• 제목/요약/키워드: reactors

검색결과 1,809건 처리시간 0.026초

THE GRAPHICAL D-Q TRANSFORMATION OF GENERAL POWER SWITCHING CONVERTERS

  • Rim, Chun-T.;Hu, Dong-Y.;Cho, Gyu-H.
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1988년도 추계학술대회 논문집 학회본부
    • /
    • pp.388-393
    • /
    • 1988
  • New circuit D-Q transformation concept is introduced to analyze AC converters such as inverters, rectifiers and cyclo-converters with ease. The equivalent linear time invariant circuit is obtained by substituting switches with equivalent turn-ratio variable transformers and changing balanced AC reactors into equivalent DC reactors combined by gyrators. This circuit enables us to utilize the powerful linear system analysis techniques such as Laplace transform otherwise which could not be applied to the time varying switching systems. Direct substitution of switches of DC converters with transformers is shown as a preliminary. Then the modeling procedure is shown for a controlled rectifier-inverter circuit. Finally an analysis example is proposed for a buck-boost inverter and the result is compared with the conventional approach. This approach is applicable to all AC converter families to determine the AC transfer functions and the DC operating points. It is identified that the switching systems are equivalent to the RLC filter circuits with transformers and gyrators.

  • PDF

350MWe 원자력 발전소의 발전원가 추정 (Power cost evaluation of 350 MWe nuclear power plant)

  • 노윤래
    • 전기의세계
    • /
    • 제16권4호
    • /
    • pp.41-49
    • /
    • 1967
  • This paper covers an estimation and analysis of generating cost of 350MWe nuclear power plant using a pressurized water reactor on the assumption that such a nuclear power plant would be constructed in Korea in or around 1970. For the evaluation of this generating cost, an extensive study has been conducted based on the current information on operating and costing parameters of light water reactors, particularly those of pressurized water reactors. Based on this study, a total generating cost of 7.29 Mills/Kwh was evaluated by operating the plant at 80% plant factor. For this calculation, a steady state method was introduced. It is considered, therefore, that a total generating cost in the beginning of plant operation would be a little higher than 7.29 Mills/Kwh, which has been calculated in the state of equilibrium.

  • PDF

양돈폐수의 혐기성 소화에 대한 암모니아의 영향 (Ammonia Effects on Anaerobic Digestion of Swine Wastewaters)

  • 김종수
    • 유기물자원화
    • /
    • 제10권1호
    • /
    • pp.102-108
    • /
    • 2002
  • The effects of ammonia on mesophilic anaerobic digestion were investigated by operating lab-scale two-stage ASBF reactors using swine wastewaters as influent without and with ammonia removal at HRT of 1-2 days and OLR of $2.2{\sim}9.6kg-COD/m^3{\cdot}d$ for 250 days. The COD removal efficiency and biogas generation of two-stage ASBF reactors was decreased by increasing influent ammonia concentrations to 1,580 mg(T-N)/L with increasing OLR to $6.3kg-COD/m^3{\cdot}d$, while those were increased by maintaining influent ammonia concentrations below 340 mg(T-N)/L by MAP precipitation with increasing OLR to $9.6kg-COD/m^3{\cdot}d$. Initial inhibirion of ammonia on anaerobic processes was observed at a concentration of 760 mg(T-N)/L and the COD removal efficiency and biogas generation dropped to 1/2 at ammonia concentration ranges of 1,540~1,870 mg(T-N)/L. It is essential to remove ammonia in swine wastewaters to an initial inhibition level before anaerobic processes for the effective removal of COD.

  • PDF

Membrane Contactors for Water Carbonation

  • Alessandra Criscuoli;Enrico Drioli
    • 멤브레인
    • /
    • 제1권1호
    • /
    • pp.59-59
    • /
    • 1991
  • A theoretical and experimental study made in order to determine the performance of mem-brane contactors in water carbonation is presented. In particular on the basis of experimental results pre-viously obtained it has been derived an expression in which the effect of some parameters as temprera-ture water and CO₂ flow rate CO₂ pressure trans-membrane pressure on the performance of the process is taken into account. The study refers to hollow fiber membrane contactors used for the experimental tests. The main scope has been to verify if by membrane contactors it is possible to reach the same de-gree of water carbonation as by trditional methods (1-5 g/1) and to derive for the module used a cor-relation able to describe the performance of the process at several operating conditions. The high CO₂ removal observed confirms the interesting potentialties of membrane contactors also in gas streams purification.

SBR에서 포기기간 변경에 따른 질소.인 제거 특성 (Nitrogen and Phosphorus Removal Characteristics by the Variation of Aeration Time in SBR)

  • 김동석;박영식
    • 한국환경보건학회지
    • /
    • 제35권2호
    • /
    • pp.116-123
    • /
    • 2009
  • Laboratory scale experiments were conducted to investigate the removal characteristics of nitrogen and phosphorus by the variation of aeration time in four sequencing batch reactors (SBRs). In R1 which has the shortest aeration time as 1 h, MLVSS concentration in reactor decreased by the wash-out of biomass because of the poor sedimentation. The TOC removal efficiencies were almost similar in 3 reactors except R1. At the low aeration time as 1 h, the nitrification was severely inhibited by the deficiency of oxygen. ${NH_4}^+$-N removal efficiency was decreased by the decrease of aeration time. At the aeration time over 2 h, the phosphorus removal efficiency was not affected by the variation of aeration time. The nitrification was inhibited but the phosphorus release and uptake was not inhibited by the decrease of low aeration time. Therefore, we can see that the phosphorus removal microorganisms are superior to nitrification microorganisms in oxygen utilization.

