• Title/Summary/Keyword: recharge.

Search Result 501, Processing Time 0.029 seconds

Estimation of the Groundwater Movement Under the Heavyrainfall at Nanji Waste Landfill (집중호우시 발생하는 난지도 매립지내의 지하수 거동)

  • 구태훈;조원철
    • Journal of Soil and Groundwater Environment
    • /
    • v.6 no.3
    • /
    • pp.107-117
    • /
    • 2001
  • The characteristics of groundwater movement under the heavy rainfall at Nan-ji waste landfill site are studied using HELP(Hydraulic Evaluation of Landfill Performance) program, which calculates the daily leachate in the Nan-ji waste landfill site. In this study, instead of the average recharge value, which is used in the past study, the real reacharge value is used to calculate the daily leachater. It is found about 70 times greater than thor average recharge value under the condition of heavy rainfall in the rainy season. The flow characteristics of groundwater for water level fluctuation is simulated using the ground water flow model MODFLOW(A Modular 3-D Finite Different Groundwater Flow Model) program, and the slurry layer is newly added. The result of the study is different from that of the ordinary simulation, which shows much higher ground water level than from the ordinary simulation.

  • PDF

Numerical Study on Behavior of Underground Freshwater Body with Variation of Freshwater Injection in a Coastal Aquifer (염수대수층 내 담수 주입 변화에 따른 지하 담수체 거동에 대한 수치모의)

  • Jeong, Woo Chang
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2015.05a
    • /
    • pp.249-249
    • /
    • 2015
  • ASR(Aquifer Storage Recharge) 또는 ASTR(Aquifer Storage Transfer Recharge)과 같은 직접적인 지하수 인공함양기법은 대수층을 활용하여 수자원을 공급하고 관리하기 위한 적극적인 방안으로 고려될 수 있다. 이 중 ASTR 기법은 대규모 충적층이 발달한 강변 또는 하구에서 저류지 수생식물의 정화작용과 층적층의 물리/화학/생물학적 여과 기능을 활용하여 양질의 상수원수를 확보할 수 있는 기법이며, 수질이 나쁜 하천수를 직접 취수하여 정수처리하는 것에 비해 정수비용이 상대적으로 적게 들어 투자대비 경제적인 상수원수 확보기술이라 할 수 있다. 본 연구에서는 하구에 염수 대수층이 위치해 있다고 가정하였으며, 이러한 염수 대수층 내에 담수 주입 변화에 따른 지하 담수체의 거동을 4가지 시나리오에 따라 모의 및 분석을 통해 조사하였다. 염수 대수층 내에서 8개의 주입정과 1개의 양수정이 설치되어 있다고 가정하였으며, 주입정은 동심원 상에 등간격으로 위치해 있으며, 양수정은 동심원 중에 위치해 있다고 가정하였다. 본 연구에서 구성된 시나리오로 첫 번째는 주입정 8개 모두에서 동시에 주입되며, 1개의 양수정을 통해 양수되는 것이며, 두 번째는 7개의 주입정에 주입 그리고 1개의 주입정 폐쇄, 세 번째는 6개 주입정에 주입 및 양수정과 서로 마주보는 2개 주입정 폐쇄, 그리고 마지막으로 6개 주입정에 주입 및 서로 이웃한 2개 주입정 폐쇄이다.

  • PDF

An Experimental Study on Denitrification Efficiency of Agricultural Byproducts for Prevention of Nitrate Contamination from LID or Groundwater Recharge Facilities (지하수 함양시설 또는 LID시설에서의 질산성질소 오염방지를 위한 농업부산물의 탈질효율 실험연구)

  • Lee, Jinwon;Phung, Thanh Huy;Lee, Byungsun;Kim, Kangjoo;Lee, Gyusang
    • Journal of Soil and Groundwater Environment
    • /
    • v.26 no.6
    • /
    • pp.82-94
    • /
    • 2021
  • Facilities for low impact development (LID) or groundwater recharge have the high potential spreading groundwater nitrate contamination because of the rapid infiltration. This study was initiated to remove nitrate from the waters using agricultural byproducts as organic sources for denitrification during infiltration. As the first step of this purpose, we experimentally tested the denitrifying efficiency of 4 organic materials (pine tree woodchips, cherry leaves, rice straws, and rice hulls) and tried to identify the key factors controlling the efficiency. For this study, we precisely investigated the change of chemical reactions during the experiment by analyzing various geochemical parameters. The result shows that the denitrification efficiency is not simply linked to the availability of the easily decomposable contents in the organic matter. It is found that avoiding the severe pH decrease due to the CO2 generation is the essence to derive the efficient denitrifying conditions when organic matters were used.

