• 제목/요약/키워드: reduction cleaning

검색결과 229건 처리시간 0.026초

Evaluation of adenosine triphosphate testing for on-farm cleanliness monitoring compared to microbiological testing in an empty pig farrowing unit

  • Yi, Seung-Won;Cho, Ara;Kim, Eunju;Oh, Sang-Ik;Roh, Jae Hee;Jung, Young-Hun;Choe, Changyong;Yoo, Jae Gyu;Do, Yoon Jung
    • Journal of Animal Science and Technology
    • /
    • 제62권5호
    • /
    • pp.682-691
    • /
    • 2020
  • Careful cleaning and disinfection of pigpens is essential to prevent disease spread and avoid the resultant economic losses. Hygiene in pigpens is generally evaluated by visual monitoring supplemented with bacteriological monitoring, which includes counting the total aerobic bacteria (TAB) and/or fecal indicator bacteria (FIB). However, these methods present drawbacks such as time and labor requirements. As adenosine triphosphate (ATP) is ubiquitous in all living organisms including microorganisms, this study aimed to directly compare the results of microbial assessment and ATP quantification, and to suggest possible detailed application methods of the ATP test for hygiene evaluation in pigpens of a farrowing unit. Before and after standard cleaning procedures, samples were collected from the floor corner, floor center, and feeding trough of four pigpens at different time points. No FIB were detected and both the TAB and ATP levels were significantly decreased in the floor center area after cleaning. FIB were continuously detected after cleaning and disinfection of the floor corners, and there was no significant ATP level reduction. The feeding trough did not show any significant difference in these values before and after cleaning, indicating insufficient cleaning of this area. The levels of TAB and ATP after cleaning were significantly correlated and the average ATP value was significantly lower in the absence of FIB than in their presence. In the absence of standard references, a more thorough hygiene management could be achieved evenly by supplementing cleaning or disinfection based on the lowest ATP results obtained at the cleanest test site, which in the present study was the floor center. Overall, these results indicate that the on-farm ATP test can be used to determine the cleanliness status, in addition to visual inspection, as an alternative to laboratory culture-based testing for the presence of microorganisms.

Frictional Characteristics of Woven and Nonwoven Wipes

  • Das A.;Kothari V. K.;Mane D.
    • Fibers and Polymers
    • /
    • 제6권4호
    • /
    • pp.318-321
    • /
    • 2005
  • Demand for the fabric wipes is growing continuously. Wipes in industry are used for cleaning purpose. Cleaning involves rubbing action, so it is very important to know how much frictional force is encountered during the cleaning action. In this study the effects of normal load, sliding speed on frictional characteristics of nonwoven and woven wipes, both dry and wetted with different liquids, against glass and floor tile surfaces have been reported. With the increase in the normal load the coefficient of friction goes on decreasing for both nonwoven and woven wipes and this trend is observed in both dry and wet wipes. The coefficient of friction of both nonwoven and woven wipes against glass surface is in general higher than the floor tile surface. The wipes wetted with water shows an increase in coefficient of friction as compared to dry sample, but there is reduction in the coefficient of friction when the wipe samples are wetted with vegetable oil. In case of dry wipes, the coefficient of friction in case of nonwoven wipe is higher than the woven wipe. In case of woven wipes, the ranges of coefficient of friction either due to change in liquid type, normal load or sliding speed are in general smaller than that in case of nonwoven fabrics.

EUV 세정에서 정전기 제어를 위한 전해이온수 거동의 분자궤도 이해 (Understanding Behaviors of Electrolyzed Water in Terms of Its Molecular Orbitals for Controlling Electrostatic Phenomenon in EUV Cleaning)

  • 김형원;정윤원;최인식;최병선;김재영;유근걸
    • 반도체디스플레이기술학회지
    • /
    • 제21권4호
    • /
    • pp.6-13
    • /
    • 2022
  • The electrostatic phenomenon seriously issued in extreme ultraviolet semiconductor cleaning was studied in junction with molecular dynamic aspect. It was understood that two lone pairs of electrons in water molecule were subtly different each other in molecular orbital symmetry, existed as two states of large energy difference, and became basis for water clustering through hydron bonds. It was deduced that when hydrogen bond formed by lone pair of higher energy state was broken, two types of [H2O]+ and [H2O]- ions would be instantaneously generated, or that lone pair of higher energy state experiencing reactions such as friction with Teflon surface could cause electrostatic generation. It was specifically observed that, in case of electrolyzed cathode water, negative electrostatic charges by electrons were overlapped with negative oxidation reduction potentials without mutual reaction. Therefore, it seemed that negative electrostatic development could be minimized in cathode water by mutual repulsion of electrons and [OH]- ions, which would be providing excellences on extreme ultraviolet cleaning and electrostatic control as well.

