• 제목/요약/키워드: real-time health monitoring system

검색결과 263건 처리시간 0.024초

Recent Advances in Structural Health Monitoring

  • Feng, Maria Q.
    • 비파괴검사학회지
    • /
    • 제27권6호
    • /
    • pp.483-500
    • /
    • 2007
  • Emerging sensor-based structural health monitoring (SHM) technology can play an important role in inspecting and securing the safety of aging civil infrastructure, a worldwide problem. However, implementation of SHM in civil infrastructure faces a significant challenge due to the lack of suitable sensors and reliable methods for interpreting sensor data. This paper reviews recent efforts and advances made in addressing this challenge, with example sensor hardware and software developed in the author's research center. It is proposed to integrate real-time continuous monitoring using on structure sensors for global structural integrity evaluation with targeted NDE inspection for local damage assessment.

IoT 백신 냉장고를 사용한 개발도상국 백신 콜드체인 모니터링 시스템 (Vaccine Cold Chain Monitoring System Using IoT Vaccine Fridge for Developing Countries)

  • 유장현;박사무엘;류종하;왕심린;임혁순;이협승;안성훈
    • 적정기술학회지
    • /
    • 제7권1호
    • /
    • pp.26-32
    • /
    • 2021
  • 콜드체인의 마지막 단계인 백신전달 과정에서 대부분 얼음을 넣은 단열컨테이너로 온도를 조절하며, 백신의 온도 조절이 적절하지 않아 낭비되는 백신의 양이 상당하다. 예방접종을 관리하고 운영하는데 온도 데이터가 중요하며, 본 연구에서는 실시간 백신전달 모니터링 시스템을 개발하였다. 휴대용 백신 냉장고의 온도, 위치 및 전력 소비 데이터를 수집하기 위해 문자(Short Message Service) 통신 방법을 사용하였고, 한국과 탄자니아(아루샤 및 킬리만자로 지역)에서 시스템을 테스트하였다. 개발된 백신 냉장고는 문자통신을 통해 데이터 손실없이 실시간으로 백신상태를 모니터링을 할 수 있었다. 백신의 상태 및 데이터는 클라우드 서버를 통해 웹 기반 유저 인터페이스에서 확인할 수 있었다.

Developing a smart structure using integrated DDA/ISMP and semi-active variable stiffness device

  • Karami, Kaveh;Nagarajaiah, Satish;Amini, Fereidoun
    • Smart Structures and Systems
    • /
    • 제18권5호
    • /
    • pp.955-982
    • /
    • 2016
  • Recent studies integrating vibration control and structural health monitoring (SHM) use control devices and control algorithms to enable system identification and damage detection. In this study real-time SHM is used to enhance structural vibration control and reduce damage. A newly proposed control algorithm, including integrated real-time SHM and semi-active control strategy, is presented to mitigate both damage and seismic response of the main structure under strong seismic ground motion. The semi-active independently variable stiffness (SAIVS) device is used as semi-active control device in this investigation. The proper stiffness of SAIVS device is obtained using a new developed semi-active control algorithm based on real-time damage tracking of structure by damage detection algorithm based on identified system Markov parameters (DDA/ISMP) method. A three bay five story steel braced frame structure, which is equipped with one SAIVS device at each story, is employed to illustrate the efficiency of the proposed algorithm. The obtained results show that the proposed control algorithm could significantly decrease damage in most parts of the structure. Also, the dynamic response of the structure is effectively reduced by using the proposed control algorithm during four strong earthquakes. In comparison to passive on and off cases, the results demonstrate that the performance of the proposed control algorithm in decreasing both damage and dynamic responses of structure is significantly enhanced than the passive cases. Furthermore, from the energy consumption point of view the maximum and the cumulative control force in the proposed control algorithm is less than the passive-on case, considerably.

