A Comparative Study of CTDI and the Effective Dose and the SNR according to the Area in the Abdominal CT (복부CT에서 면적에 따른 CTDI와 유효선량 및 SNR의 비교 연구)

  • Choi, Sung-Jun;Kang, Jun-Guk;Kim, Su-In;Kim, Youn-Ho;Lee, Do-Gyeong;Jung, Jin-Gyung;Cho, Ar-A;Jang, Jae-Hyeok;Kweon, Dae-Cheol
    • Journal of radiological science and technology
    • /
    • v.38 no.3
    • /
    • pp.245-252
    • /
    • 2015
  • To obtain the best SNR (signal to noise ratio) due to changes in CTDI (computed tomography dose index) made for the purpose of setting the optimum image obtained by reducing the dose in abdominal CT. Abdominal CT scans of 59 patients a $400-499cm^2$ (n = 12), $500-599cm^2$ (n = 21), $600-699cm^2$ (n = 17), $700-799cm^2$ (n = 9) were separated by four groups and the effective dose was used in the Excel to get the area of the patient using the ImageJ program. Patients of CTDI, DLP, SNR, the effective dose were analyzed. Abdominal CT area was increased to 13 mGy in CTDI is 7.3 mGy, DLP to 732 in $394.4mGy{\cdot}cm$, also effective dose was 5.9 mSv increase in 11mSv. SNR is 15 dB was maintained at 12.7. CTDI according to the average of the abdominal area of 8.9 mGy, the average of the DLP was $481.54mGy{\cdot}cm$, the effective dose is calculated to be 7.2 mSV. Effective dose was calculated by multiplying the load factor of DLP in the abdomen showed no statistically significant difference of (p < .05), there was a significant difference in SNR (p > . 05). To improve image quality of abdominal CT scan image in consideration of the CTDI according to the volume of the patient it should be able to reduce the radiation exposure of the patients.

Study on Optimized Dispensing of F-18 FDG Auto Dispenser (F-18 FDG 자동분주기의 분주 최적화에 관한 연구)

  • Ji, Bong-Geun;Lee, Sang-Hun;Kim, Jong-Eon;Kim, Won-Tae;Ji, Tae-Jeong
    • Journal of radiological science and technology
    • /
    • v.39 no.3
    • /
    • pp.377-384
    • /
    • 2016
  • This is a study on the optimized dispensing of the auto dispenser used for the purpose of reducing the exposure dose and accurate radiation dose of radioisotope with regard to the PET/CT practitioners. The research method was to find the optimized dispensing method through evaluating the results according to the syringe type, dispensing rate, and vial pressure and through the application of corrected values. As a result of this study, 9.38 mCi has been dispensed on average in the case of 5 ml syringe, and the reproducibility close to 10 mCi was shown at the dispense of 9.55 mCi in the case of 3 ml syringe. In the evaluation according to the dispensing rate, the quantity of radioisotope close to 10 mCi was dispensed at the rate of 5 mm/min when the measurement was carried out by increasing the rate by 5 mm/min units in the order of 5, 10, 15 and 20 mm/min. In the evaluation result according to the vial pressure before/after the use of Needle filter, it was measured to be 9.53 mCi before use and 9.84 mCi after use confirming that the dispensing after using Needle filter showed the optimal value. In addition, in the evaluation of radioactivity before/after the application of corrected values according to the increase in dispense frequency, it was measured 9.53 mCi before correction and 10.07 mCi after correction confirming that the value with correction applied was closer to the quantitative value. Thus, a good optimized method was confirmed to use a 3 ml syringe with dispensing rate of 5 mm/min, to use a Needle filter at dispensing, and to set the corrected value of [$y=0.097{\times}x$] according to the dispensing frequency of equipment.