• 제목/요약/키워드: reducing radiation of exposure

검색결과 142건 처리시간 0.029초

Glass Dosimeter를 이용한 환자피폭선량에 관한 분석 (Analysis of Patient Exposure dose with Glass Dosimeter)

  • 김재인;최원근;장성원;오창섭;이관섭;하동윤
    • 대한디지털의료영상학회논문지
    • /
    • 제11권1호
    • /
    • pp.15-20
    • /
    • 2009
  • Far reducing medical radiation exposure and managing patient doses, Entrance surface doses(ESDs) were measured at Diagnostic Radiology Department in ASAN medical center, also we determined and compared with the Diagnostic Reference Level(DRL) of some other countries. ESDs were measured far the most common types of X-ray procedures, such as chest PA, lumbar spine AP, lumbar spine lateral, Pelvis AP, Skull PA. ESDs were measured by Glass dosimeter and Unfors Xi meter. Those were applied collimation center of phantom's entrance skin surface. The results of ESDs were compared Glass dosimeter with Unfors Xi meter. Those were measured within 5% statistical difference. It seemed well agreement at two devices. In most cases ESDs measured far the different types of X ray procedures were found to be lower than the DRL of IAEA, but ESDs on chest PA, lumbar spine AP, lumbar spine lateral, Pelvis AP, Skull PA were proximity ar excesses at DRL of advanced country. Through this study, we need an investigation and improvement at present diagnostic radiology exam system. Also, radiologists make an effort to reduce patient dose and having a technical skill.

  • PDF

Phantom을 이용한 뇌 관류 CT검사에서 방사선 피폭선량에 관한 연구 (A Study on the Radiation Exposure Dose of Brain Perfusion CT Examination a Phantom)

  • 정홍량;김기정;모은희
    • 한국융합학회논문지
    • /
    • 제6권5호
    • /
    • pp.287-294
    • /
    • 2015
  • 본 연구의 목적은 급성기 허혈성 뇌졸중 환자의 뇌 관류 CT검사 시 피폭선량을 알아보고자 하였다. 특히, 방사선 감수성이 높은 장기들의 장기선량(Organ dose)을 팬텀과 유리선량계를 이용하여 실측해보고, 제조사가 제시한 기존 프로토콜(고정시간기법)과 새로 제시한 융합 프로토콜(조영제 추적기법)을 적용하여 선량을 측정하여 보고, 피폭선량 저감화 방안을 마련하고자 하였다. 분석결과 기존 프로토콜과 비교하여 새로 제시한 융합 프로토콜에서 최고 39.8 %, 최저 5.8 % 장기선량이 감소하였고, 검사 피폭선량인 $CDTI_{vol}$과 DLP 값은 각각 25 % 감소하였으며, 권고 선량 이하로 측정되었다. 위의 분석결과를 바탕으로 기존에 제시된 프로토콜을 점검해보고, 새로 제시한 융합 프로토콜을 적용하여 피폭선량을 감소시켜 국민보건향상에 이바지 해야 할 것이며, 다른 검사에서도 최적의 프로토콜을 찾기 위한 연구가 계속되어져야 할 것으로 사료된다.

유방 촬영검사에서 사전조사 관전압과 실제조사 관전압 편차에 따른 원인 분석 (Analysis of the cause by Pre Exposure Tube Voltage and Actual Exposure Tube Voltage deviation in Mammography Examination)