Characterization of Groundwater Quality and Recharge using Periodic Measurements of Hydrogeochemical Parameters and Environmental Tracers in Basaltic Aquifers of Jeju Island (수리지구화학적 인자와 환경 추적자의 주기적 관측에 의한 제주도 지하수의 수질과 함양 특성 분석)

  • Koh, Dong-Chan;Cheon, Su-Hyun;Park, Ki-Hwa
    • Journal of Soil and Groundwater Environment
    • /
    • v.12 no.4
    • /
    • pp.60-71
    • /
    • 2007
  • Groundwater from public wells was monitored during one year with two month interval for hydrogeochemical parameters and chlorofluorocarbons (CFCs) as environmental tracers in Jeju Island. Concentrations of major cations and $SiO_2$ show variation less than 10% whereas $NO_3$ and dissolved oxygen (DO) showed larger variation though DO variation did not change oxic or suboxic condition. $NO_3$ concentration has no consistent seasonal pattern with the largest variation of 35%. Groundwater ages determined by CFCs became temporarily younger by 5 years in October for groundwater with ages of 15 to 25 years, which can be attributed to infiltrating water in rainy season. Compared to air temperature, groundwater temperature has much smaller variation with no phase difference, which can be accounted for by a two-component model consisting of infiltrating water from surface and deeper groundwater with negligible temperature variation. The relatively small variation in groundwater age and temperature indicates that groundwater recharge through fast flow-paths is much smaller compared with basal groundwater in terms of aquifer storage.

Groundwater Flow Model of Igsan Area (익산 지역의 지하수 유동 모델)

  • Hamm, Se Yeong;Kim, Youn Ki
    • Economic and Environmental Geology
    • /
    • v.22 no.4
    • /
    • pp.381-393
    • /
    • 1989
  • Hydrogeological modelling was performed to evaluate groundwater flow system in Igsan Area. The study area extends over $790km^2$. The geology consists of Jurassic Daebo granite and gneissose granite and Precambrian metamorphic rocks. The capability of pumping yield is the highest in gneissose granite region among them due to comparatively thick weathered zone with thickness ranging from 10m to 25m. The Colorado State University Finite Difference Model was used for the model simulation. The model was divided into 28 rows and 31 columns with variable grid spacing. The model was calibrated under steady-state and unsteady-state conditions. In the steady-state simulation, the model results were compared with measured water table contours in September 1985 with determining hydraulic conductivities and net recharge rates during rainy season. Unsteady state simulation was done to know the aquifer response due to groundwater abstraction. The non- steady state calibration was conducted to determine the distribution and magnitudes of specific yields and discharge/recharge rates during dry season as matching water level altitudes in May 1986. The calibrated model was used to simulate water level vaiation caused by groundwater withdrawal and natural recharge from 1 October, 1985 until 30 September, 1995. The calibrated model can be used to groundwater development schemes on regional groundwater levels, but it cannot be used to simulate local groundwater level change at a specific site.

  • PDF

Numerical Modeling of Water Transfer among Precipitation, Surface Water, Soil Moisture and Groundwater

