• Title/Summary/Keyword: reduced eye

Search Result 220, Processing Time 0.029 seconds

MiR-199a/b-5p Inhibits Lymphangiogenesis by Targeting Discoidin Domain Receptor 1 in Corneal Injury

  • Oh, Sooeun;Seo, Minkoo;Choi, Jun-Sub;Joo, Choun-Ki;Lee, Suk Kyeong
    • Molecules and Cells
    • /
    • v.41 no.2
    • /
    • pp.93-102
    • /
    • 2018
  • Discoidin domain receptor 1 (DDR1) is involved in tumorigenesis and angiogenesis. However, its role in lymphangiogenesis has been unknown. Here, we tested whether downregulation of DDR1 expression by miR-199a/b can suppress lymphangiogenesis. We also aimed to identify miRNA target site(s) in the 3' untranslated region (UTR) of DDR1. Transfection with miR-199a/b-5p mimics reduced expression of DDR1 and tube formation in primary human dermal lymphatic endothelial cells, whereas miR-199a/b-5p inhibitors showed the opposite effects. Critically, injection of miR-199a/b-5p mimics suppressed DDR1 expression and lymphangiogenesis in a corneal alkali-burn rat model. The three well-conserved seed matched sites for miR-199a/b-5p in the DDR1 3'-UTR were targeted, and miRNA binding to at least two sites was required for DDR1 inhibition. Our data suggest that DDR1 promotes enhanced lymphangiogenesis during eye injury, and miR-199a/b-5p suppresses this activity by inhibiting DDR1 expression. Thus, this miRNA may be useful for the treatment of lymphangiogenesis-related eye diseases.

A Study on the Plane Spatial Characteristics of Modern Samurai Houses in Izumi Fumoto Village, Kagoshima, Japan (일본 가고시마 이즈미 후모토 마을의 근세 무사주택의 평면공간특성에 관한 연구)

  • Kim, Yun-Sang
    • Journal of the Architectural Institute of Korea Planning & Design
    • /
    • v.34 no.5
    • /
    • pp.29-38
    • /
    • 2018
  • This study aims to analyze the spatial characteristics of a group of samurai residences among other traditional Japanese villages and to accumulate the village-level sample data of a residential group, which can serve as the foundation for a wide range of discussions. Using data that had been gathered since 1989, this study draw up a prototype floor plans to analyze the indoor spatial features of the residences in the modern period, and sampled 35 samurai houses. The following are the results of this study. The general characteristics of traditional Japanese houses were found among many Izumi Fumoto samurai residences up until the early Meiji period. However, after gradually the floor plan became more and more simplified; connections between rooms were reduced, decreasing their flexibility; and there was a rise in the number of houses with a larger area devoted to the Nando, a room for women and family members. The access of a visitor involved changes in one's eye-level view and established physical and psychological boundaries, which this study conjectures was used as a method to ensure that the visitor recognized the authority of the patriarch and to raise the family's reputation. As their floor plan was simplified, Izumi Fumoto samurai houses established one's eye view, boundaries, and procedures as a way to enhance the authority of the man of the family and the family's reputation. In addition, while there was an increasing number of residences that expanded the area of the Nando, in which family members slept and used the space in a stable way, they maintained the exclusivity of private space and did not clearly show who would use it.

Orthodontic appliances and MR image artefacts: An exploratory in vitro and in vivo study using 1.5-T and 3-T scanners

  • Sonesson, Mikael;Al-Qabandi, Fahad;Mansson, Sven;Abdulraheem, Salem;Bondemark, Lars;Hellen-Halme, Kristina
    • Imaging Science in Dentistry
    • /
    • v.51 no.1
    • /
    • pp.63-71
    • /
    • 2021
  • Purpose: The aim of this study was to assess the artefacts of 12 fixed orthodontic appliances in magnetic resonance images obtained using 1.5-T and 3-T scanners, and to evaluate different imaging sequences designed to suppress metal artefacts. Materials and Methods: In vitro, study casts of 1 adult with normal occlusion were used. Twelve orthodontic appliances were attached to the study casts and scanned. Turbo spin echo (TSE), TSE with high readout bandwidth, and TSE with view angle tilting and slice encoding for metal artefact correction were used to suppress metal artefacts. Artefacts were measured. In vivo, 6 appliances were scanned: 1) conventional stainless-steel brackets; 2) nickelfree brackets; 3) titanium brackets; 4) a Herbst appliance; 5) a fixed retainer; and 6) a rapid maxillary expander. The maxilla, mandible, nasopharynx, tongue, temporomandibular joints, and cranial base/eye globes were assessed. Scores of 0, 1, 2, and 3 indicated no artefacts and minor, moderate, and major artefacts, respectively. Results: In vitro, titanium brackets and the fixed retainer created minor artefacts. In vivo, titanium brackets caused minor artefacts. Conventional stainless-steel and nickel free brackets, the fixed retainer, and the rapid maxillary expander caused major artefacts in the maxilla and mandible. Conventional stainless-steel and nickel-free brackets caused major artefacts in the eye globe (3-T). TSE with high readout bandwidth reduced image artefacts in both scanners. Conclusion: Titanium brackets, the Herbst appliance, and the fixed retainer caused minor artefacts in images of neurocranial structures(1.5-T and 3-T) when using TSE with high readout bandwidth.

