• Title/Summary/Keyword: ray.

Search Result 20,659, Processing Time 0.061 seconds

A Study on the Optimal Design of Soft X-ray Ionizer using the Monte Carlo N-Particle Extended Code (Monte Carlo N-Particle Extended 코드를 이용한 연X선 정전기제거장치의 최적설계에 관한 연구)

  • Jeong, Phil hoon;Lee, Dong Hoon
    • Journal of the Korean Society of Safety
    • /
    • v.32 no.2
    • /
    • pp.34-37
    • /
    • 2017
  • In recent emerging industry, Display field becomes bigger and bigger, and also semiconductor technology becomes high density integration. In Flat Panel Display, there is an issue that electrostatic phenomenon results in fine dust adsorption as electrostatic capacity increases due to bigger size. Destruction of high integrated circuit and pattern deterioration occur in semiconductor and this causes the problem of weakening of thermal resistance. In order to solve this sort of electrostatic failure in this process, Soft X-ray ionizer is mainly used. Soft X-ray Ionizer does not only generate electrical noise and minute particle but also is efficient to remove electrostatic as it has a wide range of ionization. X-ray Generating efficiency has an effect on soft X-ray Ionizer affects neutralizing performance. There exist variable factors such as type of anode, thickness, tube voltage etc., and it takes a lot of time and financial resource to find optimal performance by manufacturing with actual X-ray tube source. MCNPX (Monte Carlo N-Particle Extended) is used for simulation to solve this kind of problem, and optimum efficiency of X-ray generation is anticipated. In this study, X-ray generation efficiency was measured according to target material thickness using MCNPX under the conditions that tube voltage is 5 keV, 10 keV, 15 keV and the target Material is Tungsten(W), Gold(Au), Silver(Ag). At the result, Gold(Au) shows optimum efficiency. In Tube voltage 5 keV, optimal target thickness is $0.05{\mu}m$ and Largest energy of Light flux appears $2.22{\times}10^8$ x-ray flux. In Tube voltage 10 keV, optimal target Thickness is $0.18{\mu}m$ and Largest energy of Light flux appears $1.97{\times}10^9$ x-ray flux. In Tube voltage 15 keV, optimal target Thickness is $0.29{\mu}m$ and Largest energy of Light flux appears $4.59{\times}10^9$ x-ray flux.

Evaluation of Effectiveness of New Design Lead Apron during Pregnant X-ray Chest P-A (임산부 흉부 촬영중 사용할 새로 디자인된 납치마의 효율성 평가)

  • Kim, Hyeonggyun;Kwon, Soonmu;Jung, Hongmoon
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.6
    • /
    • pp.441-445
    • /
    • 2012
  • X-ray Chest P-A is very important and basic diagnosis examination for pregnant women. For a pregnancy period pregnant women should be treated very carefully not to be exposed to any radiation which might cause harmful damage to women and babies as well. Lead apron is one of the effective methods to protect pregnant women from the X-ray radiation. However, it is difficult to obtain the accurate position of pregnant women during X-ray Chest P-A since conventional lead apron method forces pregnant women to hold the apron by themselves only to make pregnant women very uncomfortable and hard to maintain accurate position during radiation. As a consequence, it is common to get low quality images of X-ray Chest P-A due to the overlap of apex of lung and scapular. In order to fix this problem, we made new design lead apron that allowed pregnant women to be more comfortable to maintain accurate position during X-ray Chest P-A position. Finally, with this new design lead apron, it was possible to get the best optimized images of X-ray Chest P-A of pregnant women by minimizing overlapping apex of lung and scapular.

Detection of Hidden Proximal Caries using Q-ray view in Primary Molars (Q-ray view를 이용한 유구치의 숨은 인접면 우식증 탐지)