De-Ash Characteristics using a Cleaning Agent KOH of CDPF for PM Reduction of Diesel Engines

  • Seo, Choong-Kil
    • 동력기계공학회지
    • /
    • 제20권1호
    • /
    • pp.30-35
    • /
    • 2016
  • The objective of this study is to investigate the physicochemical properties of the catalysts and the feasibility of remanufacturing them after removing ash in CDPF using a cleaning agent KOH. Compared with the carbon oxidation ability of fresh CDPF, that of de-ashed CDPF had an insignificant difference due to the low activation energy of CO and $CO_2$. As ash deposited in CDPF was de-ashed with KOH, it had a practical feasibility on remanufacturing point of view, but washcoat was melted about 26%. Further studies were required for the prevention of washcoat loss.

쓰레기자동집하시설의 악취저감대책에 대한 고찰 (A Study of Odor Reduction Method for Automatic Waste Collection Facilities)

  • 백경일;엄진석;나형용;한인섭
    • 한국유체기계학회 논문집
    • /
    • 제17권2호
    • /
    • pp.54-58
    • /
    • 2014
  • The method of residential waste and food waste collecting is changed into automatic waste collection(AWC) system from direct collection by human resource. To solve the problem caused by odour from AWC facilities, the structure of input facilities, conveying pipes and collecting facilities have been changed into closed and sealed construction to enclosed the facilities and collect odour efficiently. Based on cases and experiences, to treat variable odour matters which are caused by food waste, chemical cleaning method is preferable method to cope with odour caused by food waste.

초음파검사용 젤 용기의 제균을 위한 세척방법 평가 (Evaluation of Washing Method for Sterilization of Gel Container for Ultrasound Inspection)

  • 이희정;이석준;성열훈
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제41권3호
    • /
    • pp.241-247
    • /
    • 2018
  • The purpose of this study was to compare the ultrasound gel container washing methods for the sterilization of contaminants and to find the useful methods for the prevention of infection caused by the ultrasonic gel containers. In this experiment, a 250 mL ultrasonic gel container was used, and the ultrasonic gel used was a non-sterile gel (ECO GEL 99, SeungWon Medical, Korea). In order to evaluate the degree of contamination, new 250 mL 15 containers were divided into 5 groups to perform five types of washing by no treatment, washing with water, washing with soap, washing with bottle cleaner and high disinfection level washing. After the washing process, filled the gel container with gel and after 2 weeks, the number of colonies in the gel container was sampled repeatedly twice in the same ultrasonic laboratory and compared before and after washing. As a result of among the five cleaning methods used in this study, 87.2% and 88.9% of the soapy water washing (p = 0.028) and high level washing (p = 0.027) showed significant bacterial reduction rates, respectively. Our findings conclusively an ultrasonic gel container cleaning method for removing contaminants has been found to be an effective sterilization method at a low cost with a soapy water cleaning method. Therefore, it is expected that it will be helpful to prevent the infection caused by the ultrasonic gel container by suggesting the sterilization cleaning method that is practically useful in this study.

신뢰성 있는 플래시메모리 저장시스템 구축을 위한 플래시메모리 저장 공간 관리 방법 (New Flash Memory Management Method for Reliable Flash Storage Systems)

  • 김한준;이상구
    • 한국정보과학회논문지:시스템및이론
    • /
    • 제27권6호
    • /
    • pp.567-582
    • /
    • 2000
  • 본 논문은 로그파일시스템의 원리를 바탕으로 플래시메모리 저장시스템에 적합한 플래시메모리 공간 관리 방법을 제안한다. 플래시메모리는 비휘발성, 빠른 입출력 속도 등의 장점을 지니고 있지만, 제자리 덮어쓰기(in-place update)가 불가능하고 메모리 셀에 대한 쓰기(write) 횟수가 제한되는 단점이 있다. 이러한 특성은 플래시메모리를 저장 매체로 사용할 때 기존의 저장 매체 관리 방법과는 다른 방법을 요구하게 된다. 본 논문은 자유 공간유지를 위해 필요한 클리닝 메커니즘의 연산 비용을 낮추면서 동시에 저장공간이 전체적으로 균등하게 사용될 수 있도록 하는 사이클 평준화 기법을 제안한다. 제안된 방법은 특히 메모리 활용도와 로컬리티가 높을 때 좋은 성능을 보인다. 클리닝 메커니즘은 자주 접근되지 않는 COLD데이타를 그렇지 않은 데이타와 격리시킴으로써 그 효율이 향상되었으며, 사이클 평준화는 사용 횟수간의 최대 차이가 하드웨어적인 오차를 벗어나지 않는 수준까지 이루었다. 실험을 통해 제안된 방법은 비교 기준으로 삼은 직관적 방법(greedy policy)에 비해 사이클 평준화가 잘 이루어진 상태에서 최대 35%정도의 클리닝 비용 절감 효과를 보였다.

