• Title/Summary/Keyword: record method

Search Result 1,303, Processing Time 0.024 seconds

An Enhancement of Multi-Dof Frequency Response Spectrum From Impact Hammer Testing (충격햄머 실험에서 다자유도 주파수 응답스팩트럼의 개선)

  • Ahn, Se-Jin;Jeong, Weui-Bong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11b
    • /
    • pp.623-629
    • /
    • 2002
  • The spectrum of impulse response signal from an impulse hammer testing is widely used to obtain frequency response function(FRF) of the structure. However the FRFs obtained from impact hammer testing have not only leakage errors but also finite record length errors when the record length for the signal processing is not sufficiently long. The errors cannot be removed with the conventional signal analyzer which treats the signals as if they are always steady and periodic. Since the response signals generated by the impact hammer are transient and have damping, they are undoubtedly non-periodic. It is inevitable that the signals be acquired for limited recording time, which causes the finite record length error and the leakage error. In this paper, the errors in the frequency response function of multi degree of freedom system are formulated theoretically. And the method to remove these errors is also suggested. This method is based on the optimization technique. A numerical example of 3-dof model shows the validity of the proposed method.

  • PDF

The Improvement of Multi-dof Impulse Response Spectrum by Using Optimization Technique (최적화 기법을 이용한 다자유도 충격응답스펙트럼의 오차 개선)

  • 안세진;정의봉
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.12 no.10
    • /
    • pp.792-798
    • /
    • 2002
  • The spectrum of impulse response signal from an impulse hammer testing is widely used to obtain frequency response function (FRF) of the structure. However the FRFs obtained from impact hammer testing have not only leakage errors but also finite record length errors when the record length for the signal processing is not sufficiently long. The errors cannot be removed with the conventional signal analyzer which treats the signals as if they are always steady and periodic. Since the response signals generated by the impact hammer are transient and have damping, they are undoubtedly non-periodic. It is inevitable that the signals be acquired for limited recording time, which causes the finite record length error and the leakage error. In this paper, the errors in the frequency response function of multi degree of freedom system are formulated theoretically. And the method to remove these errors is also suggested. This method is based on the optimization technique. A numerical example of 3-dof model shows the validity of the proposed method.

Effectiveness of Video-Record Method on Fundamental Nursing Skill Education - Focused on Intramuscular Injection Practice - (기본간호학 실습교육에서 비디오 녹화학습의 효과연구 - 근육주사 실습교육을 중심으로 -)

  • Yeun Eun-Ja
    • The Journal of Korean Academic Society of Nursing Education
    • /
    • v.5 no.1
    • /
    • pp.86-96
    • /
    • 1999
  • Effectiveness of the videotaped-record learning method in teaching intramuscular injection skill was investigated using an experimental research methodology. Data was collected from 57 female students attending Fundamental nursing class from two depts. of nursing in Chung-ju and Seoul. The subjects were assigned to two groups, the experimental group of 30 and the control group of 27. The independent variable was videotaped-record learning method and the dependent variable were the degree of knowledge achivement, nursing skill achivement, competence on practicing intramuscular injection skill and satisfaction about the learning method. Data was analyzed using descriptive statistics, chi-square test, t-test and Pearson's correlation coefficient with SPSS-PC program. The results were summarized as follows ; 1. There was statistically significant difference between the experimental group and control group in knowledge achievement about intramuscular injections (t=4.721, P=.000). 2. There was statistically significant difference between the experimental group and control group in nursing skill achievement(t=3.542, P=.001). 3. There was no statistically significant difference between the experimental group and control group in competence on practicing intramuscular injection skill (t=.627, P=.533). 4. There was statistically significant difference between the experimental group and control group in satisfaction about learning method(t=4.708, P=.000). 5. There was significant correlation between nursing skill achievement and knowledge achievement(r=.233, p<.05). In conclusion, this study suggests that videotaped-record learning method is an effective learning method for achieving intramuscular injection skill as a basic nursing skills. Therefore, further study with more developed research design and other fundamental nursing skill practice will be needed to investigate the effectiveness of videotaped-recored learning method.