클로라민 소독에 의한 종속영양세균과 질산화세균의 불활성화 및 재성장 억제 (The Inactivation and Microbial Regrowth Inhibition of Heterotrophic and Nitrifying Bacteria by Chloramination)

  • 조관형;김평청;우달식;조영태
    • 한국환경과학회지
    • /
    • 제10권3호
    • /
    • pp.247-252
    • /
    • 2001
  • This study was performed to evaluate the inactivation and microbial regrowth of heterotrophic and nitrifying bacteria using chloramine as a secondary disinfectant for drinding water distribution system. Three sets of the three reactors filled with the $Cl_2/NH_3-N$ ratio of 3:1, 4:1, and 5:1 were used in these experiments. Chloramine concentration were applied to each set of the reactors with $1mg/\ell$,\;2mg/\ell\;and\;3mg/\ell$, respectively. For the set with elapsed time and reached to zero level after 7 days. Heterotrophic bacteria remarkably increased and nitrification through the experimenatal period (21 day). Furthermore the regrowth of heterotrophic bacteria and nitrification were not found. More than $2mg/\ell$ of chloramine with $Cl_2/NH_3-N$ ratio of 3:1, the nitrification could be inhibited by 2 days of contact time.

  • PDF

Glutamate Decarboxylase (GAD)를 이용한 Gamma-Amino Butyric Acid (GABA) 생산 및 최적화 (Effects and Optimization of Gamma-Amino Butyric Acid (GABA) Production Process using Glutamate Decarboxylase (GAD))

  • 김의진;이중헌
    • KSBB Journal
    • /
    • 제29권6호
    • /
    • pp.426-431
    • /
    • 2014
  • pH controlled batch reactor and bubble column reactors have been developed in this research. They were used to produce high concentration of GABA and to determine optimal pH for GABA production. Glutamate decarboxylase (GAD) was isolated from recombinant E. coli and used for GABA production from monosodium glutamate (MSG). pH control was inevitable because the pH increased with MSG consumption. GAD showed highest activity at acidic conditions at pH 5.5 but the optimal pH for GABA production was pH 6.0. When 1.5 mole of MSG was used as reactant, the 1.05 mole of GABA was produced after 10 hrs batch reaction. Using bubble column reactors, 80 % of MSG was converted to GABA for 6 hrs reaction and 1.2 mole of GABA was produced.

기존 정수처리방법으로 제거가 어려운 유기물에 대한 실험적 연구 (Retrospect on Refractories in Water Treatment)

  • 우달식;남상호
    • 한국환경보건학회지
    • /
    • 제21권4호
    • /
    • pp.17-23
    • /
    • 1995
  • As a basic experiment to develope biological pretreatment proces~ in water treatment, the experiments on biodegradability and isothermal adsorption of activated carbon were performed on refractories such as humic acid, $NH_3-N$, phenol and ABS which caused the problems in drinking water treatment. Also, the treatabilities on humic acid were examined in the continuous flow type reactors. The removal efficiencies of humic acid, $NH_3-N$, phenol and ABS in the biodegradable experiments for 5 days were 20.1%, 73.4%, 91.7% and 97.5%, respectively. In the isothermal adsorption test of refractories on activated carbon to be used as a media in the continuous flow type reactors, ABS and phenol are adsorbed easily, but humic acid and $NH_3-N$ are difficult to be done. The removal efficiencies of humic acid in granular activated carbon(GAC) reactor were about 7-8% higher than in biological activated carbon(BAC) reactor. The removal efficiencies of humic acid in biological fluidized bed(BFB) reactor were about 30% in GAC media, but were almost zero in sea sand media.

  • PDF

접시형 고온 태양열 화학 반응기의 열전달 및 수소생산 성능 분석 (Performance Analysis of Heat Transfer Characteristic and Hydrogen Product for Dish Type Solar Chemical Reactor)

  • 양승복;고만석;오상준;서태범
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.774-779
    • /
    • 2009
  • The purpose of this research is to develop the high performance of solar chemical reactor for producing hydrogen by methane reforming reaction with steam. Two shape of chemical reactor is suggested: first type is filled with porous material and second type is spiral type. These reactors is installed on the dish-type thermal system of Inha University, Inha Dish-1. Performance analysis of these two reactors is conducted from getting methane conversion.

  • PDF

BAF를 이용한 하수의 3차 처리 및 by-pass된 우수의 처리 (Tertiary Treatment of Municipal Wastewater and Bypassed Rainfall Treatment using by BAF)

  • 이광제;박재홍
    • 한국물환경학회지
    • /
    • 제21권4호
    • /
    • pp.327-331
    • /
    • 2005
  • The study was conducted with two laboratory biological aerated filter (BAF) reactors: denitrification filter (DF) and nitrification BAF. The influent flow (Q) was fixed to 48 L/d and total empty bed contact time (EBCT) was 1 hr. The flow direction was upflow with NRCY of 1 to 2Q. The secondary effluent was fed to the reactors and the influent concentrations were adjusted with some stock solutions to simulate by-pass concentration during rainfall. The study results indicate that COD and SS removal efficiencies were excellent and not influenced by temperature. Nitrification efficiency was over 90% at the influent loading less than $1.12kg/media\;m^3/d$, but the efficiencies were decreased in low temperature. TN removal efficiencies were 10% to 60%.