• Title/Summary/Keyword: reference link

Search Result 287, Processing Time 0.028 seconds

Safety Evaluation of Carbon Fiber/Epoxy Composite Link Using Micromechanics of Failure Criterion (미시역학적 파손 기준을 이용한 탄소섬유/에폭시 복합재 링크의 안전성 평가)

  • Jae Ho Cha;Sung Ho Yoon
    • Composites Research
    • /
    • v.36 no.3
    • /
    • pp.154-161
    • /
    • 2023
  • This study explored the feasibility of replacing a metal link with a carbon fiber/epoxy composite link and assessed its capacity to withstand a given load condition using failure criteria. The micromechanics of failure (MMF) criterion was employed to predict the failure mode of the composite material, and mechanical tests were conducted to obtain reference strength parameters for MMF. The findings revealed that the stress distribution was concentrated near the hole, and weaknesses were found around the hole and at the end of the link under bending conditions. Based on the failure index, matrix tensile failure was predicted at the end of the link, and fiber compression failure occurred near the hole. The methods and results obtained from this study can provide valuable guidelines for assessing the safety of composite materials under specific load conditions when replacing metal parts with carbon fiber/epoxy composites to achieve weight reduction.

A SES Alarmed Link Encryption Synchronization Method Having Optimized Threshold Value for High-Speed Video Data Encryption

  • Kim, Hyeong-Rag;Lee, Hoon-Jae;Kim, Ki-Hwan;Jung, Ju-Hyun
    • Journal of the Korea Society of Computer and Information
    • /
    • v.22 no.9
    • /
    • pp.57-64
    • /
    • 2017
  • CCSDS Standard is widely used in the international space telecommunication area. But standard recommendation of CCSDS is not restrictive, so, we can select an appropriate encryption protocol among the layer. For synchronization, encryption sync is attached in the beginning of the encrypted data. In the exceptional environmental condition, although the receiver can not decrypt the normal data, the sender have no conception of that situation. In this paper, we propose a two-stage SES alarmed link encryption synchronization method having optimized threshold value necessary to decide whether the receiver has a correct decryption or not. first, through the experiment of mutual relations between error rate and encryption synchronization detection error, we can predict worst communication environment for the selected encryption synchronization pattern. second, through the experiment for finding what number of consecutive frame synchronization error is an appropriate reference value and analysis of that experiment, we suggest an optimized threshold value for resynchronization request. lastly, through the output images we can predict the probability error that should be guaranteed by channel coder.

PFC Bridge Converter for Voltage-controlled Adjustable-speed PMBLDCM Drive

  • Singh, Sanjeev;Singh, Bhim
    • Journal of Electrical Engineering and Technology
    • /
    • v.6 no.2
    • /
    • pp.215-225
    • /
    • 2011
  • In this paper, a buck DC-DC bridge converter is used as a power factor correction (PFC) converter for feeding a voltage source inverter (VSI) based permanent magnet brushless DC motor (PMBLDCM) drive. The front end of the PFC converter is a diode bridge rectifier (DBR) fed from single phase AC mains. The PMBLDCM is used to drive the compressor of an air conditioner through a three-phase voltage source inverter (VSI) fed from a variable voltage DC link. The speed of the air conditioner is controlled to conserve energy using a new concept of voltage control at a DC link proportional to the desired speed of the PMBLDC motor. Therefore, VSI operates only as an electronic commutator of the PMBLDCM. The current of the PMBLDCM is controlled by setting the reference voltage at the DC link as a ramp. The proposed PMBLDCM drive with voltage control-based PFC converter was designed and modeled. The performance is simulated in Matlab-Simulink environment for an air conditioner compressor load driven through a 3.75 kW, 1500 rpm PMBLDC motor. To validate the effectiveness of the proposed speed control scheme, the evaluation results demonstrate improved efficiency of the complete drive with the PFC feature in a wide range of speed and input AC voltage.

Plug-in BLDC Control System using DC-link Communication (DC 전력선 통신을 이용한 Plug-in형 BLDC 구동 시스템)

  • Yu, Tao;Song, Doo-Young;Choi, Joon-Ho;Moon, Chae-Joo;Cho, Su-Eog;Park, Sung-Jun
    • Proceedings of the KIPE Conference
    • /
    • 2008.06a
    • /
    • pp.592-594
    • /
    • 2008
  • The powers used in the robot drive motor system are mostly DC sources such as batteries. Even AC powers in some systems are generated from DC sources by the inverter. It is can be forecasted that the DC-link communications will be widely used invarious industrial application. In this paper a novel BLDC motor drive system by using DC-link communications is proposed. The characteristic of this system is the communication only needs 2 DC lines. There are not additional lines to translate the reference signals and the reliability of the system is enhanced especially in some badly circumstance. The number of lines can be least when applied in the multi motor control system and the slip ring design can be simplified when applied as rotation machine. The reasonableness of proposed motor system is clarified by the PSIM simulation and the hardware prototype.

