• Title/Summary/Keyword: rectal temperature

Search Result 350, Processing Time 0.033 seconds

Comparison by Measurement Sites in Temperature of Neonates : Ear-based rectal, Rectal, Axilla, Abdominal Temperature (측정부위별 신생아의 체온 비교 : 고막기준 직장체온, 직장체온, 액와체온, 복부체온)

  • 김화순;안영미
    • Journal of Korean Academy of Nursing
    • /
    • v.29 no.4
    • /
    • pp.903-916
    • /
    • 1999
  • The purpose of this study was to compare the ear-based rectal temperature measured with a tympanic thermometer with the rectal temperature measured with a glass mercury thermometer in order to test the accuracy of tympanic thermometer and to determine relationship among rectal, axilla, and abdominal temperature in neonates. The samples consisted of thirty four neonates admitted to the neonatal intensive care unit and nursery at an university affiliated hospital. The mean age of the subjects was 4.9 days. The ear-based rectal temperatures were taken with a tympanic thermometer in rectal mode (First Temp Genius 3000). Rectal and axilla temperatures were taken with a glass mercury thermometer, Abdominal temperature was continuously monitored with the probe connected to the servo controller of incubator. The results of the study can be summarized as follows : 1. Intrarater comparison : Agreement between the first and the second ear-based rectal temperature was 97% within 0.1$^{\circ}C$. 2. Comparison of ear-based rectal temperature and the rectal temperature from a glass mercury thermometer : ear-based rectal temperature ranged from 36.95$^{\circ}C$d to 37.95$^{\circ}C$, with a mean of 37.58$^{\circ}C$(SD=0.22$^{\circ}C$). Rectal temperature from a glass mercury thermometer ranged from 36.2$0^{\circ}C$ to 37.2$0^{\circ}C$, with a mean 36.75$^{\circ}C$(SD=0.29). The mean difference between both temperatures was 0.84$^{\circ}C$. The correlation coefficient between both temperatures was r=0.77(p=0.00). 3. Comparison of rectal and axilla temperature : Axilla temperature ranged from 35.8$0^{\circ}C$ to 37.1$0^{\circ}C$, with a mean of 36.55$^{\circ}C$. The mean absolute difference between the rectal and axilla temperature was 0.23$^{\circ}C$. The correlation coefficient between rectal and axilla was r=0.67. 4. Comparison of axilla and abdominal temperature : Abdominal temperature ranged from 36.2$0^{\circ}C$ to 37.0$0^{\circ}C$, with a mean of 36.58$^{\circ}C$. The mean absolute difference between axilla and abdominal temperature was only -0.03$^{\circ}C$. Findings of this study suggest that ear-based rectal temperature overestimates the actual rectal temperatures in neonates. Therefore, the interchangeble use of both temperatures in clinics seems problematic. The site offset(adjustment value) programmed in rectal mode of the tympanic thermometer needs to be readjusted. Choosing one optimal site for temperature measurement for each patient, and using the specific site consistently would result in more consistent measurements of changes in body temperature, and thus can be more effective in diagnosing fever or hypothermia.

  • PDF

Comparison of Inguinal, Rectal, Axillary,and Tympanic Temperature in Newborns (신생아의 서혜, 직장, 액와, 고막 체온 측정 비교)

  • Koo, Hyun-Young;Son, Jung-Tae
    • Child Health Nursing Research
    • /
    • v.11 no.2
    • /
    • pp.203-210
    • /
    • 2005
  • Purpose: In order to identify the usability of inguinal temperature in a neonatal unit, this study was done to compare inguinal temperature of newborns with rectal, axillary, and tympanic temperatures. Method: Fifty-one normal newborns admitted to the nursery of a university affiliated hospital participated in the study. Tympanic temperatures were taken with a tympanic thermometer. Inguinal, rectal, and axillary temperatures were taken with glass mercury thermometers, and were recorded every 1 minute until the reading remained constant for 2 times. The data were analyzed using the SPSS program. Result: The measurement time for inguinal temperatures in newborns was significantly longer than that for rectal temperatures, but was shorter than that for axillary temperatures. The mean temperature for the newborn's inguinal site was lower than for rectal, axillary, and tympanic temperatures (the lower side), but wasn't different from tympanic temperature (the upper side). The inguinal temperature was significantly correlated with rectal, axillary, and tympanic temperature. The inguinal temperature was not different according to general characteristics of the newborn. Conclusion: These findings indicate that measurement of inguinal temperature is a useful alternative to rectal temperature.

