• Title/Summary/Keyword: reference range

Search Result 1,777, Processing Time 0.032 seconds

Radiotherapic Valuation of Paraffin Wax for Patients with Oral Cancer (구강암 환자 치료시 치과용 기초상 왁스(Paraffin Wax)의 유용성 평가)

  • Na, Kyoung-Su;Seo, Seuk-Jin;Lee, Je-Hee;Yoo, Sook-Heun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.23 no.1
    • /
    • pp.41-49
    • /
    • 2011
  • Purpose: This study is designed to investigate radiotherapic valuation of Paraffin Wax, which is newly formed for this study and generally utilized in dentistry, and Mouth Piece and Putty impression, which are commonly used in radiotherapy, for oral cavity as a compensator. Materials and Methods: Each compensator was formed by $10{\times}10{\times}1cm$ and measured radiation dose attenuation ratio with reference of water phantom which is made of tissue-equivalent materials. Two patients with oral cancer underwent DRR (Digitally Reconstructed Radiogrph) of Offline Review Program of Aria System and Portal vision for 5 times for each material to evaluate reproducibility by each filling materials. Moreover, MU (monitor unit) changes by dose absorption were considered in the case of inevitable implication of an filling materials in the range for radiotherapy. Results: Radiation dose attenuation ratios were shown -0.7~+3.7% for Mouth Piece, +0.21~+0.39% for Paraffin Wax and -2.71~-1.76% for Putty impression. Error ranges of reproducibility of positions were measured ${\pm}3mm$ for Mouth Piece, ${\pm}2mm$ for Paraffin Wax and ${\pm}2mm$ mm for Putty impression. Difference of prescription MU from dose absorption with an filling material increased +7.8% (250 MU) in Putty impression and -0.9% (230 MU) in Paraffin Wax as converted into a percentage from the standard phantom, Water 232 MU. Conclusion: Dose reduction of boundary between cavity and tissue was observed for Mouth Piece. Mouth Piece also had low reproducibility of positions as it had no reflection of anatomy of oral cavity even though it was a proper material to separate Maxilla and Mandible during therapy. On the other hand, Putty impression was a suitable material to correctly re-position oral cavity as before. However, it risked normal tissues getting unnecessary over irradiation and it caused radiation dose decrease by -2.5% for 1cm volume in comparison of it of water phantom. Dose reduction in Paraffin Wax, Fat Tissue-Equivalent Material, was smaller than other impressions and position reproducibility of it was remarkable as it was possible to make an anatomy reflected impression. It was also well fitted to oral cavity to transfer radiation dose planned in radiotherapy. Thus, Paraffin Wax will be an ideal material in radiotherapy for patients with oral cancer.

  • PDF

Nutritional Status of Continuous Ambulatory Peritoneal Dialysis Patients (지속성복막투석 환자의 영양상태에 관한 연구)

  • Park, Jin-Kyung;Son, Sook-Mee
    • Journal of Nutrition and Health
    • /
    • v.39 no.7
    • /
    • pp.624-640
    • /
    • 2006
  • Dialysis patients are at risk of malnutrition not only because of losses of nutrients during peritoneal dialysis but also because of anorexia that results in inadequate nutrient intakes. The aim of this study was to estimate the nutritional status of 154 patients receiving continuous ambulatory peritoneal dialysis (CAPD), especially focused on protein-energy malnutrition and vitamin and mineral status. The mean age of the subjects was $5.12\;{\pm}\;12.4\;y$ with educational years of $12.3\;{\pm}\;0.4\;y$ for male and $9.6\;{\pm}\;0.4\;y$ for female. The mean duration of dialysis was $22.7\;{\pm}\;21.7\;mo$. The causes of renal failure included diabetes (32.7), chronic glomerulonephritis (15.0%), and hypertension (8.5%). The main complications associated with chronic renal failure were hypertension (86.1%), diabetes (35.4%) and liver disease (9.0%). The mean daily energy intake was $1216.8\;{\pm}\;457.3\;kcal$ and increased to $1509.2\;{\pm}\;457.2\;kcal$ when added with the energy from dextrose in dialysate. The latter was still much lower than estimated energy requirement but energy intake per kg of body weight (28.1 kcal/1 g) was within the range of that recommended for CAPD patients' diet therapy (25 - 30 kcal/kg). The average daily intake of protein was $49.2\;{\pm}\;25.1\;g$ with 37.6% of the patients showing their intakes less than Estimated Average Requirement. The average protein intake per kg of weight was 0.9 g/kg, which is less than that recommended for CAPD patients (1.2-1.5g/kg) with mean serum albumin level $3.2\;{\pm}\;0.5\;g/dl$. The proportion of the patients with dietary calcium intake less than EAR was 90.9%, but when added with supplementary calcium (phosphorus binder), most patients showed their total calcium intake between EAR and UL. Fifty percent of the patients were observed with dietary iron intake less than EAR, however most patients revealed their total iron intake with supplementation above UL. The addition of folic acid with supplementation increased mean total folic intake to $1126.0\;{\pm}\;152.4\;{\mu}g$ and ninety eight percent of the subjects showed their total folic acid intake above UL. The prevalence of anemia was 83.1 % assessed with hemoglobin level, even with high intakes of iron with supplementation. Thirty four percent of the patients showed their fasting blood glucose was not under control $(\geq\;126\;mg/dl)$ even with medication or insulin probably due to dextrose from dialysate. The mean blood lipid levels were within the reference levels of hyperlipidemia, but with 72.1 % of the patients showing lower HDL-C. In conclusion, Fairly large proportion of the patients were observed with protein malnutrition with low intake of protein and serum albumin level. Few patients showed their vitamins and minerals intake less than EAR with supplementation. For iron and folic acid, their intakes were increased to above UL for large proportion of he patients. However, more than eighty percent of the patients were still anemic associated with decreased renal function. The serum blood glucose and lipid level were not under control for some patients with medication. It seems that supplementation and medications that patients are taking should be considered for dietary consulting of CAPD patients.