  • PDF

New J Testing Method Using Load-COD Curve for Circumferential Through-Wall Cracked Pipes under Bending (하중-균열열림변위를 이용한 굽힘하중이 작용하는 원주방향 관통균열 배관의 새로운 J 실험법)

  • Huh Nam-Su;Kim Yun-Jae;Kim Young-Jin
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.30 no.1 s.244
    • /
    • pp.60-65
    • /
    • 2006
  • The present paper provides experimental J estimation equation for the circumferential through-wall cracked pipe under four-point bending, based on the load-crack opening displacement (COD) record. Based on the limit analysis and the kinematically admissible rigid-body rotation field, the plastic ${\eta}$-factor for the load-COD record is derived and is compared with that for the load-load line displacement record. Comparison with the J results from detailed elastic-plastic finite element (FE) analysis shows that the proposed method based on the load-COD record provides reliable J estimates even for shallow cracks, whereas the conventional approach based on the load-load line displacement record gives erroneous results for shallow cracks. Thus, the proposed J estimation method could be recommended for testing the circumferential through-wall cracked pipe, particularly with shallow cracks.

A Method of Data Hiding in a File System by Modifying Directory Information

  • Cho, Gyu-Sang
    • Journal of the Korea Society of Computer and Information
    • /
    • v.23 no.8
    • /
    • pp.85-93
    • /
    • 2018
  • In this research, it is proposed that a method to hide data by modifying directory index entry information. It consists of two methods: a directory list hiding and a file contents hiding. The directory list hiding method is to avoid the list of files from appearing in the file explorer window or the command prompt window. By modifying the file names of several index entries to make them duplicated, if the duplicated files are deleted, then the only the original file is deleted, but the modified files are retained in the MFT entry intact. So, the fact that these files are hidden is not exposed. The file contents hiding is to allocate data to be hidden on an empty index record page that is not used. If many files are made in the directory, several 4KB index records are allocated. NTFS leaves the empty index records unchanged after deleting the files. By modifying the run-list of the index record with the cluster number of the file-to-hide, the contents of the file-to-hide are hidden in the index record. By applying the proposed method to the case of hiding two files, the file lists are not exposed in the file explorer and the command prompt window, and the contents of the file-to-hide are hidden in the empty index record. It is proved that the proposed method has effectiveness and validity.

Effect of two-phase fabrication method for the optimum fit of light-polymerized record bases

  • Huh, Jung-Bo;Kang, Min-Goo;Shin, Sang-Wan;Ryu, Jae-Jun
    • The Journal of Advanced Prosthodontics
    • /
    • v.2 no.3
    • /
    • pp.102-105
    • /
    • 2010
  • PURPOSE. The aims of this study were to suggest a method of fabrication of the record base using a light-polymerized resin by applying the two-phase fabrication method for the improvement of the fit of the record base and to compare the degree of fit according to the separation site. MATERIALS AND METHODS. In the edentulous cast of maxilla, four test groups were considered. In the first, second, third, and fourth test groups (n = 12 in each group) the separation was done at 0, 5, 10, and 15 mm, respectively below the alveolar crest along the palatal plane. For the control group, the record base was made without separating the two sections. The light-body silicone material was injected into the fitting surface of the record base. It was then placed onto the cast and finger pressure was applied to stabilize it in a seated position followed by immediate placement onto the universal test device. Finally, the mass of the impression material was measured after it was removed. ANOVA was performed using the SAS program. For the post-hoc test, the Wilcoxon Rank-Sum test and the Tukey-Kramer HSD test were performed ($\alpha$ = 0.05). RESULTS. The control group and Group 3, 4 showed significant differences. The Group 3 and 4 showed significantly smaller inside gaps than the control group which was not made with the two-phase fabrication method. CONCLUSION. The two-stage polymerized technique can improve the fit of the denture base particularly when the separation was made at 10 to 15 mm from the alveolar crest.

