• Title/Summary/Keyword: reference pulse

Search Result 324, Processing Time 0.026 seconds

Estimation of Respiration Using Photoplethysmograph During Sleep (광용적맥파 신호를 이용한 수면 중 호흡 추정)

  • Park, Jong-Uk;Lee, Jeon;Lee, Hyo-Ki;Kim, Hojoong;Lee, Kyoung-Joung
    • Journal of Biomedical Engineering Research
    • /
    • v.34 no.3
    • /
    • pp.105-110
    • /
    • 2013
  • Respiratory signal is one of the important physiological information indicating the status and function of the body. Recent studies have provided the possibility of being able to estimate the respiratory signal by using a change of PWV(pulse width variability), PRV(pulse rate variability) and PAV(pulse amplitude variability) in the PPG (photoplethysmography) signal during daily life. But, it is not clear whether the respiratory monitoring is possible even during sleep. Therefore, in this paper, we estimated the respiration from PWV, PRV and PAV of PPG signals during sleep. In addition, respiration rates of the estimated respiration signal were calculated through a time-frequency analysis, and errors between respiration rates calculated from each parameter and from reference signal were evaluated in terms of 1 sec, 10 sec and 1 min. As a result, it showed the errors in PWV(1s: $36.38{\pm}37.69$ mHz, 10s: $36.53{\pm}38.16$ mHz, 60s: $30.35{\pm}38.72$ mHz), in PRV(1s: $1.45{\pm}1.38$ mHz, 10s: $1.44{\pm}1.37$ mHz, 60s: $0.45{\pm}0.56$ mHz), and in PAV(1s: $1.05{\pm}0.81$ mHz, 10s: $1.05{\pm}0.79$ mHz, 60s: $0.56{\pm}0.93$ mHz). The errors in PRV and PAV are lower than that of PWV. Finally, we concluded that PRV and PAV are more effective than PWV in monitoring the respiration in daily life as well as during sleep.

The Classification and Criterion for Low Back Pain Examined from Reference Books of Yi Xue Ru Men(醫學入門) (『의학입문(醫學入門)』의 인용서적으로 살펴본 요통(腰痛)의 분류와 기준)

  • Jo, Hak-Jin
    • Journal of Korean Medical classics
    • /
    • v.28 no.1
    • /
    • pp.35-53
    • /
    • 2015
  • Objectives : In order to find how reference books of Yi Xue Ru Men reflect the classification and criterion for low back pain(LBP). Methods : From reference books of Yi Xue Ru Men, select the texts on classification and criterion for LBP. Results : According to the causes of LBP, Chao Yuan Fang(巢元方) in Sui Dynasty assorted to 5 types of LBP at the very first. Chen Wu Ze(陳無擇) in Song Dynasty made 7 divisions by external, internal, and non-external, non-internal causes. According to the pulse of LBP, Yan Yong He(嚴用和) first categorized 4 groups, Zhu Zhen Heng(朱震亨) added another 4 groups. Aside from this standard, Zhu(朱震亨) adopted the cause standard. Depending on Yunqi(運氣), Lou Ying(樓英) classified 5 types. But his classification had been not adopted by any TCM books. According to symptom of 6 varieties(六變), Zhang Jie Bin(張介賓) assorted external(表), internal(裏), deficiency(虛), sufficiency(實), cold(寒) and heat(熱), add 2 groups besides them. But his categorization did not reflect Yi Xue Ru Men. Li Chan(李梴), the author of this book chose causes and pulse classification standards that Zhu Zhen Heng had adopt. Conclusions : In the side of classification and criterion for LBP, Li Chan first divided 2 group, external and internal injury. After it he subdivided both groups to 10 subgroup. His classification is similar to Chen(陳無擇)'s, but actually followed the classification for external and internal injury that was invented by Li Dong Yuan(李東垣).

Development of Feature Points Detection Algorithm for Measuring of Pulse Wave Velocity (맥파 전달 속도(PWV) 측정을 위한 특징점 검출 알고리즘 개발)

  • Choi, Jung-Hyeon;Cho, Wook-Hyun;Park, Jun-Ho;Kim, Nam-Hoon;Seong, Hyang-Sook;Cho, Jong-Man
    • Journal of Sensor Science and Technology
    • /
    • v.20 no.5
    • /
    • pp.343-350
    • /
    • 2011
  • The compliance and stiffness of artery are closely related with disease of arteries. Pulse wave velocity(PWV) in the blood vessel is a basic and common parameter in the hemodynamics of blood pressure and blood flow wave traveling in arteries because the PWV is affected directly by the conditions of blood vessels. However, there is no standardized method to measure the PWV and it is difficult to measure. The conventional PWV measurement has being done by manual calculation of the pulse wave transmission time between coronary arterial proximal and distal points on a strip chart on which the pulse wave and ECG signal are recorded. In this study, a pressure sensor consisting of strain gauges is used to measure the blood pressure of arteries in invasive method and regular ECG electrodes are used to record the ECG signal. The R-peak point of ECG is extracted by using a reference level and time windowing technique and the ascending starting point of blood pressure is determined by using differentiation of the blood pressure signal and time windowing technique. The algorithm proposed in this study, which can measure PWV automatically, shows robust and good results in the extraction of feature points and calculation of PWV.

