• 제목/요약/키워드: reduced model

검색결과 6,473건 처리시간 0.034초

풍력발전기 축소 구조 모델의 진동특성 연구 (A Study on the Vibration Characteristics of the Reduced Structure Model of Wind Turbine Generator)

  • 박무열;은성용;김석현
    • 산업기술연구
    • /
    • 제24권B호
    • /
    • pp.83-87
    • /
    • 2004
  • A reduced structure model of a wind turbine generator is designed and manufactured. Mode data are obtained by modal testing and analytical method. Vibration response is measured and investigated under various speed condition by using a waterfall plot. Possibility of severe resonance is observed and the mechanism is explained by using the mode data. Simplified theoretical model gives the 1st resonance frequency of wind turbine structure model. The theoretical model can be applied in the design stage of the wind turbine structure to avoid the severe resonance problem.

  • PDF

축소 화학반응 모델링에 의한 탄화수소 연료의 점화지연 특성 (Characteristics of the Ignition Delay for Hydrocarbon Fuels by Reduced Chemical Kinetics Modeling)

  • 김형욱;배상수;민경덕
    • 한국자동차공학회논문집
    • /
    • 제9권4호
    • /
    • pp.44-49
    • /
    • 2001
  • Reduced chemical kinetics mechanism has been derived, which can be applicable for autoignition model of hydrocarbon fuels, and contains 23 reactions and 18 species. The present model is validated with the experimental data, where the ignition delays of several hydrocarbon fuels, such as n-heptane, i-octane, n-decane and DME(dimethylether) are measured as equivalence ratios are varied. Especially, the effects of different fuels on ignition delays can be explained by changing the rate constants of three reactions among the present model. As a result, the proposed model can be applicable to two stage ignition model of Diesel combustion.

  • PDF

모형실험에 의한 수평보강재로 보강된 터널 막장의 거동 분석 (Investigation on the Behavior of Tunnel Face Reinforced with Longitudinal Reinforcements using Reduced-Scale Model Tests)

  • 유충식;신현강
    • 한국터널지하공간학회 논문집
    • /
    • 제2권2호
    • /
    • pp.32-40
    • /
    • 2000
  • 본 논문에서는 수평보강재로 보강된 터널 막장의 거동에 대한 매개변수 연구를 다루었다. 매개변수 연구에서는 축소모형실험을 수행하였으며 실험 결과를 이용하여 보강막장의 거동을 고찰하였다. 실험결과 터널 막장은 수평보강재로 보강함에 따라 변형이 억제되어 안정성이 증대되는 경향을 보였으며, 이러한 결과는 3차원 유한요소해석 결과와 정성적인 면에서 좋은 일치를 보였다. 따라서 막장 수평보강 공법은 막장의 안정성을 향상시키는 매우 유용한 공법으로 적용될 수 있을 것으로 판단되며, 일반적인 설계법을 개발하기 위해서 3차원 유한요소해석 모델링이 활용될 수 있을 것으로 사료된다.

  • PDF

여성의 개인적 특성과 생활양식요인을 이용한 골량감소 예측모형 (Prediction Model for Reduced Bone mass in Women using Individual Characteristics & Life Style Factors)

  • 이은남;이은옥
    • 근관절건강학회지
    • /
    • 제5권1호
    • /
    • pp.83-109
    • /
    • 1998
  • This study was carried out to identify the Important modifiable risk factors for reduced bone mass and to construct prediction model which can classify women with either low or high bone mass. Through the literature review, individual characteristics such as age, body weight, height, education level, family history, age of menarche, postmenopausal period, gravity, parity, menopausal status, and breast feeding period were identified and factors of life style such as past milk consumption, past physical activity, present daily activity, present calcium intake, alcohol intake, cigarette smoking, coffee consumption were identified as influencing factors of reduced bone mass in women. Four hundred and eighty women aged between 28 and 76 who had given measurement bone mineral density by dual energy x-ray absortiometry in lumbar vertebrae and femur from July to October, 1997 at 4 general hospitals in Seoul and Pusan were selected for this study. Women were excluded if they had a history of any chronic illness such as rheumatoid arthritis, diabetes mellitus, hyperthroidism, & gastrointestinal disorder and any medication such as calcium supplements, calcitonin, estrogen, thyroxine, antacids, & corticosteroids known affect bone. As a result of these exclusion criteria, four hundred and seventeen women were used for analysis. Multiple logistic regression model was developed for estimating the likelihood of the presence or absence of reduced bone mass. A SAS procedure was used to estimate risk factor coefficient. The results are as follows For lumbar spine, the variables significant were age, body weight, menopause status, daily activity, past milk consumption, and past physical activity(p<0.01), while for femoral Ward's triangle, age, body weight, level of education, past milk consumption, past physical activity(p<0.001). Past physical activity, present daily activity and past milk consumption are the most powerful modifiable predictors in vertebrae and femur among the predictors. When the model performance was evaluated by comparing the observed outcome with predicted outcome, the model correctly identified 74.1% of persons with reduced bone mass and 84.5% of persons with normal bone mass in the lumbar vertebrae and 82.9% of persons with reduced bone mass and 75.0% of persons with normal bone mass in the femoral Ward's triangle. On the basis of these results, a number of recommendations for the management of reduced bone mass may be made : First, those woman who are classified as high risk group of the reduced bone mass in the prediction model should examine the bone mineral density to further examine the usefulness of this model. Second, the optimal amount of milk consumption and a regular weight bearing exercise in childhood, adolescence, and early adult should be ensured.

