• Title/Summary/Keyword: recoil mechanism

Search Result 16, Processing Time 0.025 seconds

Digital Control of Automatic Gun Systems Incorporating an Intermittently Rotating Chamber (간헐 회전식 약실을 적응한 자동포 시스템의 디지털 제어)

  • Lim, S.C.;Kim, K.K.;Shim, J.S.;Kil, S.J.;Kim, H.C.;Lee, G.H.;Cha, G.U.;Cho, C.K.;Hong, S.K.
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.10 no.2
    • /
    • pp.126-133
    • /
    • 2007
  • Lately, there exist growing demands to increase the firepower of mid-calibre automatic guns despite spatial limitations of armament. In this context, ammunitions of simple cylindrical shape are considered so advantageous that associated automatic guns are under development incorporating an intermittently rotating chamber mechanism. In this paper, relevant subsystems for such guns are to be described, and a digital controller to automate the entire system as well. Via dynamic simulations it proves to function well being able to drive the chamber at any constant speed up to 200spm, which is merely limited by the recoil performance. It is remarkable that the system synchronization idea in use is applicable to any other multi-actuator systems that should operate on the basis of event rather than time.

MODELING FAILURE MECHANISM OF DESIGNED-TO-FAIL PARTICLE FUEL

  • Wongsawaeng, Doonyapong
    • Nuclear Engineering and Technology
    • /
    • v.41 no.5
    • /
    • pp.715-722
    • /
    • 2009
  • A model to predict failure of designed-to-fail (dtf) fuel particles is discussed. The dtf fuel under study consisted of a uranium oxycarbide kernel coated with a single pyrocarbon seal coat. Coating failure was assumed to be due to fission gas recoil and knockout mechanisms and direct diffusive release of fission gas from the kernel, which acted to increase pressure and stress in the pyrocarbon layer until it ruptured. Predictions of dtf fuel failure using General Atomics' particle fuel performance code for HRB-17/18 and HFR-B1 irradiation tests were reasonably accurate; however, the model could not predict the failure for COMEDIE BD-1. This was most likely due to insufficient information on reported particle fuel failure at the beginning.

High Power Laser Driven Shock Compression of Metals and Its Innovative Applications (고 출력 레이저에 의한 충격파 현상 연구 및 응용)

  • Lee, Hyun-Hee;Gwak, Min-Cheol;Choi, Ji-Hee;Yoh, Jai-Ick
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.32 no.11
    • /
    • pp.832-840
    • /
    • 2008
  • Ablation occurs at irradiance beyond $10^9\;W/cm^2$ with nanosecond and short laser pulses focused onto any materials. Phenomenologically, the surface temperature is instantaneously heated past its vaporization temperature. Before the surface layer is able to vaporize, underlying material will reach its vaporization temperature. Temperature and pressure of the underlying material are raised beyond their critical values, causing the surface to explode. The pressure over the irradiated surface from the recoil of vaporized material can be as high as $10^5\;MPa$. The interaction of high power nanosecond laser with a thin metal in air has been investigated. The nanosecond pulse laser beam in atmosphere generates intensive explosions of the materials. The explosive ejection of materials make the surrounding gas compressed, which form a shock wave that travels at several thousand meters per second. To understand the laser ablation mechanism including the heating and ionization of the metal after lasing, the temporal evolution of shock waves is captured on an ICCD camera through laser flash shadowgraphy. The expansion of shock wave in atmosphere was found to agree with the Sedov's self-similar spherical blast wave solution.

The UV Laser Ablation of Cr film on Glass Substrate (UV레이저를 이용한 Cr 박막의 어블레이션)

  • Yoon, Kyung-Ku;Lee, Seong-Kuk;Kim, Jae-Gu;Choi, Doo-Sun;Whang, Kyung-Hyun;Jung, Jae-Kyoung;Jang, Won-Suk;Na, Suck-Joo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.17 no.8
    • /
    • pp.134-139
    • /
    • 2000
  • In order to understand the removal mechanism and seek the optimal conditions. KrF excimer laser ablation of Cr films on glass substrates is investigated. The surface morphology of the laser-irradiated spot is examined by SEM. The measured single-shot ablation rate is found to be about two times the result of numerical analysis based on a surface vaporization model and heat conduction theory. Surface morphology examination indicates that the Cr film is removed by the sequence of melting-surface vaporization-,melt expulsion by plasma recoil and that the outmost ripple of the diffraction pattern gives a strong effect on the morphology of molten Cr during the melting and vaporization processes. To seek the optimal process parameters for micro patterning morphological investigation is carried out experimentally on samples having different chromium film thicknesses. Optimal processing conditions are determined to enhance the accuracy and quality of thin film removal for micro patterning.