A Study on the Dietary Intake Survey Method Using a Cameraphone (카메라폰을 이용한 식이섭취 조사방법에 대한 연구)

  • Chang, Un-Jae;Ko, Shin-Ae
    • Korean Journal of Community Nutrition
    • /
    • v.12 no.2
    • /
    • pp.198-205
    • /
    • 2007
  • This study was conducted to investigate the validity of using a cameraphone for a dietary intake survey method. The subjects were 28 female college students. After eating a standard lunch meal which consisted of plain rice, seaweed soup, bulgogi, cucumber salad, roasted anchovy and kimchi, the quantity of dietary intake, calorie intake & nutrients intake were analyzed by weighed method, diet record method and cameraphone method by dietitian with k without cameraphone analysis training. There were no significant differences in the quantity of 6 foods intake between weighted method and cameraphone method by dietitians with camera phone analysis training. However, the quantity of seaweed soup, bulgogi & cucumber salad intake analyzed by diet record method was significantly lower than the weighed method. And the quantity of seaweed soup, bulgogi, cucumber salad, roasted anchovy and kimchi intake analyzed by the cameraphone method by dietitians without cameraphone analysis training was significantly lower than the weighed method. There were no significant differences in the calorie intake and nutrients intake between the weighted method and camera phone method by dietitians with camera-phone analysis training. However, protein, calcium, iron, phosphorous, Vitamin A, Vitamin $B_2$, Vitamin E and cholesterol intake analyzed by diet record method was significantly lower than the weighed method. And fat and Vitamin $B_2$ intake analyzed by the camera phone method by dietitians without cameraphone analysis training was significantly lower than the weighed method. Therefore, this study suggests that the use of the camerephone may be a valid and convenient method fur evaluating a dietary intake survey. However, systematic and standard education is necessary about the size and volume of dishes and angle of photo for more accurate results.

Estimation based on lower record values from exponentiated Pareto distribution

  • Yoon, Sanggyeong;Cho, Youngseuk;Lee, Kyeongjun
    • Journal of the Korean Data and Information Science Society
    • /
    • v.28 no.5
    • /
    • pp.1205-1215
    • /
    • 2017
  • In this paper, we aim to estimate two scale-parameters of exponentiated Pareto distribution (EPD) based on lower record values. Record values arise naturally in many real life applications involving data relating to weather, sport, economics and life testing studies. We calculate the Bayesian estimators for the two parameters of EPD based on lower record values. The Bayes estimators of two parameters for the EPD with lower record values under the squared error loss (SEL), linex loss (LL) and entropy loss (EL) functions are provided. Lindley's approximate method is used to compute these estimators. We compare the Bayesian estimators in the sense of the bias and root mean squared estimates (RMSE).

The method of recovery for deleted record in Oracle Database (Oracle 데이터베이스의 삭제된 레코드 복구 기법)

  • Choi, Jong-Hyun;Jeong, Doo Won;Lee, Sangjin
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.23 no.5
    • /
    • pp.947-955
    • /
    • 2013
  • Most of the enterprise information is stored in the database. Therefore, in order to investigate the company's criminal behavior, forensic analysis is important for the database and delete record is a need to develop recovery techniques. This paper is explained structure of the oracle database tablespace file and analyzed system tables that stored table information. Further, we suggests a method of recovery for deleted record in oracle tablespace.

The kinematics analysis of Discus throwing (원반던지기의 운동학적 분석)

  • Kim, Jong-In;Sun, Jae-Bok
    • Korean Journal of Applied Biomechanics
    • /
    • v.13 no.2
    • /
    • pp.29-47
    • /
    • 2003
  • This study is to analyze the kinematic variables in release motion of discuss throwing. For the matter, 5 people from the national team and collegiate discuss throwing in the year 2001 were chosen as the subjects and two S-VHS video cameras set in 60frames/sec were used for recording their motions. Coordinated raw positions data through digitizing are smoothing by butter-worth 's low-pass filtering method at a cut off frequency 6.0Hz. and the direct linear transformation(DLT) method was employed to obtain 3-D position coordinates. The conclusions were as follows; 1. The better record players showed the shorter approach time in the last support phase. 2. In the displacement CG, the better record players showed the shorter displacement in medial-lateral direction, and the longer displacement in horizontal direction. In the motion, the COG showed longer displacement vertical direction. 3. The better record players showed the faster horizontal velocity than vertical velocity in the release. 4. The better record players showed to take the posture of vertical axis in the release.