Development of Dot Sight with Prism Beam Splitter (빔분리프리즘 도트사이트 장치의 개발)

  • Lee, Dong-Hee;Jung, Bo-Seon;Park, Seung-Hwan
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.4
    • /
    • pp.519-524
    • /
    • 2013
  • Purpose: This study relates to the development of dot-sight device, whose length is reduced, with a prism beam splitter. Methods: We developed a new dot-sight device whose length was reduced by eliminating the optical axis tilt of the doublet reflector to reduce the occurrence of the parallax and by redesigning the doublet reflector to use a prism beam splitter. Results: We could develop the new type dot-sight device having a prism beam splitter and the dot reticle generator and the doublet reflector, of which optical axises showed a T-letter type with the optical axis of the observer's eye. Conclusions: In this study, we designed and developed a new type dot sight employing a prism beam splitter that could be able to further enhance the accuracy of the fire in comparison with the traditional dot sight, thereby reducing the overall optical length of system. The new designed dot sight was able to be reduced 2.2 times on the overall optical length, and could be improved more than three times on the accuracy of shooting in the horizontal direction, than the traditional dot sight.

The evaluation of lens absorbed dose according to the Optimold for whole brain radiation therapy (전뇌 방사선치료 시 Optimold에 따른 수정체의 흡수선량 평가)

  • Yang, Yong Mo;Park, Byoung Suk;Ahn, Jong Ho;Song, Ki Won
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.1
    • /
    • pp.77-81
    • /
    • 2014
  • Purpose : In the current whole brain Radiation Therapy, Optimold was used to immobilize the head. However, skin dose was increased about 22% due to the scattering radiation by the Optimold. Since the minimum dose causing cataracts was 2 Gy, it could be seen that the effects were large especially on the lens. Therefore, in the whole brain Radiation Therapy, it was to compare and to evaluate the lens absorbed dose according to the presence of Optimold in the eyeball part. Materials and Methods : In order to compare and to evaluate the lens absorbed dose according to the presence of Optimold in the eyeball part, the Optimold mask was made ??up to 5mm bolus on the part of the eye lens in the human model phantom (Anderson Rando Phantom, USA). In the practice treatment, to measure the lens dose, the simulation therapy was processed by placing the GafChromic EBT3 film under bolus, and after the treatment plan was set up through the treatment planning system (Pinnacle, PHILIPS, USA), the treatments were measured repeatedly three times in the same way. After removing the Optimold mask in the eyeball part, it was measured in the same way as above. After scanning the film and measuring the dose by using the Digital Flatbed Scanner (Expression 10000XL, EPSON, USA), the doses were compared and evaluated according to the presence of Optimold mask in the eyeball part. Results : When there was the Optimold mask in the eyeball part, it was measured at $10.2cGy{\pm}1.5$ in the simulation therapy, and at $24.8cGy{\pm}2.7$ in the treatment, and when the Optimold mask was removed in the eye part, it was measured at $12.9cGy{\pm}2.2$ in the simulation therapy, and at $17.6cGy{\pm}1.5$ in the treatment. Conclusion : In case of removing the Optimold mask in the eyeball part, the dose was increased approximately 3 cGy in the simulation therapy and was reduced approximately 7 cGy in the treatment in comparison to the case that the Optimold mask was not removed. During the whole treatment, since the lens absorbed dose was reduced about 27%, the chance to cause cataracts and side effects was considered to be reduced due to decrease of the absorbed dose to the eye lens which had the high sensitivity on the radiation.

