The signal interpretion of PD on DS for GIS (GIS 단로기의 부분방전 신호해석)

  • Kim, Jong-Seo;Park, Yong-Pil;Lee, Eun-Suk;Jeong, Seung-Cheon;Lim, Young-Bae
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.04a
    • /
    • pp.1-4
    • /
    • 2004
  • Recently, because GIS equipment has problems on confidence according to long-time usage, development of diagnosis technique has been importantly recognized. Therefore. measurement and analysis of PD has been generally used much equipment of GIS. But, in case of measurement of PD at field, real trouble signals are difficult to classify noise. Accordingly, a variety of trouble conditions for DS were simulated, and detected signals were analyzed by the application of electrical and mechanical methods. For this anslysis, detected signals were accumulated according to phase-magnitude with the application of Induction sensor, and then we analyzed the characteristics. For the simulation experiment, we made DS for 170kV GIS and analyzed the characteristics of detected singals with the application of neural network algorithm.

  • PDF

A Study on Position Detection System of KHST (고속열차의 위치검지시스템에 관한 연구)

  • Han, Young-Jae;Park, Choon-Soo;Lee, Tae-Hyung;Kim, Ki-Hwan;Lee, Jun-Seok
    • Proceedings of the KIEE Conference
    • /
    • 2007.11a
    • /
    • pp.204-205
    • /
    • 2007
  • We have developed a new measurement system by using GPS to complement those errors. In general, GPS receivers are composed of an antenna, tuned to the frequencies transmitted by the satellites, receiver-processors, and a highly-stable clock. The GPS mounted on the roof of TT4 in KHST receives a signal from the RS232 communication port, and it is connected to the network system in TT3 after converting with TCPIP communication. It is able to track the position of vehicle and synchronize the signal from different measurement system simultaneously. Therefore it is able to chase the fault occurrence, track inspection and electrical interruptionat real-time situation more accurately. There is not an error coursed by vehicle conditions such as slip and the slide.

  • PDF

Optimal Traffic Signal Control Using an Efficient Dynamic Programming (효율적인 동적계획법을 이용한 최적 교통 신호제어)

  • Park, Yun-Sun;Kim, Chang-Ouk
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.26 no.4
    • /
    • pp.315-324
    • /
    • 2000
  • This paper presents an efficient dynamic programming(DP) method, so called EDPAS (Efficient Dynamic Programming Algorithm for Signal), for optimally controlling traffic signal in real-time mode at a single intersection. The objective of EDPAS is to minimize total vehicle delay. It applies reaching method to solve forward DP functional equation, which does not need any priori knowledge on the states of DP network. Two acceleration techniques within reaching method are the main feature of EDPAS. They are devised to eliminate inferior DP states by comparing between states and maintaining incumbent value, resulting in a great amount of computational efficiency. An example is shown to verify the advantage of EDPAS.

  • PDF

Dynamic model and simulation of microturbine generation system for islanding mode operation (마이크로터빈발전시스템 독립운전을 위한 동적 모델링 및 시뮬레이션)

  • Hong, Won-Pyo;Cho, Jea-Hoon
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.05a
    • /
    • pp.453-457
    • /
    • 2009
  • Distributed Generation (DG) is predicted to play a important role in electric power system in the near future. insertion of DG system into existing distribution network has great impact on real-time system operation and planning. It is widely accepted that micro turbine generation (MTG) systems are currently attracting lot of attention to meet customers need in the distributed power generation market. In order to investigate the performance of MT generation systems, their efficient modeling is required. This paper presents the modeling and simulation of a MT generation system suitable for isolated operation. The system comprises of a Permanent magnet synchronous generator driven by a MT. A brief description of the overall system is given, and mathematical models for the MT and permanent magnet synchronous generator are presented. Also, the use of power electronics in conditioning the power output of the generating system is demonstrated. Simulation studies with MATLAB/Simulink have been carried out in islanding operation mode of a DG system.

  • PDF

A study on School Assets Management System based on Ubiquitous Sensor Network (유비쿼터스 센서네트워크를 활용한 학교자산관리시스템)

  • Park, Min-Sik;Jeon, Tae-Hyun
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.05a
    • /
    • pp.277-280
    • /
    • 2009
  • In this paper, the method to apply the RFID technology to schools will be presented in order to effectively integrate and manage various assets in school. The proposed system may be seemed to be very useful of individual school to grasp the status of their assets and also the central government to control and manage the assets scattered far and wide around the country. We also propose the OSN/PMS server based on EPC global standard could be appropriate especially in schools. In addition the proposed system can acquire simultaneously the information from several RFID readers at real time so that it is possible and easy to track the position, the path of moving and the status of assets in the school. To show the usefulness of the proposed system, the prototype of the system has been implemented and conducted. The proposed system seems to be applicable to various fields such as factories, farms, or homes as well as school.