A study on the improvement of average seek time which use ref_T. E signal and sample pulse signal in optical disk drive (광디스크 드라이브에서 ref_T. E신호 와 샘플펄스 신호를 이용한 평균 탐색시간 개선에 관한 연구)

  • Lee, Si-Hyun;Kim, Kye-Kook;Kim, Hyung-Lea
    • The Journal of the Acoustical Society of Korea
    • /
    • v.14 no.4
    • /
    • pp.5-11
    • /
    • 1995
  • In this paper, we design the new high-speed seek algorithm which can access the data of disk (in 3.5-inch optical disk drive). When seek the target track on optical disk in high-speed using the ref-T. E(Reference Tracking Error) and sample pulse signal, it's always possible high-speed seek without re-check and compensation for error by the ref_T. E and sample pulse signal. The performance test result is represented as follow ; it is satify the average seek time of 28mses.

  • PDF

A New DPWM Method to Suppress the Low Frequency Oscillation of the Neutral-Point Voltage for NPC Three-Level Inverters

  • Lyu, Jianguo;Hu, Wenbin;Wu, Fuyun;Yao, Kai;Wu, Junji
    • Journal of Power Electronics
    • /
    • v.15 no.5
    • /
    • pp.1207-1216
    • /
    • 2015
  • In order to suppress the low frequency oscillation of the neutral-point voltage for three-level inverters, this paper proposes a new discontinuous pulse width modulation (DPWM) control method. The conventional sinusoidal pulse width modulation (SPWM) control has no effect on balancing the neutral-point voltage. Based on the basic control principle of DPWM, the relationship between the reference space voltage vector and the neutral-point current is analyzed. The proposed method suppresses the low frequency oscillation of the neutral-point voltage by keeping the switches of a certain phase no switching in one carrier cycle. So the operating time of the positive and negative small vectors is equal. Comparing with the conventional SPWM control method, the proposed DPWM control method suppresses the low frequency oscillation of the neutral-point voltage, decreases the output waveform harmonics, and increases both the output waveform quality and the system efficiency. An experiment has been realized by a neutral-point clamped (NPC) three-level inverter prototype based on STM32F407-CPLD. The experimental results verify the correctness of the theoretical analysis and the effectiveness of the proposed DPWM method.

Determination of Lead(II) at Nation-Coated Glassy Carbon Electrodes Modified by Tetren-Glycerol (Nafion-Tetren-Glycerol이 수식된 유리탄소전극에서 납(II) 이온의 정량)

  • 반옥기;박은희;정근호
    • Journal of Environmental Health Sciences
    • /
    • v.29 no.2
    • /
    • pp.62-68
    • /
    • 2003
  • Differential pulse voltammetry (DPV) using nafion-coated glassy carbon electrodes modified with Tetren(tetraethylene pentamine)-glycerol showed sensitivity for determining lead (II) at low concentration. The Lead (II) was accumulated on the electrode surface by the formation of the complex in an open circuit, and the resulting surface was characterized by medium exchange, electrochemical reduction, and differential pulse voltammetry. Various experimental parameters, such as the composition of modifier, preconcentration time, pH of electrolyte (0.1 M acetate buffer), and parameters of differential pulse voltammetry, were optimized. The initial potential was applied for 50 s, the electrode was scanned from -0.9 to -0.3 V, and the anodic peak current was measured at -0.604 V $\pm$ 0.015 V (vs. Ag/AgCl). The calibration plot was obtained in the range 1.0$\times$10$^{-8}$ M~l.0$\times$10$^{-6}$ M with pH 4.5 buffer solution. The detection limit (3$\sigma$) it as low as 5.0$\times$ 10$^{-9}$ M. This method is applied to the determination of lead(II) in a certified reference material and the result agrees satisfactorily with the certified value.

