• Title/Summary/Keyword: reference frequency transmission

Search Result 75, Processing Time 0.033 seconds

Estimation of Fault Location on a Transmission Line via Time-Frequency Domain Reflectometry (시간-주파수 반사파 계측 방법을 이용한 전송선로의 결함 위치 추정)

  • Choe TokSon;Kwak Ki-Seok;Yoon Tae Sung;Park Jin Bae
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.54 no.9
    • /
    • pp.521-530
    • /
    • 2005
  • In this paper, a new high resolution reflectometry scheme, time-frequency domain reflectometry(TFDR), isproposed to detect and estimate a fault in a transmission line. Traditional reflectometry methodologies have been achieved either in the time domain or in the frequency domain only. However, the TFDR can jump over the performance limits of the traditional reflectometry methodologies because the acquired signal is analyzed in time and frequency domain simultaneously. In the TFDR, the new reference signal and the novel TFDR algorithm are proposed for analyzing the acquired signal in the time-frequency domain. Because the reference signal of Gaussian envelop chirp signal is localized in the time and frequency domain simultaneously, it is suitable to the analysis in the time-frequency domain. In the proposed TFDR algorithm, the time-frequency distribution function and the normalized time-frequency cross correlation function are used to detect and estimate a fault in a transmission line. That algorithm is verified for real-world coaxial cables which are typical transmission line with different types of faults by the TFDR system composed of real instruments. The performance of the TFDR methodology is compared with that o( the commercial time domain reflectomeoy(TDR) experiments, so that concludes the TFDR methodology can detect and estimate the fault with smaller error than TDR methodology.

A Low-Noise and Small-Size DC Reference Circuit for High Speed CMOS A/D Converters

  • Hwang, Sang-Hoon;Song, Min-Kyu
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.7 no.1
    • /
    • pp.43-50
    • /
    • 2007
  • In a high-speed flash style or a pipelining style analog-to-digital converter (A/D converter), the DC reference fluctuation caused by external noises becomes serious, as the sampling frequency is increased. To reduce the fluctuations in conventional A/D converters, capacitors have been simply used, but the layout area was large. Instead of capacitors, a low-noise and small-size DC reference circuit based on transmission gate (TG) is proposed in this paper. In order to verify the proposed technique, we designed and manufactured a 6-bit 2GSPS CMOS A/D converter. The A/D converter is designed with a 0.18um 1-poly 6-metal n-well CMOS technology, and it consumes 145mW at 1.8V power supply. It occupies the chip area of 977um by 1040um. The measured result shows that SNDR is 36.25 dB and INL/DNL is within 0.5LSB, even though the DC reference fluctuation is serious.

Assessment of Magnetic Field Mitigation and Electrical Environmental Effects for Commercially Operating 154kV Transmission Lines with Passive Loop

  • Lee, Byeong-Yoon;Myung, Sung-Ho;Ju, Mun-No;Cho, Yeun-Gyu;Lee, Dong-Il;Lim, Yun-Seog;Kim, Sang-Beom
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.3
    • /
    • pp.991-996
    • /
    • 2014
  • Power frequency magnetic field is still a critical problem for new construction of overhead power transmission lines in Korea because most people have been concerned about possibly carcinogenic effects of it. Although reference level of power frequency(60Hz) magnetic field has been set to 200uT in ICNIRP guidelines published in 2010, Korean government has no intention of adjusting 83.3uT specified by law in 2006 to this new reference level in consideration of people's concerns for the time being. Regardless of the current regulated magnetic field value, electric utility company has been trying to reduce magnetic field in the residential area in the vicinity of overhead power transmission lines to take into account of public concerns on the long-term effect of magnetic fields. In an effort to reduce magnetic field, engineering side has made considerable efforts to develop passive loop based, cost-effective mitigation technique of power frequency magnetic field more than ten years. In order to verify developed power frequency magnetic field mitigation technique based on passive loop, a horizontal type of passive loop was designed and installed for commercially operating 154kV overhead power transmission line for the first time in Korea. The measurement results before and after the installation of passive loop showed that magnetic field could be reduced to about 20%. The electrical environmental effects such as AN, RI and TVI were assessed before and after the installation of passive loop and these values were complied with the requirements specified by electric utility. It has been confirmed from the field test results that passive loop could be commercially and cost-effectively utilized to mitigate power frequency magnetic field.

Reference Signal Design of TFDR for Low Voltage Power Transmission Line (저압배선의 이상 진단을 위한 시간-주파수영역 반사파계측 방법의 기준신호 설계기법 연구)

  • Lee, Chun-Ku;Kwak, Ki-Seok;Park, Jin-Bae;Yoon, Tae-Sung
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1543-1544
    • /
    • 2008
  • In this paper, we introduce a gaussian enveloped linear chirp signal that can change parameters for consideration of target material characteristics. Using the gaussian enveloped linear chirp signal, time-frequency domain reflectomety is able to detect fault location in power transmission line. we suggest design method of reference signal for power transmission line fault detection. This method is verified by locating fault in HIV low voltage power transmission line.

  • PDF

Reference Symbol Arrangement in LTE OFDM Systems (LTE OFDM 시스템에서의 기준 심볼 배치)

  • Choi, Seung-Kuk
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.19 no.12
    • /
    • pp.2805-2812
    • /
    • 2015
  • For the purpose of estimation of time variant frequency selective transmission channels, reference symbols are usually employed. The bit error performance of LTE OFDM systems is analyzed in the case of LTE standard reference symbol arrangement. Results show that LTE OFDM system with this LTE reference symbol arrangement is robust against Doppler time variant fading. However, the performance of that system is degraded due to channel estimation error in frequency domain. An equidistant arrangement with a diamond shape structure of reference symbols, however having 4 subcarriers distance in frequency domain, is suggested for the optimal channel estimation.

