• Title/Summary/Keyword: reference parameter

Search Result 845, Processing Time 0.049 seconds

An Inductance Voltage Vector Control Strategy and Stability Study Based on Proportional Resonant Regulators under the Stationary αβ Frame for PWM Converters

  • Sun, Qiang;Wei, Kexin;Gao, Chenghai;Wang, Shasha;Liang, Bin
    • Journal of Power Electronics
    • /
    • v.16 no.3
    • /
    • pp.1110-1121
    • /
    • 2016
  • The mathematical model of a three phase PWM converter under the stationary αβ reference frame is deduced and constructed based on a Proportional-Resonant (PR) regulator, which can replace trigonometric function calculation, Park transformation, real-time detection of a Phase Locked Loop and feed-forward decoupling with the proposed accurate calculation of the inductance voltage vector. To avoid the parallel resonance of the LCL topology, the active damping method of the proportional capacitor-current feedback is employed. As to current vector error elimination, an optimized PR controller of the inner current loop is proposed with the zero-pole matching (ZPM) and cancellation method to configure the regulator. The impacts on system's characteristics and stability margin caused by the PR controller and control parameter variations in the inner-current loop are analyzed, and the correlations among active damping feedback coefficient, sampling and transport delay, and system robustness have been established. An equivalent model of the inner current loop is studied via the pole-zero locus along with the pole placement method and frequency response characteristics. Then, the parameter values of the control system are chosen according to their decisive roles and performance indicators. Finally, simulation and experimental results obtained while adopting the proposed method illustrated its feasibility and effectiveness, and the inner current loop achieved zero static error tracking with a good dynamic response and steady-state performance.

Estimation of Leak Frequency Function by Application of Non-linear Regression Analysis to Generic Data (비선형 회귀분석을 이용한 Generic 데이터 기반의 누출빈도함수 추정)

  • Yoon, Ik Keun;Dan, Seung Kyu;Jung, Ho Jin;Hong, Seong Kyeong
    • Journal of the Korean Society of Safety
    • /
    • v.35 no.5
    • /
    • pp.15-21
    • /
    • 2020
  • Quantitative risk assessment (QRA) is used as a legal or voluntary safety management tool for the hazardous material industry and the utilization of the method is gradually increasing. Therefore, a leak frequency analysis based on reliable generic data is a critical element in the evolution of QRA and safety technologies. The aim of this paper is to derive the leak frequency function that can be applied more flexibly in QRA based on OGP report with high reliability and global utilization. For the purpose, we first reviewed the data on the 16 equipments included in the OGP report and selected the predictors. And then we found good equations to fit the OGP data using non-linear regression analysis. The various expectation functions were applied to search for suitable parameter to serve as a meaningful reference in the future. The results of this analysis show that the best fitting parameter is found in the form of DNV function and connection function in natural logarithm. In conclusion, the average percentage error between the fitted and the original value is very small as 3 %, so the derived prediction function can be applicable in the quantitative frequency analysis. This study is to contribute to expand the applicability of QRA and advance safety engineering as providing the generic equations for practical leak frequency analysis.

Calculation of Effective Dose on Domestic Chest PA X-ray Examinations (국내 흉부 X-선 검사에 따른 유효선량 계산)

  • Choi, Seokyoon
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.7
    • /
    • pp.827-832
    • /
    • 2018
  • Research on effective dose analysis of actual conditions of use based on large data is scarce. In this study, the exposure conditions of Chest X-Ray examinations used by 324 medical institutions in Korea were calculated and evaluated using computer simulations. As a result of the experiment, the effective dose in the low energy parameter bands was 0.024 mSv, followed by spleen, adrenal glands, and lung. The effective dose in the high-energy exposure parameter band was 0.123 mSv, followed by height, spleen and adrenal glands. The effective dose was 0.017 mSv when the optimal conditions considered the quality and exposure proposed in Park's study were used. The results of the study will be a reference for chest X-rays and will help reduce patient exposure.

Dynamic instability region analysis of sandwich piezoelectric nano-beam with FG-CNTRCs face-sheets based on various high-order shear deformation and nonlocal strain gradient theory