  • PDF

Proton implantation mechanism involved in the fabrication of SOI wafer by ion-cut process (Ion-cut에 의한 SOI웨이퍼 제조에서의 양성자조사기구)

  • 우형주;최한우;김준곤;지영용
    • Journal of the Korean Vacuum Society
    • /
    • v.13 no.1
    • /
    • pp.1-8
    • /
    • 2004
  • The SOI wafer fabrication technique has been developed by using ion-cut process, based on proton implantation and wafer bonding techniques. It has been shown by TRIM simulation that 65 keV proton implantation is required for the standard SOI wafer (200 nm SOI, 400 nm BOX) fabrication. In order to investigate the optimum proton dose and primary annealing condition for wafer splitting, the surface morphologic change has been observed such as blistering and flaking. As a result, effective dose is found to be in the 6∼$9\times10^{16}$ $H^{+}/\textrm{cm}^2$ range, and the annealing at $550^{\circ}C$ for 30 minutes is expected to be optimum for wafer splitting. The depth distribution of implanted hydrogen has been experimentally confirmed by ERD and SIMS measurements. The microstructure evolution in the damaged layer was also studied by X-TEM analysis.

Correlation of Tracheal Cross-sectional Area with Parameters of Pulmonary Function in COPD (만성 폐쇄성 폐질환에서 기관의 단면적과 폐기능지표와의 상관관계)

  • Lee, Chan-Ju;Lee, Jae-Ho;Song, Jae-Woo;Yoo, Chul-Gyu;Kim, Young-Whan;Han, Sung-Koo;Shim, Young-Soo;Chung, Hee-Soon
    • Tuberculosis and Respiratory Diseases
    • /
    • v.46 no.5
    • /
    • pp.628-635
    • /
    • 1999
  • Background : Maximal expiratory flow rate is determined by the size of airway, elastic recoil pressure and the collapsibility of airway in the lung. The obstruction of expiratory flow is one of the major functional impairments of emphysema, which represents COPD. Nevertheless, expiratory narrowing of upper airway may be recruited as a mechanism for minimizing airway collapse, and maintaining lung volume and hyperinflation by an endogenous positive end-expiratory pressure in patients with airflow obstruction. We investigated the physiologic role of trachea in respiration in emphysema. Method : We included 20 patients diagnosed as emphysema by radiologic and physiologic criteria from January to August in 1997 at Seoul Municipal Boramae Hospital. Chest roentgenogram, high resolution computed tomography(HRCT), and pulmonary function tests including arterial blood gas analysis and body plethysmography were taken from each patient. Cross-sectional area of trachea was measured according to the respiratory cycle on the level of aortic arch by HRCT and calibrated with body surface area. We compared this corrected area with such parameters of pulmonary function tests as $PaCO_2$, $PaO_2$, airway resistance, lung compliance and so on. Results : Expiratory cross-sectional area of trachea had significant correlation with $PaCO_2$ (r=-0.61, p<0.05), $PaO_2$ (r=0.6, p<0.05), and minute ventilation (r=0.73, p<0.05), but inspiratory cross-sectional area did not (r=-0.22, p>0.05 with $PaCO_2$, r=0.26, p>0.05 with $PaO_2$, and r=0.44, p>0.05 with minute ventilation). Minute ventilation had significant correlation with tidal volume (r=0.45, p<0.05), but it had no significant correlation with respiratory frequency (r=-0.31, p>0.05). Cross-sectional area of trachea had no significant correlation with other parameters of pulmonary function including $FEV_1$, FVC, $FEV_1$/FVC, peak expiratory flow, residual volume, diffusing capacity, airway resistance, and lung compliance, whether the area was expiratory or inspiratory. Conclusion : Cross-sectional area of trachea narrowed during expiration in emphysema, and its expiratory area had significant correlation with $PaCO_2$, $PaO_2$, and minute ventilation.

  • PDF