• Title/Summary/Keyword: reference coordinates

Search Result 241, Processing Time 0.028 seconds

Estimation of Sejong VLBI IVP Point Using Coordinates of Reflective Targets with Their Measurement Errors (반사타겟 좌표 및 오차정보를 이용한 세종 VLBI IVP 위치계산)

  • Hong, Chang-Ki;Bae, Tae-Suk;Yi, Sangoh
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.38 no.6
    • /
    • pp.717-723
    • /
    • 2020
  • Determination of local tie vectors between the space geodetic techniques such as VLBI (Very Long Baseline Interferometer), SLR (Satellite Laser Ranging), DORIS (Doppler Orbit determination and Radiopositioning Integrated on Satellite), GNSS (Global Navigation Satellite System) is essential for combination of ITRF (International Terrestrial Reference Frame). Therefore, it is required to compute IVP (Invariant Point) position of each space geodetic technique with high accuracy. In this study, we have computed Sejong VLBI IVP position by using updated mathematical model for adjustment computation so that the improvement on efficiency and reliability in computation are obtained. The measurements used for this study are the coordinates of reflective targets on the VLBI antenna and their accuracies are set to 1.5 mm for each component. The results show that the position of VLBI IVP together with its standard deviation is successfully estimated when they are compared with those of the results from previous study. However, it is notable that additional terrestrial surveying should be performed so that realistic measurement errors are incorporated in the adjustment computation process.

A Plan for Applying Cadastral Record to the Transformation of Cadastral Coordinates into the World Geodetic System (지적좌표 세계측지계 변환성과의 지적공부 적용 및 활용 방안)

  • Hong, Sung-Eon
    • Journal of Digital Convergence
    • /
    • v.19 no.2
    • /
    • pp.195-202
    • /
    • 2021
  • In this study, from a long-term perspective, we tried to find and present a plan to apply the results of transformation of cadastral coordinates to the world geodetic system in stages for cadastral records of graphical and digital cadastral area. There was a case where the difference in area before and after the transformation occurred irregularly in the transformation result of the cadastral coordinate system currently being promoted. In addition, it was found that transformation errors in cadastral non-coincidence areas occurred accumulatively, and the period for acquiring world geodetic results for cadastral reference points was insufficient. In order to solve this problem, the study proposed a plan to provide spatial information and related fields through advancement of continuous cadastral maps, etc. for maps that have been primarily transformed by the end of 2020. In addition, the maps used for cadastral surveying purposes were presented in the direction of applying them to cadastral records in numerical form in the long term to conform to the characteristics of graphical and digital cadastral area. It is expected that more stable cadastral record will be reflected by applying the world coordinate transformation performance by dividing the graphical and digital cadastral area.

Studying the Ephemeris Effect on Position Accuracy Based on Criteria Applied to Baseline Lengths by New MATLAB Program (NMP)

  • Shimaa Farouk;Mahmoud El-Nokrashy;Ahmed Abd-Elhay;Nasr Saba
    • Journal of Astronomy and Space Sciences
    • /
    • v.40 no.3
    • /
    • pp.113-122
    • /
    • 2023
  • Although the Relative Global Navigation Satellite System (GNSS) positioning technique provides high accuracy, it has several drawbacks. The scarcity of control points, the long baselines, and using of ultra-rabid and rabid products increased position errors. This study has designed a New MATLAB Program that helps users automatically select suitable IGS stations related to the baseline lengths and the azimuth between GNSS points and IGS stations. This study presented criteria for the length of the baselines used in Egypt and an advanced estimated accuracy before starting the project. The experimental test studies the performance of the position accuracy related to the relation between three factors: observation session, final, rabid, and ultrarabid products, and the baseline lengths. Ground control point mediates Egypt was selected as a test point. Nine surrounding IGS stations were selected as reference stations, and the coordinates of the tested point were calculated based on them. Baselines between the tested point and the IGS stations were classified regarding proposal criteria. The coordinates of the tested point were obtained in different observation sessions (0.5, 1, 2, 4, 5, 6, 7, 7.5 h). The results indicated that the lengths of the baseline in Egypt were classified short (less than 600 km), medium (600-1,200 km), and long (greater than 1,200 km) and required a minimum observation time of 4, 5, and 7 h to obtain accuracy 10, 19, 48 mm sequentially. The position accuracy was superior for the rapid and the final than the ultra-rapid products by 16%. A short baseline was at the best case; there was a performance in position accuracy with a 57% deduction in observation time compared with the long baseline.

