An ASIC implementation of a Dual Channel Acoustic Beamforming for MEMS microphone in 0.18㎛ CMOS technology (0.18㎛ CMOS 공정을 이용한 MEMS 마이크로폰용 이중 채널 음성 빔포밍 ASIC 설계)

  • Jang, Young-Jong;Lee, Jea-Hack;Kim, Dong-Sun;Hwang, Tae-ho
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.13 no.5
    • /
    • pp.949-958
    • /
    • 2018
  • A voice recognition control system is a system for controlling a peripheral device by recognizing a voice. Recently, a voice recognition control system have been applied not only to smart devices but also to various environments ranging from IoT(: Internet of Things), robots, and vehicles. In such a voice recognition control system, the recognition rate is lowered due to the ambient noise in addition to the voice of the user. In this paper, we propose a dual channel acoustic beamforming hardware architecture for MEMS(: Microelectromechanical Systems) microphones to eliminate ambient noise in addition to user's voice. And the proposed hardware architecture is designed as ASIC(: Application-Specific Integrated Circuit) using TowerJazz $0.18{\mu}m$ CMOS(: Complementary Metal-Oxide Semiconductor) technology. The designed dual channel acoustic beamforming ASIC has a die size of $48mm^2$, and the directivity index of the user's voice were measured to be 4.233㏈.

Efficacy Evaluation of Magnetic P. (자기장을 활용한 통증치료기의 효력평가)

  • Yoon, Yoo-Sik;Kim, Sun-Hyoung;Choi, Sun-Mi;Moon, Jin-Seok;Kang, Dong-Kun;Kim, Young;Ahn, Young-Bok;Lee, Jong-Cheol;Jung, Woo-Jin
    • Korean Journal of Oriental Medicine
    • /
    • v.9 no.2
    • /
    • pp.121-130
    • /
    • 2003
  • The goal of this study is construction and efficacy evaluation of MPC-25 (Magnetic Pain Control-25), a medical device using magnetic stimulation. MPC-25 consists of a main body containing power supply and control module and a bed containing magnetic core and coil. In distinction from electric pain control medical devices, magnetic pain control system is non-contact, so the patients need not take off their clothes to be treated. High amplitude current pulses are applied to a magnetic coil and induce time varying magnetic field generating eddy current in a conductor like human body. Clinical efficacy test was performed in patients suffering from musculoskeletal pain of lumbar, shoulder and joint. Degree of pain before and after treatment for 30 minutes was compared using Visual Analogous Scale. As a result, 14 cases out of 20 showed decreased pain perception, so the rate of efficacy is 70%. Reduction of pain perception was statistically significant (P=0.001 by Wilcoxon Signed Rank Test).

  • PDF

Multi-objective Optimal Design using Genetic Algorithm for Semi-active Fuzzy Control of Adjacent Buildings (인접건물의 준능동 퍼지제어를 위한 유전자알고리즘 기반 다목적 최적설계)

  • Kim, Hyun-Su
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.1
    • /
    • pp.219-224
    • /
    • 2016
  • The vibration control performance of a semi-active damper connected to adjacent buildings subjected to seismic loads was investigated. The MR damper was used as a semi-active control device. A fuzzy logic control algorithm was used for effective control of the adjacent buildings connected to the MR damper. In the buildings control coupled with a MR damper, the response reduction of one building results in an increase in the response in another building. Because of these conflict characteristics, multi-objective optimization is required. Therefore, a fuzzy logic control algorithm for the control of a MR damper was optimized using a multi-objective genetic algorithm. Based on numerical analyses, the semi-active fuzzy control of MR damper for adjacent coupled buildings can provide good control performance.

DC Traction Regenerative Energy Storage Devices using Super-capacitor (슈퍼 커패시터를 이용한 직류철도 회생에너지 저장장치)

  • Kim, Jong-Yoon;Jung, Doo-Yong;Jang, Su-Jin;Lee, Byoung-Kuk;Won, Chung-Yuen
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.13 no.4
    • /
    • pp.247-256
    • /
    • 2008
  • Regenerative energy generated by regenerative braking of DC traction can cause the system malfunction or damage to the rectifier, or malfunction of the power conversion device in power supply system by DC Line voltage rise in feeder line. Regenerative energy storage system using super capacitor is one of the ways to stabilize DC line voltage. In this paper, energy storage system of DC traction system using super-capacitor bank is implemented and using the field measurement data of the station N and the station S on the Line 2, the operation characteristics of line voltage caused by regenerative energy of electric trains are verified. Also, charge/discharge characteristics of super capacitor are verified as well. Thus, we can verify the operation characteristics of super-capacitor bank for regenerative energy storage system installed in DC Traction. And if we can use field measurement data of DC line voltage, we have obtained cost reduction. The stabilization of the system will be improved by measuring the operation characteristics of regenerative energy storage system in certain section operated by DC traction and predicting the capacity and lifetime of super-capacitor.