  • PDF

Real-time Lossless Compression of Traffic for Network Forensics (네트워크 포렌직을 위한 트래픽의 실시간 비손실 압축에 관한 연구)

  • 유상현;김기창
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2004.10a
    • /
    • pp.382-384
    • /
    • 2004
  • 최근 가파른 증가세를 보이며 그 기법 또한 다양해지고 있는 공격에 대한 사후처리와 동일 침입 방지를 위해, 네트워크 포렌직에 대한 관심이 커지고 있다. 포렌직을 위해서는 정보의 손실 없는 네트워크 트래픽을 수집하여 보존하는 것이 필요하지만, 그 양이 막대하며, 이는 더 큰 용량의 디스크를 필요로 한다. 이를 해결하기 위해서는 압축을 수행하는 것이 필요하며, 또한 IP와 같이 필요로 하는 몇몇 정보를 압축해제 없이 접근할 수 있게 한다면, 간단한 작업을 위해서도 압축을 풀기 위해 컴퓨팅 파워와 시간을 줄일 수 있을 것이다. 따라서, 이 논문에서는 수집한 패킷마다 압축을 수행할 부분과 수행하지 않을 부분으로 나누고, 압축을 수행한 뒤, 해당 정보를 4바이트의 헤더로 만들어 덧붙임으로써, 기존 트래픽을 압축함과 동시에 패킷들에 대한 간단한 정보들을 압축해제 없이 접근할 수 있는 모델을 제안하였다.

  • PDF

A Development of Smart Monitoring Technique for Photovoltaic Power Systems (태양광 발전 시스템의 스마트 모니터링 기술개발)

  • Cho, Hyun Cheol;Sim, Kwang Yeal
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.64 no.2
    • /
    • pp.50-56
    • /
    • 2015
  • This paper presents a smart monitoring technique for photovoltaic power systems by using wire and wireless communication networks in which the RS-232/484 and the Zigbee communication networks are inherently established respectively. In the proposed monitoring systems, environmental data sequences and the output power measured by sensors in photovoltaic systems are transferred to PC systems via two communication networks. We made electronic hardware boards for sensors and communication networks to construct its real-time monitoring system and carry out experiments for demonstrating reliability of the proposed monitoring system.

The diagnosis of internal trouble on DS for GIS using PD detection (부분방전 검출을 이용한 GIS 단로기 내부이상 진단)

  • Kim, Jong-Seo;Lee, Eun-Suk;Cheon, Jong-Cheol
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.575-578
    • /
    • 2003
  • Recently, because GIS equipment has problems on confidence according to long-time usage, development of diagnosis technique has been importantly recognized. Therefore. measurement and analysis of PD has been generally used much equipment of GIS. But, in case of measurement of PD at field, real trouble signals are difficult to classify noise. Accordingly, a variety of trouble conditions for DS were simulated, and detected signals were analyzed by the application of electrical and mechanical methods. For this analysis, detected signals were accumulated according to phase-magnitude with the application of Induction sensor, and then we analyzed the characteristics. For the simulation experiment, we made DS for 170kV GIS and analyzed the characteristics of detected singals with the application of neural network algorithm.

  • PDF

A New Approach of Intensity Predictio in Copper Electroplating Monitoring Using Hybrid HSMM and ANN

  • Wang, Li;Hwan, Ahn-Jong;Lee, Ho-Jae;Hong, Sang-Jeen
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.02a
    • /
    • pp.137-137
    • /
    • 2010
  • Copper electroplating is a very popular and important technology for depositing high-quality conductor interconnections, especially in through silicon via (TSV). As this advanced packaging technique developing, a mass of copper and chemical solution are used, so attention to these chemical materials into the utilization and costs can not be ignored. An economical and practical real-time chemical solution monitoring has not been achieved yet. Either Red-green-blue (RGB) or optical emission spectroscopy (OES) color sensor can successfully monitor the color condition of solution during the process. The reaction rate, uniformity and quality can map onto the color changing. Hidden Semi Markov model (HSMM) can establish mapping from the color change to upper indicators, and artificial neural network (ANN) can be integrated to comprehensively determine its targets, whether the solution inside the container can continue to use.

  • PDF

Development of an Integrated Control and Monitoring System for Emergency Power Generators (비상발전기 통합제어 및 감시시스템 개발)

  • 진강규;류길수;윤지근;유성호;김재환
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2001.05a
    • /
    • pp.192-196
    • /
    • 2001
  • These days, most of electric power facilities need high stability. Therefore integrated system has been required to monitor and control electronic power distribution system in fields at all times when the interruption of electric power has occurred. To construct this system, unit that convert and process the input signal from fields needed. And for control and monitoring from remote place MMI software is required. Lastly network equipments are required for real-time communications. So, in this paper, units for control and monitoring of emergency power generator and for electric power monitoring in normal electric power and interruption of electric power are developed. Also integrated remote system for monitoring in remote is developed.

  • PDF