• Title/Summary/Keyword: reference energy

Search Result 1,629, Processing Time 0.029 seconds

A Study on Effect Analysis of Integrated Demand Management According to Energy System Management Model (Energy System Management 모형을 통한 통합 수요관리 효과분석에 관한 연구)

  • Kim, Yong-Ha;Jo, Hyeon-Mi;Kim, Young-Gil;Park, Hwa-Yong;Kim, Hyeong-Jung;Woo, Sung-Min
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.7
    • /
    • pp.1339-1346
    • /
    • 2011
  • This paper is developed to demand management scenario of energy consumption efficiency improvement, electricity generation efficiency improvement, network efficiency improvement, change of distribution ratio, movement of energy source, change of heating system, put of CHP to quantitatively assess to impact on energy use of demand management at the national level. This scenario can be applied Energy System Management model was developed based on Energy Balance Flow. In addition, effect analysis through built demand management scenario was quantitatively evaluated integrated demand management effectiveness of energy cost saving, CO2 emission reduction and energy savings of national level by calculating to primary energy source usage change in terms of integration demand management effect more often than not a single energy source separated electricity, heat and gas.

Performance Evaluation of Electrochromic Window System by Different Orientations and Locations in Korea (Electrochromic 창호 적용시 지역별 건물 냉난방 에너지 소비량 절감성능)

  • Shin, Jae-Yoon;Chae, Young Tae
    • Journal of the Korean Solar Energy Society
    • /
    • v.38 no.5
    • /
    • pp.75-84
    • /
    • 2018
  • The most crucial point of reducing building energy is application of high performance envelope. The amount of heat exchange through window is highest in comparison of other envelopes so that heat exchange through window influence directly with building energy consumption. The window energy performance can be define with thermal, leakage and optical performance. In previous study we can confirmed that not only thermal performance but also optical performance are considered, 11% to 15% of building energy consumption can be reduced. Smart window system has potential of energy saving so that many industry field use smart window system including architectural area and these aspect causes smart window market continuous growth year by year. In this study, building energy consumption has been analyzed which consist of smart window that dynamically control optical states. The consideration of standard commercial building model for research, the reference medium size commercial building model of DOE (Department Of Energy, USA) has been used. The building energy simulation result of 4 axis in 8 regions in Korea shows 8% to 22% reduction of building energy consumption by application of smart window system.

Detection of Colloidal Nanoparticles in KURT Groundwater by a Mobile Laser-Induced Breakdown Detection System (이동식 레이저 유도 파열 검출 장치를 이용한 KURT 지하수 내 콜로이드 나노 입자 검출)

  • Jung, Euo-Chang;Cho, Hye-Ryun;Park, Mi-Ri;Baik, Min-Hoon
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.9 no.1
    • /
    • pp.41-48
    • /
    • 2011
  • A mobile laser-induced breakdown detection (LIBD) system was developed for the field measurement of the size and concentration of aquatic colloidal nanoparticles sampled from Korea Atomic Energy Research Institute Underground Research Tunnel (KURT). The established LIBD apparatus is based on the optical detection of a laser-induced plasma by means of a two-dimensional optical imaging method for determining the size of nanoparticle. Calibration curve for determining the size of nanoparticle was obtained from the polystyrene reference particles of a well-defined size. The first direct application was made at KURT for investigating the particle sizes in groundwater. By comparing the size of particles in groundwater with the sizes of reference particles, the mean particle size of approximately $108{\pm}26$ nm with the concentration lower than 50 ppb was determined.

Intercomparison and Determination of Trace Elements in Urban Dust by Neutron Activation Analysis (중성자방사화분석법을 이용한 대기분진중의 미량원소 비교분석)

  • Chung, Yong-Sam;Moon, Jong-Hwa;Kim, Sun-Ha;Park, Kwang-Won;Kang, Sang-Hun
    • Analytical Science and Technology
    • /
    • v.13 no.2
    • /
    • pp.179-188
    • /
    • 2000
  • Trace elements in air samples artificially loaded on filters with urban dust and the bulk material of urban dust as an environmental sample were determined non-destructively using instrumental neutron activation analysis. Standard reference material (Urban Dust, SRM 1648) of the National Institute of Standard and Technology was used for the analytical quality control. The relative error for 37 elements was less than 15% and the standard deviation was less than 10%. 29 elements in the urban dust and 21 elements in the loaded filter sample were determined respectively. To evaluate the proficiency and reliability of the measurement, data intercomparison was performed and 39 analytical laboratories participated in the analysis using different analytical methods; neutron activation analysis, particle induced X-ray emission analysis, X-ray fluorescence analysis and atomic absorption spectrometry. Z-scores were calculated using the standard deviation of the laboratorie's mean as target standard deviation, and a good result was obtained that the values fall between -1 and +1 except some elements.

  • PDF

Development of a Computation Program for Automatic Processing of Calibration Data of Radiation Instrument (방사선 측정기 교정 데이터의 자동처리를 위한 전산프로그램 개발)

  • Jang, Ji-Woon;Shin, Hee-Sung;Youn, Cheung;Lee, Yun-Hee;Kim, Ho-Dong;Jung, Ki-Jung
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.26 no.4
    • /
    • pp.246-254
    • /
    • 2006
  • A computation program has been developed for automatic data processing in the calibration process of gamma survey meter. The automatic processing program has been developed based on Visual Basic. The program has been coded according to steps of calibration procedure. The OLE(object linking an embedding) Excel automation method fur automatic data processing is used in this program, which is a kind of programming technique for the Excel control. The performance test on the basis of reference data has been carried out by using the developed program. In the results of performance test, the values of calibration factors and uncertainties by the developed program were equal to those obtained from the reference data. In addition, It was revealed that the efficiency and precision of working are significantly increased by using the developed program.

