• Title/Summary/Keyword: recovery ratio

Search Result 1,296, Processing Time 0.025 seconds

Performance Test of Low Temperature Waste Heat Recovery Heat Exchanger Using Self-excited Oscillating Heat Pipe (자려 진동형 히트 파이프를 이용한 저온 폐열 회수 열교환기의 성능 실험)

  • 이욱현;이종현;김종수
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.9
    • /
    • pp.853-859
    • /
    • 2000
  • In this study, low temperature waste heat recovery heat exchanger was developed using a principle of self-excited oscillating heat pipe. The heat exchanger of serpentine type was composed of extruded flat aluminum tube with 6 channels (3 nm$\times$ 2.75nm) and louvered fin. The heat transfer area density of heat exchanger was $331.9 m^2/m^3$. Working fluid is R141b and charge ratio was 40% by volume. Heat transfer rate and the effectiveness of heat exchanger was primary concern of this study. As a result, the effectiveness of heat exchanger was about 0.4-0.67, and recovered waste heat rate was about 4.5 kW per one unit of heat exchanger.

  • PDF

Analysis of Design and Part Load Performance for gas Turbine Cogeneration Systems (가스터빈 열병합발전 시스템의 설계점 설정 및 부분부하 성능해석)

  • 김동섭;노승탁
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.8
    • /
    • pp.2167-2176
    • /
    • 1994
  • This paper presents some useful design criteria for the turbine cogeneration system through both the design and off-design analysis. Comparative analysis of the part load performance is carried out for several gas turbines which have different design parameters represented by the turbine inlet temperature and pressure ratio. It is shown that the variation in part load efficiency considerably depends on the design parameter. The off-design operation of the heat recovery steam generator is simulated by introducing adequate assumptions for the heat transfer process. It is turned out that the design parameters of heat recovery steam generator should be determined by considering the favorable operation at the off-design conditions.

Signal Recovery of the Corrupted Metal Impact Signal using the Adaptive Filtering in NPPs

  • Kim, Dai-Il;Shin, Won-Ky;Oh, Sung-Hun;Yun, Won-Young
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1995.10a
    • /
    • pp.223-229
    • /
    • 1995
  • Loose Par Monitoring System(LPMS) is one of the fundamental diagnostic tools installed in the nuclear power plants. In this paper, recovery process algorithm and model for the corrupted impact signal generated by loose parts is presented. The characteristics of this algorithm can obtain a proper burst signal even though background noise is considerably high level comparing with actual impact signal. To verify performance of the proposed algorithm, we evaluate mathematically signal-to-noise ratio of primary output and noise. The performance of this recovery process algorithm is shown through computer simulation.

  • PDF

Clinical evaluation of thoracic empyema: review of 59 cases (농흉의 임상적 고찰: 59례 보)

  • 김현순
    • Journal of Chest Surgery
    • /
    • v.15 no.3
    • /
    • pp.274-277
    • /
    • 1982
  • A Clinical analysis of 59 patients of thoracic empyema was done who were received surgical intervention at dept. of thoracic surgery of the C.A.F.G.H. in the period of 2.5 years from January 1979 to June 1982. Occurrence ratio of Left and Right side pleural cavity of empyema was 1: 1.4. The predisposing factors of empyema were pulmonary Tbc. [49%], Chest pain [25%], Cough [8%], in order. B.P.F. was associated with empyema in 5 cases. The pleural cavity empyema was treated with several surgical procedures and conservative measures. Among of the 59 cases, the 30 cases [50%] were treated with decortication, 12 cases [20%] with closed thoractomy drainage, 9 cases with frequent thoracenteses, 5 cases with partial decortication and thoracoplasty and 3 cases with open thoracostomy tube drainage. Among of the 59 cases thoracic empyema, the full recovery were in 32 cases [54%], partial recovery in 20 cases [34%], not improved in 3 cases [5%] and 3 cases were died. The mortality rate was 5% and the recovery rate was 89%.

  • PDF

The Study on Resource Recovery of Sludge Containing Heavy Metals and its Residue Stabilization

  • Hu, Shao-Hua;Tsai, Min-Shing;Tyngbin Onlin
    • Proceedings of the IEEK Conference
    • /
    • 2001.10a
    • /
    • pp.448-452
    • /
    • 2001
  • An Experimental study was carried out to develop a simple method of processing copper waste sludge which is produced by PBC manufacturing. The procedure is based on leaching of wet sludge in 2N H$_2$SO$_4$, and the solid / liquid ratio is controlled approximately at 1/10. The recovery of copper is 85.4%, and pH of the leachate is 3.20. Adding ammonia solution into leachate forms ammine, and hydroxide compounds derived from other impurities in leachate at pH 10. The hydroxide compound can be treated by ferrite process, and the product is a stable oxide compound. Then the ammine solution is heated to evaporate ammonia, and the copper hydroxide is formed. Heating at 8$0^{\circ}C$by aeration, copper hydroxide is transformed into copper oxide with a purity of 98.4%. This process can recover most copper from sludge and the residue can be stabilized by the formation of a stable oxide compound which is not hazardous to environment.

