• Title/Summary/Keyword: rectangular pressure pulse

Search Result 15, Processing Time 0.025 seconds

The Fundamental Study on Pulse Jet Cleaning of Rectangular Bag-Filter System (사각형 여과 집진기 충격기류 탈진시스템의 기초 연구)

  • Piao, Cheng Xu;Kim, Tae Hyeung;Yang, Jun Ho;Li, Xiao Yu;Ha, Hyun Chul;Jung, Jae Hun
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.18 no.2
    • /
    • pp.149-160
    • /
    • 2008
  • Bag-filter system has been widely used in industrial field to remove the particulate matters from the exhaust gas. The cylindrical type of bag-filter has been generally used. But it has many shortcomings. The reattachment of separated particles on the surface of bags could result in high pressure drop of bag-filter system and subsequent decrease of air flow rate since the cylindrical type bag-filter system should have the upward flow pattern. In addition, the supply of very high pressure pulse air jet to remove particulate matters on the surface of filter could result in a frequent rupture of bags. To overcome these shortcomings of the cylindrical type, the rectangular type was developed in the developed countries and imported to Korea. But, there was not many design data available to understand the mechanisms. Thus, the fundamental experiments were conducted in this study to get some ideas about the pulse jet cleaning of rectangular type bag filter system. The experimental factors are as follows; pulse distance, pulse duration, pulse interval, pulse pressure and pulse nozzle type. Experiments followed the factorial design method. With the shorter pulse distance, the distribution of pressure drops was relatively not uniform while the particulate removal efficiency was higher. With the longer duration of pulsing and the more number of pulse nozzle, the removal efficiency was higher and the pressure drop distribution was more uniform.

Experimental study on the optimum pulse jet cleaning conditions of a rectangular bag-filter system (사각형 여과집진기 충격기류 시스템의 최적탈진조건에 관한 실험적 연구)

  • Piao, Cheng Xu;Kim, Tae Hyeung;Li, Xiao Yu;Ha, Hyun Chul;Jung, Jae Hun
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.18 no.3
    • /
    • pp.189-203
    • /
    • 2008
  • Cylindrical bag filter system with pulse jet cleaning has been the most common device to control particle laden exhaust gas from the various industrial processes. But, it has many shortcomings due to particle reattachment and frequent bag rupture. In recent years, rectangular type bag filter system has been developed to overcome the problems associated with the cylindrical system. However, not many studies about the rectangular system were not done, compared to the cylindrical system. In this study, the optimum pulse jet cleaning conditions were thus tested by the series of experiments. The factors tested in this study are pulse distance, pulse pressure, pulse duration, the number of holes for pulsing and bag materials. A single bag ($1,500mmL{\times}50mmW{\times}300mmH$) system and a multi-bags (3 bags in a row) were tested separately. The highest removal efficiency with a single bag system was found at the conditions with pulse distance of 10cm, pulse pressure of $3kg/cm^2$, pulse duration of 0.3s, pulse jet number of 6 and Polyester bag. With the multi-bags system, the best cleaning conditions were found at the bag interval of 20cm with the simultaneous pulsing and the bag interval of 15cm with the serial pulsing.

Experimental Study on Optimum Pulse Jet Cleaning Conditions of a Cartridge Filter System (카트리지 필터 여과집진기 충격기류시스템의 최적탈진조건에 관한 실험적 연구)

  • Piao, Cheng Xu;Ha, Hyun Chul;Kim, Sung Joon
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.25 no.4
    • /
    • pp.542-553
    • /
    • 2015
  • Objectives: Many types of dust collector are used for industrial ventilation, with the most common types being the cylinder bag filter system, rectangular bag filter system and cylinder type cartridge filter system. The cylinder type cartridge bag filter, which has more filtering area than other types of bag filter, can increase the pulse time and extend the useful life of the filter. This can save operational costs and installation area. Materials: This study used cylinder type cartridge bag filter equipment and tested the impact of vibration level and filter pressure with different pulse jet cleaning conditions. The final, cleaning efficiency was calculated through input dust mass and cleaning dust mass Conclusions: Two optimum cleaning condition groups were found. The first condition group was $3kgf/cm^2$ pulse pressure, 15 cm pulse distance, 0.2 s pulse time with an H-10 type nozzle. The second condition group was $3kgf/cm^2$ pulse pressure, 15 cm pulse distance, 0.3 s pulse time with an H-10 type nozzle.

Saturation impulses for dynamically loaded structures with finite-deflections

  • Zhao, Ya-Pu;Yu, T.X.;Fang, J.
    • Structural Engineering and Mechanics
    • /
    • v.3 no.6
    • /
    • pp.583-592
    • /
    • 1995
  • The concept of "Saturation Impulse" for rigid, perfectly plastic structures with finite-deflections subjected to dynamic loading was put forward by Zhao, Yu and Fang (1994a). This paper extends the concept of Saturation Impulse to the analysis of structures such as simply supported circular plates, simply supported and fully clamped square plates, and cylindrical shells subjected to rectangular pressure pulses in the medium load range. Both upper and lower bounds of nondimensional saturation impulses are presented.