  • PDF

Incorporating Performance Degradation in Fault Tolerant Control System Design with Multiple Actuator Failures

  • Zhang, Youmin;Jiang, Jin;Theilliol, Didier
    • International Journal of Control, Automation, and Systems
    • /
    • 제6권3호
    • /
    • pp.327-338
    • /
    • 2008
  • A fault tolerant control system design technique has been proposed and analyzed for managing performance degradation in the presence of multiple faults in actuators. The method is based on a control structure with a model reference reconfigurable control design in an inner loop and command input adjustment in an outer loop. The reduced dynamic performance requirements in the presence of different actuator faults are accounted for through different performance reduced (degraded) reference models. The degraded steady-state performances are governed by the reduced levels of command input. The reconfigurable controller is designed on-line automatically in an explicit model reference control framework so that the dynamics of the closed-loop system follow that of the performance reduced reference model under each fault condition. The reduced command input level is determined to prevent potential actuator saturation. The proposed method has been evaluated and analyzed using an aircraft example against actuator faults subject to constraints on the magnitude and slew-rate of actuators.

모델을 이용한 증류공정의 최적화 방안 (A model based scheme of on-line optimization in distillation process)

  • 김흥식;이광순
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1990년도 한국자동제어학술회의논문집(국내학술편); KOEX, Seoul; 26-27 Oct. 1990
    • /
    • pp.240-245
    • /
    • 1990
  • A on-line optimization scheme based on model in a binary distillation process is proposed. A reduced-order model utilized the concept of collocation is used as a process model and the recursive prediction error method is employed to identify the reduced-order model. The concentrations of end products are controlled by nonlinear adaptive predictive control algorithm. The objective function is constructed to find optimum operate condition for saving utility cost. The proposed optimization is scheme is tested through simulation studies in 13-staged water-methanol distillation column.

  • PDF

The Lower Flash Points of the n-Butanol+n-Decane System

  • Dong-Myeong Ha;Yong-Chan Choi;Sung-Jin Lee
    • 한국화재소방학회논문지
    • /
    • 제17권2호
    • /
    • pp.50-55
    • /
    • 2003
  • The lower flash points for the binary system, n-butanol+n-decane, were measured by Pensky-Martens closed cup tester. The experimental results showed the minimum in the flash point versus composition curve. The experimental data were compared with the values calculated by the reduced model under an ideal solution assumption and the flash point-prediction models based on the Van Laar and Wilson equations. The predictive curve based upon the reduced model deviated form the experimental data for this system. The experimental results were in good agreement with the predictive curves, which use the Van Laar and Wilson equations to estimate activity coefficients. However, the predictive curve of the flash point prediction model based on the Willson equation described the experimentally-derived data more effectively than that of the flash point prediction model based on the Van Laar equation.

비선형계를 위한 퍼지모델 기반 감소차수 미지입력관측자 설계 (Design of a Fuzzy Model Based Reduced Order Unknown Input Observer for a Class of Nonlinear Systems)

  • 이기상
    • 전기학회논문지
    • /
    • 제57권7호
    • /
    • pp.1247-1253
    • /
    • 2008
  • A design method of a T-S fuzzy model based reduced order nonlinear unknown input observer(NUIO) is presented. The fuzzy NUIO is designed based on the parallel distributed compensation(PDC) concept. It consists of a number of the linear UIOs, each of which is designed for each local linear model in the T-S fuzzy model of a class of nonlinear systems. The fuzzy NUIO provides not only the state estimates insensitive to the unknown inputs, for example, disturbances and faults etc., but also the estimates of the unknown inputs. Therefore, It can be employed in the state feedback control and disturbance rejection control of a class of nonlinear systems with unknown disturbances. It also applied to the robust residual generation for the fault detection and isolation systems and to the design of fault tolerant control systems. As an example, the NUIO is applied to an inverted pendulum system to show the state and disturbance estimation performance and to illustrate the fuzzy reduced order NUIO design method.

전차선로 시스템의 등가 축약 모델 (A Reduced Equivalent model of the Catenary System)

  • 이한민;오광해;이장무;한문섭;창상훈
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2003년도 춘계학술대회 논문집
    • /
    • pp.415-420
    • /
    • 2003
  • This paper estimates line constants of equivalent five-conductors model by using the reduced equivalent method. Actually, the catenary system is considered by the equivalent five-conductors model in the electrical aspect. Therefore, we should compose the catenary system of the equivalent five-conductors model. And then we calculate line constants of this equivalent five-conductors model. This paper shows the reducing process about the real system of the field by using the proposed theory and also line constants of reduced system

  • PDF

능동형 제진 시스템의 설계 및 해석 (Design and Analysis of an Active Vibration Isolation System)

  • 문준희;박희재
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 추계학술대회논문집
    • /
    • pp.647-650
    • /
    • 2004
  • The modeling of an active vibration isolation system is accomplished by using the equivalent spring constant, mass and rotational Inertia of each component. The detailed model of the actuation module is successful for describing its frequency-domain performance but also too complicated to implement it to actual system for control so that the order of the model is reduced up to the degree that preserves its characteristic in the low frequency range. The reduced model is suitable for identifying the unknown system parameters such as damping constants of components. The overall isolation system is described by using the reduced model of the actuation module. The accurate model ing and system parameter identification that is essential for the control of the active vibration isolation system is attained successfully.

  • PDF