Development of Initial Design Stage Guidelines for nearly Zero Energy Offices : A Central-Climate Zone of Korea Case Study

  • Kang, Hae Jin;Yi, Won
    • KIEAE Journal
    • /
    • v.15 no.5
    • /
    • pp.67-74
    • /
    • 2015
  • This study aimed to develop a design manual to be used during the initial stage of the nearly Zero Energy Building (nZEB) design process. Recently, with the increased demand for nZEBs, there are many architects and architectural firms who are becoming interested in nZEB design. However, since the nZEB design process requires a different approach to the conventional building design process, architects have difficulties with application of the nZEB design process in their projects. Therefore, a design manual which can be used in the nZEB design process was developed in this study. Based on an intensive literature review, energy-saving strategies and their performance levels, which affect heating and cooling energy consumptions were established for a reference building. To analyze the sensitivity of each energy strategy to the overall performance, computer simulations using EnergyPlus were performed. At the same time, an Analysis of Variance assessment was conducted to estimate the relative importance of each energy factor. The energy sensitivity and priority of the energy factors was developed into a set of design guidelines.

Comparative Assessment of Typical Year Dataset based on POA Irradiance (태양광 패널 일사량에 기반한 대표연도 데이터 비교 평가)

  • Changyeol Yun;Boyoung Kim;Changki Kim;Hyungoo Kim;Yongheack Kang;Yongil Kim
    • New & Renewable Energy
    • /
    • v.20 no.1
    • /
    • pp.102-109
    • /
    • 2024
  • The Typical Meteorological Year (TMY) dataset compiles 12 months of data that best represent long-term climate patterns, focusing on global horizontal irradiance and other weather-related variables. However, the irradiance measured on the plane of the array (POA) shows certain distinct distribution characteristics compared with the irradiance in the TMY dataset, and this may introduce some biases. Our research recalculated POA irradiance using both the Isotropic and DIRINT models, generating an updated dataset that was tailored to POA characteristics. Our analysis showed a 28% change in the selection of typical meteorological months, an 8% increase in average irradiance, and a 40% reduction in the range of irradiance values, thus indicating a significant shift in irradiance distribution patterns. This research aims to inform stakeholders about accurate use of TMY datasets in potential decision-making. These findings underscore the necessity of creating a typical dataset by using the time series of POA irradiance, which represents the orientation in which PV panels will be deployed.

Thermopile Radiometer Calibration Using Reference Instrument (표준준기에 의한 일사계 교정)

  • Jo, Dok-Ki;Yun, Chang-Yeol;Kim, Kwang-Deuk;Kang, Young-Heak
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.199.2-199.2
    • /
    • 2010
  • The main purpose of the calibration procedure is to perform a one to one comparison of the reference pyranometer and the test pyranometer. In order to achieve this, both pyranometers need to be exposed to exactly the same irradiance, under the same circumstances. There are a number of error sources that could result in a wrong measurement. Most importantly Lamp instability, pyranometer offsets, thermal offsets of junctions, voltmeter offset, voltmeter instability, reference pyranometer instability, tilting of the pyranometers and differences in sensor height. Another sun-disc calibration procedure compares the computed vertical component of the direct irradiance as measured by a pyranometer with that measured by the pyranometer to be calibrated. Readings are taken with the levelled pyranometer on a clear day. Firstly the global irradiance and then the diffuse component are measured. Simultaneously measurement of direct irradiance is made with the pyrheliometer. The ways of performing the calibration and the subsequent calculation have been chosen such that the effect all these error sources has been eliminated as much as possible.

  • PDF

Double Vector Based Model Predictive Torque Control for SPMSM Drives with Improved Steady-State Performance

  • Zhang, Xiaoguang;He, Yikang;Hou, Benshuai
    • Journal of Power Electronics
    • /
    • v.18 no.5
    • /
    • pp.1398-1408
    • /
    • 2018
  • In order to further improve the steady-state control performance of model predictive torque control (MPTC), a double-vector-based model predictive torque control without a weighting factor is proposed in this paper. The extended voltage vectors synthesized by two basic voltage vectors are used to increase the number of feasible voltage vectors. Therefore, the control precision of the torque and the stator flux along with the steady-state performance can be improved. To avoid testing all of the feasible voltage vectors, the solution of deadbeat torque control is calculated to predict the reference voltage vector. Thus, the candidate voltage vectors, which need to be evaluated by a cost function, can be reduced based on the sector position of the predicted reference voltage vector. Furthermore, a cost function, which only includes a reference voltage tracking error, is designed to eliminate the weighting factor. Moreover, two voltage vectors are applied during one control period, and their durations are calculated based on the principle of reference voltage tracking error minimization. Finally, the proposed method is tested by simulations and experiments.

A Preliminary Study for a Glass Geological Reference Material Using Obsidian (흑요암을 이용한 유리 지질 표준물질에 대한 예비 연구)

  • Jin, Mi-Eun;Jwa, Yong-Joo;Park, Sang Gu;Sun, Gwang Min
    • Korean Journal of Mineralogy and Petrology
    • /
    • v.33 no.1
    • /
    • pp.65-71
    • /
    • 2020
  • Glass reference materials have been essentially used for precise geochemistry analytical techniques. In order to make up for the drawback of synthetic glass reference materials, which have the high uncertainty caused by the difference in composition of natural rocks, we introduce a glass geostandard using natural glass. The NK-B1G sample, which comes from the Baekdusan obsidian, is a natural glassy rock that contains only few crystals such as microlites or inclusions. We examined the feasibility of the sample as a reference material for microanalysis like EPMA or LA-ICPMS.