• Title/Summary/Keyword: reduction of fouling

Search Result 136, Processing Time 0.023 seconds

Modeling of the effect of current density and contact time on membrane fouling reduction in EC-MBR at different MLSS concentration (EC-MBR 공정의 MLSS, 전류밀도 및 접촉시간이 막 오염 감소에 미치는 영향 모델링)

  • Kim, Wan-Kyu;Chang, In-Soung
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.33 no.2
    • /
    • pp.111-119
    • /
    • 2019
  • Electro-coagulation process has been gained an attention recently because it could overcome the membrane fouling problems in MBR(Membrane bio-reactor). Effect of the key operational parameters in electro-coagulation, current density(${\rho}_i$) and contact time(t) on membrane fouling reduction was investigated in this study. A kinetic model for ${\rho}_i$ and t required to reduce the membrane fouling was suggested under different MLSS(mixed liquor suspended solids) concentration. Total 48 batch type experiments of electro-coagulations under different sets of current densities(2.5, 6, 12 and $24A/m^2$), contact times(0, 2, 6 and 12 hr) and MLSS concentration(4500, 6500 and 8500mg/L) were carried out. After each electro-coagulation under different conditions, a series of membrane filtration was performed to get information on how much of membrane fouling was reduced. The membrane fouling decreased as the ${\rho}_i$ and t increased but as MLSS decreased. Total fouling resistances, Rt (=Rc+Rf) were calculated and compared to those of the controls (Ro), which were obtained from the experiments without electro-coagulation. A kinetic approach for the fouling reduction rate (Rt/Ro) was carried out and three equations under different MLSS concentration were suggested: i) ${\rho}_i^{0.39}t=3.5$ (MLSS=4500 mg/L), ii) ${\rho}_i^{0.46}t=7.0$ (MLSS=6500 mg/L), iii) ${\rho}_i^{0.74}t=10.5$ (MLSS=8500 mg/L). These equations state that the product of ${\rho}_i$ and t needed to reduce the fouling in certain amounts (in this study, 10% of fouling reduction) is always constant.

The Effect on Fouling Reduction by the Ball Cleaning System in a Compressed Type Refrigerator

  • Lee, Yoon-Pyo;Karng, Sarng-Woo
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.10 no.2
    • /
    • pp.88-96
    • /
    • 2002
  • The present study was conducted to estimate the effect on fouling reduction in tubes of the condenser. It shows in detail how to calculate the fouling factor from the experimental results of refrigeration systems with or without the automatic cleaning system using sponge balls and to predict the variation of the factor with time. It also represents how to calculate the temperature and pressure decrease of the refrigerant vapor in the condenser and the load decrease of the compressor in the refrigeration system by fouling reduction.

The Effect on Fouling Reduction by the Cleaning System in Compressed Type Refrigerator (압축식 냉동기에서 세정장치에 의한 파울링 억제효과)

  • 이윤표;강상우
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.6
    • /
    • pp.482-489
    • /
    • 2001
  • The present study was conducted to estimate the effect on fouling reduction in tubes of the condenser. It shows in detail how to calculate the fouling factor from the experimental results of refrigeration systems with or without the automatic cleaning system using sponge balls and to predict the variation of the factor with time. It also represents how to calculate the temperature and pressure decrease of the refrigerant vapor in the condenser and the load decrease of the compressor in the refrigeration system by fouling reduction.

  • PDF

Inorgainc fouling and it fouling reduction in direct contact membrane distillation process (직접 접촉식 막 증발공정에서 무기 막오염 특성 분석 및 저감방법)

  • Lee, Tae-Min;Kim, Seung-Hyun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.34 no.2
    • /
    • pp.115-125
    • /
    • 2020
  • This study was aimed to examine inorganic fouling and fouling reduction method in direct contact membrane distillation(DCMD) process. Synthetic seawater of NaCl solution with CaCO3 and CaSO4 was used for this purpose. It was found in this study that both CaCO3 and CaSO4 precipitates formed at the membrane surface. More fouling was observed with CaSO4(anhydrite) and CaSO4·0.5H2O(bassanite) than CaSO4·2H2O(gypsum). CaCO3 and gypsum were detected at the membrane surface when concentrates of SWRO(seawater reverse osmosis) were treated by the DCMD process, while gypsum was found with MED(multi effect distillation) concentrates. Air backwash(inside to out) was found more effective in fouling reduction than air scouring.