Effects of Object-Background Contextual Consistency on the Allocation of Attention and Memory of the Object (물체-배경 맥락 부합성이 물체에 대한 주의 할당과 기억에 미치는 영향)

  • Lee, YoonKyoung;Kim, Bia
    • Korean Journal of Cognitive Science
    • /
    • v.24 no.2
    • /
    • pp.133-171
    • /
    • 2013
  • The gist of a scene can be identified in less than 100msec, and violation in the gist can influence the way to allocate attention to the parts of a scene. In other words, people tend to allocate more attention to the object(s) inconsistent with the gist of a scene and to have better memory of them. To investigate the effects of contextual consistency on the attention allocation and object memory, two experiments were conducted. In both experiments, a $3{\times}2$ factorial design was used with scene presentation time(2s, 5s, and 10s) as a between-subject factor and object-background contextual consistency(consistent, inconsistent) as a within-subject factor. In Experiment 1, eye movements were recorded while the participants viewed line-drawing scenes. The results showed that the eye movement patterns were different according to whether the scenes were consistent or not. Context-inconsistent objects showed faster initial fixation indices, longer fixation times, more frequent returns than context-consistent ones. These results are entirely consistent with those of previous studies. If an object is identified as inconsistent with the gist of a scene, it attracts attention. Furthermore, the inconsistent objects and their locations in the scenes were recalled better than the consistent ones and their locations. Experiment 2 was the same as Experiment 1 except that a dual-task paradigm was used to reduce the amount of attention to allocate to the objects. Participants had to detect the positions of the probe occurring every second while they viewed the scenes. Nonetheless, the result patterns were the same as in Experiment 1. Even when the amount of attention to allocate to the scene contents was reduced, the same effects of contextual inconsistency were observed. These results indicate that the object-background contextual consistency has a strong influence on the way of allocating attention and the memory of objects in a scene.

  • PDF

Comparisons of the Change in Soft Contact Lenses Parameters and the Cleaning Efficiency after Eyeliner Deposition (아이라이너 침착에 의한 소프트 콘택트렌즈 파라미터의 변화 및 세척효과의 비교)

  • Park, Mijung;Kim, Sa Hyun;Ku, Bo Kyoung;Kim, So Ra
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.2
    • /
    • pp.107-115
    • /
    • 2013
  • Purpose: This study was conducted to investigate the change of soft contact lens parameters after eyeliner deposition and compare the cleaning efficiency and the recovery rate of lens parameters by different cleaning methods. Methods: The eyeliner was deposited on three types of soft contact lenses made of different materials for 1 hour, 4 hours and 6 hours and those lenses were washed by the eyeglasses ultrasonic cleaning and by hands. The changes in visible light transmittance, diameter and surface of those lenses were compared before and after cleaning of the lens. Results: The visible light transmittance of soft contact lenses decreased along with the deposition time of eyeliner. The patterns of the eyeliner deposition on soft contact lens appeared differently depending on the physical properties of the lens material. Thus, the largest eyeliner deposition was found on narafilcon A lens. The diameters of hilafilcon B and etafilcon A lenses were decreased, however, the diameter of narafilcon A lens was increased. The cleaning efficiency of the eyeliner deposition was greater with the multipurpose solution by hands than with the eyeglasses ultrasonic cleaner. However, the recovery of lens parameters such as the lens diameter, visible light transmittance and lens surface due to the eyeliner deposition to its original state was limited. Conclusions: From these results, it is suggested to minimize eye makeup when wearing soft contact lens. Furthermore, the reduced wearing time and shorter cycle of lens replacement may be needed by considering a change of lens parameter when the repeat eye makeup is applied.