A DC Reference Fluctuation Reduction Circuit for High-Speed CMOS A/D Converter (고속 CMOS A/D 변환기를 위한 기준전압 흔들림 감쇄 회로)

  • Park Sang-Kyu;Hwang Sang-Hoon;Song Min-Kyu
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.43 no.6 s.348
    • /
    • pp.53-61
    • /
    • 2006
  • In high speed flash type or pipelining type A/D Converter, the faster sampling frequency is, the more the effect of DC reference fluctuation is increased by clock feed-through and kick-back. When we measure A/D Converter, further, external noise increases reference voltage fluctuation. Thus reference fluctuation reduction circuit must be needed in high speed A/D converter. Conventional circuit simply uses capacitor but layout area is large and it's not efficient. In this paper, a reference fluctuation reduction circuit using transmission gate is proposed. In order to verify the proposed technique, we designed and manufactured 6bit 2GSPS CMOS A/D converter. The A/D converter is based on 0.18um 1-poly 5-metal N-well CMOS technology, and it consumes 145mW at 1.8V power supply. It occupies chip area of $977um\times1040um$. Experimental result shows that SNDR is 36.25 dB and INL/DNL ${\pm}0.5LSB$ when sampling frequency is 2GHz.

Research on vibration control of a transmission tower-line system using SMA-BTMD subjected to wind load

  • Tian, Li;Luo, Jingyu;Zhou, Mengyao;Bi, Wenzhe;Liu, Yuping
    • Structural Engineering and Mechanics
    • /
    • v.82 no.5
    • /
    • pp.571-585
    • /
    • 2022
  • As a vital component of power grids, long-span transmission tower-line systems are vulnerable to wind load excitation due to their high flexibility and low structural damping. Therefore, it is essential to reduce wind-induced responses of tower-line coupling systems to ensure their safe and reliable operation. To this end, a shape memory alloy-bidirectional tuned mass damper (SMA-BTMD) is proposed in this study to reduce wind-induced vibrations of long-span transmission tower-line systems. A 1220 m Songhua River long-span transmission system is selected as the primary structure and modeled using ANSYS software. The vibration suppression performance of an optimized SMA-BTMD attached to the transmission tower is evaluated and compared with the effects of a conventional bidirectional tuned mass damper. Furthermore, the impacts of frequency ratios and SMA composition on the vibration reduction performance of the SMA-BTMD are evaluated. The results show that the SMA-BTMD provides superior vibration control of the long-span transmission tower-line system. In addition, changes in frequency ratios and SMA composition have a substantial impact on the vibration suppression effects of the SMA-BTMD. This research can provide a reference for the practical engineering application of the SMA-BTMD developed in this study.

A Coarse Frequency Offset Estimation Based on the Differential Correlation in DAB Systems

  • Kim, Han-Jong;Paik, Jong-Ho;Park, Cheol-Hee;You, Young-Hwan;Ju, Min-Chul;Jin-Woong
    • Journal of electromagnetic engineering and science
    • /
    • v.1 no.1
    • /
    • pp.105-111
    • /
    • 2001
  • This paper presents a new and robust technique for a coarse frequency offset estimation in OFDM systems. As an evaluation of the proposed algorithm, we apply it to Eureka 147 DAB system. The proposed coarse frequency offset estimation algorithm is based on the differential detection technique between adjacent subcarriers to eliminate the phase shift effects of symbol timing offset and fractional frequency offset. A coarse frequency offset is determined from the correlation output between a received interarrier differential phase reference symbol and several locally generated but frequency-shifted intercarrier differential phase reference symbols. The performance of our estimation algorithm is evaluated by means of computer simulation and is compared with those of previous proposed algorithms for DAB transmission modes I, II, III, and IV. Simulation results show that the proposed algorithm generates extremely accurate estimates with low complexity irrespective of the symbol timing offset.

  • PDF

Permittivity Characteristic Analysis of Planar Substrates Using H-shaped Resonant Aperture (H-모양 공진 개구를 이용한 평면 기판의 유전율 특성 분석)

  • Yeo, Junho;Lee, Jong-Ig
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2018.05a
    • /
    • pp.55-56
    • /
    • 2018
  • In this paper, a method for analyzing the dielectric constant of a planar substrate is proposed. To this end, a band-stop filter was created by adding a H-shaped resonant aperture to the ground plane of a microstrip transmission line. A planar substrate of 2 mm thickness was placed behind the ground plane of the microstrip transmission line and the change of the resonant frequency with the change of the dielectric constant of the substrate was investigated. It can be seen that the change ratio of the frequency to the reference resonant frequency is larger than that of the conventional complementary split ring resonator structure.

  • PDF

Measurement of Acoustic Properties of Polyurethane by the through Transmission Method (투과법을 이용한 폴리우레탄재료의 음향특성 측정)

  • 김태식;이기석;안봉영;이진형
    • The Journal of the Acoustical Society of Korea
    • /
    • v.19 no.1
    • /
    • pp.40-47
    • /
    • 2000
  • To obtain the acoustic properties of dispersive polyurethane with high attenuation, through transmission method was applied by ultrasonic. In through transmission method, the sound velocity and attenuation coefficient of specimen were obtained by using Sachse's method which can be applied to small size specimen. But there is a problem when the reference signal is selected, so the result is not precise. The more precise acoustic properties of polyurethane was obtained when two specimens with different thickness were used. To predict the acoustic properties of low frequency range, the acoustic properties extended to the low frequency range were calculated by Kramers - Kronig relation. As a result, we studied on the relation between the sound velocity and the attenuation coefficient with frequency.

  • PDF