• Title/Summary/Keyword: reduction factor.

Search Result 3,115, Processing Time 0.036 seconds

Evaluation of Creep Reduction Factor for Geosynthetic Strip Reinforcement with Folding Grooves (접힘홈이 형성된 띠형 섬유보강재의 크리프 감소계수 평가)

  • Lee, Kwang-Wu;Cho, Sam-Deok
    • Journal of the Korean Geosynthetics Society
    • /
    • v.17 no.4
    • /
    • pp.213-224
    • /
    • 2018
  • In this study, a series of accelerated creep tests (SIM) was carried out on geosynthetic strip reinforcements with folding grooves having different tensile strengths (15 kN, 25 kN, 35 kN, 50 kN, 70 kN, and 90 kN) to analyze creep characteristics and to assess creep reduction factors. In particular, long-term creep tests were conducted on geosynthetic strip reinforcements with 25 kN tensile strength, which is widely used, to compare and analyze the accelerated creep test results. As a result, the creep reduction factor increased with an increasing design life of reinforcement. In addition, geosynthetic strip reinforcement using the same material and manufacturing method showed similar creep reduction factors at the same design life for different tensile strengths. When both long-term and accelerated creep test data were used, the creep reduction factors from the accelerated test were estimated to be 5.9%~7.1% less than those from the long-term creep test for the design life ranging from 50 to 100 years.

Urban Flood Regional Safety Assesment Model (도시지역 홍수재해에 대한 지역안전도 평가모형)

  • Lee, Chang-Hee;Lee, Suk-Min;Shin, Sang-Young;Yeo, Chang-Geon;Kim, Youn-Jong
    • 한국방재학회:학술대회논문집
    • /
    • 2007.02a
    • /
    • pp.376-379
    • /
    • 2007
  • In recent years, the natural damage associated with flood disaster has been dramatically increased. However, there is no rational method which reflects urban characteristics to estimate the regional safety assessment for flood disaster. The purpose of this study is to develop the regional safety assesment model for urban flood. Flood risk and reduction assesment were estimated by using the linear sum of the Z score of the assessment factors and the weight value of each factor from the expert survey data. And then the regional safety assessment was estimated by subtracting reduction factor value from risk factor value. GIS tool was used to estimate the factor assesment and integrated regional safety. This study can be used to determine the priority of flood protection project, execute the flood insurance and establish the urban plans and the flood mitigate plan.

  • PDF

Growth and characterization of lead bromide: application to mercurous bromide

  • Kim, Geug-Tae
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.14 no.2
    • /
    • pp.50-57
    • /
    • 2004
  • Mercurous Bromide ($Hg_2Br_2$) crystals hold promise for many acousto-optic and opto-electronic applications. This material is prepared in closed ampoules by the physical vapor transport (PVT) growth method. We investigate the effects of solutal convection on the crystal growth rate in a horizontal configuration for diffusive-convection conditions and purely diffusion conditions achievable in a low gravity environment. Our results show that the growth rate is decreased by a factor of one-fourth with a ten reduction of gravitational acceleration near y = 2.0 cm. For 0.1 $g_O$ the growth rate pattern exhibits relatively flat which is intimately related to diffusion-dominated processes. The growth rate nonuniformity is regardless of aspect ratio across the interfacial positions from 0 to 1.5. Also, the effect of a factor of the ten reduction in the gravitational acceleration is same to both Ar = 5 and 2. The enlargement in the molecular weight of B from 50 to 500 by a factor 4 causes a decrease in the maximum growth rate by the same factor, indicative of the effect of solutal gradients.

Updates of Korean Design Standard (KDS) on the wind load assessment and performance-based wind design

  • Han Sol Lee;Seung Yong Jeong;Thomas H.-K. Kang
    • Wind and Structures
    • /
    • v.37 no.2
    • /
    • pp.117-131
    • /
    • 2023
  • Korea Design Standard (KDS) will be updated with two major revisions on the assessment of wind load and performance-based wind design (PBWD). Major changes on the wind load assessment are the wind load factor and basic wind speed. Wind load factor in KDS is reduced from 1.3 to 1, and mean recurrence interval (MRI) for basic wind speed increases from 100 years to 500 years considering the reduction of wind load factor. Additional modification is made including pressure coefficient, torsional moment coefficient and spectrum, and aeroelastic instability. Combined effect of the updates of KDS code on the assessment of wind load is discussed with the case study on the specified sites and building. PBWD is newly added in KDS code to consider the cases with various target performance, vortex-induced vibration, aeroelastic instability, or inelastic behavior. Proposed methods and target performance for PBWD in KDS code are introduced.

