• Title/Summary/Keyword: reference parameter

Search Result 845, Processing Time 0.032 seconds

Analysis of the hazardous RoHS materials in polyethylene and polypropylene samples by bench-top and portable XRF methods (탁상형 및 휴대형 X-선 형광 분석기를 이용한 폴리에틸렌 및 폴리프로필렌 시료 중 RoHS 규제 물질의 비교 분석)

  • Choi, Soo-Jung;Kim, Chong-Hyeak;Lee, Sueg-Geun;Kang, In-Sung
    • Analytical Science and Technology
    • /
    • v.23 no.1
    • /
    • pp.74-82
    • /
    • 2010
  • As a basic research for development of the domestic portable XRF spectrometer, we discussed the analytical results of bench-top and portable XRF methods for RoHS materials of the Cd, Pb, Hg, Cr(IV), polybrominated biphenyls(PBB) and polybrominated diphenyl ehters(PBDE). The instrumental parameters such as measurement time of bench-top and portable XRF were optimized using certified reference materials of polyethylene and polypropylene with 5 hazardous materials of 0~1,200 mg/kg. The quantitative analysis of total-Cr, total-Br, Cd, Hg and Pb in certified reference materials and plastic samples were compared by empirical method, fundamental parameter method of bench-top XRF and portable XRF.

Adaptive Fuzzy Drop Manager for Service of Reliable Distribution Application Domain Objects (신뢰성 있는 분산 도메인 객체 서비스를 위한 적응형 퍼지 드럽 관리기)

  • Jeong, Taeg-Won;Lee, Chong-Deuk
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.19 no.4
    • /
    • pp.511-518
    • /
    • 2009
  • A lot of methods are proposed to provide services for object informations in distributed domain to satisfy the recent increase of user-centered services. This paper proposed a method called fuzzy drop manager for the service of reliable distribution application domain objects. The proposed system accesses the domain using replica parameter ci,j and access matrix Z, and evaluates the reference relatedness inside the domain using the relatedness, given by the mapping of intra-domain fuzzy relevance, between fuzzy sets. Objects in the domain generated an $\alpha$-level set according to the reference relatedness obtained by applying $\alpha$-level to extend queries. Simulation results showed that the proposed method has better performance than the other methods.

Bioequivalence of Cyclosporin A Hard Capsules (사이클로스포린 A 경질캅셀제에 대한 생물학적 동등성 평가)

  • 김종국;이은진;이미경;박준규;신희종;김인숙
    • Biomolecules & Therapeutics
    • /
    • v.6 no.3
    • /
    • pp.296-302
    • /
    • 1998
  • The bioequivalence of two cyclosporin A products was evaluated in 26 normal male volunteers (age 25 ~33 yr, body weight 56~84 kg) following single oral administration. Test product was a hard capsule containing the granule of cyclosporin A (Chong Kun Dang Corp., Korea) and reference product, Sandimmun", was a soft capsule containing surfactant, oil, alcohol and cyclosporin A (Sandoz, Swiss). Both products contain 100 mg of cyclosporin A. Four capsules of the test and the reference product were administered to the volunteers, respectively, by randomized two period cross-over study (2$\times$2 Latin square method). Average drug concentrations at each sampling time and pharmacokinetic parameters were not significantly different between two products (p>0.05); the area under the concentration-time curve to last sampling time (24 hr) (AU $Co_{24}$) (5034.8$\pm$ 1760.6 vs 4635.4$\pm$ 1158.9 ng . h/ml), maximum plasma concentration ( $C_{max}$) (1002.7$\pm$353.1 vs 980. 4$\pm$ 171.7 ng/71), and mean residence time (MRT) (6.16$\pm$0.81 vs 5.64$\pm$0.50 h). The differences of mean AUC 7-,4,7~, T_ and MRT between the two products (7.93,2.22,16 and 8.39%, respectively) were less than 20% given as a guideline. The power (1-$\beta$) and treatment difference ($\Delta$) for AU $Co_{24}$, $C_{max}$ and MRT were more than 0.8 and less than 0.2, respectively. Although $T_{max}$ of the two products was significantly different each other (p<0.05), $T_{max}$ might be an insignificant parameter because cyclosporin A generally requires long-term administration. From these results, the two products are bioequivalent.alent.t.