Application of high voltage pulse for reduction of membrane fouling in membrane bio-reactor and kinetic approach to fouling rate reduction (막결합형 생물반응기(Membrane Bio-Reactor)의 막 오염 저감을 위한 고전압 펄스의 적용과 막 오염 저감 속도론적 해석)

  • Kim, Kyeong-Rae;Kim, Wan-Kyu;Chang, In-Soung
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.34 no.3
    • /
    • pp.183-190
    • /
    • 2020
  • Although membrane bio-reactor (MBR) has been widely applied for wastewater treatment plants, the membrane fouling problems are still considered as an obstacle to overcome. Thus, many studies and commercial developments on mitigating membrane fouling in MBR have been carried out. Recently, high voltage impulse (HVI) has gained attention for a possible alternative technique for desalting, non-thermal sterilization, bromate-free disinfection and mitigation of membrane fouling. In this study, it was verified if the HVI could be used for mitigation of membrane fouling, particularly the internal pore fouling in MBR. The HVI was applied to the fouled membrane under different conditions of electric fields (E) and contact time (t) of HVI in order to investigate how much of internal pore fouling was reduced. The internal pore fouling resistance (Rf) after HVI induction was reduced as both E and t increased. For example, Rf decreased by 19% when the applied E was 5 kV/cm and t was 80 min. However, the Rf decreased by 71% as the E increased to 15 kV/cm under the same contact time. The correlation between E and t that needed for 20% of Rf reduction was modeled based on kinetics. The model equation, E1.54t = 1.2 × 103 was obtained by the membrane filtration data that were obtained with and without HVI induction. The equation states the products of En and t is always constant, which means that the required contact time can be reduced in accordance with the increase of E.

Effect of current density and contact time on membrane fouling in electrocoagulation-MBR and their kinetic studies on fouling reduction rate (전기응집-MBR 공정의 전류밀도와 접촉시간이 막 오염에 미치는 영향과 막 오염 저감 속도론적 고찰)

  • Um, Se-Eun;Chang, In-Soung
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.31 no.4
    • /
    • pp.321-328
    • /
    • 2017
  • Recently EC-MBR (Elctrocoagulation - Membrane Bio Reactor) has been suggested as one of alternative processes to overcome membrane fouling problems. Most important operational parameters in the EC-MBR are known to current density and contact time. Their effect on membrane filtration performances has been reported well, however, quantitative interrelationship between both parameters not been investigated yet. The purpose of this study is to give a kinetic model suggesting the current density and the contact time required to reduce the membrane fouling. The 4 different set of current densities (2.5, 6, 12 and $24A/m^2$) and contact times (0, 2, 6 and 12 hr) were selected as operational parameters. After each electro-coagulation under the 16 different conditions, a series of membrane filtration was carried out. The membrane fouling decreased as the current density and contact time increased, Total fouling resistances under different conditions, $R_t(=R_c+R_f)$ were calculated and compared to those of the controls ($R_0$), which were calculated from the data of experiments without electro-coagulation. A kinetic approach for the fouling reduction rate ($R_t/R_0$) was carried out and the equation ${\rho}^{0.46}_it=7.0$ was obtained, which means that the product of current density and the contact time needed to reduce the fouling in certain amounts (in this study, 10% of fouling reduction) is always constant.