Comparison of Clinical Laboratory Data and Prevalence according to Arterial Stiffness in Stroke Patients

  • Jin, Bok Hee;Han, Min Ho
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.46 no.4
    • /
    • pp.143-149
    • /
    • 2014
  • Pulse wave velocity (PWV) is used to non-invasively estimate the severity of arteriosclerosis by measuring the patient's arterial stiffness comparing with each normal reference range according to their ages. Increased arterial stiffness is closely related to both atherosclerosis and arteriosclerosis, which have been known for causes of cardiovascular disease and stroke, also negatively affects the prognosis and the re-occurrence in patients with stroke. The study is focused on how brachial-ankle pulse wave velocity (baPWV) is related to cardiovascular disease risk factors in patients with acute stroke. There were 114 subjects, 69 males and 45 females, all in their 60's and had PWV test for acute stroke. The results are as follows: the group with increased arterial stiffness showed significant increase in HbAlc, total cholesterol, RSBP (resting systolic blood pressure), CSBP (central systolic blood pressure) and CDBP (central diastolic blood pressure). Cross tabulation test showed that there was a significant relationship only between the group with increased arterial stiffness and diabetes mellitus (DM). Therefore, it might be useful for preventing re-occurrence and making a favorable prognosis to promptly adjust DM and hypertension-related risk factors in patients with acute stroke.

Analysis and Implementation of PS-PWAM Technique for Quasi Z-Source Multilevel Inverter

  • Seyezhai, R.;Umarani, D.
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.2
    • /
    • pp.688-698
    • /
    • 2018
  • Quasi Z-Source Multilevel Inverter (QZMLI) topology has attracted grid connected Photovoltaic (PV) systems in recent days. So there is a remarkable research thrust in switching techniques and control strategies of QZMLI. This paper presents the mathematical analysis of Phase shift- Pulse Width Amplitude Modulation (PS-PWAM) for QZMLI and emphasizes on the advantages of the technique. The proposed technique uses the maximum and minimum envelopes of the reference waves for generation of pulses and proportion of it to generate shoot-through pulses. Hence, it results in maximum utilization of input voltage, lesser switching loss, reduced Total Harmonic Distortion (THD) of the output voltage, reduced inductor current ripple and capacitor voltage ripple. Due to these qualities, the QZMLI with PS-PWAM emerges to be the best suitable for PV based grid connected applications compared to Phase shift-Pulse Width Modulation (PS-PWM). The detailed math analysis of the proposed technique has been disclosed. Simulation has been performed for the proposed technique using MATLAB/Simulink. A prototype has been built to validate the results for which the pulses were generated using FPGA /SPARTAN 3E.

Design of Direct Drive AC Motor Position Controller Using DSP (DSP를 이용한 직접구동형 AC모터 위치제어기의 설계)

  • Park, Sung-Un;Kim, Kab-Il;Lee, Kwang-Mu;Lee, Chang-Sup;Jang, Tae-Sung
    • Proceedings of the KIEE Conference
    • /
    • 1995.07b
    • /
    • pp.846-848
    • /
    • 1995
  • Recently, direct drive AC servo motor and DSP is widely used in the factory automation and related field due to the enhanced control and digital technology. In this paper, position control of direct drive AC servo motor and numerical interpolation algorithms are studied using DSP for the future applications. In the direct drived motor control, encoder pulse is divided into the quadruple pulse for the higher resolution and high speed pulse(10MHz) is used as reference for the slower speed motor control (M/T method). As for the general position control, PI controller is adapted for position control. In the trajectory tracking numerical algorithm, interpolation of straight line and curve algorithms are studied for the realization of path following capabilities of XY table. As for the DSP, ADSP 2105 is selected for the economy and performance points of view.

  • PDF

A Study on BEM-Based Numerical Simulation Technique for Underwater Explosions (수중 폭발 시뮬레이션을 위한 경계 요소법 기반의 수치 해석 기법 연구)

  • Choung, Joonmo;Lee, Jae-bin
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.57 no.5
    • /
    • pp.271-277
    • /
    • 2020
  • Recoverability and vulnerability of navy ships under underwater explosion are critical verification factors in the acquisition phase of navy ships. This paper aims to establish numerical analysis techniques for the underwater explosion of navy ships. Doubly Asymptotic Approach (DAA) Equation of Motion (EOM) of primary shock wave and secondary bubble pulse proposed by Geers-Hunter was introduced. Assuming a non-compressive fluid, reference solution of the DAA EOM of Geers-Hunter using Runge-Kutta method was derived for the secondary bubble pulse phase with an assumed charge conditions. Convergence analyses to determine fluid element size were performed, suggesting that the minimum fluid element size for underwater explosion analysis was 0.1 m. The spherical and cylindrical fluid domains were found to be appropriate for the underwater explosion analyses from the fluid domain shape study. Because the element size of 0.1 m was too small to be applied to the actual navy ships, a very slender beam with the square solid section was selected for the study of fluid domain existence effect. The two underwater explosion models with/without fluid domain provided very similar results in terms of the displacement and stress processes.