• Title/Summary/Keyword: reduction device

Search Result 1,286, Processing Time 0.026 seconds

A Study on the Nutrient Composition and Heavy Metal Contents in Livestock Manure Compost·Liquefied Fertilizer (가축분뇨 퇴비·액비의 비료성분 및 중금속 함량에 관한 연구)

  • Ahn, Taeung;Kim, Dongmin;Lee, Heungsoo;Shin, Hyunsang;Chung, Eugene
    • Journal of Korean Society on Water Environment
    • /
    • v.37 no.4
    • /
    • pp.306-314
    • /
    • 2021
  • The application of organic fertilizer could be accompanied by potential hazards to soil and humans due to trace metals. Livestock manure compost·liquefied fertilizer is a well-established approach for the stabilization of nutrients and the reduction of pathogens and odors in manures, which can be evaluated as compost·liquefied. In this study, the livestock manure compost·liquefied fertilizers produced at 333 liquid manure public resource centers and liquid fertilizer distribution centers were collected from May to December 2019. The nutrient content (nitrogen, phosphorus, and potassium), physicochemical properties, and heavy metal content were investigated. The livestock manure compost·liquefied fertilizer was measured using a mechanical maturity measurement device. The organic matter, arsenic, cadmium, mercury, lead, chromium, copper, nickel, zinc, E. coli (O157:H7), Salmonella, etc. of the livestock manure compost·liquefied fertilizers were analyzed. The average heavy metal content in the livestock manure compost·liquefied fertilizer was as follows: Cr 2.9 mg/kg (0.2~8.7 mg/kg), Cu 20.4 mg/kg (1.6~74.1 mg/kg), Ni 1.3 mg/kg (0.4~4.2 mg/kg), and Zn 79.8 mg/kg (3.0~340.7 mg/kg). Although large-scale organic fertilizer plants and resources recycling centers produce good organic (liquid) fertilizers with proper components, it is necessary to standardize livestock manure compost·liquefied fertilizer in order to facilitate efforts to turn livestock manure into useful resources.

The Method to Reduce the Driving Time in (sLa-Camera-pRd) type ((sLa-Camera-pRd)타입의 구동시간 단축 방법)

  • Kim, Soon-Ho;Kim, Chi-Su
    • Journal of the Korea Convergence Society
    • /
    • v.9 no.12
    • /
    • pp.1-7
    • /
    • 2018
  • Gentry is responsible for moving the fine chip in the device that mounts the chip on the PCB. However, it is not easy to increase productivity because of the mechanical limitations of the gantry. Therefore, in this paper, we try to solve the method to increase the productivity by software. For this purpose, we propose a method to improve the productivity by shortening the movement time of the gantry. First, we calculated the total travel time for the current method(stop-motion). In addition, the total travel time is also calculated for the travel time reduction method presented in this paper. This method reduces the travel time by checking parts without stopping in front of the camera. As a result, we showed that the proposed method shortened the time of 16%. In the future, we will study time calculation methods for other types.

Development and CFD Analysis of a New Type Pre-Swirl Duct for 176k Bulk Carrier (176k Bulk Carrier에 대한 신개념 타입의 Pre-Swirl Duct의 개발 및 CFD 해석)

  • Yoo, Gwang Yeol;Kim, Moon Chan;Shin, Yong Jin;Shin, Irok;Kim, Hyun Woong
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.56 no.4
    • /
    • pp.373-382
    • /
    • 2019
  • This paper shows numerical results for the estimation of the propulsor efficiency of Pre-Swirl Duct for 176k bulk carrier as well as its design method. Reynolds averaged Navier-Stokes equations have been solved and the k-epsilon model applied for the turbulent closure. The propeller rotating motion is determined using a sliding mesh technique. The design process is divided into each part of Pre-Swirl Duct, duct and Pre-Swirl Stator. The design of duct was performed first because it is located further upstream than Pre-Swirl Stator. The distribution of velocity through the duct was analyzed and applied for the design of Pre-Swirl Stator. The design variables of duct include duct angle, diameter, and chord length. Diameter, chord length, equivalent angle are considered when designing the Pre-Swirl Stator. Furthermore, a variable pitch angle stator is applied for the final model of Pre-Swirl Duct. The largest reduction rate of the delivered power in model scale is 7.6%. Streamlines, axial and tangential velocities under the condition that the Pre-Swirl Duct is installed were reviewed to verify its performance.

