• Title/Summary/Keyword: recombinant human bone morphogenetic protein-4

Search Result 42, Processing Time 0.019 seconds

Combined effects of rhBMP-2 and rhVEGF coated onto implants on osseointegration: pilot study (양극산화 임플란트 표면에 적용된 골형성단백질과 혈관내피세포성장인자가 골유착에 미치는 영향: 예비연구)

  • Huh, Jung-Bo;Yun, Mi-Jung;Jeong, Chang-Mo;Shin, Sang-Wan;Jeon, Young-Chan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.51 no.2
    • /
    • pp.82-89
    • /
    • 2013
  • Purpose: The present study is aimed to evaluate the combined effect of recombinant human bone morphogenetic protein 2 (rhBMP-2) and recombinant human vascular endothelial growth factor (rhVEGF) coated onto anodized implants on osseointeration. Materials and methods: Six New Zealand white rabbit were used in this study. Each animal received 4 implants that were either coated with rhBMP-2 and rhVEGF (Study group) or anodized implant (Control group) in both tibia. This was performed using a randomized split-mouth design. A total 24 implants were used. The implant stability quotient (ISQ) value using resonance frequency analyser and removal torque (RTQ) measurement were investigated at 2 and 8 weeks. The t-test was used for statistical analysis (${\alpha}$=.05). Results: Control and study group showed good osseointegration at 8 weeks. The ISQ and RTQ values of study group were significant compared with the control group at 8 weeks (P<.05). However, No statistical significance was observed at 2 weeks (P>.05). Conclusion: It was concluded that rhBMP-2 with rhVEGF coated onto anodized implants can induce better osseointegration at late healing period.

Effect of rhPMP-2 coated implants on alveolar ridge augmentation in dogs (성견에서 골형성단백질이 코팅된 임플란트가 치조골 증대에 미치는 영향)

  • Park, Chan-Kyung;Kim, Jong-Eun;Shin, Ju-Hee;Ryu, Jae-Jun;Huh, Jung-Bo;Shin, Sang-Wan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.48 no.3
    • /
    • pp.202-208
    • /
    • 2010
  • Purpose: This study was aimed to evaluate the effect of rhPMP-2 coated implants on alveolar ridge augmentation in dogs. Materials and methods: Six Beagle dogs were used in this study. Six 8.0 mm long anodized surface titanium implants were placed 5 mm into the mandibular alveolar ridge following 6 month of healing period after extraction. Each animal received three implants coated with rhBMP-2 and three uncoated control implants using the randomized split-mouth design. Radiographic examinations were undertaken immediately at implant placement (baseline), at weeks 4 and 8 after implant placement. The amount of bone augmentation was evaluated by measuring the distance from the uppermost point of the coverscrew to the marginal bone. Implant Stability Quotient (ISQ) values were measured immediately at implant placement and 8 weeks after implant placement. For the statistical analysis, Man-Whitney ranksum test and Wilcoxon signed rank test of SPSS 12.0 software were used (P=.05). Results: The BMP group exhibited radiographic vertical bone augmentation about $0.6{\pm}0.7$ mm at 8 weeks later while controls showed bone loss about $0.4{\pm}0.6$ mm. There was significant difference among the rhBMP-2 group and controls in bone level change (P<.05). The ISQ values were significantly higher in the BMP-2 group than the control group at 8 weeks later (P<.05), while there was no significant difference at surgery. Conclusion: Within the limitation of this study, the rhBMP-2 coated on anodized implant could stimulate vertical alveolar bone augmentation, which may increase implant stability significantly on completely healed alveolar ridge.