  • PDF

Switch Open Fault Detection and Tolerant Operation Method for Three Phase PWM Rectifier (3상 PWM 정류기의 스위치 개방 고장 감지 및 허용운전 방법)

  • Shin, Hee-Keun;An, Byoung-Woong;Kim, Hag-Wone;Cho, Kwan-Yuhl;Jung, Shin-Myung
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.17 no.3
    • /
    • pp.266-273
    • /
    • 2012
  • In this paper, the new open fault detection and tolerant operation method for 3 phase PWM rectifier is proposed. When open fault occurred on the inverter switches of 3 Phase PWM rectifier, the DC link voltage ripple is increased because the input current of the faulty phase is distorted. In this case, the quality of electric power would decrease, and the life time of DC link capacitor is decreased. The open fault is detected by a simple MRAS(Model Reference Adaptive System) without additional hardware sensors, and the tolerant operation carried out by turning on the opposite switch of the faulty switch without any redundancy. By the proposed method, the faulty phase input current can be controlled, so that 3-phase input current is balanced relatively under the faulty condition and the voltage ripple of DC link output is reduced. The validity of the proposed technique is proved on the 6kW 3-phase PWM rectifier system by simulation and experiment.

Robust Force Control of a 6-Link Electro-Hydraulic Manipulator (전기 유압 매니플레이터의 강건 힘 제어)

  • Ahn, Kyoung-Kwan;Cho, Yong-Rae;Yang, Soon-Yong;Lee, Byung-Ryong
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.19 no.4
    • /
    • pp.202-208
    • /
    • 2002
  • An electro-hydraulic manipulator using hydraulic actuators has many nonlinear elements, and its parameter fluctuations are greater than those of an electrically driven manipulator. So it is relatively difficult to realize not only stable contact work but also accurate force control for the autonomous assembly tasks using hydraulic manipulators. In this report, we applied a compliance control which is based on the position control by a disturbance observer for our manipulator system. And a reference trajectory modification method is proposed in order to achieve accurate force control even though the stiffness and position of environment change. Experimental results show that highly robust force tracking by a 6-link electro-hydraulic manipulator could be achieved under various environment conditions.

Analytical computation of the reerse link interference iwht unequal cell loading in CDMA system (CDMA 시스템에서의 불균일한 통화량 분포를 고려한 역방향 링크 간섭 계산)

  • 정경수;오종택;강충구;차균현
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.23 no.4
    • /
    • pp.901-913
    • /
    • 1998
  • This paper presents a new analytical approach for the evaluation of the reverse link interference in a CDMA cellular system with unequal cell loading. In particular, the dynamic nature of the reverse link power control has been taken into account in the proposed approach so that a realistic effect of unequal cell loading, including the shadowing and soft handoff, on system capacity may be precisely captured. This is aspect that has not beensuccessfully formmulated and rarely attempted tosolve in any previous analytical approach. Our computational result shows that as the loading of every tier of surrounding cells is doubled, the subscriber capacity of the reference cell can be reduced as much as 27% of that obtained in the case that the effect of power control is not appropriately modeled.

  • PDF

Design of Control System for 1kW Grid-connected Permanent Magnet Synchronous Generator (가스 엔진용 1kW급 계통 연계 영구자석형 동기발전기 구동 시스템 설계)

  • Lee, Taeyeong;Cho, Younghoon
    • Proceedings of the KIPE Conference
    • /
    • 2017.11a
    • /
    • pp.69-70
    • /
    • 2017
  • This paper presents design of control system for permanent magnet synchronous generator(PMSG). The gas engine make rotating mechanical energy from gas fuel energy. The rotor of synchronous generator is connected to axis of engine. And it converts the mechanical energy to the electrical energy. The control system of PMSG helps the electrical energy to flow to grid. the single phase pfc rectifier controls the DC-link voltage by controlling the current of filter inductor. If the DC-link voltage is higher than the voltage reference, the filter current could be controlled to flow to grid. The three phase inverter controls the stator current of generator. The direction of the current is controlled depends on motoring or generating mode. The feasibility of the grid-connected PMSG is verified by the experimental results with 1kW prototype.

  • PDF

Compensation of Current Offset Error in Half-Bridge PWM Inverter for Linear Compressor

  • Kim, Dong-Youn;Im, Won-Sang;Hwang, Seon-Hwan;Kim, Jang-Mok
    • Journal of Power Electronics
    • /
    • v.15 no.6
    • /
    • pp.1593-1600
    • /
    • 2015
  • This paper proposes a novel compensation algorithm of current offset error for single-phase linear compressor in home appliances. In a half-bridge inverter, current offset error may cause unbalanced DC-link voltage when the DC-link is comprised of two serially connected capacitors. To compensate the current measurement error, the synchronous reference frame transformation is used for detecting the measurement error. When an offset error occurs in the output current of the half-bridge inverter, the d-axis current has a ripple with frequency equal to the fundamental frequency. With the use of a proportional-resonant controller, the ripple component can be removed, and offset error can be compensated. The proposed compensation method can easily be implemented without much computation and additional hardware circuit. The validity of the proposed algorithm is verified through experimental results.

Sliding Mode Control of 5-link Biped Robot Using Wavelet Neural Network

  • Kim, Chul-Ha;Yu, Sung-Jin;Park, Jin-Bae;Choi, Yoon-Ho
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.2279-2284
    • /
    • 2005
  • Generally, biped walking is difficult to control because it is a nonlinear system with various uncertainties. In this paper, we design a robust control system based on sliding-mode control (SMC) of 5-link biped robot using the wavelet neural network(WNN), in order to improve the efficiency of position tracking performance of biped locomotion. In our control system, the WNN is utilized to estimate uncertain and nonlinear system parameters, where the weights of WNN are trained by adaptive laws that are induced from the Lyapunov stability theorem. Finally, the effectiveness of the proposed control system is verified by computer simulations.

  • PDF