  • 조지환;이효영;임인철
    • 한국방사선학회논문지
    • /
    • 제11권2호
    • /
    • pp.79-85
    • /
    • 2017
  • 본 연구에서는 유방촬영검사에서 사전조사 관전압과 실제조사 관전압 편차에 따른 원인분석을 유방압박두께, 유방크기, 체질량지수와 연관하여 규명하고 개선책을 찾고자 하였다. 국민건강보험공단에서 실시하는 유방촬영 검진자 중 40세 이상 여자 377명을 대상으로 조사하였다. 유방촬영검사에서 상하방향촬영에 의한 영상을 참고하여 의료영상저장정보시스템으로 전송되어진 선량 보고서(dose report)의 파라메타 중 사전조사 관전압과 실제조사 관전압의 편차에 따른 유방압박두께, 유방크기, 체질량지수를 분석하였다. 결과로는 유방압박두께가 얇을수록, 유방크기가 작을수록, 체질량지수가 작을수록 관전압 편차가 크게 나타났다. 결론적으로 유방촬영검사에서 유방압박두께와 유방크기에 따른 관전압 설정을 하기 위해 우리나라 실정에 맞는 유방촬영기기의 최소 관전압이 재설정 되어야 할 것이며, 또한 유방압박두께가 얇은 환자나 유방크기가 작은 환자를 검사할 경우 정확한 조사조건 매뉴얼을 만들어 검사함으로서 촬영조건의 편차를 줄여 방사선피폭 경감과 좋은 영상의 화질을 만드는데 노력해야 할 것으로 사료된다.

이동형 전산화단층촬영장치의 기본 안전 및 필수 성능 기준을 마련하기 위한 연구 (A Study on Establishment of Basic Safety and Essential Performance Criteria of Mobile Computed Tomography)

  • 김은혜;박혜민;김정민
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제44권3호
    • /
    • pp.261-267
    • /
    • 2021
  • As the number of Coronavirus Disease-19 (COVID-19) patients increases in a global pandemic situation, the usefulness of mobile computed tomography (CT) is gaining attention. Currently, mobile CT follows the basic safety and essential performance evaluation criteria of whole-body or limited-view X-ray CT in order to obtain device approval and evaluation in the Republic of Korea. Unlike stationary CT, mobile CT is not operated in shielded areas but rather areas such as intensive care units, operating rooms, or isolation rooms. Therefore, it requires a different basic safety and essential performance evaluation standard than stationary CT. In this study, four derived basic safety evaluation criteria related to electrical, mechanical, and radiation safety were included (dose indication test, protection against stray radiation, safety measures against excessive X-rays, half-value layer measurement); and seven essential performance evaluation criteria were included (tube voltage accuracy, mAs accuracy, radiation dose reproducibility, CT number of water, noise, uniformity, and spatial resolution); total eleven basic safety and essential performance evaluation criteria were selected. This study aims to establish appropriate basic safety and essential performance evaluation criteria for simultaneously obtaining images with diagnostic value and reducing the exposure of nearby patients, medical staff, and radiologic technologists during the use of mobile CT.

Development of Ready-to-Eat Bulgogi Sauce with No Change of Sensory Properties after High-Dose Irradiation

  • Shin, Mee-Hye;Park, Jin-Gyu;Kim, Cheon-Jei;Lee, Ju-Woon
    • 한국축산식품학회지
    • /
    • 제31권3호
    • /
    • pp.366-371
    • /
    • 2011
  • Viscosity is critically important for bulgogi sauce. However, exposure to irradiation may decrease the rheological properties of bulgogi sauce. This study was conducted to compare the effects of gamma irradiation (0-9 kGy) on viscosity, molecular weight, pH, reducing end level, and water solubility of xanthan gum, guar gum, and locust bean gum as thickening agents/stabilizers in bulgogi sauce. The physicochemical properties of all samples changed (p<0.05) from 3965 to 0 cP (viscosity), from 6048 to 28 kDa (molecular weight), from 5.79 to 4.62 (pH), from 0.13 mg/mL to 1.72 mg/mL (reducing end level), and from 6% to 87% (water solubility) following gamma irradiation. Viscosity after irradiation was most stable (p<0.05) in xanthan gum (from 1249 to 92 cP) compared with guar gum (from 3965 to 0 cP) and locust bean gum (from 1631 to 0 cP). The sensory properties (texture and taste) of bulgogi sauce prepared with xanthan gum (1%, w/w) were highly maintained (about 7.0-5.0) after high-dose irradiation of up to 40 kGy. These results indicate that xanthan gum can be effectively used as a thickening agent/stabilizer in bulgogi sauce, which had low viscosity after irradiation.