  • Arefi, Mohammad;Pourjamshidian, Mahmoud;Arani, Ali Ghorbanpour
    • Steel and Composite Structures
    • /
    • v.32 no.2
    • /
    • pp.157-171
    • /
    • 2019
  • In this research, the dynamic instability region (DIR) of the sandwich nano-beams are investigated based on nonlocal strain gradient elasticity theory (NSGET) and various higher order shear deformation beam theories (HSDBTs). The sandwich piezoelectric nano-beam is including a homogenous core and face-sheets reinforced with functionally graded (FG) carbon nanotubes (CNTs). In present study, three patterns of CNTs are employed in order to reinforce the top and bottom face-sheets of the beam. In addition, different higher-order shear deformation beam theories such as trigonometric shear deformation beam theory (TSDBT), exponential shear deformation beam theory (ESDBT), hyperbolic shear deformation beam theory (HSDBT), and Aydogdu shear deformation beam theory (ASDBT) are considered to extract the governing equations for different boundary conditions. The beam is subjected to thermal and electrical loads while is resting on Visco-Pasternak foundation. Hamilton principle is used to derive the governing equations of motion based on various shear deformation theories. In order to analysis of the dynamic instability behaviors, the linear governing equations of motion are solved using differential quadrature method (DQM). After verification with validated reference, comprehensive numerical results are presented to investigate the influence of important parameters such as various shear deformation theories, nonlocal parameter, strain gradient parameter, the volume fraction of the CNTs, various distributions of the CNTs, different boundary conditions, dimensionless geometric parameters, Visco-Pasternak foundation parameters, applied voltage and temperature change on the dynamic instability characteristics of sandwich piezoelectric nano-beam.

Analysis of fMRI Signal Using Independent Component Analysis (Independent Component Analysis를 이용한 fMRI신호 분석)

  • 문찬홍;나동규;박현욱;유재욱;이은정;변홍식
    • Investigative Magnetic Resonance Imaging
    • /
    • v.3 no.2
    • /
    • pp.188-195
    • /
    • 1999
  • The fMRI signals are composed of many various signals. It is very difficult to find the accurate parameter for the model of fMRI signal containing only neural activity, though we may estimating the signal patterns by the modeling of several signal components. Besides the nose by the physiologic motion, the motion of object and noise of MR instruments make it more difficult to analyze signals of fMRI. Therefore, it is not easy to select an accurate reference data that can accurately reflect neural activity, and the method of an analysis of various signal patterns containing the information of neural activity is an issue of the post-processing methods for fMRI. In the present study, fMRI data was analyzed with the Independent Component Analysis(ICA) method that doesn't need a priori-knowledge or reference data. ICA can be more effective over the analytic method using cross-correlation analysis and can separate the signal patterns of the signals with delayed response or motion related components. The Principal component Analysis (PCA) threshold, wavelet spatial filtering and analysis of a part of whole images can be used for the reduction of the freedom of data before ICA analysis, and these preceding analyses may be useful for a more effective analysis. As a result, ICA method will be effective for the degree of freedom of the data.

  • PDF

Improvement of the Accuracy of Wrist Noninvasive Blood Pressure Measurement Using Multiple Bio-signals (다중 생체 신호를 통한 손목 혈압 측정의 정확도 향상)

  • Jung, Woon-Mo;Sim, Myeong-Heon;Jung, Sang-O;Kim, Min-Yong;Yoon, Chan-Sol;Jung, In-Chol;Yoon, Hyung-Ro
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.8
    • /
    • pp.1606-1616
    • /
    • 2011
  • The blood pressure measuring equipment, which is being supplied and used most widely by being recognized convenience and accuracy now generally, is oscillometric blood pressure monitor. However, a change in blood pressure is basically influenced by diverse elements such as each individual's physiological status and physical condition. Thus, the measurement of blood pressure, which used single element called oscillation in blood pressure of being conveyed to cuff, is not considered on physiological elements such as cardiovascular system status and blood vessel stiffness index, and on external elements, thereby being quite in error. Accordingly, this study detected diverse bio-signals and body informations in each individual as the measurement subject such as ECG, PPG, and Korotkoff Sound in order to enhance convenience and accuracy of measuring blood pressure in the complex measurement equipment, thereby having extracted regression method for compensation in error of oscillometric blood pressure measurement on the wrist, and having improved accuracy of measuring blood pressure. To verify a method of improving accuracy, the blood pressure value in each of SBP, DBP, MAP was acquired through 4-stage experimental procedure targeting totally 51 subjects. Prior to experiment, the subjects were divided into two groups such as the experimental group for extracting regression method and the control group for verifying regression method. Its error was analyzed by comparing the reference blood pressure value, which was obtained through the auscultatory method, and the oscillometric blood pressure value on the wrist. To reduce the detected error, the blood pressure compensation regression method was calculated through multiple linear regression analysis on elements of blood pressure, individual body information, PTT, HR, K-Sound PSD change. Verification was carried out on improving significance and accuracy by applying the regression method to the data of control group. In the experimental results, as a result of confirming error on the reference blood pressure value in SBP, DBP, and MAP, which were acquired through applying regression method, the results of $-0.47{\pm}7.45$ mmHg, $-0.23{\pm}7.13$ mmHg, $0.06{\pm}6.39$ mmHg could be obtained. This is not only the numerical value of satisfying the sphygmomanometer reference of AAMI, but also shows the lower result than the numerical value in SBP : $-2.5{\pm}12.2$ mmHg, DBP : $-7.5{\pm}8.4$ mmHg, which is the mean error in the experimental results of Brram's research for verifying accuracy of Omron RX-M, which shows relatively high accuracy among wrist sphygmomanometers. Thus, the blood pressure compensation could be confirmed to be made within significant level.

