• Title/Summary/Keyword: reference equipment

Search Result 440, Processing Time 0.027 seconds

Development of an equipment preventing overheated in a car using the solar cell

  • Han, Jong-Soo;Seo, Chang-Jun
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.938-941
    • /
    • 2003
  • In this paper we develop an equipment which prevents vehicles from overheating their inside due to exposure to direct sunlight in summer. Overheating of inside vehicle may give rise to accidents, for instances, dying from suffocation, the deformation of its internal equipment and the explosion from the cracks of its internal parts etc.. The equipment is operated under no starting engine. We adjust the overheating of the inside vehicle by operating the equipment. This equipment checks the temperature of the inside vehicle using temperature sensor. If the temperature increases more than reference temperature(a condition which can be given by the driver), the equipment will operate until the temperature of the inside decreases to the given temperature. Its power is obtained from solar cell. So the equipment keeps away overheating accidents as well as provides the drivers with optimized condition. And also it increases the ability of original car battery through solar cell.

  • PDF

New Control Strategy for Three-Phase Grid-Connected LCL Inverters without a Phase-Locked Loop

  • Zhou, Lin;Yang, Ming;Liu, Qiang;Guo, Ke
    • Journal of Power Electronics
    • /
    • v.13 no.3
    • /
    • pp.487-496
    • /
    • 2013
  • The three-phase synchronous reference frame phase-locked loop (SRF-PLL) is widely used for synchronization applications in power systems. In this paper, a new control strategy for three-phase grid-connected LCL inverters without a PLL is presented. According to the new strategy, a current reference can be generated by using the instantaneous power control scheme and the proposed positive-sequence voltage detector. Through theoretical analysis, it is indicated that a high-quality grid current can be produced by introducing the new control strategy. In addition, a kind of independent control for reactive power can be achieved under unbalanced and distorted grid conditions. Finally, the excellent performance of the proposed control strategy is validated by means of simulation and experimental results.

A Study on the Establishment of Reference Linking System for National R&D Information (국가 R&D정보 참조연계서비스 시스템 구축에 관한 연구)

  • Kwon, Lee-Nam;Kim, Jae-Soo
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2007.11a
    • /
    • pp.172-177
    • /
    • 2007
  • Reference linking based on a identification system is being widely used both domestically and overseas. National R&D information contains all information related to the R&D programs such as the output and equipment information resulting from the participant and project information. The reference linking service enables the user to freely look up output of a certain program, participant of a project, equipment information from the project or participant and all other information that originates from a R&D project without having to search for it. The reference linking service in the area of national R&D will enable the linking of heterogeneous information produced at different sources.

  • PDF

The Study on Items derived of Machine Equipment Construction Standards for Project Cost Savings (사업비 절감을 위한 기계설비 건설기준 개선 항목 도출에 관한 연구)

  • Kim, Kyong-Hoon;Kim, Tae-Song
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2014.05a
    • /
    • pp.60-61
    • /
    • 2014
  • the reference values are high, because the Korean construction standards quote the foreign construction standars indiscriminately. Therefore ten experts were consulted to draw the items about the machine equipment construction standards for project cost saving in this study.

  • PDF

Deterioration Characteristics and an On-Line Diagnostic Equipment for Surge Protective Devices (서지 보호기의 열화 특성과 온라인 진단장치)

  • Park, Kyoung-Soo;Wang, Guoming;Hwang, Seong-Cheol;Kim, Sun-Jae;Kil, Gyung-Suk
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.29 no.10
    • /
    • pp.635-640
    • /
    • 2016
  • This paper dealt with the deterioration characteristics and an on-line diagnosis equipment for SPDs (surge protective devices). An accelerated aging test was carried out using a $8/20{\mu}s$ standard lightning impulse current to analyze the changes of electrical characteristics and to propose the diagnostic parameters and the criterion for deterioration of ZnO varistor which is the core component of SPDs. Based on the experimental results, an on-line diagnosis equipment for SPD was fabricated, which can measure the total leakage current, reference and clamping voltage. The leakage current measurement circuit was designed using a low-noise amplifier and a clamp type ZCT. A linear controller, the leakage current measurement part and a HVDC were used in the measurement of reference voltage. The measurement circuit of clamping voltage consisted of a surge generator and a coupling circuit. In a calibration process, measurement error of the prototype equipment was less than 3%.