Sensitivity Analysis on the Priority Order of the Radiological Worker Allocation Model using Goal Programming

  • Jung, Hai-Yong;Lee, Kun-Jai
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1998년도 춘계학술발표회논문집(2)
    • /
    • pp.577-582
    • /
    • 1998
  • In nuclear power plant, it has been the important object to reduce the occupational radiation exposure (ORE). Recently, the optimization concept of management science has been studied to reduce the ORE in nuclear power plant. In optimization of the worker allocation, the collective dose, working time, individual dose, an total number of worker must be considered and their priority orders must be thought because the main constraint is necessary for determining the constraints variable of the radiological worker allocation problem. The ultimate object of this study s to look into the change of the optimal allocation of the radiological worker as priority order changes. In this study, the priority order is the characteristic of goal programming that is a kind of multi-objective linear programming. From a result of study using goal programming, the total number of worker and collective dose of worker have changed as the priority order has changed and the collective dose limit have played an important role in reducing the ORE.

  • PDF

Development of Ceramic Humidity Sensor for the Korean Next Generation Reactor

  • Lee, Na-Young;Hwang, Il-Soon;Yoo, Han-Ill;Song, Chang-Rock
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1996년도 추계학술발표회논문집(1)
    • /
    • pp.183-190
    • /
    • 1996
  • Leak-before-break(LBB) approach has been shown to be both cost and risk effective by reducing maintenance cost and occupational exposure when applied to high energy piping in nuclear power plants. For Korean Next Generation Reactor(KNGR) development, LBB is considered for the Main Steam Line(MSL) piping inside containment. Unlike the reactor coolant piping leakages which can be detected by particulate and gaseous radiation monitoring, main steam line leak detection systems must be based on principles that do not involve radioactivity. Ceramics are widely used as humidity sensor materials which can be further developed for nuclear applications. In this paper, we describe the progress in the development of ceramic humidity sensors for use with the main steam lines of KNGR.

  • PDF

Bolus tracking 기법을 이용한 복부 CT 검사 시 조영제 도달시간에 따른 환자 피폭선량 감소에 관한 연구 (A Study on the Reduction of Patient's Exposure Dose according to the Arrival Time of Contrast Media in Abdominal CT Scan using Bolus Tracking Technique)

  • 이승용;한동균
    • 한국방사선학회논문지
    • /
    • 제15권2호
    • /
    • pp.93-100
    • /
    • 2021
  • 본 연구는 bolus tracking 기법을 이용한 복부 CT 검사 시 환자 피폭선량에 영향을 미치는 인자를 알아보고 인자를 통해 지연시간을 조절하여 추후 bolus tracking 기법을 이용한 복부 CT 검사 시 환자의 방사선 피폭선량을 감소시키는 목적이 있다. 실험은 두 가지로 나누어 실시하였고, 첫 번째 실험은 환자 300명을 대상으로 하였고 남자 188명, 여자 112명, 평균나이는 58±12.18세(19~85세)이었다. 대상자의 신장, 체중, 체질량지수, 수축기혈압, 이완기혈압, 심박동수에 따른 조영제 도달시간(Arrival time)을 측정하였고, 영향 인자 그룹별 도달시간의 평균값을 기준으로 영향 인자에 따른 지연시간을 정하여 두 번째 실험에 적용하였다. 두 번째 실험은 첫 번째 실험 대상자 중 추적검사를 시행하는 150명(남자 100명, 여자 50명)을 대상으로하였고, 영향 인자에 따른 지연시간을 적용하여 적용 전·후 선량을 비교하였다. 첫 번째 실험 결과 조영제 도달시간과 심박동수가 관계가 있었고, 두 번째 실험 결과 심박동수에 따른 지연시간 적용 전·후 CTDIvol와 DLP 의 평균선량은 남자 4.98 mGy, 5.33 mGy·cm 감소하였고, 여자 3.53 mGy, 3.88 mGy·cm 감소하였다. 따라서 bolus tracking 기법을 이용한 복부 CT 검사 시 환자의 심박동수에 따른 지연시간 적용으로 방사선 피폭선량을 감소시킬 수 있다.

