주동;권기룡;안상호;이건일;송규익
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.22 no.2
    • /
    • pp.334-343
    • /
    • 1997
  • Reference white in color television receiver can be achieved by adjusting the RGB gun current ratio and it is necessary to provide additional gain ratio adjustment for the RGB video signal. Generally, the gun current density profile has a gaussian distribution and the gain-bandwidth product of RGB channel amplifieris constant. Therefore brightness and spatial resolution are changed with variations in reference white of receiver. In this paper, the effect of RGB gun current and channel gain ratios on brightness and resolution of CPT is analyzed. Brightness is increased with the color temperature of referenc white because of Helmholtz-kohlrausch effect. The change in ligh output is more abrupt and spatial resolution is improved with unity current ratio. For more bright and improved ressolution we also present the range of color temperature of reference white for P22 phosphors.

  • PDF

The Effectiveness of Blood β-ketone Testing in Patients with Diabetic Ketosis: A Systematic Review & Meta-analysis (당뇨환자에서 자가관리형 베타케톤검사의 유효성: 체계적 문헌 고찰 및 메타분석)

  • Mo, Jin A;Jang, Sunyoung;Bang, Hee Young
    • Korean Journal of Health Education and Promotion
    • /
    • v.31 no.4
    • /
    • pp.1-10
    • /
    • 2014
  • Objectives: The effectiveness of Blood ${\beta}$-ketone testing by using self-monitoring strip on diabetic patients. Methods: Clinical effectiveness of blood ${\beta}$-ketone testing was assessed through correlation with reference test that measured blood ${\beta}$-ketone value through gas chromatography or enzyme method, diagnostic accuracy, time taken for the test and time taken for confirmative diagnosis of diabetic ketosis by selecting literatures on researches that conducted this test on ketosis(suspected) patients or diabetic ketosis(suspected) patients. Each of the stages from literature search to application of selection standards and extraction of data were carried out independently by the Subcommittee along with 2 researchers. Results: 7 reports were selected. ${\beta}$-ketone testing displayed high level of correlation in the range of r=0.92~0.99 with test using enzyme method as the reference standard. Regarding the diagnostic accuracy, sensitivity of 0.82, specificity of 0.74. The time taken for the test was 30seconds for the index test, which is shorter than reference standard test. Conclusion: Blood ${\beta}$-ketone testing was assessed to be a safe and effective test to monitor ketosis and assess the level of risk of ketosis by measuring the blood ${\beta}$-ketone on ketosis patients and diabetic ketosis patients since it has high level of correlation with reference test and short period of testing.

Precise Orbit Estimation of GPS using GIPSY-OASIS (GIPSY-OASIS기반 GPS 정밀 궤도 추정)

  • Ha, Jihyun;Chun, Sebum;Park, Kwan-Dong
    • Journal of Advanced Navigation Technology
    • /
    • v.23 no.6
    • /
    • pp.535-541
    • /
    • 2019
  • In this paper, scripts for estimating the reference orbits of navigation satellites were developed and their performance was analyzed as a preliminary study for the development of the Korean GPS precise orbit determination technology. The JPL Flinn AC's data processing strategy was applied and Linux-based scripts were developed using GIPSY-OASIS. For the analysis of the accuracy of the estimated reference orbit, the precise orbit provided by the international GNSS data center was used as the truth. As a result, estimated satellite coordinates showed almost exactly same patterns and trends with the reference precise orbits, and their differences are in the range of ±2 cm. The average error between the two orbits was less than 1 cm in the 3D direction, while the standard deviation was also at 1 cm. From these, we found that the developed scripts have excellent performance in precise orbit determination.

Electrospray Tandem Mass Spectrometry for the Quantification and Bioavailability Test of Gliquidone in Human Plasma (Electrospray Tandem Mass를 이용한 혈중 글리퀴돈의 정량법 개발 및 생체이용률시험)