A 1.1V 12b 100MS/s 0.43㎟ ADC based on a low-voltage gain-boosting amplifier in a 45nm CMOS technology (45nm CMOS 공정기술에 최적화된 저전압용 이득-부스팅 증폭기 기반의 1.1V 12b 100MS/s 0.43㎟ ADC)

  • An, Tai-Ji;Park, Jun-Sang;Roh, Ji-Hyun;Lee, Mun-Kyo;Nah, Sun-Phil;Lee, Seung-Hoon
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.7
    • /
    • pp.122-130
    • /
    • 2013
  • This work proposes a 12b 100MS/s 45nm CMOS four-step pipeline ADC for high-speed digital communication systems requiring high resolution, low power, and small size. The input SHA employs a gate-bootstrapping circuit to sample wide-band input signals with an accuracy of 12 bits or more. The input SHA and MDACs adopt two-stage op-amps with a gain-boosting technique to achieve the required DC gain and high signal swing range. In addition, cascode and Miller frequency-compensation techniques are selectively used for wide bandwidth and stable signal settling. The cascode current mirror minimizes current mismatch by channel length modulation and supply variation. The finger width of current mirrors and amplifiers is laid out in the same size to reduce device mismatch. The proposed supply- and temperature-insensitive current and voltage references are implemented on chip with optional off-chip reference voltages for various system applications. The prototype ADC in a 45nm CMOS demonstrates the measured DNL and INL within 0.88LSB and 1.46LSB, respectively. The ADC shows a maximum SNDR of 61.0dB and a maximum SFDR of 74.9dB at 100MS/s, respectively. The ADC with an active die area of $0.43mm^2$ consumes 29.8mW at 100MS/s and a 1.1V supply.

Comparison of Radiation Dose in the Measurement of MDCT Radiation Dose according to Correction of Temperatures and Pressure, and Calibration of Ionization Chamber (MDCT 선량측정에서 온도와 압력에 따른 보정과 Ionization Chamber의 Calibration 전후 선량의 비교평가)

  • Lee, Chang-Lae;Kim, Hee-Joung;Jeon, Seong-Su;Cho, Hyo-Min;Nam, So-Ra;Jung, Ji-Young;Lee, Young-Jin;Lee, Seung-Jae;Dong, Kyung-Rae
    • Progress in Medical Physics
    • /
    • v.19 no.1
    • /
    • pp.49-55
    • /
    • 2008
  • This study aims to conduct the comparative analysis of the radiation dose according to before and after the calibration of the ionization chamber used for measuring radiation dose in the MDCT, as well as of $CTDI_w$ according to temperature and pressure correction factors in the CT room. A comparative analysis was conducted based on the measured MDCT (GE light speed plus 4 slice, USA) data using head and body CT dosimetric phantom, and Model 2026C electrometer (RADICAL 2026C, USA) calibrated on March 21, 2007. As a result, the $CTDI_w$ value which reflected calibration factors, as well as correction factors of temperature and pressure, was found to be the range of $0.479{\sim}3.162mGy$ in effective radiation dose than the uncorrected values. Also, under the routine abdomen routine CT image acquisition conditions used in reference hospitals, patient effective dose was measured to indicate the difference of the maximum of 0.7 mSv between before and after the application of such factors. These results imply that the calibration of the ion chamber, and the correction of temperature and pressure of the CT room are crucial in measuring and calculating patient effective dose. Thus, to measure patient radiation dose accurately, the detailed information should be made available regarding not only the temperature and pressure of the CT room, but also the humidity and recombination factor, characteristics of X-ray beam quality, exposure conditions, scan region, and so forth.