사물인터넷 기술을 이용한 가스상 물질 측정용 스마트센서 개발과 향후과제 (Development of an IoT Smart Sensor for Detecting Gaseous Materials)

  • 김욱;김영교;유연선;정기효;최원준;이완형;강성규;함승헌
    • 한국산업보건학회지
    • /
    • 제32권1호
    • /
    • pp.78-88
    • /
    • 2022
  • Objectives: To develop the smart sensor to protect worker's health from chemical exposure by adopting ICT (Information and Communications Technology) technologies. Methods: To develope real-time chemical exposure monitoring system, IoT (Internet of Things) sensor technology and regulations were reviewed. We developed and produced smart sensor. A smart sensor is a system consisting of a sensor unit, a communication unit, and a platform. To verify the performance of smart sensors, each sensor has been certified by the Korea Laboratory Accreditation Scheme (KOLAS). Results: Chemicals (TVOC; Total Volatile Organic Compounds, Cl2: Chlorine, HF: Hydrogen fluoride and HCN: Hydrogen cyanide) were selected according to a priority logic (KOSHA Alert, acute poisoning statistics, literature review). Notifications were set according to OEL (occupational exposure limit). Sensors were selected based on OEL and the capabilities of the sensors. Communication is designed to use LTE (Long Term Evolution) and Wi-Fi at the same time for convenience. Electronic platform were applied to build this monitoring system. Conclusions: Real-time monitoring system for OEL of hazardous chemicals in workplace was developed. Smart sensor can detect chemicals to complement monitoring of traditional workplace environmental monitoring such as short term and peak exposure. Further research is needed to expand the scope of application, improve reliability, and systematically application.

포터블 기반 스마트 구조 응답 모니터링 시스템 개발 및 현장 적용성 평가 (Development of a Portable-Based Smart Structural Response Monitoring System and Evaluation of Field Applicability)

  • 박상기;서동우;박기태;김호진
    • 한국방재안전학회논문집
    • /
    • 제16권4호
    • /
    • pp.147-156
    • /
    • 2023
  • 케이블 교량의 거동은 동적 응답에 의해 지배적이며 상대적으로 복잡하므로 교량의 상태를 평가하기 위한 장단기 현장 계측이 요구되는 경우가 빈번하다. 영구적인 SHMS(Structural Health Monitoring System)가 설치되지 않은 경우 성능평가를 위해 이동식 모니터링 시스템이 필요하다. 이 경우 교량의 위치와 형태에 따라 전력, 통신 등의 제한된 여건으로 인해 이동식 모니터링 시스템 운영에 어려움이 발생할 수 있다. 본 연구에서는 국내는 물론 동남아 지역 교량의 장 ‧ 단기 모니터링에 효과적으로 활용될 수 있는 포터블 기반의 스마트 구조응답 모니터링 시스템을 개발하였다. 개발된 시스템은 현장에서 자체 전원 공급 시스템을 이용하여 장시간 운용이 가능한 다채널 휴대용 데이터 수집 및 분석 장비이며, 실시간 데이터를 이용하여 케이블 교량의 동적 특성을 자동으로 분석할 수 있는 알고리즘을 탑재하고 있다. 개발된 시스템의 현장 적용성을 평가하기 위해 한국과 베트남의 케이블 교량에서 현장 실증을 수행하였으며, 이를 통해 개발된 시스템의 현장 운영의 신뢰성과 효율성을 확인하였고, 추가적으로 케이블 교량 모니터링 분야에서의 해외 시장 적용 가능성을 확인하였다.

Constructing a digital twin for estimating the response and load of a piping system subjected to seismic and arbitrary loads

  • Dongchang Kim;Gungyu Kim;Shinyong Kwag;Seunghyun Eem
    • Smart Structures and Systems
    • /
    • 제31권3호
    • /
    • pp.275-281
    • /
    • 2023
  • In recent years, technological developments have rapidly increased the number of complex structures and equipment in the industrial. Accordingly, the prognostics and health monitoring (PHM) technology has become significant. The safety assessment of industrial sites requires data obtained by installing a number of sensors in the structure. Therefore, digital twin technology, which forms the core of the Fourth Industrial Revolution, is attracting attention in the safety field. The research on digital twin technology of structures subjected to seismic loads has been conducted recently. Hence, this study proposes a digital twin system that estimates the responses and arbitrary load in real time by utilizing the minimum sensor to a pipe that receives a seismic and arbitrary load. To construct the digital twin system, a finite-element model was created considering the dynamic characteristics of the pipe system, and then updating the finite-element model. In addition, the calculation speed was improved using a finite-element model that applied the reduced-order modeling (ROM) technology to achieve real-time performance. The constructed digital twin system successfully and rapidly estimated the load and the point where the sensor was not attached. The accuracy of the constructed digital twin system was verified by comparing the response of the digital twin model with that derived by using the load estimated from the digital twin model as input in the finite-element model.