Calculation of the Harmonic Emission Limit for low-Voltage Electrical Equipment (국내 저압 전기기기의 고조파 유출 제한값 산정)

  • Kang, Moon-Ho;Song, Yang-Hoi;Lee, Heung-Ho
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.10
    • /
    • pp.56-61
    • /
    • 2008
  • Because the harmonic disturbance characteristic which makes voltage drop and the deterioration of instantaneous power quality in electrical power system overheats the NGR and the customer capacitor and malfunctions the OCGR and AMR, it is necessary for electric power company to take active measures to reduce this disturbance. International Electrotechnical Commission(IEC) 61000-3-2 specifies limits for harmonic current emissions generated by low voltage(LV) electrical equipment whose input current $\leq$ 16(A) per phase. Analysis shows that limits for Class A equipment in IEC are calculated using the reference impedance of LV system and maximum permissible voltage and limits for other Classes are also calculated based on limits for Class A. Therefore we have calculated four(4) internal limits for LV electrical equipment using the korea reference impedance and maximum permissible voltage in this paper.

Development of e-Catalog System for Overseas Construction Equipments (해외건설 기자재 전자카탈로그 시스템 구축)

  • Ahn, Ho-Jun;Park, Ho-Byung;Jang, Kwang-Sub;Youk, Jong-Gon;Lee, Jae-Chon
    • Korean Journal of Computational Design and Engineering
    • /
    • v.13 no.2
    • /
    • pp.98-108
    • /
    • 2008
  • Plant, civil engineering and construction equipment data of overseas construction are obtained and then analyzed, classified and integrated by experts. With those refined data set, we built classification system and defined property information with reference to international standard (ISO 15926, IRDL). If class in ISO 15926 is predefined for equipment of interest, we used the class as is. If not, we created and defined new classes on the basis of ISO 15926 classes. If there is similar class for equipment of interest, extension or inheritance methods were used. As a result, classification system of five levels and 637 classes were built and construction equipment information were expressed in open structure of XML such as tree structure of classification system and detailed information with number equipments for each specific equipment. We also developed the electronic catalog system which is basically equipment information management system providing various product search functions.

Analysis for the Dynamic Characteristics of the Moving Equipment for the large Radar Transportation (대형 레이더 수송용 이동치구의 주행동특성 분석)

  • Jeon, Jong-Ik;Lee, Jong-Hak;Kang, Young-Sik;Choi, Ji-Ho;Kang, Dong-Seok
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2013.10a
    • /
    • pp.416-421
    • /
    • 2013
  • In this paper, the design concept of the transport of defense equipment and processes were established. And the transport of large radar equipment design were investigated. Detailed design of moving equipment with reference to the U.S. military standard was performed.Damping system of the moving equipment by using a simulation designed to predict In order to minimize shock and vibration in the vehicle due to the irregular road surface is transmitted through. Analysis of the damping system was verified using the driving test.

  • PDF

A Novel Fast Open-loop Phase Locking Scheme Based on Synchronous Reference Frame for Three-phase Non-ideal Power Grids

  • Xiong, Liansong;Zhuo, Fang;Wang, Feng;Liu, Xiaokang;Zhu, Minghua;Yi, Hao
    • Journal of Power Electronics
    • /
    • v.16 no.4
    • /
    • pp.1513-1525
    • /
    • 2016
  • Rapid and accurate phase synchronization is critical for the reliable control of grid-tied inverters. However, the commonly used software phase-locked loop methods do not always satisfy the need for high-speed and accurate phase synchronization under severe grid imbalance conditions. To address this problem, this study develops a novel open-loop phase locking scheme based on a synchronous reference frame. The proposed scheme is characterized by remarkable response speed, high accuracy, and easy implementation. It comprises three functional cascaded blocks: fast orthogonal signal generation block, fast fundamental-frequency positive sequence component construction block, and fast phase calculation block. The developed virtual orthogonal signal generation method in the first block, which is characterized by noise immunity and high accuracy, can effectively avoid approximation errors and noise amplification in a wide range of sampling frequencies. In the second block, which is the foundation for achieving fast phase synchronization within 3 ms, the fundamental-frequency positive sequence components of unsymmetrical grid voltages can be achieved with the developed orthogonal signal construction strategy and the symmetrical component method. The real-time grid phase can be consequently obtained in the third block, which is free from self-tuning closed-loop control and thus improves the dynamic performance of the proposed scheme. The proposed scheme is adaptive to severe unsymmetrical grid voltages with sudden changes in magnitude, phase, and/or frequency. Moreover, this scheme is able to eliminate phase errors induced by harmonics and random noise. The validity and utility of the proposed scheme are verified by the experimental results.