• 제목/요약/키워드: recovery current

검색결과 1,071건 처리시간 0.033초

Effects of Electrostatic Discharge Stress on Current-Voltage and Reverse Recovery Time of Fast Power Diode

  • Bouangeune, Daoheung;Choi, Sang-Sik;Cho, Deok-Ho;Shim, Kyu-Hwan;Chang, Sung-Yong;Leem, See-Jong;Choi, Chel-Jong
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제14권4호
    • /
    • pp.495-502
    • /
    • 2014
  • Fast recovery diodes (FRDs) were developed using the $p^{{+}{+}}/n^-/n^{{+}{+}}$ epitaxial layers grown by low temperature epitaxy technology. We investigated the effect of electrostatic discharge (ESD) stresses on their electrical and switching properties using current-voltage (I-V) and reverse recovery time analyses. The FRDs presented a high breakdown voltage, >450 V, and a low reverse leakage current, < $10^{-9}$ A. From the temperature dependence of thermal activation energy, the reverse leakage current was dominated by thermal generation-recombination and diffusion, respectively, at low and high temperature regions. By virtue of the abrupt junction and the Pt drive-in for the controlling of carrier lifetime, the soft reverse recovery behavior could be obtained along with a well-controlled reverse recovery time of 21.12 ns. The FRDs exhibited excellent ESD robustness with negligible degradations in the I-V and the reverse recovery characteristics up to ${\pm}5.5$ kV of HBM and ${\pm}3.5$ kV of IEC61000-4-2 shocks. Likewise, transmission line pulse (TLP) analysis reveals that the FRDs can handle the maximum peak pulse current, $I_{pp,max}$, up to 30 A in the forward mode and down to - 24 A in the reverse mode. The robust ESD property can improve the long term reliability of various power applications such as automobile and switching mode power supply.

$SF_6$아크의 절연회복특성 해석 (Analysis Of Dielectric Recovery Characteristics for $SF_6$ Gas-Blast AFC)

  • 송기동;이병윤;박경엽;박정후
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제51권6호
    • /
    • pp.273-284
    • /
    • 2002
  • In this paper, computer simulations of the physical Phenomena occurring in the arc region before and after current zero were carried out to evaluate the dielectric recovery characteristics of two types of double-flow nozzles. A commercial CFD Program "PHOENICS" is used for the simulation and the user-coded subroutines to consider the arcing phenomena were added to this program by the authors. The computed results were verified by the comparison with the test results presented by the research group of BBC. In order to investigate the state of the arc region after current zero, the simulation was carried out with four steps. They are cold gas flow analysis, steady state arc simulation, transient arc simulation before current zero, transient hot gas flow simulation after current zero. The semi-experimental arc radiation model is adapted to consider the radiation energy transport and Prandtl′s mixing length model is employed as the turbulence model. The electric field and the magnetic field were calculated with the same grid structure used for the simulation of the flow field. The streamer criterion was introduced to evaluate the dielectric recovery characteristics after current zero. Compared with the results obtained by assuming the current zero state in the former studies, it has been found that the results obtained by considering the state before current zerowere more accurate.

Laval Nozzle에 대한 $SF^6$ 아크의 열적회복특성 해석 (Analysis of Thermal Recovery Characteristics for $SF^6$ Gas-Blast Arc within Laval Nozzle)

  • 송기동;이병윤;박경엽;박정후
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제51권9호
    • /
    • pp.522-529
    • /
    • 2002
  • In this paper, computer simulations of the physical Phenomena occurring in the arc region before and after current zero were carried out to evaluate the thermal recovery characteristics of a Laval nozzle. A commercial CFD program "PHOENICS" is used for the simulation and the user-coded subroutines to consider the arcing phenomena were added to this program by the authors. The computed results were verified by the comparison with the test results presented by the research group of GE Co.(General Electric Company). In order to investigate the state of the arc region after current zero, the simulation was carried out with three steps. They are steady state arc simulation, transient arc simulation before current zero, and transient hot-gas flow simulation after current zero. The semi-experimental arc radiation model is adapted to consider the radiation energy transport and Prandtl's mixing length model is employed as the turbulence model. The electric field and the magnetic field were calculated with the same grid structure used for the simulation of the flow field. The post-arc current was calculated to evaluate the thermal recovery characteristics after current zero. Compared with the results obtained by GE Co., it has been found that the critical RRRV(ratio of rise of recovery voltage) will be determined previously by this study.his study.

자속구속형 초전도 사고전류제한기의 회복특성 (Recovery Characteristic of Flux-Lock Type SFCL)

  • 임성훈;한태희;박형민;조용선;송재주;최명호;황종선;최효상;한병성
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2006년도 추계학술대회 논문집 Vol.19
    • /
    • pp.188-189
    • /
    • 2006
  • The flux-lock type superconducting fault current limiter (SFCL) has the attractive characteristics that can adjust the current limiting level by the turns ratio and the winding direction of two coils. To apply this type SFCL into power system, the analysis for the recovery characteristics of it together with the current limiting characteristic is needed. In this paper, the experiments of the current limiting and the recovery characteristics of the flux-lock type SFCL with YBCO thin film were performed. The recovery characteristics of the flux-lock type SFCL dependent on the winding direction of two coils were analyzed through the comparison with the resistive type SFCL.