MLO View의 유방촬영에서 QC 프로그램을 이용한 선량 및 영상 평가 (Evaluation of Radiation Dose and Imaging of the QC Program in Mammography MLO View)

  • 이선화;김정민;권대철
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제38권3호
    • /
    • pp.221-228
    • /
    • 2015
  • 목적: 디지털 유방촬영에서 QC 프로그램을 이용하여 방사선 피폭 선량의 감소와 고화질의 영상을 목적으로 하였다. 재료 및 방법: 디지털 유방촬영술에서 QC phantom을 사용하여 노출 방식에 따른 평균유선선량을 MLO view에서 $0^{\circ}C$, $30^{\circ}C$, $45^{\circ}C$, $50^{\circ}C$, $55^{\circ}C$, $70^{\circ}C$, $90^{\circ}C$ 구간에서 측정하였고, Hologic사의 QC 프로그램으로 영상에서 SNR과 CNR을 측정하여 평가하였다. 결과: 평균유선선량은 $90^{\circ}C$ 일 때 1.75 mGy로 최대치였고, $45^{\circ}C$에서 약 6 % 감소한 1.65 mGy 측정되었다. 또한 auto filter에서 1.67 mGy, manual에서는 1.52 mGy의 평균유선선량을 기록하여 노출 방식에 따라 선량이 차이가 있었다. 화질평가의 모든 각도 구간에서 SNR 50~52, CNR 11~12로 근소한 차이를 나타내고, 제조사의 권고치 내에 포함되었다. 결론: MLO view $45^{\circ}C$에서 가장 적은 선량이었고, SNR 및 CNR의 차이는 미미하였다. 이때의 노출방식은 환자의 체형이나 특성을 고려한 설정으로 차이를 두어 불필요한 환자의 피폭 선량을 줄이기 위한 방법이 필요하다.

방사선 누설선량 조사를 통한 방어시설과 누설선량 평가방법에 대한 문제점 연구 : 부산, 경남 지역 CT실을 중심으로 (Indicating the Problem of Shielding Design and the Way of Estimating Radiation Leakage for CT Rooms located through Survey of Radiation Leakage : in the case of Busan and Gyung-nam Area)

  • 양원석;최준혁;신운재;민병인
    • 한국콘텐츠학회논문지
    • /
    • 제13권11호
    • /
    • pp.768-777
    • /
    • 2013
  • 이 연구는 CT(computed tomography)검사 중 발생하는 방사선 누설선량(radiation leakage)으로부터 종사자 및 일반인의 피폭을 최소화하기 위한 것이다. 부산, 경남에 위치한 대학병원 7곳과 종합전문요양병원 4곳의 CT실을 대상으로 하였다. 누설선량 측정 장소로는 1) 조정실 내 감시창 벽면의 지면으로부터 3m 높이 2) 조정실 내 특정 지점 3) 조정실 내 종사자 출입문 4) 환자 출입문을 선정하였다. 그 결과 M병원의 종사자 출입문에서 가장 높은 누설선량이 나타났다. 각각의 측정값은 고전적 방법에 의한 주당 최대 누설선량으로 환산하였다. 그 결과 1) $5.97{\pm}0.23$, 2) $0.50{\pm}0.02$, 3) $10.00{\pm}0.11$, 4) $2.37{\pm}0.47$ mR/week로 주당 최대 누설선량 허용치(<100 mR/week)이하였다. 하지만 측정 최대 누설선량을 기록한 M병원의 조정실 내 종사자 출입문을 실험적 방법으로 계산한 결과 $118.31{\pm}17.72$ mR/week(>100 mR/week)로 나타났다. 조정실 지면으로부터 3 m 이상의 높이에서의 누설선량은 조정실내부에 영향을 끼쳤다(p<0.05). 따라서, 누설선량의 피해를 줄이기 위해, 주당 최대 누설선량 산출 방법에 대한 개선과, 조정실 차폐벽의 차폐체를 3 m 이상으로 할 것을 제안 한다.