  • Jeong, Younwook;Lee, Hyoseol;Choi, Hyungjun;Lee, Jaeho;Choi, Byungjai;Kim, Seongoh
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.42 no.3
    • /
    • pp.209-217
    • /
    • 2015
  • The purpose of this study was to evaluate the ability of Q-ray view (All-in-one Bio, Seoul, Korea) in detection of proximal caries in primary molars with sound marginal ridges. Thirty two children aged 3-9 years (average $5.6{\pm}1.3$ years old) were chosen, and two examiners evaluated 100 proximal surfaces of primary molars with sound marginal ridges. The teeth were examined with; (a) visual examination, (b) Q-ray view, (c) DIAGNOdent (KaVo, Biberach, Germany) and (d) digital periapical radiography. Kappa statistic was used to assess the agreement between each examination method and the degree of caries progression. The kappa values for enamel caries were 0.15 (visual examination), 0.10 (Q-ray view), 0.25 (DIAGNOdent) and 0.68 (digital periapical radiography). The kappa values for dentinal caries were 0.34 (visual examination), 0.56 (Q-ray view), 0.44 (DIAGNOdent) and 0.70 (digital periapical radiography). Although Q-ray view showed low diagnostic ability in detection of enamel caries, it was effective in detection of hidden proximal caries extended into dentin. Q-ray view would be a useful and simple device which could aid pediatric dentists in detection of hidden proximal caries in primary molars especially when examining uncooperative children or disabled persons.

Comparison Between Ultrasonic and X-ray Methods for Imaging the Children′s Growth Plate (어린이 성장판 영상화를 위한 초음파와 X-선 방식의 비교 평가)

  • Kim Sang Hoo;Kim Hyung Jun;Han Eun Ok;Han Seung Moo
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.6
    • /
    • pp.551-556
    • /
    • 2004
  • The purpose of this study was to suggest a systematic and scientific method for measurement of children's growth development, in which the accuracy of existing diagnosis method has not been concretely examined yet. The most popular method for diagnosis of children's growth is to analyze the opening degree of growth plate in each joint by X-ray image. However, X-ray method has some disadvantages; it is impossible to measure the diagnosis of growth periodically and repeatedly due to the radiation problem. Hence, this study introduced a profile analysis and the algorithm of analyzing the image of growth plate with the BUA(Broadband Ultrasound Attenuation) of calcaneus, to verify the possibility of alternative ultrasonic method harmless to human body. We obtained the images of growth plate in proximal tibiae, phalanges, and calcanei of 269 children (7∼16 years old) with X-ray. And the image of growth plate in calcanei was also obtained front those children with ultrasound. The results showed that the time of the opening degree of growth plate in each joint was almost consistent between X-ray and ultrasonic images. Also, the images of growth plate measured by X-ray and ultrasound showed the high correlation. Therefore, it is expected that the algorithm of ultrasonic profile analysis introduced in this study can replace the existing X-ray method to measure the growth plate correctly.

Image Quality Improvement through Energy Spectrum Change for X-ray (엑스선 에너지스펙트럼 변경을 통한 영상 화질 향상에 관한 연구)

  • Kim, Gu;Kim, Neung Gyun;Lee, Seung-Jae
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.1
    • /
    • pp.71-78
    • /
    • 2021
  • When continuous X-ray are used when acquiring and X-ray image, even the same material may not be accurately represented in the image according to the thickness due to various X-ray energies. To solve this problem, the X-ray energy spectrum was changed to improve the image quality. Using SPEKTR v3.0, an X-ray energy spectrum with an additional filter added and a general X-ray energy spectrum using only a unique filter were obtained. Simulation was performed using the obtained X-ray energy spectrum as a radiation source for Geant4 Application for Tomographic Emission (GATE). Using GATE data, an X-ray image with an additional filter and an image reconstructed from and X-ray image without an additional filter were compared and analyzed through a mono energy image of 74 keV. In the case of using the X-ray energy spectrum without using an additional filter, the amount of X-rays transmitted according to the thickness of the same material is different from the amount that decreases according to the thickness of the material. Similar results were obtained as the amount decreased with the material thickness. In other words, a similar result was obtained when the reduced dose was used with a mono energy. When an X-ray image is obtained by changing an X-ray energy spectrum using an additional filter, a more accurate result of transmission of X-rays may be obtained. In radiological examination, it was confirmed that the appropriate use of the additional filter has a great effect on improving the image quality.

Assessment of Neutron Skyshine Dose in a Cargo Inspection Facility Using High Energy X-ray (고에너지 X-ray를 이용한 화물검색시설에서의 중성자 Skyshine 방사선량률 평가)

  • Cho, Young-Ho
    • Journal of the Korean Society of Radiology
    • /
    • v.2 no.3
    • /
    • pp.27-31
    • /
    • 2008
  • The radiation protection measures for the photoneutrons are one of the most important issue of radiation safety in high energy X-ray facilities. When the photoneutrons are released from the facility, the general public as well as occupational workers are exposed to unexpected radiations by neutron skyshine effect. In this study, the photoneutron inventory are calculated using monte carlo mothed, and the neutron skyshine dose rate is assessed using the inventory. A 9MeV X-ray cargo inspection facility is considered as a reference facility.