Evaluation of Local Loss Coefficients for Different Waveguide-Below-Cutoff (WBC) Arrays of Electromagnetic Pulse (EMP) Shied in Buildings (도파관 배열에 의한 국부저항계수 산정)

  • Pang, Seung Ki;Chae, Young Tae
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.7
    • /
    • pp.366-372
    • /
    • 2017
  • The objective of this study was to characterize Waveguide-Blow-Cutoff (WBC) array for Electromagnetic Pulse (EMP) shield in air duct or water pipe, the typical pathway of pulse in indoor space with critical electronic device. A numerical investigation with three different WBC designs (circular, rectangular, and hexagonal or honeycomb) was conducted to satisfy recommended shielding effectiveness (SE) levels from 80 dB to 140 dB. Pressure drop between upstream and downstream of EMP shields based on WBC arrays was also investigated to understand air flow feature in air duct of HVAC system. Results showed that honeycomb geometry outperformed other shapes in terms of reducing the depth of EMP shield, thus providing better air flow in duct path with lower local loss coefficient in HVAC system under SE requirements.

Two-dimensional model analysis for the pulse tube of rotating pulse tube refrigerator (회전하는 맥동관 냉동기의 맥동관에 대한 2차원 모델 해석)

  • Chai J.;Jeong S.;Jeong Eun-Soo
    • Progress in Superconductivity and Cryogenics
    • /
    • v.8 no.3
    • /
    • pp.63-69
    • /
    • 2006
  • This paper describes the effect of rotating frequency on the pulse tube of Stirling type pulse tube refrigerator. Various conditions were analyzed by two-dimensional analysis with several dominant non-dimensional parameters. With the additional pressure term influenced by centrifugal force in rotating condition, the linearized conservation equations of mass, momentum, energy of the gas were solved to obtain the first order variables and calculate the enthalpy flow in rectangular coordinates. The rotational effect in pulse tube for the refrigerator's performance were quantitatively evaluated. According to the first order analysis, the enthalpy flow decreases with the rotating speed.

The electrical and optical properties of Xe plasma in flat lamp (평판형 광원에서 제논(Xe) 플라즈마의 전기적 광학적 특성 연구)

  • Pack, Gwang-Hyeon;Yang, Jong-Kyung;Lee, Jong-Chan;Chio, Yong-Sung;Park, Dae-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.05b
    • /
    • pp.60-64
    • /
    • 2005
  • Discharge of the flat lamp lighting source research are requested very much. For improving brightness, life time, efficiency of flat lamp, plasma diagnosis of the flat lamp lighting source to understand property of lighting source is very important, distance of discharge electrode is 5.5mm and width is 16.5mm, we measured electron temperature and electron density measured with single langmuir probe in flat lamp, we tested the discharge from 100 Torr to 300 Torr pressure, the Pulse is rectangular pulse with frequency 20kHz and Duty ratio 20%. Resultly, electron temperature decreases and electron density increase as increase the gas pressure and electron temperature decreases and electron density increase as increase the voltage.

  • PDF

Electrical and Optical Properties of Xe Plasma in Flat Lamp (평판형 광원에서 제논 플라즈마의 전기적 및 광학적 특성)

  • Choi, Yong-Sung;Lee, Kyung-Sup
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.12a
    • /
    • pp.71-74
    • /
    • 2006
  • Discharge of the flat lamp lighting source research arc requested very much. For improving brightness, life time, efficiency of flat lamp, plasma diagnosis of the flat lamp lighting source to understand property of lighting source is very important. distance of discharge electrode is 5.5mm and width is 16.5mm, we measured electron temperature and electron density measured with single langmuir probe in flat lamp. we tested the discharge from 100 Torr to 300 Torr pressure. the Pulse is rectangular pulse with frequency 20kHz and Duty ratio 20%. Resultly, electron temperature decreases and electron density increase as increase the gas pressure and electron temperature decreases and electron density increase as increase the voltage.

  • PDF

Electrical and Optical properties of Xe gas in flat lighting source (제논(Xe) 가스를 사용한 평판형 광원에서의 전기 및 광학적 특성 연구)

  • Pack, Gwang-Hyeon;Yang, Jong-Kyung;Lee, Jong-Chan;Choi, Yong-Sung;Park, Dae-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2005.07c
    • /
    • pp.2190-2192
    • /
    • 2005
  • Discharge of the flat lamp lighting source research are requested very much. For improving brightness, life time, efficiency of flat lamp, plasma diagnosis of the flat lamp lighting source to understand property of lighting source is very important. distance of discharge electrode is 5.5mm and width is 16.5mm, we measured electron temperature and electron density measured with single langmuir probe in flat lamp. we tested the discharge from 100 Torr to 300 Torr pressure. the Pulse is rectangular pulse with frequency 20kHz and Duty ratio 20%. Resultly, electron temperature decreases and electron density increase as increase the gas pressure and electron temperature decreases and electron density increase as increase the voltage.

  • PDF

Study on the plastic deformation of a cylinder subjected to localized impulsive pressure (국부충격하중을 받는 원관의 삭성변형에 관한 고찰)

  • ;;Zoo, Young Woo
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.5 no.2
    • /
    • pp.131-138
    • /
    • 1981
  • The effect of axial stress on the plastic deformation of rigid-perfectly plastic cylindrical tube under the impulsive band pressure is investigated. It is assumed that the tube is constructed with the material of Tresca's yield criterion. A closed from sloution is obtained for a rectangular pulse shape of uniform band pressure by using the circumscribed yield surface. The analysis shows that the effect ot exial stress is negligible when the dimensionless axial stress(n$\sub$x/= N$\sub$x/.delta.$\sub$y/H) is less than 0.2 or the dimensionless whdth of band pressure(.xi.=C/.root.RH) is greater than 2, but the effect of axial stress is of considerable importance when the axial stress is greater than 0.3 and the width of band pressure is less than 1.