Effect of Ozonation in Microfiltration Membrane for Wastewater Reuse (정밀여과법 하수재이용 공정에서 오존의 전처리 효과에 관한 연구)

  • Moon, Seong-Yong;Ahn, Se-Hyuk;Lee, Sang-Hyup;Park, Jong-Hoon;Hong, Suk-Won;Choi, Yong-Su
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.20 no.4
    • /
    • pp.535-543
    • /
    • 2006
  • The Ozone oxidation process was applied to increase the efficiency of reuse process when treating the secondary effluent by the membrane system. This paper focus on decreasing efficiency of membrane fouling, because of membrane fouling reduction by ozone and evaluation of application of the ozone oxidation. The feed water was secondary effluent from BNR process. The result shows that the ozone pretreatment can reduce membrane fouling effectively. Also, the improvement of treated water quality was obvious. The reduction of the membrane fouling led decrease of following pollutant and increase of lnner adsorptive ability of hydrophilic organic matter and decrease of molecular weight. MF membrane process alone can meet the domestic reuse water standards. And ozone pretreatment process also can increase the removal rates of turbidity, COD, nitrogen, and color.

Development of the Fouling-Controlled Ball Valve Used for Gas-Solid Flow (화울링 저감을 위한 분체용 볼 밸브의 개발)

  • Lee, Chan;Won, Young Shik
    • Clean Technology
    • /
    • v.11 no.4
    • /
    • pp.181-188
    • /
    • 2005
  • Developed is the new gas-solid flow ball valve where air injection purging concept is applied for the control and the reduction of particle fouling. CFD analyses are conducted for investigating the interaction between gas-sold and air injection streams and the fouling phenomena in valve, and the analysis results are reflected in the design of valve geometry and air injection condition. Through the actual tests on designed ball valve, the present valve is shown to be superior in fouling reduction.

  • PDF

Fouling Reduction Characteristics of a Fluidized Bed Heat Exchanger for Flue Gas Heat Recovery (연도가스 열회수용 순환유동층 열교환기의 오염저감특성)

  • 이금배;전용두
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.8
    • /
    • pp.770-777
    • /
    • 2004
  • Fouling and cleaning tests are performed for a uniquely designed 7,000 ㎉/hr fluidized bed heat exchanger for exhaust gas heat recovery. Fuel rich condition is maintained in the combustor for a limited time period to generate soot that is to be deposited on the heat transfer surfaces (fouling) and 600 Um glass beads are circulated inside the heat exchanger system for cleaning and enhancing the heat transfer performance. According to the present experimental study, performance degradation mode could be monitored and the effect of particle circulation on the heat transfer improvement could be identified. Through the present study, it is demonstrated that circulating particles contribute not only to the fouling reduction in gas side, but also to the heat transfer enhancement of the unit, while other possible aging factors including water side corrosion seemed to contribute to the accumulated performance deterioration.

Evaluation of Catalyst Assisted EGR Cooler System for EGR Cooler Fouling Reduction (EGR Cooler Fouling 저감을 위한 촉매 장착 EGR Cooler System 평가)

  • Hong, Kwang-Seok;Park, Jung-Soo;Lee, Kyo-Seung
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.19 no.5
    • /
    • pp.76-81
    • /
    • 2011
  • Exhaust gas recirculation is the well-known and widely used NOx reduction technology for diesel engines. More effective EGR cooler has been developed and applied to diesel engines to meet the reinforced emission regulation. However, the contaminated EGR cooler by diesel exhaust gas reduces the performance of the engine and NOx reduction rate. The buildup of deposits in EGR coolers cause significant degradation in heat transfer performance, often on the order of 20~30%. Deposits also increase pressure drop across coolers and thus may degrade engine efficiency under some operation conditions. In this study, as a solution for this problem, DOC assisted EGR cooler is designed and then investigated to reduce fouling and its impact on cooler performance. A single channel EGR cooler fouling test apparatus and soot particle generator were developed to represent the real EGR cooler and exhaust gas of diesel engine. EGR cooler effectiveness of the case with catalyst of pt 30g/ft3 decreased just up to 5%. This value was 45% less compared to the case without catalyst which decreased up to 9% after 10hours experiments.