3.3kV Low Resistance 4H-SiC Semi-SJ MOSFET (3.3kV급 저저항 4H-SiC Semi-SJ MOSFET)

  • Cheon, Jin-Hee;Kim, Kwang-Soo
    • Journal of IKEEE
    • /
    • v.23 no.3
    • /
    • pp.832-838
    • /
    • 2019
  • In this paper, 4H-SiC MOSFET, the next generation power semiconductor device, was studied. In particular, Semi-SJ MOSFET structures with improved electrical characteristics than conventional DMOSFET structures were proposed in the class of 3300V, and static characteristics of conventional and proposed structures were compared and analyzed through TCAD simulations. Semi-SuperJunction MOSFET structure is partly structure that introduces SuperJunction, improves Electric field distribution through the two-dimensional depletion effect, and increases breakdown voltage. Benefit from the improvement of breakdown voltage, which can improve the on resistance as high doping is possible. The proposed structure has a slight reduction in breakdown voltage, but has an 80% decrease in on resistance compared to the conventional DMOSFET structure, and a 44% decrease in on resistance compared to the Current Spreading Layer(CSL) structure that improves the conventional DMOSFET structure.

Effect of regional emergency medical access on the death rate of elderly individuals with ischemic heart disease (지역별 응급의료접근성이 노인의 허혈성 심장질환 사망률에 미치는 영향)

  • Ko, Eunjung;Cho, Keun-Ja
    • The Korean Journal of Emergency Medical Services
    • /
    • v.25 no.2
    • /
    • pp.19-38
    • /
    • 2021
  • Purpose: This study aimed to investigate the relationship between emergency medical service accessibility in different regions and the sudden death rate in elderly patients with ischemic heart disease using data analysis techniques and suggest improvements in regional emergency medical services. Methods: The study collected data from the NEDIS database and Statistics Korea. Data on a total of 75,867 patients aged ≥65 years were reviewed among patients with ischemic heart disease who visited emergency medical institutions in 2018. Frequency analysis, chi-square test, multiple logistic regression analysis, and simple logistic regression analysis were performed using SPSS PC Window 25.0. Results: With an emergency medical resource per 100km2, there was a concomitant reduction in the risk of death. There was a decrease in the death rate by 0.967, 0.970, 0.997, and 0.391 times with the increase in the presence of a fire department, an ambulance, a paramedic, and a regional medical center, respectively. Furthermore, a decrement in the death rate was witnessed 0.844, 0.825, and 0.975 times with the initiation of a local emergency medical center, a local emergency medical institution, and an angiography device, respectively(p <.001). Conclusion: To improve the accessibility of emergency medical services, the population and geometric area of the region should be considered essential factors when deploying emergency medical resources.

Pattern Formation of Highly Ordered Sub-20 nm Pt Cross-Bar on Ni Thin Film (Ni 박막 위 20 nm급 고정렬 Pt 크로스-바 구조물의 형성 방법)