  • PDF

Korea's Optimal Basket Exchange Rate : Thoughts on the Proper Operation of the Market Average Rate Regime (우리나라의 적정(適正)바스켓환율(換率) : 시장평균환율제도(市場平均換率制度)의 운용기준(運用基準) 모색(模索))

  • Oum, Bong-sung
    • KDI Journal of Economic Policy
    • /
    • v.12 no.1
    • /
    • pp.111-125
    • /
    • 1990
  • For the last several years, considerable criticism has been leveled against Korea's exchange rate management. While Korea was designated a currency manipulator by the U.S., domestically it is often complained that the won/dollar rate did not adequately reflect changes in Korea's export competitiveness and fluctuations in the exchange rates of major currencies. In view of this situation, Korea changed its exchange regime at the beginning of March this year from the dual currency basket system to a more flexible one, called a "market average rate regime". Under this new regime, the won rate is determined in the exchange market based upon the supply of and demand for foreign exchange and is allowed to freely fluctuate each day within a + 0.4 % range. This paper, first, seeks to evaluate Korea's exchange rate management under the dual basket regime of the 1980s, and then to construct an optimal currency basket for the won which could provide a proper indicator for exchange market intervention under the new market average rate regime. The analysis of fluctuations in the real effective exchange rate (REER) of the won indicates that the won rates in the 1980s failed not only to offset changes in relative prices between home and trading partner countries, but also to properly respond to variations in major exchange rates as further evidenced by sizable fluctuations in the nominal effective rates of the won. In other words, the currency basket regime which was adopted in 1980 for the stabilization of the REER of the won has not been operated properly, mainly because authorities often resorted to policy considerations in determining the won's rate. In the second part of the paper, an optimal currency basket for Korea is constructed, designed to minimize the fluctuations in the REER of the won without including policy considerations as a factor. It is recognized, however, that both domestic and foreign price data are not available immediately for the calculation of the REER. For this problem, the approach suggested by Lipschitz (1980) is followed, in which optimal weights for currencies in the basket are determined based upon the past correlation between price and exchange rates. When the optimal basket is applied to Korea since the mid-80s, it is found that the REER of the won could have been much more stable than it actually was. We also argue for the use of variable weights rather than fixed ones, which would be determined by the changing relationship between exchange rates and relative prices. The optimal basket, and the optimal basket exchange rate based on that basket, could provide an important medium- or long-term reference for proper exchange market intervention under the market average rate regime, together with other factors, such as developments in the current account balance and changes in productivity.

  • PDF

Evaluation of Pheromone Lure of Grapholita molesta (Lpidoptera: Torticidae) and Forecasting Its Phenological Events in Suwon (복숭아순나방 성페로몬 미끼 평가 및 수원지역에서 주요 발생시기 예찰)

  • Kim Dong Soon;Boo Kyung Saeng;Jeon Heung Yong
    • Korean journal of applied entomology
    • /
    • v.43 no.4 s.137
    • /
    • pp.281-289
    • /
    • 2004
  • The sex pheromone blend (28-12AC : E8-12AC : Z8-12OH = 95 : 5 : 1) of oriental fruit moth, Grapholita molesta (Busck), was evaluated with reference to its male attractivity at different dosage and lure longevity of 1.0 mg in a field condition. Also, degree-days (DD) were calculated up to major phenological events of G. molesta using seasonal adult flights monitored by pheromone traps and egg population densities in early season in Suwon peach orchards. In the range of 0.1-4.0 mg dosage examined, G. molesta males caught in pheromone trap decreased with increasing total pheromone doses. The highest number of G. molesta males were attracted in traps baited with 0.1 mg-lure, and there were no significantly differences among 0.5 to 4.0 mg-lure. In longevity test with a 1.0 mg-lure, there was no difference in mean numbers of G. molesta males caught between traps with fresh-baited lures every 20d and field-lasted lures up to ${\approx}50d$ after trap installation, but thereafter more G. molesta males were attracted in the field-lasted lures than in the fresh-baited lures. Accumulated degree-days (DD) from January 1 to the first adult emergence (biofix) were 39DD at a lower threshold temperature $8.1^{\circ}C$. Degree-days from the biofix up to the 1st adult peak through 4th peak were 98DD, 620DD, 1233DD, and 1916DD, respectively. Required degree-days from the 1st adult peak to the 1st egg peak were 130DD, while the 2nd egg peak timing was simultaneous with the 2nd adult peak. Further, management strategies of G. molesta were discussed in peach orchards.