  • PDF

Comparison of Rectal Temperature with Axillary and Tympanic Temperature (신생아의 직장체온과 고막 및 액와체온과의 비교)

  • Hwang Jin-Soon;Sohng Kyeong-Yae
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.4 no.2
    • /
    • pp.351-358
    • /
    • 1997
  • Body temperature should be measured accurately to assess neonate's condition for proper care. Temperatures measured in rectal, axillary and tympanic site were compared in 129 normal neonates to find out proper nursing time for measuring temperature and the validity of fever detection. The results were as follows : 1. Mean temperatures of axillary and tympanic site($36.85^{\circ}C,\;37.12^{\circ}C$) were significantly lower than those of rectal site($37.19^{\circ}C$). 2. Mean nursing time for measuring body temperature was significantly higher and lower in axillary and tympanic temperatures(159.49 seconds, 11.07 seconds) than in rectal temperature(105.62 seconds). 3. Tympanic and axillary temperatures were significantly correlated with rectal temperature (r=0.85, r=0.78) and the significant correlation was demonstrated between tympanic and axillary temperatures(r=0.76). 4. Sensitivity, specificity, positive and negative predictive values were 0.87, 0.90, 0.72, 0.96 for detecting fever respectively. The above findings indicated that the tympanic thermometer offers a useful alternative to conventional methods.

  • PDF

Effectsd of posture on physiological thermal responses with Ondol heating system (온돌난방에서의 자세에 따른 온열생리적 반응의 성차)

  • 신정화;최정화
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.22 no.8
    • /
    • pp.1020-1031
    • /
    • 1998
  • This study was done to investigate thermal reponses and to obtain the basic information of thermal comfort by sex and posture under the Ondol heating system. Six healthy males and females were exposed to Ondol(Room Temp.: 25$\pm$1$^{\circ}C$, 50$\pm$10%R.H, Floor Temp.:30$\pm$1$^{\circ}C$) on the of posture such as sitting, lying aside and supine on the floor for 30 minutes after 30 minutes' control phase. During the experiment, rectal temperature, skin temperature of 10 areas, local sweating rate, clothing microclimate, subjective sensation were measured. Rectal temperature gradually decreased and mean skin temperature grad-ually increased both male and female in any posture. There was not significant difference between male and female in rectal temperature and mean skin temperature. There were significant difference among the postures in rectal temperature(p<0.001) and mean skin temperature(p<0.001). In lying aside and supine on the floor, appearances of change and changes in rectal temperature and mean skin temperature were large, changes of weight were small. In sitting on the floor, appearances of change and changes in rectal temperature and mean skin temperature were small, changes of weight were large. The trunk skin tem-perature was higher in female than in male, but the extremity skin temperature was higher in male than in female. In sitting on the floor, foot skin temperature(p<0.001) was higher than any other local skin temperature. In supine on the floor, back skin temperature(p<0.001) was higher than any other local skin temperature.

  • PDF

Comparison of Rectal and Infrared Thermometry for Obtaining Body Temperature of Gnotobiotic Piglets in Conventional Portable Germ Free Facility

  • Chung, Tae-Ho;Jung, Woo-Sung;Nam, Eui-Hwa;Kim, Ji-Hyun;Park, Seol-Hee;Hwang, Cheol-Yong
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.23 no.10
    • /
    • pp.1364-1368
    • /
    • 2010
  • Gnotobiotic piglets (n = 10) were hand-reared in conventional germ-free facilities. Piglet body temperatures were measured with rectal and non-contact infrared thermometry (NIFT) on the lower eyelid, auricular center and margin, parietal regions, axilla, central abdomen and dorsum, and the perianal region. Body temperature measurements at central abdomen, cranial dorsum, and perianal regions had NIFT values which had a significant linear relationship (p<0.0001) with rectal thermometry. The predicted equations of between-subject formulas were calculated as follows: rectal temperature, 28.07489+0.30372${\times}$central abdominal surface temperature; rectal temperature, 34.02799+0.15197${\times}$central dorsum surface temperature; and rectal temperature, 33.87937+0.15676${\times}$perianal temperature. These results suggested that NIFT could serve as a valid alternative to rectal thermometry in a portable germ-free facility without disturbing experimental animals. The development of a NIFT body temperature evaluation that does not require animal restraint is clinically advantageous, particularly in gnotobiotic piglets, and would be significantly less stressful for experimental procedures in germ-free facilities.