  • PDF

Void Less Geo-Routing for Wireless Sensor Networks

  • Joshi, Gyanendra Prasad;Lee, Chae-Woo
    • Proceedings of the KIEE Conference
    • /
    • 2007.04a
    • /
    • pp.433-435
    • /
    • 2007
  • Geographic wireless sensor networks use position information for Greedy routing. Greedy routing works well in dense network where as in sparse network it may fail and require the use of recovery algorithms. Recovery algorithms help the packet to get out of the communication void. However, these algorithms are generally costlier for resource constrained position based wireless sensor type networks. In the present work, we propose a Void Avoidance Algorithm (VAA); a novel idea based on virtual distance upgrading that allows wireless sensor nodes to remove all stuck nodes by transforming the routing graph and forward packet using greedy routing only without recovery algorithm. In VAA, the stuck node upgrades distance unless it finds next hop node which is closer to the destination than itself. VAA guarantees the packet delivery if there is a topologically valid path exists. NS-2 is used to evaluate the performance and correctness of VAA and compared the performance with GPSR. Simulation results show that our proposed algorithm achieves higher delivery ratio, lower energy consumption and efficient path.

  • PDF

An Experimental Study on Air Leakage and Heat Transfer Characteristics of a Rotary-type Heat Recovery Ventilator

  • Han, Hwa-Taik;Kim, Min-Kyu
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.13 no.2
    • /
    • pp.83-88
    • /
    • 2005
  • This study investigates the air leakage and heat transfer characteristics of a commercially available rotary-type air-to-air heat exchanger with a fiber polyester matrix. Crossover leakage between the exhaust and supply air is measured using a tracer gas method for various ventilation rates and rotational speeds of the wheel. A correlation equation for the leakage is obtained by summing up pressure leakage and carryover leakage. The pressure leakage is observed to be a function of ventilation rate only, and the carryover leakage is found to be a linear function of wheel speed. The real efficiency of the heat exchanger can be obtained from its apparent efficiency by taking into account the leakage ratio. The heat recovery efficiency decreases, as the ventilation rate increases. As the wheel speed increases, however, the efficiency increases initially but reaches a constant value for the speeds over 10rpm.

Recovery Current Characteristics of the SC conductor for a $\mu$ SMES ($\mu$ SMES용 초전도도체의 회복전류 특성)

  • Kim, H.J.;Seong, K.C.;Cho, J.W.;Lee, E.Y.;Kwon, Y.K.;Ryu, K.S.;Ryu, K.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.807-809
    • /
    • 2000
  • We are developing a small-sized superconducting magnetic energy storage ($\mu$ SMES) magnet with the storage capacity of a few megajoules, which provides electric power with high quality to sensitive electric loads. As the earlier step of the fabrication of the $\mu$ SMES magnet, this paper describes recovery current experimental results of a kA class superconductor. Recovery current of a superconductor was tested in two points of copper ratio and cooling effect.

  • PDF

An Experimental Study on Air Leakage and Heat Transfer Characteristics of a Rotary-type Heat Recovery Ventilator (회전식 폐열회수 환기유닛의 공기누설 및 전열특성에 관한 실험적 연구)

  • Han Hwataik;Kim Min-Kyu
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.12
    • /
    • pp.1197-1203
    • /
    • 2004
  • This study investigates the air leakage and heat transfer characteristics of a rotary-type air-to-air heat exchanger with a fiber polyester matrix. The leakage airflow rate is measured using a tracer gas method for various ventilation rates and rotational speeds of the matrix wheel. A correlation equation for air leakage is obtained by combining the pressure leakage and the carryover leakage. The pressure leakage is observed to be a function of ventilation airflow rate only, and the carryover leakage is found to be a linear function of rotational speed. The real efficiency of the heat exchanger can be obtained from its apparent efficiencies by taking into account the air leakage ratio. As the ventilation rate increases, the heat recovery efficiency decreases. As the rotational speed of the matrix increases, the efficiency increases initially but reaches a constant value for the rotational speeds over 10 rpm.

Physical Properties According to the Covering Process and Heat Treatment Condition of the Thermoplastic Polyetherester Elastomeric Fibers (에스터계 열가소성 탄성 섬유의 커버링 공정 및 열처리 조건에 따른 물성 변화)

  • Kim, Jin Oh;Kim, Young Su;Park, Seong Woo
    • Textile Coloration and Finishing
    • /
    • v.33 no.3
    • /
    • pp.120-130
    • /
    • 2021
  • The condition of covering process using thermoplastic polyetherester elastomeric fibers(TPEE) was established. Two types of core yarn(TPEE, Spandex) and one type of effect yarn(PET) were used as materials to confirm the change in physical properties of covering yarn under various covering conditions. In addition, the effects of the treatment temperature on the elongation at break of covering yarn after heat treatment was analyzed. Through this analysis, it was confirmed that the elastic recovery of TPEE which is used as the core yarn was increased with the draw ratio, but decreases when it exceeds 1:2.5. And the elongation at break of the covering yarn could be increased by increasing the twist per meter of it. Additionally, it was confirmed that the elastic recovery of TPEE which is used as a core yarn, could be increased by applying heat treatment.