  • PDF

Measurements and Statistical Modeling of Ignition Noise from Vehicle (자동차 점화계통에서 발생된 전자파 잡음의 측정 및 통계적 모형)

  • 김종호;윤현보;백락준;우종우
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.8 no.4
    • /
    • pp.390-402
    • /
    • 1997
  • The ignition noises from the vehicle are measured and the measurement data are statistically treated for modeling. The low-noise amplifier and band-pass filter are added between the receiver and the three axes antenna for low noise level measurement and the APD and PSD are measured in 800 MHz frequency range. The measured APD curves can be expressed in terms of sensitivity study of each model through 3(class A) or 6(Class B) parameters variation, and these optimal parameter can easily be calculated by using the Composite Approximation Algorithm. The selected APD parameter can be used for making the Data Base EM-environments and also applied to determine the output and sensitivity margin for the transmitter and receiver. 'Digital microwave transmission systems are equipped with equalizer against fading during multipath fading. In this paper, we proposed variable reference tap position equalizer that varies the reference tap according to fading type to archive better performance. We got the perf?mance improvement about 4~5 dB in MP condition and 2~3 dB in NMP condition from simulation results.

  • PDF

Performance Comparison of VRS and FKP Network RTK User According to Baseline Length (기선 거리에 따른 VRS와 FKP 방식의 Network RTK 사용자 성능 비교)

  • Lim, Cheolsoon;Park, Byungwoon
    • Journal of Advanced Navigation Technology
    • /
    • v.24 no.6
    • /
    • pp.540-548
    • /
    • 2020
  • In this paper, the performances of virtual reference station (VRS) and flächen korrektur parameter (FKP) based Network real time kinematics (RTK) according to baseline length were compared and analyzed. We applied the VRS and FKP corrections for each baseline length obtained from National Geographic Information Institute Network RTK services to an FKP-supported commercial receiver and analyzed the RTK results in the range and position domains. In the case of VRS, RTK performance was degraded due to the spatial error, which increase in proportion of the baseline length. On the other hand, FKP compensates for spatial errors by using the gradients of dispersive and non-dispersive errors, so it showed stable RTK performance compared to VRS even if the baseline length increases up to 130 km. However, in the case of long baseline of 150 km or more, integer ambiguities were incorrectly fixed due to the decrease in the performance of the FKP corrections.

Comparison of the Heavy Metal Analysis in Soil Samples by Bench-Top ED-XRF and Field-Portable XRF (Bench-Top ED-XRF 및 휴대용 XRF를 이용한 토양 시료 중의 중금속 비교 분석)

  • Choi, Soo-Jung;Kim, Chong-Hyeak;Lee, Sueg-Geun
    • Analytical Science and Technology
    • /
    • v.22 no.4
    • /
    • pp.293-301
    • /
    • 2009
  • As a basic research for development of the domestic field-portable XRF spectrometer, we discussed the analytical results of bench-top ED-XRF and field-portable XRF method for polluted heavy metals such as Cr, As, Se, Hg, Pb, Cd in soil samples. To obtain the best performance of the XRF spectrometer, the instrumental parameters of X-ray tube-voltage and measurement time were optimized for 6 heavy-metal elements in soil using certified reference material. The quantitative analysis of Cr, As, Se, Hg, Pb, Cd concentration in certified reference materials and soil samples were compared by empirical method and fundamental parameter method.

Comparison study of the wear metal analysis in oil sample by portable and bench-top XRF (휴대용 및 Bench-Top X-선 형광 분석기를 이용한 오일 시료 중 마찰 금속의 비교 분석)

  • Choi, Soo-Jung;Kim, Chong-Hyeak;Lee, Sueg-Geun;Kim, Dong-Pyo
    • Analytical Science and Technology
    • /
    • v.22 no.5
    • /
    • pp.422-431
    • /
    • 2009
  • The analytical results of wear metals such as Na, Mg, Al, Si, P, Ca, Ti, V, Cr, Mn, Fe, Ni, Cu, Zn, Mo, Ag, Cd, Sn, Ba, Pb in oil samples are compared by portable and bench-top XRF methods as a basic study for the development of portable X-ray fluorescence spectrometer. The instrumental parameters such as measurement time of portable and bench-top XRF were optimized using certified reference materials of hydrocarbon oil with 20 wear metals in concentration range from 10 to 900 mg/kg. The analytical results of 20 wear metals in certified reference materials and new/used engine oil samples were compared by empirical and fundamental parameter methods.

