• Title/Summary/Keyword: reattachment

Search Result 310, Processing Time 0.024 seconds

A Study of Applicability of a RNG $k-\varepsilon$ Model (RNG $k-\varepsilon$ 모델의 적용성에 대한 연구)

  • Yang, Hei-Cheon;Ryou, Hong-Sun;Lim, Jong-Han
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.21 no.9
    • /
    • pp.1149-1164
    • /
    • 1997
  • In this study, the applicability of the RNG k-.epsilon. model to the analysis of the complex flows is studied. The governing equations based on a non-orthogonal coordinate formulation with Cartesian velocity components are used and discretized by the finite volume method with non-staggered variable arrangements. The predicted results using the RNG k-.epsilon. model of three complex flows, i.e., the flow over a backward-facing step and a blunt flat plate, the flow around a 2D model car are compared to these from the standard k-.epsilon. model and experimental data. That of the unsteady axisymmetric turbulent flow within a cylinder of reciprocating model engine including port/valve assembly and the spray characteristics within a chamber of direct injection model engine are compared to these from the standard k-.epsilon. model and experimental data. The results of reattachment length, separated eddy size, average surface pressure distribution using the RNG k-.epsilon. model show more reasonable trends comparing with the experimental data than those using the modified k-.epsilon. model. Although the predicted rms velocity using the modified k-.epsilon. model is lower considerably than the experimental data in incylinder flow with poppet valve, predicted axial and radial velocity distributions at the valve exit and in-cylinder region show good agreements with the experimental data. The spray tip penetration predicted using the RNG k-.epsilon. model is more close to the experimental data than that using the modified k-.epsilon. model. The application of the RNG k-.epsilon. model seems to have some potential for the simulations of the unsteady turbulent flow within a port/valve-cylinder assembly and the spray characteristics over the modified k-.epsilon. model.

Flow Structure Around a Rectangular Prism Placed in a Thick Turbulent Boundary Layer (두꺼운 난류경계층 내부에 놓인 직사각형 프리즘 주위의 유동구조)

  • Kim, Gyeong-Cheon;Ji, Ho-Seong;Chu, Jae-Min;Lee, Seok-Ho;Seong, Seung-Hak
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.26 no.4
    • /
    • pp.578-586
    • /
    • 2002
  • Flow structures around a rectangular prism have been investigated by using a PIV(Particle Image Velocimetry) technique. A thick turbulent boundary layer was generated by using spires arid roughness elements. The boundary layer thickness, displacement thickness and momentum thickness were 650mm, 117.4mm and 78mm, respectively. The ratio between the model height(40mm) and the boundary layer thickness H/$\delta$, was 0.06. The Reynolds number based on the free stream velocity and the height of the model was 7.9$\times$10$^3$. The PIV measurements were performed at three different wall normal planes. Three recirculation regions at forward facing step, top of the roof and backward facing step are clearly seen and show three dimensional features. Dramatic changes of flow patterns are observed in the wake regions in the different spanwise wall normal planes. Instead of reattachment and recirculation zone, rising streamlines are depicted at the normal planes near the side wall due to the interaction with a rising horse shoe vortex. The peak of turbulent kinetic energy occurs at the separation bubble on top of the roof and the magnitude is 2.5 times higher compared with that of the wake region.

Fluid flow and heat transfer around tubes arranged in line (일행관군에서의 유동특성과 열전달현상에 관한 연구)

  • 부정숙;조석호;정규하
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.14 no.6
    • /
    • pp.1603-1612
    • /
    • 1990
  • An experimental study is conducted to investigate the fluid flow and heat transfer around tubes arranged in line. All measurements are performed at Reynolds number 1.58*10$^{4}$ with varing tube spacings from the small pitch ratio(L/D=1.25) to the large pitch ratio(L/D=3.0). Mean static pressures and mean temperatures of the surface of tubes and mean velocities and turbulent intensities in tube banks are measured. The flow patterns and the characteristics of heat transfer are strongly influenced by the tube spacings. Especially, in the case of very small spacings(L/D=1.25), the flow between neighboring tubes becomes very stagnant and the heat transfer decreases. In the case of each tube spacing, the characteristics of heat transfer around the 3rd, the 4th and the 5th tubes are nearly similar to one another, because the flow around tubes becomes stable at the 3rd tubes. The local heat transfer has the peak value near the reattachment point which has the peak value of pressure, but the local heat transfer for the 2nd tube of L/D=1.25 without reattaching has the peak value at .theta.=75.deg.. For each pitch ratio, the mean heat transfer increases gradually toward the downstream tubes, because the oncoming flow through neighboring tubes comes closer to the forward and rear surfaces of the tube and the turbulent intensity becomes larger in the downstream direction.