  • PDF

Removal of Organic Wax and Particles on Final Polished Wafer by Ozonated DI Water

  • Yi, Jae-Hwan;Lee, Seung-Ho;Kim, Tae-Gon;Lee, Gun-Ho;Choi, Eun-Suck;Park, Jin-Goo
    • 한국재료학회지
    • /
    • 제18권6호
    • /
    • pp.307-312
    • /
    • 2008
  • In this study, a new cleaning process with a low cost of ownership (CoO) was developed with ozonated DI water ($DIO_3$). An ozone concentration of 40 ppm at room temperature was used to remove organic wax film and particles. Wax residues thicker than $200\;{\AA}$ remained after only a commercial dewaxer treatment. A $DIO_3$ treatment in place of a dewaxer showed a low removal rate on a thick wax layer of $8000\;{\AA}$ due to the diffusion-limited reaction of ozone. A dewaxer was combined with a $DIO_3$ rinse to reduce the wax removal time and remove wax residue completely. Replacing DI rinse with the $DIO_3$ rinse resulted in a surface with a contact angle of less than $5^{\circ}$, which indicates no further cleaning steps would be required. The particle removal efficiency (PRE) was further improved by combining a SC-1 cleaning step with the $DIO_3$ rinsing process. A reduction in the process time was obtained by introducing $DIO_3$ cleaning with a dewaxing process.

전해 양극수를 이용한 디스플레이 신 세정 공정 (A new cleaning concept for display process with electrolyzed anode water)

  • 최민기;차지영;김영근;류근걸
    • 한국산학기술학회:학술대회논문집
    • /
    • 한국산학기술학회 2004년도 추계학술대회
    • /
    • pp.99-102
    • /
    • 2004
  • Display process has adopted RCA clean, being applied to large area and coped with environmental issue for last ten years. However, the approaching concept of ozonized, hydrogenised, or electrolyzed water cleaning technologies is within RCA clean paradigm. In this work, only electrolyzed anode water was applied to clean particles and organics as well as metals based on Pourbaix concept, and as a test vehicle, MgO particles were introduced to prove the new concept. The electrolyzed anode water is very oxidative with high oxidation reduction potential(ORP) and low in pH of more than 900mV and 3.1, respectively. MgO particles were immerged in the anode water and its weight losses due to dissolution were measured with time. Weight losses were in the ranges of 100 to 500 micrograms in 250m1 anode waters depending on their ORP and pH. Therefore it was concluded that the cleaning radicals in the anode water was at least in the range of 1 to 5E20 ea per 250 ml anode water equivalent to IE18 ea/cm3. Hence it can be assumed that the anode water be applied to display cleaning since 1E10 to IE15 ea/cm3 ranges of contaminants are being treated. In addition, it was observed that anode water does not develop micro-roughness on hydrophobic surface while it does on the native silicon oxide.

  • PDF

Microbiological cleaning and disinfection efficacy of a three-stage ultrasonic processing protocol for CAD-CAM implant abutments

  • Gehrke, Peter;Riebe, Oliver;Fischer, Carsten;Weinhold, Octavio;Dhom, Gunter;Sader, Robert;Weigl, Paul
    • The Journal of Advanced Prosthodontics
    • /
    • 제14권5호
    • /
    • pp.273-284
    • /
    • 2022
  • PURPOSE. Computer-aided design and manufacturing (CAD-CAM) of implant abutments has been shown to result in surface contamination from site-specific milling and fabrication processes. If not removed, these contaminants can have a potentially adverse effect and may trigger inflammatory responses of the peri-implant tissues. The aim of the present study was to evaluate the bacterial disinfection and cleaning efficacy of ultrasonic reprocessing in approved disinfectants to reduce the microbial load of CAD-CAM abutments. MATERIALS AND METHODS. Four different types of custom implant abutments (total N = 32) with eight specimens in each test group (type I to IV) were CAD-CAM manufactured. In two separate contamination experiments, specimens were contaminated with heparinized sheep blood alone and with heparinized sheep blood and the test bacterium Enterococcus faecium. Abutments in the test group were processed according to a three-stage ultrasonic protocol and assessed qualitatively and quantitatively by determination of residual protein. Ultrasonicated specimens contaminated with sheep blood and E. faecium were additionally eluted and the dilutions were incubated on agar plates for seven days. The determined bacterial counts were expressed as colony-forming units (CFU). RESULTS. Ultrasonic reprocessing resulted in a substantial decrease in residual bacterial protein to less than 80 ㎍ and a reduction in microbiota of more than 7 log levels of CFU for all abutment types, exceeding the effect required for disinfection. CONCLUSION. A three-stage ultrasonic cleaning and disinfection protocol results in effective bacterial decontamination. The procedure is reproducible and complies with the standardized reprocessing and disinfection specifications for one- or two-piece CAD-CAM implant abutments.