  • Moon Chul-Jin;Lee Eun-Hee;Yang Song-Hyun;Moon Hae-Ran
    • YAKHAK HOEJI
    • /
    • v.49 no.3
    • /
    • pp.212-216
    • /
    • 2005
  • A rapid, sensitive and selective electrospray tandem mass spectrometric (ESI-LC/MS/MS) method for the quantitation of gliquidone in human plasma was developed. A bioavailability study of gliquidone tablet (30 mg gliquidone, Boehringer Ingelheim Korea Co.) was performed using the validated ESI-LC/MS/MS method. The dose of 30 mg of gliquidone (1 tablet) was orally administered to 9 healthy Korean subjects. After administration, blood was taken at 0.5, 1, 1.5, 2, 2.5, 3, 3.5, 4, 5, 7, 9, 12, 24, and 33 hour. The validation data were as follows; the standard curve was linear ($r^2$=0.999) over the concentration range of $10\~1000 ng/ml$. The coefficient of variation for intra- and inter-day assay were $8.30\~18.86$, and $2.19\~12.92\%$, respectively. The lower limit of quantification for gliquidone was 10 ng/ml. The pharmacokinetic parameters obtained were as follows; $AUC_t$ was 3861.17$\pm$1328.61 ng-hr/ml, $C_{max}$ was 831.02$\pm$227.99 ng/ml, $T_{max}$ was $2.94{\pm}0.77 hr,\;K_e$, was 0.19$\pm$0.06 1/hr, and $t_{l/2}$ was 4.47$\pm$3.52 hr. Based on the validated analytical method and pharmacokinetic parameters, a standard guideline of the bioavailability test of gliquidone dosage forms was prepared successfully and could be used for the bioequivalence test of gliquidone preparation.

Tandem Mass Spectrometry for the Quantification and Bioavailability Test of Nicorandil in Human Plasma (Tandem Mass를 이용한 혈중 니코란딜의 정량법 개발 및 생체이용률시험)

  • Moon Chul-Jin;Lee Eun-Hee;Yang Song-Hyun;Moon Hae-Ran
    • YAKHAK HOEJI
    • /
    • v.49 no.3
    • /
    • pp.225-229
    • /
    • 2005
  • A rapid, sensitive and selective tandem mass spectrometric method (LC-MS/MS) for the quantitation of nicorandil in human plasma was developed. A bioavailability study of Sigmat tablet (5 mg nicorandil, Choongwae Co.) was per-formed using the validated LC-MS/MS method. The dose of 5 fig of nicorandil (1 tablet) was orally administered to 9 healthy Korean subjects. After administration, blood was taken at 0.25, 0.5, 1, 2, 3, 4, 5, 6, 9, 12, and 24 hour. The validation data were as follows; the standard curve was linear ($r^2$=0.999) over the concentration range of $0.5\~200.0 ng/ml$. The coefficient of variation for intra- and inter-day assay were $3.55\~7.44$, and $2.17\~9.102\%$, respectively. The lower limit of quantification for nicorandil was 0.5 ng/ml. The pharmacokinetic parameters obtained were as follows; $AUC_t$ was 145.9$\pm$83.0 ng-hr/ml, Cmax was 83.8$\pm$32.2 ng/ml, $C_{max}$ was 0.42$\pm$0.13 hr, $K_e$ was 0.56$\pm$0.23 l/hr, and $t_{l/2}$ was 1.42$\pm$0.52 hr. Based on the validated analytical method and pharmacokinetic parameters, a standard guideline of the bioavailability test of nicorandil dos-age forms was prepared successfully and could be used for the bioequivalence test of nicorandil preparation.

A Low-Noise Low Dropout Regulator in $0.18{\mu}m$ CMOS ($0.18{\mu}m$ CMOS 저 잡음 LDO 레귤레이터)

  • Han, Sang-Won;Kim, Jong-Sik;Won, Kwang-Ho;Shin, Hyun-Chol
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.46 no.6
    • /
    • pp.52-57
    • /
    • 2009
  • This paper presents a low-noise low-dropout linear regulator that is suitable for on-chip integration with RF transceiver ICs. In the bandgap reference, a stacked diode structure is adopted for saving silicon area as well as maintaining low output noise characteristic. Theoretical analysis for supporting the approach is also described. The linear regulator is fabricated in $0.18{\mu}m$ CMOS process. It operates with an input voltage range of 2.2 V - 5 V and provide the output voltage of 1.8 V and the output current up to 90 mA. The measured line and load regulation is 0.04%/V and 0.46%, respectively. The output noise voltage is measured to be 479 nV/$^\surd{Hz}$ and 186 nV/$^\surd{Hz}$ from 100 Hz and 1 kHz offset, respectively.