리눅스 기반 ARINC 653 헬스 모니터 (Linux-based ARINC 653 Health Monitor)

  • 윤영일;조현우;김형신
    • 대한임베디드공학회논문지
    • /
    • 제9권3호
    • /
    • pp.183-191
    • /
    • 2014
  • The software running on avionic system is required to be highly reliable and productive. The air transport industry has developed ARINC Specification 653(ARINC653) as a standardized software requirement of avionics computers. The document specifies the interface boundary between avionics application software and the core executive software. Dependability in ARINC 653 is provided by spatial and temporal partitioning whilst fault-tolerance is provided by health monitoring mechanism. Legacy real-time operating systems are used to support ARINC653 health monitor on integrated modular avionics(IMA). However, legacy real-time operating systems are costly and difficult to modify the kernel. In this paper, we suggest a Linux-based ARINC653 health monitor. Functionalities to support ARINC653 health monitor are implemented as a Linux kernel module and its performance is evaluated.

Sensor enriched infrastructure system

  • Wang, Ming L.;Yim, Jinsuk
    • Smart Structures and Systems
    • /
    • 제6권3호
    • /
    • pp.309-333
    • /
    • 2010
  • Civil infrastructure, in both its construction and maintenance, represents the largest societal investment in this country, outside of the health care industry. Despite being the lifeline of US commerce, civil infrastructure has scarcely benefited from the latest sensor technological advances. Our future should focus on harnessing these technologies to enhance the robustness, longevity and economic viability of this vast, societal investment, in light of inherent uncertainties and their exposure to service and even extreme loadings. One of the principal means of insuring the robustness and longevity of infrastructure is to strategically deploy smart sensors in them. Therefore, the objective is to develop novel, durable, smart sensors that are especially applicable to major infrastructure and the facilities to validate their reliability and long-term functionality. In some cases, this implies the development of new sensing elements themselves, while in other cases involves innovative packaging and use of existing sensor technologies. In either case, a parallel focus will be the integration and networking of these smart sensing elements for reliable data acquisition, transmission, and fusion, within a decision-making framework targeting efficient management and maintenance of infrastructure systems. In this paper, prudent and viable sensor and health monitoring technologies have been developed and used in several large structural systems. Discussion will also include several practical bridge health monitoring applications including their design, construction, and operation of the systems.

복합재료 평판의 헬스 모니터링 (Health Monitoring of Composite Plates)

  • 김당원;전흥재;이충희;변준형;엄문광
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2006년도 정기 학술대회 논문집
    • /
    • pp.15-20
    • /
    • 2006
  • Real time health monitoring system was studied to detect the . generation of defects in the composite structures during service life. The PZT sensors were embedded into the woven-glass/phenol composite plate during the fabrication. VARTM (Vacuum Assisted Resin Transfer Molding) process were used to fabricate the composite plate. A Teflon tape was embedded between glass fiber layers to mimic delamination induced during service. Normalized maximum amplitude and energy analyses were used for the acquired signals. Both amplitude and energy of acquired signals were extremely sensitive to the delamination. Therefore, it was successful to detect and to locate the defects in composite plate by monitoring signals from sensors and using the proposed method.

  • PDF

타워크레인의 기울어짐 측정 시스템 개발 (The Development of the Slope Monitoring System(SMS) of the Tower Crane)

  • 신운철;홍용수
    • 한국안전학회지
    • /
    • 제25권6호
    • /
    • pp.60-64
    • /
    • 2010
  • The purpose of this study if to prevent dangerous accident of the overthrow of the tower crane in summer's hurricane. We develop the SMS in order to give automatic alarm system to operator within the dangerous range and to give a information of the exactly slope in the real time. The slope value of the tower crane is compose of direction, pitch by the front and rear, roll by the right and left and synthesis by the its pitch and roll. Especially, the synthesis eliminate the effect of the wall tie or wire bracing. So, this value should correctly indicate the actual slope. In this study, more applying field test should be applied with the SMS. In the future, a more measurement device can be applied to, and be able to feed more alarm criteria for the review of the risk in the field.