  • Chen, Xi;Zhang, Zhicai;Chen, Yongqin
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2006.05a
    • /
    • pp.2-11
    • /
    • 2006
  • In the processes of hydrological cycle, when precipitation reaches the ground surface, water may become surface runoff or infiltrate into soil and then possibly further percolate into groundwater aquifer. A part of the water is returned to the atmosphere through evaporation and transpiration. Soil moisture dynamics driven climate fluctuations plays a key role in the simulation of water transfer among ground surface, unsaturated zone and aquifer. In this study, a one-layer canopy and a four-layer soil representation is used for a coupled soil-vegetation modeling scheme. A non-zero hydraulic diffusivity between the deepest soil layer modeled and groundwater table is used to couple the numerical equations of soil moisture and groundwater dynamics. Simulation of runoff generation is based on the mechanism of both infiltration excess overland flow and saturation overland flow nested in a numerical model of soil moisture dynamics. Thus, a comprehensive hydrological model integrating canopy, soil zone and aquifer has been developed to evaluate water resources in the plain region of Huaihe River basin in East China and simulate water transfer among precipitation, surface water, soil moisture and groundwater. The newly developed model is capable of calculating hydrological components of surface runoff, evapotranpiration from soil and aquifer, and groundwater recharge from precipitation and discharge into rivers. Regional parameterization is made by using two approaches. One is to determine most parameters representing specific physical values on the basis of characterization of soil properties in unsaturated zone and aquifer, and vegetations. The other is to calibrate the remaining few parameters on the basis of comparison between measured and simulated streamflow and groundwater tables. The integrated modeling system was successfully used in the Linhuanji catchment of Huaihe plain region. Study results demonstrate that (1) on the average 14.2% of precipitation becomes surface runoff and baseflow during a ten-year period from 1986 to 1995 and this figure fluctuates between only 3.0% in drought years of 1986, 1988, 1993 and 1994 to 24.0% in wet year of 1991; (2) groundwater directly deriving from precipitation recharge is about 15.0% t of the precipitation amount, and (3) about half of the groundwater recharge flows into rivers and loses through evaporation.

  • PDF

Analysis of Hydrological Processes for Musim River Basin by Using Integrated Surface water and Groundwater Model (지표수-지하수 통합모형을 이용한 무심천 유역의 수문과정 해석)

  • Kim, Nam-Won;Chung, Il-Moon;Lee, Jeong-Woo;Won, Yoo-Seung
    • Journal of Korea Water Resources Association
    • /
    • v.40 no.5
    • /
    • pp.419-430
    • /
    • 2007
  • Integrated modelling of surface water and groundwater has become important to satisfy the growing demands for sustainable water resources and improved water quality. In this study, the integrated model of the semi-distributed watershed model, SWA T and the fully-distributed groundwater flow model, MODFLOW is applied to Musirn river basin for the purpose of investigating its applicability to reproduce watershed-scale hydrological processes. This objective is accomplished by first demonstrating good agreement between the simulated discharge hydrographs with the measured hydrographs for the period of 2001 -2004 while simultaneously calibrating the calculated groundwater level distribution to observation wells. Next, the integrated model is used to evaluate the effect of different temporal precipitation averages on hydrodynamic processes of streamflow, percolation, recharge and groundwater discharge. Moreover, comprehensive simulations are performed to present the relationships between monthly precipitation and each hydrological component, and to analyze the temporal-spatial variability of recharge. The results show that the components are highly interrelated, and that the heterogeneity of watershed characteristics such as subbasin slope, land use, soil type causes a significant spatial variation of recharge. Overall it is concluded that the model is capable of reproducing the temporally and spatially varied surface and subsurface hydrological processes at the watershed scale.

Geochemical Analysis and Fates of Pathogenic Indicating Bacteria on Seawater Intrusion in a Sand Box Model (인공 대수층내에서 발생하는 해수침투의 지화학적 분석 및 병원성 지표 미생물의 사멸 특성)

  • Lee, So-Jung;Park, Hun-Ju;Sung, Eun-Hae;So, Myung-Ho;Kim, Chang-Gyun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.30 no.4
    • /
    • pp.385-392
    • /
    • 2008
  • In this study, seawater intrusion was assessed employing a kind of biological parameters such as Escherichia coli and Enterococcus faecalis while lab-prepared reclaimed water was recharged to prevent seawater intrusion. Chemical factors indicating seawater intrusion such as Cl$^-$, Ca$^{2+}$, Mg$^{2+}$ and specific conductivity were also simultaneously investigated where an ion exchange between a matrix in artificial aquifer and cations in solution was estimated. Both Escherichia coli and Enterococcus faecalis were shown to be very sensitive against degree of salinity during saline water intrusion. Enterococcus faecalis more strongly resisted against salinity than that of Escherichia coli. The ratio of Enterococcus faecalis divided by E. coli in the process of seawater intrusion increased up to more than 50$\sim$100 times in 18 hours whereas E. coli was died off more than 90% during pumping and recharge rate kept at 10 mL/min. However, when the rates of both recharge and pumping was kept at 5 mL/min, Enterococcus faecalis / Escherichia coli was sustained in the range of 2.5$\sim$5.0, while Escherichia coli showed dimished death rate. Chemical factors such as Cl$^-$, Ca$^{2+}$, Mg$^{2+}$ and specific conductivity showed more than 0.9 of high correlation each other well explaining the degree of seawater intrusion. The degree of ion exchange between artificial aquifer and saline water can be efficiently interpreted by both minus $\Delta$Na, $\Delta$Mg variation and positive $\Delta$Ca variation.