Highly Active Analogs of α-Factor and Their Activities Against Saccharomyces cerevisiae

  • Ahn, Hee Jun;Hong, Eun Young;Jin, Dong Hoon;Hong, Nam Joo
    • Bulletin of the Korean Chemical Society
    • /
    • v.35 no.5
    • /
    • pp.1365-1374
    • /
    • 2014
  • Thirteen analogs of tridecapeptide ${\alpha}$-factor (WHWLQLKPGQPMY) of Saccharomyces cerevisiae with C- or N-terminal Trp extension and isosteric replacement by Aib at position 8 and 11, Trp at position 13, D-Ala at position 9, and Orn and Glu at position 6 were synthesized and assayed for their biological activity. Receptor binding assay was carried out using our newly developed spectrophotometric method with detector peptide 14. C- or N-terminal extended analogs, ${\alpha}$-factor-$[Trp]_n$ (n =1-5) 1-5 and $[N-Trp]_1$-${\alpha}$-factor 6, were all less active than native ${\alpha}$-factor and gradual decreases in both activity and receptor affinity were observed with greater Trp extension. Trp-substituted analog at position 13, $[Trp^{13}]{\alpha}$-factor 7, exhibited about 2-fold reductions in both activity and receptor affinity. Aib-substituted analogs, $[Aib^8]{\alpha}$-factor 8 and $[Aib^{11}]{\alpha}$-factor 9, showed 5- to 10-fold reduction in activity as well as 3-fold reduction in receptor affinity compared to native ${\alpha}$-factor. $[Orn^6]{\alpha}$-factor 10 demonstrated strong potency with a 7.0-fold increase in halo activity as well as 1.8-fold increase in receptor affinity compared to native ${\alpha}$-factor. For two double substituted analogs, [$Glu^6,{\small{D}}-Ala^9$]${\alpha}$-factor 12 showed the slightly decreased potency in halo activity compared to analog 10, whereas [$Orn^6,{\small{D}}-Ala^9$]${\alpha}$-factor 11 exhibited 15-fold higher halo activity as well as nearly 3-fold higher receptor affinity compared to native ${\alpha}$-factor.

Application of Margin of Safety Considering Regional Characteristics for the Management of Total Maximum Daily Loads (지역특성을 고려한 수질오염총량관리 안전부하량 적용)

  • Park, Jun Dae;Oh, Seung Young;Kim, Yong Seok
    • Journal of Korean Society on Water Environment
    • /
    • v.30 no.3
    • /
    • pp.351-360
    • /
    • 2014
  • The allocation of margin of safety (MOS) at a uniform rate to all areas of the unit watershed makes it very difficult to keep the load allotment stable in the area for lack of reduction measures like forest land. This study developed an equation to calculate margin of safety differentially according to the regional characteristics. The equation was formulated on the basis of the regional characteristic factors such as a load contribution factor for land use type and a site conversion factor for the unit watershed. The load contribution factor represents a contribution of loads from a particular land use. The site conversion factor was derived from the site conversion ratio of a unit watershed. Margin of safety for the non-point pollution load in the land use sector decreased by 20~25% in three river basins. The margin of safety in the unit watersheds with low site occupation ratios decreased in high rate, while in the unit watersheds with large urban area decreased in low rate. With the application of the differential margin of safety considering regional characteristics, not only the reduction of pollution loads can become lighter but also it can be easier to develop plans for Total Maximum Daily Loads (TMDLs) even where the reduction measures are not available.

Evaluation of Nominal Flexural Strength in RC Beams Strengthend with CFRP Plate and Failed by Intermediate Crack Debonding (중간부 부착파괴된 CFRP 판 보강 RC 보의 휨강도 평가)

  • Hong, Sung Nam;Park, Jong In;Kim, Tae Wan;Park, Sun Kyu
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.15 no.5
    • /
    • pp.101-112
    • /
    • 2011
  • This paper shows a study carried out on the estimation of nominal flexural strength for CFRP-plated RC beams failed by intermediate crack debonding. A strength reduction factor is proposed to consider the effect of the intermediate crack debonding for the determination of nominal flexural strength. The proposed factor is derived from experimental data and utilizes the ratio of effective stress(or strain) in the CFRP plate to its ultimate strength(or strain) which is called effective strain model. An analytical equation for the estimation of the nominal flexural strength is formulated as a function of strength reduction factor. The validity, accuracy and efficiency of the proposed factor are established by comparing the analytical results with the experimental data, and the major design codes, as well as a number of factors given by researchers. The analytical results presented in this paper indicate that the proposed factor can effectively estimate the flexural nominal strength of CFRP-plated reinforced concrete beams failed by intermediate crack debonding.