Initial Charge/Discharge of $LiCoO_2$ Composite Cathode with Various Content of Conductive Material for the Lithium ion Battery (리튬이온전지용 $LiCoO_2$정극의 도전재료에 따른 초기 충방전 특성)

  • Doh Chil-Hoon;Moon Seong-In;Yun Mun-Soo;Yun Suong-Kyu;Yum Duk-Hyung;Park Chun-Jun
    • Journal of the Korean Electrochemical Society
    • /
    • v.2 no.3
    • /
    • pp.123-129
    • /
    • 1999
  • Initial electrochemical characteristics of $LiCoO_2$ electrode for lithium ion battery with various content of super s black as conductive material were evaluated through the charge/discharge with the potential range of 4.3V to 2.0V versus $Li^+/Li^+$. The rate of C/4 and C/2 by the 3 electrode test cell composed with an electrolytic solution of 1 mol/l $LiPF_6/EC+DEC(1:3\;by\; weight)$. Lithium was used as reference electrode. High impedance charge behavior was observed at early stage of charge. In the case of $3\%w/w$ of super s black as conductive material, the specific resistance of the high impedance releasing was $3.82\;{\Omega}\;{\cdot}\;g-LiCoCo_2$ at the current density of $0.5 mA/cm^2$, which corresponds 7 times of the specific resistance of electrode $(0.728 g-LiCoO_2)$. At second charge, the specific resistance of the high impedance releasing was 63 mn · g-Lico02, which corresponds 12eio of the specific resistance of electrode and only $1.7\%$ of that of the first charge. The first charge and discharge specific capacities at C/4 rate were 160-161 and $153\~155mAh/g-LiCoO_2$, respectively, to lead $95.4\~96.4\%$ of coulombic efficiencies and ca. $6 mAh/g-LiCoO_2$ of initial irreversible specific capacity. Specific resistance at the end of charge and rest showed low value at content of super s black between 2 and $7\%w/w$, which agreed with characteristics of irreversible specific capacity. Capacity densities were reduced by the increasing the content of conductive material. They were 447 and 431mAh/ml when 2 and $2.9\%w/w$ of super s black were used, respectively, at the rate of C/4.

Improvement of Heat Pump Heating Performance by Selective Heat Storage Using Air Heat of Inside and Outside Greenhouse (온실 내외부 공기열의 선택적 축열에 의한 히트펌프 난방성능 개선)

  • Kwon, Jin Kyung;Kim, Seung Hee;Jeon, Jong Gil;Kang, Youn Koo;Jang, Kab Yeol
    • Journal of Bio-Environment Control
    • /
    • v.26 no.4
    • /
    • pp.353-360
    • /
    • 2017
  • In this study, the design and performance test of the air to water heat pump capable of producing hot water for greenhouse heating by using the surplus solar heat inside the greenhouse and the air heat outside greenhouse as the selective heat source were conducted. The heat storage operations using the surplus solar heat and the outside air heat were designed to be switched according to the setting temperature of the greenhouse in consideration of the optimum temperature range of the crop. In the developed system, it was possible to automatically control the switching of heat storage operation, heating and ventilation by setting 12 reference temperatures on the control panel. In the selective heat storage operation with the surplus solar heat and outside air heat, the temperature of thermal storage tank was controlled variably from $35^{\circ}C$ to $52^{\circ}C$ according to the heat storage rate and heating load. The heat storage operation times using the surplus solar heat and outside air heat were 23.1% and 30.7% of the experimental time respectively and the heat pump pause time was 46.2%. COP(coefficient of performance) of the heat pump of the heat storage operation using the surplus solar heat and outside air heat were 3.83 and 2.77 respectively and was 3.24 for whole selective heat storage operation. For the comparative experiment, the heat storage operation using the outside air heat only was performed under the condition that the temperature of the thermal storage tank was controlled constantly from 50 to $52^{\circ}C$, and COP was analyzed to be 2.33. As a result, it was confirmed that the COP of the heat storage operation using the surplus solar heat and outside air heat as selective heat source and the variable temperature control of the thermal storage tank was 39% higher than that of the general heat storage operation using the outside air heat only and the constant temperature control of the thermal storage tank.