Effects of UV-A Blocking Contact Lenses on the Enzymes Denaturation Induced by UV-A Irradiation (UV-A로 유발된 효소 변성에 대한 콘택트렌즈의 차단 효과)

  • Park, Mijung;Lee, Keum Hee;Lee, Eun Kyung;Park, Sang Hee;Kim, So Ra;Lee, Heum Sook
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.4
    • /
    • pp.43-49
    • /
    • 2008
  • Purpose: The current study was conducted to evaluate the compatibility of UV-A blocking contact lens on eye protection with regular contact lens. Methods: The protective activity of regular contact lens (UV-A blocking: 20%) and UV-A blocking contact lens (UV-A blocking: 85%) on the denaturation of RNase A, catalase, and superoxide dismutase (SOD) induced UV-A irradiation were compared by acrylamide gel electrophoresis. The enzyme solutions were irradiated with UV-A for 1, 3, 6, 24 and 96 hours at the wavelength of 365 nm. Covering area with contact lenses were varied as 50%, 70% and 100% according to the calculation of blocking areas of anterior eye that could be covered with RGP lens, soft contact lens, and eye glasses, respectively. Results: Denaturations of RNase, catalase and SOD were exaggerated when they were exposed to UV-A for a longer period. The denaturation was effectively prevented by UV-A blocking contact lens compared to regular contact lens. The capability of UV-A blocking contact lens was considerably reduced when the covering area with contact lens decreased and exposure time to UV-A extended. Conclusion: Therefore, it would be suggested that wearing contact lens for a long time under sunlight is carefully considered since the activity of UV-A blocking contact lens against UV-A irradiation may not be enough to protect enzymes presented in eyes when exposure time to UV-A increased.

  • PDF

Toxic Optic Neuropathy Caused by Chlorfenapyr Poisoning (클로르페나피르 음독 후 발생한 독성 시신경병증 1예)

  • Park, Su Jin;Jung, Jae Uk;Kang, Yong Koo;Chun, Bo Young;Son, Byeong Jae
    • Journal of The Korean Ophthalmological Society
    • /
    • v.59 no.11
    • /
    • pp.1097-1102
    • /
    • 2018
  • Purpose: To report a case of toxic optic neuropathy caused by chlorfenapyr ingestion accompanied by central nervous system involvement. Case summary: A 44-year-old female visited our clinic complaining of reduced visual acuity in both eyes for 7 days. She had ingested a mouthful of chlorfenapyr for a suicide attempt 2 weeks prior to the visit. Gastric lavage was performed immediately after ingestion at the other hospital. Her best-corrected visual acuity was finger count 30 cm in the right eye and hand motion in the left eye. Both pupils were dilated by 5.0 mm and the response to light was sluggish in both eyes. A relative afferent pupillary defect was detected in her left eye. Funduscopy revealed optic disc swelling in both eyes. Magnetic resonance imaging of the brain showed a symmetric hyper-intense signal in the white matter tract including the internal capsule, corpus callosum, middle cerebellar peduncle, and brainstem. The patient was diagnosed with toxic optic neuropathy induced by chlorfenapyr ingestion, and underwent high-dose intravenous corticosteroid pulse therapy. Three days later, the best-corrected visual acuity was no light perception in both eyes. Three months later, optic atrophy was observed in both eyes. Optical coherence tomography revealed a reduction in the thicknesses of the retinal nerve fiber layer and ganglion cell and inner plexiform layer in the macular area. Conclusions: Ingestion of even a small amount of chlorfenapyr can cause severe optic nerve damage through the latent period, despite prompt lavage and high-dose steroid treatment.

A study on the Design and Application of a TIR Lens for Realizing A Compact Spot-Type UV Curing Machine Optical System (컴팩트한 Spot형 UV 경화기 광학계를 구현하기 위한 TIR 렌즈 설계 및 응용에 관한 연구)

  • Kim, Yu-Rim;Heo, Seung-Ye;Lee, Sang-Wook;Kim, Wan-Chin
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.17 no.2
    • /
    • pp.255-264
    • /
    • 2022
  • The conventional spot-type UV curing machine configures a collimator optical system using a plurality of lenses so that the light beam is incident through an optical cable. In order to increase the transmission light efficiency, a collimator optical system composed of three or more lenses is required, and accordingly, it is difficult to align the optical system, and it is difficult to implement the system compactly. In this study, a single TIR lens collimator that can realize the same level of spot diameter and light efficiency as the conventional collimator optical system composed of three lenses was designed. Through this, the light efficiency at the curing area with the minimum illuminance deviation was 33.2 %, which was similar to the performance of the reference collimator optical system, and the illuminance deviation on the curing area was 18.8 %, ensuring acceptable performance. In addition, by arranging a fly-eye lens with field flattening function at the front end of the condensing lens, the effective curing area diameter was reduced from 5.0 mm to 3.0 mm, enabling higher curing energy density to be realized. In addition, it was confirmed that the illuminance deviation can be greatly improved to a level of 14.4%.