Development of Dry Paddy Seeder of Strip Tillage (부분경운 건답직파기 개발)

  • 박석호;이동현;김학진;이채식;곽태용;조성찬
    • Journal of Biosystems Engineering
    • /
    • v.27 no.1
    • /
    • pp.25-32
    • /
    • 2002
  • This study was conducted to develop a dry paddy seeder of strip tillage. The prototype is 8 rows drill seeder, which is composed of a strip tillage, sowing and fertilizing device, and pressing wheels to do the strip tillage, sowing, fertilizing, and draining ditch, simultaneously. The performances of prototype was evaluated through the investigation of fuel consumption, tillage torque, ratio of soil breaking, and economical efficiency and the results were compared with these of a dry paddy seeder that needs whole tillage. According to the USDA textural classification, the experiment field was composed of sandy loam which consisted of 56.8 of sand, 30.2 of silt and 13.0 % of clay, respectively. Its hardness ranged from 952 to 1,673 kPa depending on the soil depth, and its soil moisture content was 24.9%(d. b.) Fuel consumption of the prototype was 5,015g/hr at 2,000 rpm of engine, which was consequently 64% smaller than that of the conventional dry paddy seeder. For the tillage torque, it ranged from 132 to 206N$.$m depending on the tillage pitch, which was 10∼30% smaller than that of the conventional dry paddy seeder. The ratio of soil braking of the prototype was 87∼98%, whereas that of the conventional dry paddy seeder was 80∼97%. The working performance of the prototype was surveyed to be 3.8hours/ha, which was about 5 times higher than that of the conventional dry paddy seeder. The cost reduction of 26.3% was obtained by using the prototype.

Reliability Analysis with Space Radiation of Low-Cost COTS Small Satellite (우주방사능 효과를 고려한 저가 COTS 소형위성의 신뢰성 분석)

  • Jeong, Ji-Wan;Jang, Yeong-Geun;Mun, Byeong-Yeong
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.34 no.2
    • /
    • pp.56-67
    • /
    • 2006
  • The reliability and failure mode effect analysis are effective means to achieve efficient and cost-reduction design for satellite development. The failure rate of COTS (Commercial-Off-The-Shelf) parts required for reliability analysis is not usually provided from the manufacturer. Space environment factors based on empirical data obtained from MIL-HDBK-217F can be applicable to the reliability calculation. As a radiation environment factor, the occurrence rate of SEL (Single Event Latch-up) is additionally incorporated for the failure rate prediction. In this paper, the statistical reliability analysis method for low-cost small satellite using COTS parts is suggested. This statistical reliability analysis was applied to HAUSAT-2 small satellite whose electronic boxes are consisted of many COTS parts to calculate the system reliability at the end of design mission life.

Hardware Design of High Performance ALF in HEVC Encoder for Efficient Filter Coefficient Estimation (효율적인 필터 계수 추출을 위한 HEVC 부호화기의 고성능 ALF 하드웨어 설계)

  • Shin, Seungyong;Ryoo, Kwangki
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.19 no.2
    • /
    • pp.379-385
    • /
    • 2015
  • This paper proposes the hardware architecture of high performance ALF(Adaptive Loop Filter) for efficient filter coefficient estimation. In order to make the original image which has high resolution and high quality into highly compressed image effectively and also, subjective image quality into improved image, the ALF technique of HEVC performs a filtering by estimating filter coefficients using statistical characteristics of image. The proposed ALF hardware architecture is designed with a 2-step pipelined architecture for a reduction in performance cycle by analysing an operation relationship of Cholesky decomposition for the filter coefficient estimation. Also, in the operation process of the Cholesky decomposition, a square root operation is designed to reduce logic area, computation time and computation complexity by using the multiplexer, subtracter and comparator. The proposed hardware architecture is designed using Xilinx ISE 14.3 Vertex-7 XC7VCX485T FPGA device and can support 4K UHD@40fps in real time at a maximum operation frequency of 186MHz.