Improvement of GPS Relative Positioning Accuracy by Using Crustal Deformation Model in the Korean Peninsula (GPS상대측위 정확도 향상을 위한 한반도 지각변동모델 개발)

  • Cho, Jae-Myoung;Yun, Hong-Sik;Lee, Mi-Ran
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.29 no.3
    • /
    • pp.237-247
    • /
    • 2011
  • As of 2011, 72 Permanent GPS Stations are installed to control DGPS reference points by the National Geographic Information Institute in South Korea. As the center of the Earth's mass continues to move, the coordinates of the permanent GPS stations become inconsistent over time. Thus, a reference frame using a set of coordinates and their velocities of a global network of stations at a specific period has been used to solve the inconsistency. However, the relative movement of the permanent GPS stations can lower the accuracy of GPS relative positioning. In this research, we first analyzed the data collected daily during the past 30 months at the 40 permanent GPS stations within South Korea and the 5 IGS permanent GPS stations around the Korean Peninsula using a global network adjustment. We then calculated the absolute and relative amount of movement of the GPS permanent stations. We also identified the optimum renewal period of the permanent GPS stations considering the accuracy of relative GPS surveying. Finally, we developed a Korean a Korean crustal movement model that can be used to improvement of accuracy.

Impact of Tropospheric Delays on the GPS Positioning with Double-difference Observables (대류권 지연이 이중차분법을 이용한 GPS 측위에 미치는 영향)

  • Hong, Chang-Ki
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.31 no.5
    • /
    • pp.421-427
    • /
    • 2013
  • In general, it can be assumed that the tropospheric effect are removed through double-differencing technique in short-baseline GPS data processing. This means that the high-accuracy positioning can be obtained because various error sources can be eliminated and the number of unknown can be decreased in the adjustment computation procedure. As a consequence, short-baseline data processing is widely used in the fields such as deformation monitoring which require precise positioning. However, short-baseline data processing is limited to achieve high positioning accuracy when the height difference between the reference and the rover station is significant. In this study, the effects of tropospheric delays on the determination of short-baseline is analyzed, which depends on the orientation of baseline. The GPS measurements which include tropospheric effect and measurement noises are generated by simulation, and then rover coordinates are computed by short-baseline data processing technique. The residuals of rover coordinates are analyzed to interpret the tropospheric effect on the positioning. The results show that the magnitudes of the biases in the coordinate residuals increase as the baseline length gets longer. The increasing rate is computed as 0.07cm per meter in baseline length. Therefore, the tropospheric effects should be carefully considered in short-baseline data processing when the significant height difference between the reference and rover is observed.

TLS (Total Least-Squares) within Gauss-Helmert Model: 3D Planar Fitting and Helmert Transformation of Geodetic Reference Frames (가우스-헬머트 모델 전최소제곱: 평면방정식과 측지좌표계 변환)

  • Bae, Tae-Suk;Hong, Chang-Ki;Lim, Soo-Hyeon
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.40 no.4
    • /
    • pp.315-324
    • /
    • 2022
  • The conventional LESS (LEast-Squares Solution) is calculated under the assumption that there is no errors in independent variables. However, the coordinates of a point, either from traditional ground surveying such as slant distances, horizontal and/or vertical angles, or GNSS (Global Navigation Satellite System) positioning, cannot be determined independently (and the components are correlated each other). Therefore, the TLS (Total Least Squares) adjustment should be applied for all applications related to the coordinates. Many approaches were suggested in order to solve this problem, resulting in equivalent solutions except some restrictions. In this study, we calculated the normal vector of the 3D plane determined by the trace of the VLBI targets based on TLS within GHM (Gauss-Helmert Model). Another numerical test was conducted for the estimation of the Helmert transformation parameters. Since the errors in the horizontal components are very small compared to the radius of the circle, the final estimates are almost identical. However, the estimated variance components are significantly reduced as well as show a different characteristic depending on the target location. The Helmert transformation parameters are estimated more precisely compared to the conventional LESS case. Furthermore, the residuals can be predicted on both reference frames with much smaller magnitude (in absolute sense).

Area Changes in the Administrative Boundary Map of Korea by National Geodetic Reference Frames (세계측지계 전환에 따른 우리나라 행정구역도상 면적 변화)

  • Bae, Tae-Suk;Kim, Jeong-Hee;Yoon, Jong-Seong;Jeong, Jae-Joon
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.30 no.3
    • /
    • pp.241-247
    • /
    • 2012
  • The national geodetic reference frame of Korea switched to the International Terrestrial Reference Frame (ITRF) in 2003. In order to study the land area changes, we calculated the entire land area of Korea using the administrative boundaries of census data provided by Statistics Korea. The standard transformation procedure by the National Geographic Information Institute (NGII) was followed. The Transverse Mercator (TM) projected coordinates were transformed into the GRS80-based world geodetic reference frame, and the ellipsoidal and the projected areas were calculated. The provinces that range over two projection origins were divided into two polygons and projected using appropriate origins. After the transformation, all boundaries were shifted in the northwestern direction, resulting in a decreased area of $1.36km^2$ (about 0.0013%) on the projected plane. Moving the boundaries into a high latitude area cancels out the effect of the enlarged ellipsoid. In addition, the rate of change shows that a higher-latitude province is more sensitive to the shift of the boundaries. The data by Statistics Korea is significantly different from those of the Ministry of Land, Transport and Maritime Affairs (MLTM), thus it is urgently recommended that the data are integrated and unified.