Experimental Study of Heat/Mass Transfer in Rotating Cooling Passages with Discrete Ribs (단락 요철이 설치된 내부 냉각유로에서 회전에 따른 열/물질전달 특성 연구)

  • Kim Kyung Min;Kim Sang In;Lee Dong Ho;Cho Hyung Hee
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.29 no.5 s.236
    • /
    • pp.590-598
    • /
    • 2005
  • The present study has been conducted to investigate the effect of discrete ribs and rotation on heat/mass transfer characteristics in a two-pass square duct with $90^{\circ}-rib$ turbulators. The rib turbulator has a square cross section of 1.5 mm. The rib height-to-hydraulic diameter ratio $({e/D_{h})$ is 0.056, and the rib pitch-to-rib height ratio (p/e) is 10. The gap width is the same as the rib height. The rotation number ranges from 0.0 to 0.2 while Reynolds number is fixed to 10,000. In a stationary duct, the heat/mass transfer on the surfaces with discrete ribs is enhanced because the gap flow promotes local turbulence and flow mixing near the ribbed surface. In a rotating duct, the gap flow affects differently the heat/mass transfer on leading and trailing surfaces with discrete ribs. On the leading surface of the first pass, heat/mass transfer is increased due to the gap flow. On the trailing surface of the first pass, however, heat/mass transfer is decreased because the gap flow disturbs reattachment of main flow. The phenomenon, that is, the difference of heat transfer between the leading and the trailing surfaces is distinctly presented by rotation.

Open reduction of zygoma fractures with the extended transconjunctival approach and T-bar screw reduction

  • Song, Seung Han;Kwon, Hyeokjae;Oh, Sang-Ha;Kim, Sun-Je;Park, Jaebeom;Kim, Su Il
    • Archives of Plastic Surgery
    • /
    • v.45 no.4
    • /
    • pp.325-332
    • /
    • 2018
  • Background Zygomaticomaxillary complex (ZMC) fractures mostly occur in the form of tripod fractures. The surgical field is accessed using a combination of three classic approaches. However, the subciliary incision may have unfavorable aesthetic results. Herein, the authors report the advantages of the extended transconjunctival approach (ETA) combined with T-bar screw reduction in minimizing scarring and complications for the treatment of ZMC fractures. Methods A total of 26 patients underwent ZMC reduction through the ETA and intraoral approach. A skin incision measuring roughly 5 to 8 mm in length was placed following the lateral canthal skin crease. After releasing the inferior crus of the lateral canthal tendon for canthotomy, the medial periosteum of the lateral orbital rim was preserved for canthal reattachment. A limited subperiosteal dissection and partial relaxing incision of the orbicularis oculi were performed to expose the fracture line of the inferior orbital rim and zygomaticofrontal suture. Reduction was performed using a T-bar screw through the transconjunctival incision and an elevator through the intraoral incision. Results The aesthetic and functional results were excellent. Successful reduction was achieved and the skin incision was less than 8 mm in 20 cases (76.9%). Only six patients had an additional skin incision (less than 5 mm) to achieve reduction. No cases of ectropion, entropion, or excessive scarring were noted. Conclusions The ETA using a T-bar screw is a useful method for maximizing aesthetic results in ZMC fractures, with the advantages of minimal scarring, faster recovery, and maintenance of pretarsal fullness.

THE EXPERIMENTAL STUDY FOR INFLUENCE OF FIBRIN GLUE DURING HEALING PHASE AFTER MAKING ARTIFICIAL BONE DEFECT (백서 두개골 결손부의 골재생에 fibrin glue가 미치는 영향에 관한 실험적 연구)

  • Rim, Jae-Suk;Jang, Hyon-Seok;Eune, Jung-Ju;Lee, Eui-Seok;Park, Eun-Yong;Suh, Je-Duck
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.27 no.5
    • /
    • pp.431-437
    • /
    • 2005
  • Fibrin glue is composed of fibrinogen and thrombin and used in various regions for multiple use. Basic principle is that thrombin converts fibrinogen to fibrin in the presence of $Ca^{2+}$. The structure of fibrin is loose at the beginning, but after about 5 minutes a tight structure is formed under the influence of factor VIII which changes fibrin monomer into fibrin polymer. Fibrin glue is used for tissue adhesive, suture, local hemostasis, wound healing, closure of subdural space. Fibrin adhesive has been used in oral and maxillofacial surgery for hemostasis after tooth extraction in patients with coagulation disorders, skin graft fixation, reattachment of periodontal flaps, in combination with autogenous bone chips to fill the bony cavities following cyst removal, and for securing the hydroxyapatite granules for maxillary alveolar ridge augmentation. This study was designed for researching influence of fibrin glue during healing phase after making artificial bone defect.