  • Park, Tae Wan;Jung, Hyunsung;Cho, Young-Rae;Lee, Jung Woo;Park, Woon Ik
    • Korean Journal of Metals and Materials
    • /
    • v.56 no.12
    • /
    • pp.910-914
    • /
    • 2018
  • Since catalyst technology is one of the promising technologies to improve the working performance of next generation energy and electronic devices, many efforts have been made to develop various catalysts with high efficiency at a low cost. However, there are remaining challenges to be resolved in order to use the suggested catalytic materials, such as platinum (Pt), gold (Au), and palladium (Pd), due to their poor cost-effectiveness for device applications. In this study, to overcome these challenges, we suggest a useful method to increase the surface area of a noble metal catalyst material, resulting in a reduction of the total amount of catalyst usage. By employing block copolymer (BCP) self-assembly and nano-transfer printing (n-TP) processes, we successfully fabricated sub-20 nm Pt line and cross-bar patterns. Furthermore, we obtained a highly ordered Pt cross-bar pattern on a Ni thin film and a Pt-embedded Ni thin film, which can be used as hetero hybrid alloy catalyst structure. For a detailed analysis of the hybrid catalytic material, we used scanning electron microscope (SEM), transmission electron microscope (TEM) and energy-dispersive X-ray spectroscopy (EDS), which revealed a well-defined nanoporous Pt nanostructure on the Ni thin film. Based on these results, we expect that the successful hybridization of various catalytic nanostructures can be extended to other material systems and devices in the near future.

Effectiveness of virtual reality immersion on procedure-related pain and anxiety in outpatient pain clinic: an exploratory randomized controlled trial

  • Joo, Young;Kim, Eun-Kyung;Song, Hyun-Gul;Jung, Haesun;Park, Hanssl;Moon, Jee Youn
    • The Korean Journal of Pain
    • /
    • v.34 no.3
    • /
    • pp.304-314
    • /
    • 2021
  • Background: The study investigated virtual reality (VR) immersion in alleviating procedure-related pain in patients with chronic pain undergoing fluoroscopy-guided minimally-invasive intervention in a prone position at an outpatient clinic. Methods: In this prospective randomized controlled study, 38 patients undergoing lumbar sympathetic ganglion block were randomized into either the VR or the control group. In the VR group, procedure-related pain was controlled via infiltration of local anesthetics while watching a 30-minute VR hypnotic program. In the control group, the skin infiltration alone was used, with the VR device switched off. The primary endpoint was an 11-point score on the numerical rating scale, indicating procedure-related pain. Patients' satisfaction with pain control, anxiety levels, the need for additional local anesthetics during the procedure, hemodynamic stability, and any adverse events were assessed. Results: Procedure-related pain was significantly lower in the VR group (3.7 ± 1.4) than in the control group (5.5 ± 1.7; P = 0.002). Post-procedural anxiety was lower in the VR group than in the control group (P = 0.025), with a significant reduction from pre-procedural anxiety (P < 0.001). Although patients' satisfaction did not differ significantly (P = 0.158) between the groups, a higher number of patients required additional local anesthetics in the control group (n = 13) than in the VR group (n = 4; P = 0.001). No severe adverse events occurred in either group during the study. Conclusions: VR immersion can be safely used as a novel adjunct to reduce procedural pain and anxiety during fluoroscopic pain intervention.

Anti-inflammatory Effects of Low-frequency Stimulator using Superposition of Alternating Microcurrent Wave in the Animal Models

  • Kim, Yoo-Jeong;Lee, Seong gwang;Go, Shin Jee;An, Suyeon;Kim, Ye eun;Kim, Ye in;Hyun, Kyung-Yae;Cho, Dong Shik;Choi, Go-Eun
    • Biomedical Science Letters
    • /
    • v.27 no.2
    • /
    • pp.99-104
    • /
    • 2021
  • Treatment techniques that affect homeostasis by non-invasive regulation in peripheral organs will advance disease research. Here, we demonstrate a non-invasive method of conditioning within an organ using a low-frequency stimulator superposition of alternating microcurrent wave in stages. It is first applied to the inflammatory response in H3N2-infected sinusitis mice. To check the progress of the treatment, mice were sacrificed every week for 3 weeks, nasal tissue was removed, and the inflammatory response was investigated through H & E staining. The low-frequency stimulation treatment group was found to alleviate the proliferation of epithelial cells and invasion of inflammatory cells compared to the control group as the passage of treatment time. The reduction of inflammatory cytokines in the nasal lavage fluid was observed in H3N2-infected sinusitis mice treated with of low-frequency stimulation using superposition of alternating microcurrent wave compared to H3N2-infected sinusitis mice after 3 weeks. These data demonstrate that low-frequency stimulation device in the form of using alternating current wave superposition on within organs provides a new method to regulate specific physiological functions. Therefore, it is necessary to prove the inhibitory effect of low-frequency stimulation using alternating current wave superposition on inflammatory diseases by various methods through further studies and clinical studies.