Thermoregulatory Responses in the Elderly and the Young under the Ondol System (온돌난방에서 노인과 청년의 피부온 반응 비교)

  • 정유정;최정화
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.22 no.1
    • /
    • pp.149-158
    • /
    • 1998
  • The purpose of this study was to investigate the effect of age on the human thermoregulatory responses and to obtain the basic information of the Korean thermophysiological characteristics under the traditional Korean floor heating system-Ondol. The participants consisted of 10 elderly women, 4 elderly men(over 65 years), 10 young women and 5 young men(in twenties). They were exposed to temperature-controlled Ondol room(20$\pm$1$^{\circ}C$, 50$\pm$5%R.H., floor surface temperature: 30$\pm$1$^{\circ}C$) for 60 minutes and wore the same experimental clothing. The postures were performed sitting and supine on the floor. In each pose, rectal temperature, skin.temperature of 10 areas, mean skin temperature, clothing microclimate, body fat were measured. The results were as follows; 1. The rectal temperature gradually decreased and mean skin temperature gradually increased in young and old groups in both supine and sitting pose on heated Ondol floor for 60 minutes. 2. Rectal temperature was different in each pose. The rectal temperature decreased 0.1$^{\circ}C$ in both groups under the condition of sitting and decreased 0.2'c in elderly group under the condition of supine. In supine pose, elderly group was more declined than young group. Mean skin temperature increased 0.5$^{\circ}C$ in both poses, both groups.

  • PDF

Effects of Berberis koreana Palibin on Sleep Duration and Rectal Temperature in Mouse (매자나무성분이 마우스 수면 및 체온에 미치는 영향)

  • Cho Sun-Hee;Kim Chung-Il
    • The Korean Journal of Pharmacology
    • /
    • v.10 no.1 s.15
    • /
    • pp.61-65
    • /
    • 1974
  • Berberis koreana Palibin belonging to Berberidaceae family, a common herb in Korea, has been contained some quantity of Berberine analogue and other ingredients. Authors therefore paid attention to its pharmacological actions and examined the effects on sleep duration and rectal temperature in mouse with crystal (A) from Berberis koreana Palibin in Korean native plans. The experiment searching for the effect on sleep duration was performed with pretreatment of Berberis Koreana Palibin crystal (A) 30 min before the administration of 25 % ethanol, and its crystal were also administered intraperitoneally with the intention to examine the effect on rectal temperature in mouse. The results of the experiment were as follows; 1. Crystal (A) from Berberis koreana Palibin was made by extraction with ethanol and HCI. 2. Crystal (A) enhanced the hypnotic activity of alcohol in concentratins of 0.1 mg/10g or 0.15 mg/10g. 3. Rectal temperatures in mice were significantly reduced with administration of crystal (A) in concentrations of 0.1 mg/10g or 0.15 mg/10g. 4. The maximal reduction of rectal temperature and potentiation of the hypnotic activity were observed at 30 min after its administration. From the above results, it is clear that crystal (A) from Berberis koreana Palibin exerts the potentiation of hypnotic action of alcohol and reduction of rectal temperature in normal mouse. Its pharmacological effects are probably derived from the action upon the central nervous system.

  • PDF

Changes of Rectal Temperature in Mice Exposed to Cold With and Without Restraint(1) (결박 및 비결박한 마우스의 한냉에 대한 직장온도의 변동에 대하여(1))