A Cell Phone-based ECG, Blood Pressure Monitoring System for Personal Healthcare Applications using Wireless Sensor Network Technology

  • Toh, Sing-Hui;Lee, Seung-Chul;Chung, Wan-Young
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2008.05a
    • /
    • pp.505-508
    • /
    • 2008
  • Electrocardiogram (ECG) and blood pressure (BP) are main vital signs which are the standards in most medical settings in assessing the most basic body functions. Multi parameters are desired in providing more information for health professionals in order to detect or monitor medical problems of patients more precisely. This study urges us to develop a robust wireless healthcare monitoring system which has multiple physiological signs measurements on real time that applicable to various environments which integrates wireless sensor network technology and code division multiple access (CDMA) network with extended feature of locally standalone diagnosis algorithms that implemented in tell phone. ECG signal and BP parameter of the patients are routinely be monitored, processed and analyzed in details at cell phone locally to produce useful medical information to ease patients for tracking and future reference purposes. Any suspected or unknown patterns of signals will be immediately forwarded to hospital server using cell phone for doctors' evaluation. This feature enables the patients always recognize the importance of self-health checking so that the preventive actions can be taken earlier through this analytic information provided by this monitoring system because "Prevention is better than Cure".

  • PDF

Study on Dynamic Characteristic and Safety of 45m Steel Box Railway Bridge according to Girder hight and Ballast (강상형 철도교의 도상종류와 형고에 따른 동특성 및 안정성 연구)

  • Yun, Ji-Hong;Choi, Kwon-Young;Kwon, Ku-Sung;An, Ju-Ok;Chung, Won-Seok
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.3147-3155
    • /
    • 2011
  • Railway bridges are highly susceptible to resonance due to the equidistant axle load with constant speed of train. Thus, it is inevitable verify dynamic characteristics and quantities against dynamic guidelines. Recently, various new-type bridges are developed and applies to medium span length between 30m and 40m. However, just steel box girder bridge is under review for span length between 45m and 50m without development any new technologies. This study investigate the dynamic properties and safety of steel box railway bridge having span length 45m in alternative girder hight and kind of ballast. Numerical analysis is performed time series analysis by mode superposition using calculated natural vibration frequency and mode after carry out a free vibration analysis and extract modal parameter to higher modes. The results are then compared to various dynamic stability standards toward target bridge's dynamic stability analysis. The result of this study is expected as a reference for design railway bridges.

  • PDF

Implementation and Validation of Earth Acquisition Algorithm for Communication, Ocean and Meteorological Satellite

  • Park, Sang-Wook;Lee, Young-Ran;Lee, Byoung-Sun;Hwang, Yoo-La;Lee, Un-Seob
    • Journal of Astronomy and Space Sciences
    • /
    • v.28 no.4
    • /
    • pp.345-354
    • /
    • 2011
  • Earth acquisition is to solve when earth can be visible from satellite after Sun acquisition during launch and early operation period or on-station satellite anomaly. In this paper, the algorithm and test result of the Communication, Ocean and Meteorological Satellite (COMS) Earth acquisition are presented in case of on-station satellite anomaly status. The algorithms for the calculation of Earth-pointing attitude control parameters including those attitude direction vector, rotation matrix, and maneuver time and duration are based on COMS configuration (Eurostar 3000 bus). The coordinate system uses the reference initial frame. The constraint calculating available time-slot to perform the earth acquisition considers eclipse, angular separation, solar local time, and infra-red earth sensor blinding conditions. The results of Electronics and Telecommunications Research Institute (ETRI) are compared with that of the Astrium software to validate the implemented ETRI software.

A study on the adaptive method of control model for tandem cold rolling mill (연속냉간압연기 제어모델의 적응수정방법에 관한 연구)

  • Lee, Won-Ho;Lee, Sang-Ryong
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.21 no.7
    • /
    • pp.1030-1041
    • /
    • 1997
  • The control model in the tandem cold rolling mill consists of many mathematical theories and is used to calculate the reference values such as the roll gap and the rolling speed for good operation of rolling mill. But, the control model used presently has a problem causing inaccurate prediction of the rolling force. By the parameter identification, it was found that the main factor causing inaccurate prediction of the rolling force was incorrect modeling of the friction coefficient and the flow stress. To get rid of the erroneous factor new adaptive schemes are suggested in this work. Those are a long-time adaptation by the iterative least-square method and a short-time adaptation by the recursive weighted least-square method respectively. The new equations for the friction coefficient and the flow stress are derived by applying the suggested adaptive algorithms. Through the on-line test in an actual mill, it is proved that the rolling force predicted by the new equations is more accurate than the one by the existing equations ever used.