Development and Field-evaluation of Automatic Spreader for Bedding Materials in Duck Houses (오리사 바닥 깔짚자동살포장치 개발 및 실증)

  • Kwon, Kyeong-seok;Woo, Jae-seok;Noh, Je-hee;Oh, Sang-ik;Kim, Jong-bok;Kim, Jung-kon;Yang, Kayoung;Jang, Donghwa;Choi, Sungmin
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.63 no.1
    • /
    • pp.37-48
    • /
    • 2021
  • The automatic-spreader of bedding materials was developed to reduce labor cost, and to achieve successful biosecurity in duck houses. Algorithm of the device was designed to realize a concept of the automatic unmanned operation including entire processes such as loading and spreading of the bedding materials. From the field measurement, the relationship between the expected water content reduction and weight of bedding materials per unit area according to the operation condition of the devices was induced. In the case of the measurement of particulate matters during the process of spreading works, the results of using both conventional manual-spreader and automatic-spreader were exceeded the allowable limit of inhalable and respirable dust, respectively. But, workers using automatic-spreader could be free from harmful aero-condition because they did not stay inside the facility during the spreading works. In addition, from the Duck hepatitis virus PCR test, influence on pulmonary tissue of the duck was not found. It could be expected that the development of the automatic-spreader of bedding materials for duck house can contribute to the advancement of duck breeding facilities.

Effect of High-frequency Diathermy on Hamstring Tightness

  • Kim, Ye Jin;Park, Joo-Hee;Kim, Ji-hyun;Moon, Gyeong Ah;Jeon, Hye-Seon
    • Physical Therapy Korea
    • /
    • v.28 no.1
    • /
    • pp.65-71
    • /
    • 2021
  • Background: The hamstring is a muscle that crosses two joints, that is the hip and knee, and its flexibility is an important indicator of physical health in its role in many activities of daily living such as sitting, walking, and running. Limited range of motion (ROM) due to hamstring tightness is strongly related to back pain and malfunction of the hip joint. High-frequency diathermy (HFD) therapy is known to be effective in relaxing the muscle and increasing ROM. Objects: To investigate the effects of HFD on active knee extension ROM and hamstring tone and stiffness in participants with hamstring tightness. Methods: Twenty-four participants with hamstring tightness were recruited, and the operational definition of hamstring tightness in this study was active knee extension ROM of below 160° at 90° hip flexion in the supine position. HFD was applied to the hamstring for 15 minutes using the WINBACK device. All participants were examined before and after the intervention, and the results were analyzed using a paired t-test. The outcome measures included knee extension ROM, the viscoelastic property of the hamstring, and peak torque for passive knee extension. Results: The active knee extension ROM significantly increased from 138.8° ± 9.9° (mean ± standard deviation) to 143.9° ± 10.4° after the intervention (p < 0.05), while viscoelastic property of the hamstring significantly decreased (p < 0.05). Also, the peak torque for knee extension significantly decreased (p < 0.05). Conclusion: Application of HFD for 15 minutes to tight hamstrings immediately improves the active ROM and reduces the tone, stiffness, and elasticity of the muscle. However, further experiments are required to examine the long-term effects of HFD on hamstring tightness including pain reduction, postural improvement around the pelvis and lower extremities, and enhanced functional movement.