  • PDF

Development of state-of-the-art detectors for X-ray astronomy

  • Lee, Sang Jun;Adams, J.S.;Audley, H.E.;Bandler, S.R.;Betancourt-Martinez, G.L.;Chervenak, J.A.;Eckart, M.E.;Finkbeiner, F.M.;Kelley, R.L.;Kilbourne, C.A.;Porter, F.S.;Sadleir, J.E.;Smith, S.J.;Wassell, E.J.
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.40 no.1
    • /
    • pp.53.3-54
    • /
    • 2015
  • We are developing large arrays of X-ray microcalorimeters for applications in X-ray astronomy. X-ray microcalorimeters can detect the energy of X-rays with extremely high resolution. High-resolution Imaging spectroscopy enabled by these arrays will allow us to study the hot and energetic nature of the Universe through the detection of X-rays from astronomical objects such as neutron stars or black holes. I will introduce the state-of-the-art X-ray microcalorimeters being developed at NASA/GSFC and the future X-ray observatory missions based on microcalorimeters.

  • PDF

A Study on FIBEX Automatic Generation Algorithm for FlexRay Network System (FlexRay 네트워크 시스템을 위한 FIBEX 자동 생성 알고리즘에 관한 연구)

  • Park, Ji-Ho;Lee, Suk;Lee, Kyung-Chang
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.8 no.2
    • /
    • pp.69-78
    • /
    • 2013
  • As vehicles become more intelligent for safety and convenience of drivers, in-vehicle networking systems such as controller are network (CAN) have been widely used due to increasing number of electronic control unit (ECU). Recently, FlexRay was developed to replace CAN protocol in chassis networking systems, to remedy the shortage of transmission capacity and unsatisfactory real-time transmission delay of conventional CAN. However, it is difficult for vehicle network designers to calculate platform configuration registers (PCR) and determine a base cycle or slot length of FlexRay. To assist vehicle network designers for designing FlexRay cluster, this paper presents automatic field bus exchange format (FIBEX) generation algorithm from CANdb information, which is de-facto standard database format for CAN. To design this program, structures of FIBEX, CANdb and relationship among PCR variables are analyzed.

Analysis of X-ray image qualities-accuracy of shape and clearness of image-using X-ray digital tomosynthesis

  • Roh, Young Jun;Kang, Sung Taek;Kim, Hyung Cheol;Kim, Sung-Kwon
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1997.10a
    • /
    • pp.572-576
    • /
    • 1997
  • X-ray laminography and DT(digital tomosynthesis) that can form a cross-sectional image of 3-D objects promise to be good solutions for inspecting interior defects of industrial products. The major factors of the digital tomosynthesis that influence on the quality of x-ray cross-sectional images are also discussed. The quality of images acquired from the DT system varies according to image synthesizing methods, the number of images used in image synthesizing, and X-ray projection angles. In this paper, a new image synthesizing method named 'log-root method' is proposed to get clear and accurate cross-sectional images, which can reduce both artifact and blurring generated by materials out of focal plane. To evaluate the quality of cross-sectional images, two evaluating criteria: (1) shape accuracy and (2) clearness in the cross-sectional image are defined. Based on this criteria, a series of simulations were performed, and the results show the superiority of the new synthesizing method over the existing ones such as averaging and minimum method.

  • PDF

Implementation of FlexRay Network System for Distributed Systems of Intelligent Vehicle (지능형 자동차의 분산형 시스템을 위한 FlexRay 네트워크 시스템의 구현)

  • Ha, Kyoung-Nam;Lee, Won-Seok;Lee, Kyung-Chang;Lee, Suk
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.13 no.10
    • /
    • pp.933-939
    • /
    • 2007
  • Safety critical systems such as x-by-wire systems require in-vehicle network systems that can interconnect various sensors, actuators, and controllers. These networks need to have high data rate, deterministic operation, and fault tolerance. Recently, FlexRay protocol that is a time-triggered protocol has been introduced, and many automotive companies have been focusing on this protocol. This paper presents a design method of FlexRay network system and implementation of FlexRay-based motor control system.