An Experimental Study of Local Mass Transfer Characteristics on Inclined Flat Plate (경사진 평판에서의 국소물질전달 특성에 관한 실험적 연구)

  • Yoo, Seong-Yeon;Jo, Woo-Sik;Cho, Woong-Sun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.12
    • /
    • pp.1335-1341
    • /
    • 2011
  • The purpose of this research is to investigate how separated and reattached flow affects mass transfer, by comparing the local mass transfer characteristics on an inclined flat plate with those on a parallel flat plate. The local mass transfer coefficients for the flat plate were measured using the naphthalene sublimation technique; the inclined angle of the flat plate was varied from $-10^{\circ}$ to $10^{\circ}$ at $5^{\circ}$ intervals, and the free-stream velocity was varied from 2m/s to 15m/s. At positive inclined angles, the local Sherwood numbers decreased gradually because the boundary-layer thickness increased. On the other hand, for negative inclined angles, the local Sherwood numbers assumed the minimum value at the separation point of the recirculation flow and the maximum value at the reattachment point. The average Sherwood numbers for both positive and negative inclined angles were lower than those in the case of the parallel plate.

Measurement of the Film Cooling Effectiveness on a Flat Plate using Pressure Sensitive Paint (압력감응페인트를 이용한 평판에서의 막냉각 계수 측정)

  • Park, Seoung-Duck;Lee, Ki-Seon;Kim, Hark-Bong;Kwak, Jae-Su;Kim, Jae-Hwan
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.12 no.5
    • /
    • pp.67-72
    • /
    • 2008
  • The film cooling effectiveness on a flat plate measured by pressure sensitive paint technique. Six film cooling hole were fabricated on a flat plate with 30 degree angle with respect to the surface and three blowing ratios of 0.5, 1, and 2 were tested. Results showed that PSP technique successfully evaluated the distribution of film cooling effectiveness and showed similar results with references. The film cooling effectiveness near the film cooling holes was higher for lower blowing ratio case. As the blowing ratio was increased, the film cooling effectiveness near the film cooling hole decreased due to the lift off of the coolant. At far downstream, the film cooling effectiveness for higher blowing ratio was higher due to the coolant reattachment.

Surgical Treatment of Symptomatic Accessory Navicular in Adolescent (증상이 있는 청소년기 부주상골의 수술적 치료)

  • Kim, Jong-Min;Jung, Sung-Hoon;Park, Byeong-Mun;Moon, Chan-Sam;Lee, Kil-Hyeong
    • Journal of Korean Foot and Ankle Society
    • /
    • v.14 no.1
    • /
    • pp.36-40
    • /
    • 2010
  • Purpose: To investigate the results of surgical treatment of the symptomatic accessory navicular in adolescent. Materials and Methods: 11 patients who were 11-16 years old with symptomatic accessory navicular were identified between 2001 and 2009. Six cases were diagnosed after trauma and 8 cases were diagnosed by accident with painful bony protrusion on medial aspect of foot. In cases after at least 3 months of ineffective conservative treatment, patients were treated by resection of accessory navicular and reattachment of tibialis posterior tendon to the apex of the medial longitudinal arch using periosteum and ligamentous soft tissue without transposition of its course. And then short leg cast was applied for correction of the flat foot (if it is combined) which was molded into the longitudinal arch with the talonavicular joint released and foot inverted during about 6 weeks. Results: All were type II accessory navicular without tibialis posterior tendon lesions. In most cases pain was improved, results were excellent in seven and good in four. Calcaneal pitch angle and talus-first metatarsal angle was improved about $4.64^{\circ}$ and $5.79^{\circ}$ in average. Conclusion: Symptomatic accessory navicular in adolescent might not be associated with the tibialis posterior tendon lesions. The surgical treatment composed of excision of the accessory navicular with simple replication of the tibialis posterior tendon without altering its course led to good results in most cases. The procedure has a low rate of complications. And it is easy to be performed with a good satisfaction.

Use of an Interposition Tube Graft for the Reattachment of Left Coronary Ostium to the Aortic Composite Valve Graft. -One Case- (Aortic Composite Valve Graft의 이식시 인조혈관을 이용한 좌 관상동맥의 문합술 1례 보고)

  • Kim, Chang-Nam;Choe, Jong-Beom;Choe, Hyeong-Ho
    • Journal of Chest Surgery
    • /
    • v.29 no.6
    • /
    • pp.646-650
    • /
    • 1996
  • The usual methods for the re-attachment of coronary ostia to the ascending aortic conduit have several disadvantages and potential complications. A novel, straight forward technique is described that allows for tension free anastomoses to be co structed with minimal risk of blood loss and a reduced risk of reoperation for false aneurysms at the anastomoses. We performed this technique for the treatment of a 40-yrs-old male patient of acute aortic dissection (Stanford Type A, DeBakey Type I) with severe aortic re- gurgitation. The techinque comprised anastomosis of a beveled interposition tube graft to the left main coronary artery ostium, and its proximal anastomosis to the ascending aortic graft after seating the com- posite valve graft in the prepared aortic annulus. With this technique, the low-Iying or distant left main coronary ostium can be easily reattached to the ascending conduit without undue tension.

  • PDF