  • PDF

YBCO 박막형 초전도 한류소자의 퀜치 회복 특성에 관한 연구 (Quench recovery characteristics of YBCO thin film type superconducting fault current limiter)

  • 임성우;심정욱;김혜림;현옥배;김호민;박권배;이방욱;오일성
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 B
    • /
    • pp.711-712
    • /
    • 2006
  • For the application of superconducting fault current limiters(SFCLs) to the protection system, quench recovery characteristics of Au/YBCO thin film were investigated. The Au/YBCO thin film was designed as a SFCL element with a bi-spiral pattern. The SFCL element limited the fault current successfully. For the analysis of the recovery to superconducting state, we measured resistance variation of the SFCL element after the quench. In addition, in order to investigate the dependence of quench characteristics of SFCL on the $LN_2$ cooling condition, we measured the recovery time under a pressure of 1, 2 and 3 atm. As the results, the recovery time increased in proportion to the duration of the fault currents. In the sub-cooled condition, while the quench development was exactly the same, the recovery time was shortened as the pressure increased.

  • PDF

Improved Dual-Path Energy Recovery Circuit using a Current Source and a Voltage Source for High Resolution and Large-Sized Plasma Display Panel

  • Yi, Kang-Hyun;Moon, Gun-Woo
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2008년도 하계학술대회 논문집
    • /
    • pp.544-546
    • /
    • 2008
  • An improved dual-path energy recovery circuit (ERC) using a current source and a voltage source for plasma display panel (PDP) is proposed. The proposed ERC uses the voltage source to charge a panel and the current source to discharge the panel. Thus, the proposed circuit can make the panel charge to $V_S$ and discharge to 0V, fully and it is possible to achieve zero voltage switching (ZVS) of all switches in H-bridge inverter and zero current switching (ZCS) of all switches in the ERC. Moreover, it has less conduction and switching loss in ERC devices by the dual energy recovery paths for charging and discharging the panel. Furthermore, it has features of canceling the gas discharge current, high performance and the low cost ERC components. The operation principle and features of the proposed ERC are presented in detail and verified with 42-inch SD PDP.

  • PDF

유속계 심해계류 준비 및 유속계 회수 실패원인에 관한 고찰 (Consideration on the Preparation of Current Meters for Deep-sea Mooring and Cause of Mooring Recovery Failures)

  • 황상철
    • Ocean and Polar Research
    • /
    • 제30권2호
    • /
    • pp.207-213
    • /
    • 2008
  • An interest in deep-sea measurements has been gradually increased in association with global warming and the need for deep-sea resources development. Long-term mooring of current meters has been recently conducted primarily for these purposes. In general, current meters equipped on a mooring line are deployed and recovered for a planned period in the sea. This paper describes all the preparations for deep-sea mooring. It also reviews the possible causes of the failures of recovery, which occasionally happens in the sea.

A STATISTICAL STUDY OF MAGNETIC STORM RECOVERY PHASE: PRELIMINARY RESULTS

  • Lee, D.Y.;Hwang, J.A.;Min, K.W.;Lee, E.S.;Cho, K.S.;Kim, S.G.;Bae, S.H.
    • Journal of Astronomy and Space Sciences
    • /
    • 제18권1호
    • /
    • pp.27-32
    • /
    • 2001
  • A statistical study has been performed of the magnetic storm recovery phase using the Dst index for 102 storm events in the interval January 1996 to December 1998. In 43 cases (or 42%) out of our 102 events, the recovery phase exhibits fast recovery (kaking about 8 hours or less) at its initial stage or for the entire recovery period. Since this fast recovery can be explained by the fast charge exchange less of $O^{+}$ ions which mostly com from the ionosphere, and since a fraction of $H^{+}$ ions is of ionospheric origin as well, our statistical result supports the view that the source of ring current ions in many magnetic storms can be terrestrial.

  • PDF

Influence of Interferential Current Therapy and Laser Therapy on Functional Recovery after Total Knee Replacement

  • Oh, Seung-Keun;Kim, Yong-Nam
    • The Journal of Korean Physical Therapy
    • /
    • 제26권3호
    • /
    • pp.175-181
    • /
    • 2014
  • Purpose: The purpose of this study is to investigate the effects of interference current therapy and laser therapy on functional recovery after total knee arthroplasty by measuring the Berg balance scale and range of motion. Methods: Subjects were 30 patients who were admitted to G Hospital after total knee arthroplasty. They were randomly assigned to experimental group I in which interference current therapy was applied (n=10), experimental group II in which laser therapy was applied (n=10), or the control group (n=10). The Berg balance scale and range of motion of the subjects were measured before, after 2 weeks, and after 4 weeks of therapy. Results: There was a statistically significant change (p<0.05) in the Berg balance scale and range of motion before and after therapy intervention among the laser therapy group and the interference current therapy group. There was also a significant change between the groups in the Berg balance scale and range of motion. Tukey's post hoc comparison showed a statistically significant difference between the control group and experimental group I and between the control group and experimental group II (p<0.05). Conclusion: The application of interference current therapy and laser therapy resulted in a significant change in both the Berg balance scale and range of motion among patients with total knee arthroplasty. The findings of this study can be used as preliminary clinical data in evaluating functional recovery in patients with total knee arthroplasty in a post-clinic setting.

초전도 한류기의 회복특성에 따른 재폐로 동작 분석 (An Analysis of Recloser Operation According to Recovery Characteristics of Superconducting Fault Current Limiter)

  • 이상봉;김철환;김규호;김재철;현옥배
    • 전기학회논문지
    • /
    • 제58권5호
    • /
    • pp.905-910
    • /
    • 2009
  • For proper application and operation of a SFCL(Superconducting Fault Current Limiter) in distribution systems, the prior investigation of fundamental characteristics and its effects analysis to the systems are very important. A point of view in coordination with recloser in distribution systems, characteristic about quenching and recovering of SFCL should be studied. Especially, its detailed study of recovery characteristic is particularly important to avoid conflict between the SFCL and the recloser. In this paper, the resistive type SFCL and recloser, which used in distribution system, were implemented using EMTP/ATPDraw and MODELS language. To analyze the recovery characteristics of SFCL according to recloser operation in distribution systems, case studies have been simulated and investigated.