• 제목/요약/키워드: readout

검색결과 271건 처리시간 0.026초

Operation and System Upgrade of KMTNet

  • Lee, Chung-Uk;Kim, Seung-Lee;Cha, Sang-Mok;Lee, Yongseok;Kim, Dong-Jin;Lee, Dong-Joo;Lim, Jin-Sun;Park, Byeong-Gon
    • 천문학회보
    • /
    • 제42권1호
    • /
    • pp.43.3-44
    • /
    • 2017
  • We report the operational highlights of KMTNet in the point of observing rate, image pre-processing and data reduction, observing run for each science program, and scientific publications performed in 2016. Major system upgrade has been conducted in the CCD camera and the wide field telescope optics: the post amp and readout electronics of the 18k Mosaic CCD camera at Siding Spring Observatory site has been fine tuned and the protected silver coat of the primary mirror has been replaced with the bare aluminium coat due to the degradation of reflectivity of the primary mirror surface. A plan of KMTNet observation system improvement for 2017 will be introduced in this talk.

  • PDF

주식투자(株式投資)에 관(關)한 모의(模擬)게임 (Portfolio Management Game Applicable to Korean Stock Market)

  • 오성백;황학
    • 대한산업공학회지
    • /
    • 제3권1호
    • /
    • pp.55-59
    • /
    • 1977
  • This paper develops a portfolio management game applicable to Korean Stock Market with an emphasis on teaching and training aid. It allows each participant to start out with a certain amount of money and pick his favorable stocks from a list of stocks chosen by instructor. Each participant must make a transaction at each time period and he gets a readout that states his individual performance, i.e., stock lists, cash on hand, net worth, transactions he has made and rank in accordance with his net worth. This game package consists of 10 subprograms and 7 files written with Fortran language for use on the Nova 840 computer and is divided into 3 main categories according to their functions, i.e., book-keeping function, data processing function and information searching function. This package may be used for training portfolio decison makings in the stock market and for comparing various investment methods through hypothetical investments.

  • PDF

나노입자 배열을 이용한 분자 검출 (Detection of Molecules using the Nanoparticle Arrays)

  • 하동한;김상훈;윤용주;박형주;윤완수
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회A
    • /
    • pp.1617-1622
    • /
    • 2008
  • We report a new molecular detection process which measures the changes in the plasmon resonance peaks of periodic Au nanoparticle arrays fabricated using the electron beam lithography. As the Au nanoparticle arrays are modified by the chemical reaction in solutions having various concentrations of a target molecule, both the position and intensity of the plasmon peak change in proportion to the concentration of the target molecule. We expect that the process developed in this work can be employed for fine tuning of the plasmon peak wavelength and also for the optical detection of various kinds of molecules. Moreover, this method may improve the measurement accuracy compared with existing approaches that use only one change (peak wavelength or peak intensity) as a readout value for the molecular detection.

  • PDF

Slim-type 광학식 정보저장기기에서의 디스크 변형에 관한 실험적 연구 (An Experimental Study of Disc Warping in Slim-type Optical Disc Drive)

  • 이재성;임윤철
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.676-681
    • /
    • 2003
  • In this paper, we investigated the disc warping in high-speed slim-type optical disc drive. Recently, the information storage devices are increasing track density and higher rotation speed to enhance their recording capacity and their data transfer rate. Generally, ODD used in the Lap-top Computer has small inner space. So, the flow instability of inner space is rapidly increased as its higher rotation speed. An extreme case, the flow instability causes the malfunction of readout at pick-up of drives. The experiments and numerical analysis were carried out for several cases, the result shows the influence of airflow to the disc warping.

  • PDF

비정길 칼코게나이드 As-Ge-Se-S 박막에서 편광기록 재생 (Polarization recording and reconstruction in the chalcogenide As-Ge-Se-S thin films)

  • 장선주;박종화;손철호;정홍배
    • 한국전기전자재료학회논문지
    • /
    • 제13권9호
    • /
    • pp.781-785
    • /
    • 2000
  • Chalcogenide glasses are suggested as a candidate for optical recording. In this study, we have investigated the holography recording and reconstruction of the polarization state in chalcogenide As$_{40}$ Ge$_{10}$Se$_{15}$ S$_{35}$ thin films. We have used a He-Ne laser light(633nm) to probe and record of the grating. Also the polarization state of object beam was modulated with a λ/4 wave plate. The polarization state of the +1st order diffracted beam was generated by readout of the grating with a linearly polarized reference beam. It was the same-handed polarization state as the polarization state of the recording beam. The result is shown that the diffraction efficiency of circularly polarized recording represents higher than other polarization state.ate.e.