  • 김정진
    • The Korean Journal of Zoology
    • /
    • v.7 no.1
    • /
    • pp.23-28
    • /
    • 1964
  • 120 mice of both sexes weighing from 18 to 22 g. were used. These mice were divided nito 12 groups : control (non-restraint and restraint) , acclinmation (non-restraint and restraint , acclimation for 5 and 10 days) , adrenalectomized (non-restraint and restraint0 and acclimation-adrenalectomized (non-restraint and restraint, acclimation for 5 and 10 days) groups. The rectal temperature of each group were measured at 10, 30 and 50 min under environment of $0^{\circ}C$.Measurements were done with a microphrometer of B.T.-32 thermocorpules. The results obtained may be summarized as follows : 1) The rectal temperature in normal mice without restraint was higher than that of normal mice with restraint under environment of $0^{\circ}C$. 2) The rectal temperature in normal mice was higher than that of adrenalectomized mice at 20$^{\circ}$ C. But the rectal temperature in adrenalectomized mice without restraint was higher than that of adrenalectomized mice with restraint under cold-stress. This difference was in the order of 1.65$^{\circ}$ under environment of 20$^{\circ}$ and 10 $^{\circ}$ at 50 min under environment of 0$^{\circ}$. 3) The rectal temperature of normal mice with restraint was less than that of adrenalectomized mice (non-restraint) under cold-stress. 4) The rectal temperature of normal and adrenalectomized mice that acclimated under cold stress ($0^{\circ}C$) for 5 and 10 days was usually higher than that of normal and adrenalectomized mice of non-acclimation under environment of $0^{\circ}C$. 5) The tolerance in mice under cold-stress was increased on the acclimtion of cold.

  • PDF

Development of Automatic Measurement of Body Temperature by Taking the Temperature of Milk while Milking in Dairy Cattle (젖소에서 유즙체온 측정을 이용한 체온 자동 측정 방법의 개발)

  • 김용준;한종현;이수영;한병성;김동원
    • Journal of Veterinary Clinics
    • /
    • v.19 no.1
    • /
    • pp.37-42
    • /
    • 2002
  • To develop an automatic detecting system of body temperature of dairy cattle while milking, measurement of the temperature of mammary skin using three thermometers attached into the lining of teat cup was carried out for 23 dairy cattle, whereas measurement of the temperature of milk while milking was also performed for 263 animals. For the latter experiment, three thermometers were attached at 10cm(left and right) and 20 cm away from an individual milk collector on the milk transporting hose. Taking the rectal temperature was accompanied all the time for the experiments. The measurement of the temperature of mammary skin using teat cup was successful for 11 of 23 dairy cattle(47.8%) and the mean temperature was $33.5^{\circ}C$ with the mean difference of $5.2^{\circ}C$ from the mean rectal temperature. The measurement of the temperature of milk using the thermometers onto the milk transporting hose while milking was very successful , From 37.3 to $38.4^{\circ}C$ of rectal temperature, the temperature of milk was almost the same and from 38.5 to $39.5^{\circ}C$ of rectal temperature, the temperature of milk tended to be low with the difference of 0.1$^{\circ}C$. From 39.6 to $41^{\circ}C$ of rectal temperature, the temperature of milk tended to be low with the difference of $0.2-0.6^{\circ}C$. These results indicated that automatic detection of body temperature whether low or high can be possible if the temperature of milk is taken while milking and if it is connected to the integration system by on-line.

Assessment of the Clothing Wear Comfort for Elderly Women based on Rectal Temperature, Melatonin and Cortisol Analyses (직장온·멜라토닌·코티졸 분석을 통한 노년기 여성의 의복 착용 쾌적성 평가)

  • Bang, Ha Yeon;Kim, Hee Eun
    • Fashion & Textile Research Journal
    • /
    • v.15 no.2
    • /
    • pp.277-285
    • /
    • 2013
  • This study examines the wearing comfort of elderly women through a physiological analysis based on rectal temperature and biochemical analysis with salivary melatonin and cortisol. This study was conducted on 7 elderly women aged 65 or over. Two kinds of clothing ensemble (control and prototype) were used as experimental clothing. The control clothing was a general clothing ensemble and the prototype clothing lowered clothing pressure by adding an extra gap. The experimental schedule included daily living activities with randomly assigned experimental clothing. Rectal temperature was constantly measured every 5 minutes during the experiment and saliva samples for melatonin and cortisol were collected twice per day before and after sleep. The rectal temperature was lower for the prototype than the control throughout the experiment, and its circadian rhythm was prompt and clear in prototype. In addition, melatonin was secreted more but cortisol was secreted less when the subjects wore the prototype clothing. With these results, we assumed that regular circadian rhythm and low level of stress might be caused by wearing prototype clothing that lowered clothing pressure. The results demonstrate the necessity to develop clothing that considers body changes in elderly women.