Experimental and Numerical Investigation of the Performance of Vertical Thermosyphon for Frozen Ground Stabilization (실험과 수치해석을 통한 동토지반 안정화용 수직형 열사이펀의 성능평가)

  • Lee, Jangguen;Lee, Chulho;Jang, Changkyu;Choi, Changho
    • Journal of the Korean Geosynthetics Society
    • /
    • v.13 no.4
    • /
    • pp.45-56
    • /
    • 2014
  • Frozen ground in cold region consists of an upper active layer and lower permafrost which is permanently frozen land. During the summer season, the air temperature is high enough to make the frozen ground melt, which causes the reduction of soil strength and thaw settlement. These phenomena result in structural instability, so it is necessary to apply frozen ground stability techniques. Thermosyphon is a closed natural two-phase convection device to maintain the ground temperature below $0^{\circ}C$ by extracting heat from the ground and discharges it into the atmosphere. Experimental and numerical investigation has been performed to estimate the effect of the refrigerant filling ratio in thermosyphon using R-134a refrigerant and the thermal conductance of the thermosyphon.

Analysis of the Characteristics of Flue Gas in Infrared Mobile Heaters for Gas Room Heating (가스난방용 적외선 히터의 연소배기가스 특성해석)

  • Kim Young-Gyu;Kwon Jeong-Rock;Kim Chung-Kyun
    • Journal of the Korean Institute of Gas
    • /
    • v.2 no.1
    • /
    • pp.66-73
    • /
    • 1998
  • This paper deals with the combustion characteristics of flue gas in infared mobile heaters. The experimental work has been performed to obtain the concentration levels and combustion characteristics of flue gas with varying chamber size and room temperature. The experimental results showed that oxygen depletion sensor device was operated at the oxygen concentration level of $18.3\%$ for all the chamber size. The combustion characteristics of oxygen and carbon dioxide show a linearity After 10 minutes the combustion property of carbon monoxide occurs at random without a level of oxygen and carbon dioxide in closed space of the heater. In these results, it is very important to prevent incomplete combustion through a sufficient ventilation, and accident prevention with a reduction of the oxygen and diffusion of toxic carbon monoxide.

  • PDF

Structural and electrical characteristics of IZO thin films deposited under different ambient gases (분위기 가스에 따른 IZO 박막의 구조적 및 전기적 특성)

  • Lee, Yu-Lim;Lee, Kyu-Mann
    • Journal of the Semiconductor & Display Technology
    • /
    • v.9 no.3
    • /
    • pp.53-58
    • /
    • 2010
  • In this study, we have investigated the effect of the ambient gases on the characteristics of IZO thin films for the OLED (organic light emitting diodes) devices. For this purpose, IZO thin films were deposited by RF magnetron sputtering under various ambient gases (Ar, $Ar+O_2$ and $Ar+H_2$) at $150^{\circ}C$. In order to investigate the influences of the oxygen and hydrogen, the flow rate of oxygen and hydrogen in argon mixing gas has been changed from 0.1sccm to 0.5sccm, respectively. All the samples show amorphous structure regardless of ambient gases. The electrical resistivity of IZO film increased with increasing flow rate of $O_2$ under $Ar+O_2$ while under $Ar+H_2$ atmosphere the electrical resistivity showed minimum value near 0.5sccm of $H_2$. All the films showed the average transmittance over 85% in the visible range. The OLED device was fabricated with different IZO substrates made by configuration of IZO/${\alpha}$-NPD/DPVB/$Alq_3$/LiF/Al to elucidate the performance of IZO substrate. OLED devices with the amorphous-IZO (a-IZO) anode film show better current densityvoltage-luminance characteristics than that of OLED devices with the commercial crystalline-ITO (c-ITO) anode film. It can be explained that very flat surface roughness and high work function of a-IZO anode film lead to more efficient hole injection by reduction of interface barrier height between anode and organic layers. This suggests that a-IZO film is a promising anode materials substituting conventional c-ITO anode in OLED devices.