  • PDF

다중 Echo를 이용한 Single Scan Inhomogeneity Field Mapping (Sine Scan Inhomogeneity Field Mapping using Multiple Echo)

  • 김치영;한수영;정관진;오창현;이윤;안창범
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1998년도 추계학술대회
    • /
    • pp.307-308
    • /
    • 1998
  • In this paper, we describe a field measurement technique using multiple gradient echo method. For this purpose, 3 differential phase map is used between two images obtained in a single scan. The phase map is further processed to unfold phase folding (2n $\pi$). The inhomogeneity map is used to correct image distortion along readout gradient direction. Some experimental results obtained at 1.0 Tesla whole body MR system are shown with the proposed technique.

  • PDF

비정질 실리콘 디지털 방사선 촬영기의 개발 (Development of Amorphous Silicon Based Digital Radiography System)

  • 이형구;서태석;최보영;신경섭;김홍권
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1998년도 추계학술대회
    • /
    • pp.94-95
    • /
    • 1998
  • We developed a digital x-ray medical imaging system using commercially available amorphous silicon image sensor plate. The image readout could be accomplished within 3.5 sec after radiation exposure and be displayed on a monitor through computer interface. This system needs not the conventional x-ray films and film processors, and also provides digital radiographic images. This system is the fastest digital radiography system developed so far, and expected to replace many of the conventional x-ray film systems or digital radiography systems.

  • PDF

Assessing the Nano-Dynamics of the Cell Surface

  • Bae, Chil-Man;Park, Ik-Keun;Butler, Peter J.
    • 비파괴검사학회지
    • /
    • 제32권3호
    • /
    • pp.263-268
    • /
    • 2012
  • It is important to know the mechanism of cell membrane fluctuation because it can be readout for the nanomechanical interaction between cytoskeleton and plasma membrane. Traditional techniques, however, have drawbacks such as probe contact with the cell surface, complicate analysis, and limit spatial and temporal resolution. In this study, we developed a new system for non-contact measurement of nano-scale localized-cell surface dynamics using modified-scanning ion-conductance microscopy. With 2 nm resolution, we determined that endothelial cells have local membrane fluctuations of ~20 nm, actin depolymerization causes increase in fluctuation amplitude, and ATP depletion abolishes all membrane fluctuations.

眞圓度 測定器의 誤差特性에 대한 解析 -위상차법- (An Analysis of Performance Error of Roundness Measuring Instrument -by phase different method-)

  • 한응교;허문석;박익근
    • 오토저널
    • /
    • 제10권3호
    • /
    • pp.31-37
    • /
    • 1988
  • A phase different method to evaluate the instrument error of roundness measuring instrument and the form error of specimens for the calibration of the instrument is used. An instrument with a rotary table supported by an air bearing was calibrated by using the standard balls as a standard. The calibration was carried out repeatedly by setting the same ball in 12 phase angles(per 30.deg.) on the table and by recording their roundness errors with a magnification of 100,000 times. As a result of data analysis of all the observations, readout at each of 144 orientations(per 2.5.deg.) from recorded data file, the error of performance of the instrument and the specimens are separated. In the particular instrument used in the present experiment, the error of the instrument was determined with the accuracy of 0.0164 (.mu.m) and the form error of the specimens was determined with the accuracy of 0.0264,0.0172(.mu.m), respectively. If the instrument was calibrated by using the above specimens, then the accuracy of the measurement of roundness error can be improved to about 0.017 (.mu.m).

  • PDF

Direct Aerosol Analysis by Time Resolved Laser Plasma Spectroscopy - Improvement by Single Shot Measurements

  • Schechter, Israel
    • 분석과학
    • /
    • 제8권4호
    • /
    • pp.779-786
    • /
    • 1995
  • Environmental and industrial aerosols can be analyzed on-line by laser plasma spectroscopy. The main problem in direct (no preparation or presorting) aerosol analysis is the extensive spectral fluctuations. A method to partially solve this problem is proposed. It is based on single shot measurements and application of a special rejection algorithm. The major factors that influence the spectral variations are discussed, in relation to the correction possibility by a rejection program. The method works well when average intensity of the single spectra is relatively high, as compared to detector's saturation limit. If intensities are too low, the accumulation of readout noise is critical, and no improvement is expected.

  • PDF