Development of Distortion Correction Technique in Tilted Image for River Surface Velocity Measurement (하천 표면영상유속 측정을 위한 경사영상 왜곡 보정 기술 개발)

  • Kim, Hee Joung;Lee, Jun Hyeong;Yoon, Byung Man;Kim, Seo Jun
    • Ecology and Resilient Infrastructure
    • /
    • v.8 no.2
    • /
    • pp.88-96
    • /
    • 2021
  • In surface image velocimetry, a wide area of a river is photographed at an angle to measure its velocity, inevitably causing image distortion. Although a distorted image can be corrected into an orthogonal image by using 2D projective coordinate transformation and considering reference points on the same plane as the water surface, this method is limited by the uncertainty of changes in the water level in the event of a flood. Therefore, in this study, we developed a tilt image correction technique that corrects distortions in oblique images without resetting the reference points while coping with changes in the water level using the geometric relationship between the coordinates of the reference points set at a high position the camera, and the vertical distance between the water surface and the camera. Furthermore, we developed a distortion correction method to verify the corrected image, wherein we conducted a full-scale river experiment to verify the reference point transformation equation and measure the surface velocity. Based on the verification results, the proposed tilt image correction method was found to be over 97% accurate, whereas the experiment result of the surface velocity differed by approximately 4% as compared to the results calculated using the proposed method, thereby indicating high accuracy. Application of the proposed method to an image-based fixed automatic discharge measurement system can improve the accuracy of discharge measurement in the event of a flood when the water level changes rapidly.

Utilization of Ground Control Points using LiDAR Intensity and DSM (LiDAR 반사강도와 DSM을 이용한 지상기준점 활용방안)

  • Lim, Sae-Bom;Kim, Jong-Mun;Shin, Sang-Cheol;Kwon, Chan-O
    • Spatial Information Research
    • /
    • v.18 no.5
    • /
    • pp.37-45
    • /
    • 2010
  • AT(Aerial Triangulation) is the essential procedure for creating orthophoto and transforming coordinates on the photographs into the real world coordinates utilizing GCPs (Ground Control Point) which is obtained by field survey and the external orientation factors from GPS/INS as a reference coordinates. In this procedure, all of the GCPs can be collected from field survey using GPS and Total Station, or obtained from digital maps. Collecting GCPs by field survey is accurate than GCPs from digital maps; however, lots of manpower should be put into the collecting procedure, and time and cost as well. On the other hand, in the case of obtaining GCPs from digital maps, it is very difficult to secure the required accuracy because almost things at each stage in the collecting procedure should rely on the subjective judgement of the performer. In this study, the results from three methods have been compared for the accuracy assessment in order to know if the results of each case is within the allowance error: for the perceivable objects such as road boarder, speed bumps, constructions etc., 1) GCPs selection utilizing the unique LiDAR intensity value reflected from such objects, 2) using LiDAR DSM and 3) GCPs from field survey. And also, AT and error analysis have been carried out w ith GCPs obtained by each case.

Analysis of 3D Accuracy According to Determination of Calibration Initial Value in Close-Range Digital Photogrammetry Using VLBI Antenna and Mobile Phone Camera (VLBI 안테나와 모바일폰 카메라를 활용한 근접수치사진측량의 캘리브레이션 초기값 결정에 따른 3차원 정확도 분석)

  • Kim, Hyuk Gi;Yun, Hong Sik;Cho, Jae Myoung
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.33 no.1
    • /
    • pp.31-43
    • /
    • 2015
  • This study had been aimed to conduct the camera calibration on VLBI antenna in the Space Geodetic Observation Center of Sejong City with a low-cost digital camera, which embedded in a mobile phone to determine the three-dimension position coordinates of the VLBI antenna, based on stereo images. The initial values for the camera calibration have been obtained by utilizing the Direct Linear Transformation algorithm and the commercial digital photogrammetry system, PhotoModeler $Scanner^{(R)}$ ver. 6.0, respectively. The accuracy of camera calibration results was compared with that the camera calibration results, acquired by a bundle adjustment with nonlinear collinearity condition equation. Although two methods showed significant differences in the initial value, the final calibration demonstrated the consistent results whichever methods had been performed for obtaining the initial value. Furthermore, those three-dimensional coordinates of feature points of the VLBI antenna were respectively calculated using the camera calibration by the two methods to be compared with the reference coordinates obtained from a total station. In fact, both methods have resulted out a same standard deviation of $X=0.004{\pm}0.010m$, $Y=0.001{\pm}0.015m$, $Z=0.009{\pm}0.017m$, that of showing a high degree of accuracy in centimeters. From the result, we can conclude that a mobile phone camera opens up the way for a variety of image processing studies, such as 3D reconstruction from images captured.