Analyses of Hydrology and Groundwater Level Fluctuation in Granite Aquifer with Tunnel Excavation (터널 굴착에 의한 화강암 대수층의 수리 수문 및 지하수위변동 분석)

  • Chung, Sang-Yong;Kim, Byung-Woo;Kang, Dong-Hwan;Shim, Byoung-Ohan;Cheong, Sang-Won
    • The Journal of Engineering Geology
    • /
    • v.17 no.4
    • /
    • pp.643-653
    • /
    • 2007
  • Average hydraulic conductivity was $2.64{\times}10^{-8}m/sec$ average RQD was 78%, average porosity was 0.51%, and range of groundwater level was $77.06{\sim}125.97m$ by measured in 8 boreholes at the Surak Mt. tunnel area. Groundwater level of two peaks in the Surak Mt. tunnel area were estimated through linear regression analysis for groundwater level versus elevation. And, average horizontal hydraulic gradient in the Surak Mt. tunnel area was calculated 0.267. Minimum, maximum, and average hydraulic conductivities that estimated by field tests were $5.56{\times}10^{-9}m/sec,\;6.12{\times}10^{-8}m/sec,\;and\;2.64{\times}10^{-8}m/sec$, respectively. Groundwater discharge rates per 1 meter that estimated using minimum, maximum, and average hydraulic conductivities and average horizontal hydraulic gradient were $0.00585m^2/day,\;0.06434m^2/day,\;and\;0.02775m^2/day$, respectively. Pure groundwater recharge rate per unit recharge area was calculated 223.96 mm/yr through water balance analysis. Prediction simulation of groundwater level fluctuation with minimum, maximum, and average hydraulic conductivities were conducted. Discharge rate into the Surak Mt. tunnel for minimum hydraulic conductivity was small, but groundwaer drawdown was highly. Discharge rate into the Surak Mt. tunnel for maximum hydraulic conductivity was higher, but groundwaer level was recovered quickly.

Analysis of Groundwater Use in Kap-cheon Basin (갑천 유역의 지하수 이용 특성 분석)

  • Hong, Sung-Hun;Kim, Jeong-Kon
    • Journal of Korea Water Resources Association
    • /
    • v.41 no.5
    • /
    • pp.463-471
    • /
    • 2008
  • The purpose of this study is to analyze the features of groundwater use to utilize as basic information for water-cycle analysis system development and effective groundwater management in the Kap-cheon basin. The cumulative relationship between groundwater use and the number of wells was analyzed to estimate the representative total groundwater use and the number of wells for the Kap-cheon basin. Then, the spatial distribution of groundwater use in the basin were figured out using the detailed information on groundwater use in each well. Finally, the reasonability of groundwater resources management in Kap-cheon basin was evaluated by comparing groundwater recharge and groundwater use in sub-basins and major stream basins. The results of the analysis showed about 25% of the total wells could represent 90% of groundwater use ($37,923,516\;m^3$/year) in the Kap-cheon basin. A detailed analysis on the groundwater uses in the vicinity of down-town areas of Daejeon metropolitan city showed high groundwater uses ($1.4{\sim}11.1$ times) compared to the groundwater recharge previously estimated using the rainfall-runoff model. The ratio of groundwater use and groundwater recharge for the major river basins in Kap-cheon basin ranged from 1.9 to 2.3 indicating that more sustainable groundwater management should be exercised. The results of this study can be used as basic information in evaluating the change of groundwater flow, stream flow and water-cycle for various groundwater uses in the Kap-cheon basin.