• Title/Summary/Keyword: reduction factor.

Search Result 3,115, Processing Time 0.047 seconds

The Effect on Fouling Reduction by the Ball Cleaning System in a Compressed Type Refrigerator

  • Lee, Yoon-Pyo;Karng, Sarng-Woo
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.10 no.2
    • /
    • pp.88-96
    • /
    • 2002
  • The present study was conducted to estimate the effect on fouling reduction in tubes of the condenser. It shows in detail how to calculate the fouling factor from the experimental results of refrigeration systems with or without the automatic cleaning system using sponge balls and to predict the variation of the factor with time. It also represents how to calculate the temperature and pressure decrease of the refrigerant vapor in the condenser and the load decrease of the compressor in the refrigeration system by fouling reduction.

Analysis on Magnetic Field Reduction Factor of Transmission Lines (송전선로 전자계 저감 Field Reduction Factor 분석)

  • Myung, S.H.;Cho, Y.G.;Jung, Y.H.;Lee, D.I.;Sin, G.Y.;Yoo, Y.P.
    • Proceedings of the KIEE Conference
    • /
    • 2003.10a
    • /
    • pp.12-14
    • /
    • 2003
  • 본 연구에서는 우리나라의 송전선로에 주로 적용하고 있는 역상수직 2회선 배열을 기본 모델로 하여 다양한 저감 설계기술 적용시의 FRF(Field Reduction Factor)를 구하는데 중점을 두었다. 검토한 결과로는 신규선로 저감기술로서는 송전선로의 경우 지상고 증가, Compact Tower개발, Diamond Tower의 채용, 일부 구간의 Transposed 선로배치 등이 우리나라에서 적용 가능한 후보군으로 분석되었다.

  • PDF

The Effect on Fouling Reduction by the Cleaning System in Compressed Type Refrigerator (압축식 냉동기에서 세정장치에 의한 파울링 억제효과)

  • 이윤표;강상우
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.6
    • /
    • pp.482-489
    • /
    • 2001
  • The present study was conducted to estimate the effect on fouling reduction in tubes of the condenser. It shows in detail how to calculate the fouling factor from the experimental results of refrigeration systems with or without the automatic cleaning system using sponge balls and to predict the variation of the factor with time. It also represents how to calculate the temperature and pressure decrease of the refrigerant vapor in the condenser and the load decrease of the compressor in the refrigeration system by fouling reduction.

  • PDF

Biaxial creep property of ethylene tetrafluoroethylene (ETFE) foil

  • Li, Yintang;Wu, Minger
    • Structural Engineering and Mechanics
    • /
    • v.54 no.5
    • /
    • pp.973-986
    • /
    • 2015
  • Ethylene tetrafluoroethylene (ETFE) foil is a novel structural material which has being used in shell and spatial structures. This paper studies biaxial creep property of ETFE foil by creep tests and numerical simulation. Biaxial creep tests of cruciform specimens were performed using three stress ratios, 1:1, 2:1 and 1:2, which showed that creep coefficients in biaxial tension were much smaller than those in uniaxial one. Then, a reduction factor was introduced to take account of this biaxial effect, and relation between the reduction factor and stress ratio was established. Circular bubble creep test and triangle cushion creep test of ETFE foil were performed to verify the relation. Interpolation was adopted to consider creep stress and reduction factor was involved to take account of biaxial effect in numerical simulation. Simulation results of the bubble creep test embraced a good agreement with those measuring ones. In triangle cushion creep test, creep displacements from numerical simulation showed a good agreement with those from creep test at the center and lower foil measuring points.

Comparison Analysis of Factor of Safety on Rock Slope in Boeun Region Using Limit Equilibrium Method and Distinct Element Method (한계평형법과 개별요소법을 이용한 보은지역 암반사면 안전율 비교해석)

  • 이지수;유광호;박혁진;민경덕
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2002.03a
    • /
    • pp.643-650
    • /
    • 2002
  • The large planar failure has occurred in a rock cut slope of highway construction site in Boeun. This area is considered as unstable since the discontinuities whose orientations are similar to the orientation of the failure plane, are observed in many areas. Therefore, several analysis techniques such as SMR, stereographic analysis, limit equilibrium, numerical analysis, which are commonly used in rock slope stability analysis, are adopted in this area. In order to analyze the stress redistribution and nonlinear displacement caused by cut, which are not obtained in limit equilibrium method, the UDEC and shear strength reduction technique were used in this study Then the factors of safety evaluated by shear strength reduction technique and limit equilibrium were compared. In addition, the factor of safety under fully saturated slope condition was calculated and subsequently, the effect of the reinforcement was evaluated.

  • PDF

Downsizing of Gap Filler for Satellite DMB using Crest Factor Reduction Technology (Crest Factor Reduction기술을 이용한 위성 DMB용 Gap Filler 소형화 개발)

  • Lee, Hak-Yong;Lee, Hong-Bae;Lee, Young-Su
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2005.08a
    • /
    • pp.128-132
    • /
    • 2005
  • 각종 신호의 디지털 전송에서 Modulation기법에 의해 발생되는 PAPR(Peak to Average Power Ratio)은 전송 신호의 선형성을 보장하기 위하여 고출력 증폭기의 Back-off를 요구하게 된다. 이러한 고출력 증폭기의 Back-off요구로 인하여 원하는 출력에 비해 높은 전력소모량이 필요하여 대출력을 요구하는 장비의 소형화는 크게 제한을 받게 된다. 본 논문에서는 PAR을 감소하기 위한 CFR(Crest Factor Reduction)기법을 위성 DMB용 Gap Filler에 적용하여 장비 크기를 소형화한 사례에 대해 소개한다. 전송신호의 품질에 대한 영향을 최소화 하면서 PAR을 감소하기 위한 방안을 위해 도입된 Simulation 결과와 CFR기법을 적용한 장비에 대한 성능시험 결과 및 필드 테스트 결과에 대해 소개한다.