Improved Acroparesthesia During Enzyme Replacement Therapy in a Patient Lately Diagnosed with Fabry Disease (진단이 지연된 Fabry 병 환자에서 효소대체요법을 통한 사지 말단 동통의 호전을 보인 1례)

  • Yang, Aram;Kim, Jinsup;Cho, Sung Yoon;Jin, Dong-Kyu
    • Journal of The Korean Society of Inherited Metabolic disease
    • /
    • v.17 no.3
    • /
    • pp.92-95
    • /
    • 2017
  • Fabry disease (FD) is an X-linked lysosomal storage disorder caused by an ${\alpha}$-galactosidase A (GLA, MIM 300644) enzyme deficiency due to pathogenic variants in the ${\alpha}$-galactosidase A gene (GLA). The disease leads to accumulation of globotriaosylceramide (Gb3) and related glycophospholipids affecting nearly all major organ systems, with the primary sites damaged by Gb3 including renal glomeruli, myocardium, neurons of the dorsal ganglion and autonomic nervous system, and vascular endothelial and smooth muscle. Progressive deposition in these organ systems present with various clinical manifestations including acroparesthesia, renal failure and heart failure. Here, we report a Chinese male diagnosed with Fabry disease in his late $4^{th}$ decades showing improvement of acroparesthesia during enzyme replacement therapy (ERT). A 48-year-old Chinese man who presented with chronic recurrent severe burning pain in his fingers and toes since the age of 10, with worse involvement of the former visited to our clinic for further evaluation. His medical history included a transient ischemic attack aged 40 and diagnosed with stage 4-5 chronic kidney disease aged 47. In the family history, the patient's brother was found to be have Fabry disease 1 month before his visit. Except for his brother, all other members of the family are healthy. Based on his medical history and family history, he was strongly suspicious for Fabry disease. He was found to have a galactose-alpha-1,3-galactose level 4.96 (Reference range, 42.5-67.9) suggestive of Fabry disease. The followed sequencing of GLA coding region in our patient revealed hemizyosity for the mutation c.988C>T (Q330X) in Exon 7. Since ERT start, he showed significant improvement in his symptoms of burning sensation of fingers and toes. On the contrary, due to deteriorating kidney function even with ERT, he is considered for kidney transplantation. Despite of diagnostic delay until late 4th decades, ERT showed a potential improvement of acroparesthesia in our patient. However, late start of ERT can lead to poor outcome in multiorgan function. Therefore, early diagnosis with high index of suspicion followed by continuous ERT with regular monitoring have an impact on quality of life in Fabry disease.

  • PDF

Long-term Outcome of Glycogen Storage Disease Type 1; Analysis of Risk Factors for Hepatic Adenoma (당원병 제1형의 장기 추적 관찰; 간선종 발생의 위험 요인에 대한 연구)

  • Yang, Hye-Ran;Seo, Jeong-Kee
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.6 no.2
    • /
    • pp.129-139
    • /
    • 2003
  • Purpose: The aim of the study was to evaluate the long-term outcome of glycogen storage disease (GSD) type 1 with particular reference to hepatic adenoma and hepatocellular carcinoma, and to analyze risk factors affecting the development of hepatic adenoma in GSD type 1. Methods: Forty-three GSD type 1 patients (31 males and 12 females, mean age $13.9{\pm}6.4$ years) were analyzed retrospectively. Hepatic adenoma was detected on abdominal USG and diagnosed on histologic examination. Clinical profiles were compared between patients with hepatic adenoma (n=16) and age-matched controls without hepatic adenoma (n=16). Results: 1) Of 43 GSD type 1 patients, 16 (37.2%) had hepatic adeoma. Hepatic adenoma was detected at the age of mean $14.2{\pm}4.1$ years (range: 7.9~25.7 years). Fourteen (87.5%) adenomas were multiple at detection. 2) Comparison of the clinical profiles between adenoma group and non-adenoma group revealed that age at first introduction of uncooked cornstarch treatment was significantly late in adenoma group compared with non-adenoma group ($9.1{\pm}5.2$ years vs. $3.0{\pm}1.8$ years, p=0.003). Portocaval shunt surgery was performed in 11 (68.8%) patients in adenoma group and 3 (18.8%) in non-adenoma group (p=0.004). Hepatic adenoma developed mean $5.8{\pm}4.2$ years after shunt operation. 3) One patient was diagnosed as hepatocellular carcinoma at the age of 25.7 years. Conclusion: Hepatic adenoma is an important late complication of GSD type 1 with the risk of malignant transformation. Early introduction of cornstarch therapy with strict metabolic control is needed to prevent the development of hepatic adenoma in GSD type 1.

  • PDF