Reduction Factor of the Site Coefficient due to the Foundation Embedment in the Soft Soil Layer for the Seismic Analysis of a Building (건축물의 지진해석을 위한 연약지반에 묻힌 기초로 인한 지반증폭계수에 대한 저감계수)

  • Kim, Yong-Seok
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.14 no.4
    • /
    • pp.1-15
    • /
    • 2010
  • In this study, the reduction factor of the code-defined site coefficient due to the embedment of a foundation was estimated for the seismic analysis of a building built on a soft soil site. This was done by utilizing the in-house finite element software P3DASS, which has the capability of pseudo 3D seismic analysis with nonlinear soil layers. A 30m thick soft soil site laid on the rock was assumed to be homogeneous, elastic, viscous and isotropic, and equivalent circular rigid foundations with radii of 10-70m were considered to be embedded at 0, 10, 20 and 30m in the soil layer. Seismic analyses were performed with 7 bedrock earthquake records deconvoluted from the outcrop records of which the effective ground acceleration was scaled to 0.1g. The study results showed that the site coefficients are gradually reduced except in the case of a small foundation embedded deeply in the weak soil layer, and it was estimated that the deviation of the site coefficients due to the foundation size was not significant. The standard reduction factor due to the foundation embedment were calculated adding the standard deviation to the average of 5 reduction factors calculated for 5 different foundation radii. Standard reduction factors for the site amplification factor were proposed for the practical amplification and the codes of KBC, etc., in accordance with the average shear wave velocity of the site, and the site class.

Removal and Inactivation of Viruses during Manufacture of a High Purity Antihemophilic Factor VII Concentration from Human Plasma

  • Kim, In-Seop;Choi, Yong-Woon;Lee, Sung-Rae;Woo, Hang-Sang;Lee, Soung-Min
    • Journal of Microbiology and Biotechnology
    • /
    • v.11 no.3
    • /
    • pp.497-503
    • /
    • 2001
  • The purpose of this study was to examine the efficacy and mechanism of the cryo-precipitation, solvent/detergent (S/D) treatment, monoclonal anti-FVIIIc antibody (mAb) column chromatography, Q-Sepharose column chromatography, and lyophilization involved in the manufacture of antithemophilic factor VII(GreenMono) from human plasma, in the removal and/or inactivation of blood-borne viruses. A variety of experimental model viruses for human pathogenic viruses, including the bovine viral diarrhoea virus (BVDV), bovine herpes virus (BHV), murine encephalomyocarditis virus (EMCV), and porcine parvovirus (PPV), were all selected for this study. BHV and EMCV were effectively partitioned from a factor VII during the cryo-precipitation with a log reduction factor of 2.83 and 3.24, respectively. S/D treatment using the organic solvent, tri(n-butyl) phosphate (TNBP), and the detergent, Triton X-100, was a robust and effective step in inactivating enveloped viruses. The titers of BHV and BVDV were reduced from the initial titer of 8.85 and $7.89{log_10} {TCID_50}$, respectively, reaching undetectable levels within 1 min of the S/D treatment. The mAb chromatography was the most effective step for removing nonenveloped viruses, EMCV and PPV, with the log reduction factors of 4.86 and 3.72, respectively. Q-Sepharose chromatography showed a significant efficacy for partitioning BHV, BVDV, EMCV, and PPV with the log reduction the log reduction factors of 2.32, 2.49, 2.60, and 1.33 respectively. Lyophilization was an effective step in inactivating g nonenveloped viruses rather than enveloped viruses, where the log reduction factors of BHV, BVDV, DMCV, and PPV were 1.41, 1.79, 4.76, and 2.05, respectively. The cumulative log reduction factors of BHV, BVDV, EMCV, and PPV were ${\geqq}$11.12, ${\geqq}$7.88, 15.46, and 7.10, respectively. These results indicate that the production process for GreenMono has a sufficient virus-reducing capacity to achieve a high margin of the virus safety.

  • PDF

Proposal of New Correction Factors for New and Renewable Energy Sources in Public Building (공공건축물에 적용되는 신·재생에너지원의 새로운 보정계수 제안)

  • Kim, Yun-Ho;Park, Yun-Ha;Won, An-Na;Hwang, Jung-Ha
    • Journal of the Korean Solar Energy Society
    • /
    • v.36 no.6
    • /
    • pp.13-24
    • /
    • 2016
  • The government introduced a mandatory installation system of new & renewable energy for public building to meet the target of greenhouse gas reduction and also suggest a correction factor for new renewable energy to expand the installation of various new & renewable energy systems. The introduction of correction factors, however, was followed by the reduction of installation size of new & renewable energy sources. Assuming that it was caused by a correction factor for each new renewable energy source calculated by the initial costs, this study proposed a new correction factor approach based on payback periods to reflect the technology element in the calculation process of correction factors additionally. The application results of new correction factors show that it was possible to do complex calculations including the economic and technological aspects to select a new & renewable energy system and that the installation size was also enlarged.