  • PDF

Coprime factor reduction of plant in $H{\infty}$ mixed sensitivity problem

  • Um, Tae-Ho;Oh, Do-Chang;Park, Hong-Bea;Kim, Soo-Joong
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1995.10a
    • /
    • pp.340-343
    • /
    • 1995
  • In this paper, we get a reduced order controller in $H^{\infty}$ mixed sensitivity problem with weighting functions. For this purpose, we define frequency weighted coprime factor of plant in $H^{\infty}$ mixed sensitivity problem and reduce the coprime factor using the frequency weighted balanced truncation technique. The we design the controller for plant with reduced order coprime factor using J-lossless coprime factorization technique. Using this approach, we can derive the robust stability condition and achieve good performance preservation in the closed loop system with reduced order controller. And it behaves well in both stable plant and unstable plant.t.

  • PDF

Image Optimization of Fast Non Local Means Noise Reduction Algorithm using Various Filtering Factors with Human Anthropomorphic Phantom : A Simulation Study (인체모사 팬텀 기반 Fast non local means 노이즈 제거 알고리즘의 필터링 인자 변화에 따른 영상 최적화: 시뮬레이션 연구)

  • Choi, Donghyeok;Kim, Jinhong;Choi, Jongho;Kang, Seong-Hyeon;Lee, Youngjin
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.3
    • /
    • pp.453-458
    • /
    • 2019
  • In this study we analyzed the tendency of the image characteristic by changing filtering factor for the proposed fast non local means (FNLM) noise reduction algorithm with designed Male Adult mesh (MASH) phantom through Geant4 application for tomographic emission (GATE) simulation program. To accomplish this purpose, MASH phantom for human copy was designed through the GATE simulation program. In addition, we acquired degraded image by adding Gaussian noise with a value of 0.005 using the MATALB program in MASH phantom. Moreover, in degraded image, the FNLM noise reduction algorithm was applied by changing the filtering factors, which set to 0.005, 0.01, 0.05, 0.1, 0.5, and 1.0 value, respectively. To quantitatively evaluate, the coefficient of variation (COV), signal to noise ratio (SNR), and contrast to noise ratio (CNR) were calculated in reconstructed images. Results of the COV, SNR and CNR were most improved in image with a filtering factor of 0.05 value. Especially, the COV was decreased with increasing filtering factor, and showed nearly constant values after 0.05 value of the filtering factor. In addition, SNR and CNR were showed that improvement with increasing filtering factor, and deterioration after 0.05 value of the filtering factor. In conclusion, we demonstrated the significance of setting the filtering factor when applying the FNLM noise reduction algorithm in degraded image.

Seismic force reduction factor for steel moment resisting frames with supplemental viscous dampers

  • Serror, M. Hassanien;Diab, R. Adel;Mourad, S. Ahmed
    • Earthquakes and Structures
    • /
    • v.7 no.6
    • /
    • pp.1171-1186
    • /
    • 2014
  • Damping is one of the parameters that control the performance of structures when they are subjected to seismic, wind, blast or other transient shock and vibration disturbances. By adding supplemental viscous dampers, the energy input from a transient deformation is absorbed, not only by the structure itself, but also by the supplemental dampers. The aim of this study is to evaluate the values of both damping and ductility reduction factors for steel moment resisting frames with supplemental linear viscous dampers. Two-dimensional finite element models have been established for a range of low to mid rise buildings with different parameters: number of floors; number of bays; and number of dampers with different supplemental damping ratios (from 5% to 30%). A parametric study has been performed using time history analyses and a well-documented research method (N2-method). In addition, an equation has been proposed for each reduction factor based on regression analysis for the obtained results. The results of the Time history analyses are compared with those of a modified N2-method. Moreover, a comparison with values specified in the European code EC8 and the Egyptian code ECP-201 has been performed.

An Application of Strength Reduction Factors to Reinforced Concrete Columns considering Ductility (연성을 고려한 철근콘크리트 기둥의 강도감소계수 적용에 관한 연구)

  • 손혁수;이재훈
    • Journal of the Korea Concrete Institute
    • /
    • v.11 no.4
    • /
    • pp.147-156
    • /
    • 1999
  • Current design code states that the strength reduction factor shall be permitted to be increased linearly from that for axial compression to that for flexure as the design axial load strength $\Phi$cPn decrease from 0.1fckAg to zero. Since this empirically adopted axial load level of $\Phi$cPn=0.1fckAg considers only sectional area and concrete strength, the other variables such as steel ratio, steel yielding strength, and steel arrangement can not be considered. This research is performed to investigate the consistency and the rationality of the code requirement for determination of column design strength. A nonlinear axial force-moment-curvature analysis was conducted in order to investigate the ductility of reinforced concrete column sections. As the result of ductility analysis, it was found that the ductility at the axial force of $\Phi$cPn=0.1fckAg represented a lock of consistency for the various variable contained sections. Therefore, a more reasonable application method of strength reduction factor is proposed, that is based on the strain ductility index.