A Design of Reference Model Following Fuzzy Control System for Boiler-Turbine Equipment (보일러-터빈 설비에 대한 기준모델 추종 퍼지 제어시스템의 설계)

  • 정호성;황창선;황현준
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.11 no.4
    • /
    • pp.82-91
    • /
    • 1997
  • In this paper, a design method of the boiler-turbine control system in the coal fired power plant is proposed. We need to control electric output and drum pressure and water level in drum to guarantee stable operation and save energy for generating electricity and decrease air pollution in the boiler-turbine system. This boiler-turbine control system is composed of reference model part and model following part. The multivariable boiler-turbine system is separated into 3 SISO(Single Input Single Output) systems applying the concept of relative gain matrix. Each 3 reference models for separated boiler-turbine system are composed of 1st order nominal plant and hysteresis integral control system and they make good dy¬namic response with no overshoot and fast rising time. Each fuzzy controller to follow as close as possible to the response of each reference model is designed. The robustness and the good tracking property can be achieved using 5150 fuzzy controllers when there are modeling errors, disturbances and parameter pertur¬bations. The effectiveness of the proposed design method is verified through simulations.

  • PDF

Effect of the Sensor Location on Magnetocardiography (심자도 센서의 위치 효과에 대한 연구)

  • Lim, Hyun-Kyoon;Kim, Ki-Woong;Kwon, Hyuk-Chan;Lee, Yong-Ho
    • Progress in Superconductivity
    • /
    • v.10 no.1
    • /
    • pp.1-5
    • /
    • 2008
  • Magnetocardiography (MCG) is a non-contact, non-invasive, and harmless diagnostic tool to detect the abnormal electrical conductivities of the heart caused by the various coronary artery disease or cardiac muscular disease. The purpose of this study is to identify whether MCG signals and MCG parameter values vary depending on the location of sensor assembly. It will be an important reference for the standard measurement. Four healthy male subjects (33.3$\pm$6.3 years) participated in this study. Basal recording was made at 20 mm apart from the chest surface. All subjects were requested to take a regular breathe while MCG was taken. The gap between the chest surface and the bottom of the sensor assembly was 20, 40, 60, and 80 mm. Recording was made using 64 channel MCG system (Axial type, first order gradiometer) developed by Korea Research Institute of Standards and Science (KRISS). After resting for two minutes in a supine position on the bed in magnetically shielded room, MCG were recorded for 30 s. As the sensor location is getting away from the chest surface signal, the amplitude of R and T wave peak decreases to 70% (at 40 mm gap), 50% (at 60 mm), and 37% (at 80 mm) of the reference strength measured (y = $1.3903e^{-0.0169x}$, $R^2$ = 0.99; where y=amplitude remained after reduction, x=distance between chest surface and sensor location). The regression equations may be used as a good reference to calculate how much strength will be decreased by the distance. In MCG parameters, most values of parameters were decreased as the gap was increased. As an example, the current moment at T-wave peak reduced to 52% (at 40 mm gap), 33% (at 60 mm), and 19% (at 80 mm). However, the difference caused by the gap could be reduced by considering the distance when the MCG parameters were calculated. The study results can be used as a useful reference to design the baseline and the sensor location.

  • PDF

Dual-mode CMOS Current Reference for Low-Voltage Low-Power (저전압 저전력 듀얼 모드 CMOS 전류원)

  • Lee, Geun-Ho
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.14 no.4
    • /
    • pp.917-922
    • /
    • 2010
  • In this paper, a new temperature-insensitive CMOS dual-mode current reference for low-voltage low-power mixed-mode circuits is proposed. The temperature independent reference current is generated by summing a proportional to absolute temperature(PTAT) current and a complementary to absolute temperature(CTAT) current. The temperature insensitivity was achieved by the mobility and the other which is inversely proportional to mobility. As the results, the temperature dependency of output currents was measured to be $0.38{\mu}A/^{\circ}C$ and $0.39{\mu}A/^{\circ}C$, respectively. And also, the power dissipation is 0.84mW on 2V voltage supply. These results are verified by the $0.18{\mu}m$ n-well CMOS parameter.