• Title/Summary/Keyword: ray.

Search Result 20,659, Processing Time 0.042 seconds

Unveiling the direct conversion X-ray sensing potential of Brucinium benzilate and N-acetylglcyine

  • T. Prakash;C. Karnan;N. Kanagathara;R.R. Karthieka;B.S. Ajith Kumar;M. Prabhaharan
    • Nuclear Engineering and Technology
    • /
    • v.56 no.6
    • /
    • pp.2190-2194
    • /
    • 2024
  • The study investigates the dose-dependent direct X-ray sensing characteristics of Brucinium benzilate (BB) and N-acetylglycine (NAG) organic crystals. BB and NAG were prepared as a slurry and deposited as a thick film on a patterned metal electrode. The X-ray induced photocurrent response was examined for various exposure doses using an intraoral pulsed 70 keV X-ray machine connected to a source meter. Subsequently, the morphological properties and thickness of the thick films were analyzed using scanning electron microscopy (SEM). At a photon energy of 70 keV, the attenuation coefficient values for NAG and BB crystals were determined to be approximately 0.181 and 0.178 cm2/g, respectively. The X-ray stopping power of the crystals was measured using a suniray-2 X-ray imaging system. To evaluate the responsiveness of the sensors, the photocurrent sensitivity and noise equivalent dose rate (NED) were calculated for both thick films. The findings demonstrated a noteworthy capability of sensing low doses (mGy), thereby suggesting the potential application of these organic materials in X-ray sensor development.

A study on Algorithm Automatically Generating Ray Codes for Ray-tracing (파선코드 자동생성 알고리즘에 관한 연구)

  • Lee, Hee-Il;Cho, Chang-Soo
    • Geophysics and Geophysical Exploration
    • /
    • v.11 no.4
    • /
    • pp.361-367
    • /
    • 2008
  • When constructing a synthetic seismogram in the earthquake study or in seismic data interpretation by using a ray-tracing technique, the most troublesome and error-prone task is to define a suite of ray codes for the corresponding rays to trace in advance. An infinite number of rays exist for any arbitrarily located source and receiver in a medium. Missing certain important rays or an inappropriate selection of ray codes in tracing rays may result in wrong interpretation of the earthquake record or seismogram. Automatic ray code generation could be able to eliminate those problems. In this study we have developed an efficient algorithm with which one can generate systematically all the ray codes for the source(s) and receiver(s) arbitrarily located in a model. The result of this work could be used not only in analysing multiples in seismic data processing and interpretation, but also in coda wave study, study on the amplification effects in a basin and phase identification of the waves multiply reflected/refracted in earthquake study.

Image System Using Dual Energy Detector (이중 에너지 검출기를 이용한 영상 시스템)

  • Yeo, Hwa-Yeon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.9
    • /
    • pp.3517-3523
    • /
    • 2010
  • Single exposure dual X-ray imaging can be used to separate soft and dense-material images for medical and industrial applications. This study keep focusing baggage inspection system(BIS) specifically. New detector modules for single exposure dual X-ray imaging are consisted of low energy detector (LED) and high energy detector (HED). First, the optimized thickness of copper filter coupled HED to separate low energy and high energy was simulated by the given X-ray energy (140 kVp, 1 mA) using Monte Carlo simulation codes, MCNPX. So as a result of simulation, the copper filter thickness is 0.7 mm. For the design of PIN photodiode, ATLAS device simulation tool was used. 16 channels PIN photodiode of 1.5 mm ${\times}$ 3.2 mm for Dual X-ray imaging detector was fabricated in the process of ETRI. And its dark current and quantum efficiency, terminal capacitance were measured. It was proven that the Lanex Fast B coupled HED were a sufficient candidate to replace the CsI(Tl) commerced in dual X-ray system, since these give a strong signal, overcoming system noise. Finally dual X-ray image was acquired through correction of the LED X-ray Image and the HED X-ray Image.

A 16kw Rotating Anode type Monoblock X-ray Generator (16kW 회전 Aonde형 모노블럭 X-선 발생장치)

  • Oh, Jun-Yong;Kim, Yuen-Chung;Kim, Hack-Seong
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.11 no.2
    • /
    • pp.97-103
    • /
    • 2006
  • This paper designs mono block type with rotating high power radiography x-ray generator and studies 16kW X-ray generator possible to adapt hospital mobile radiography and industrial X-ray equipment and design. This equipment uses rotating anode type x-ray tube at high voltage generator to generate x-ray and adds rotor operating circuit to operate rotor of x-ray tube. The size of high voltage transformer and high voltage generator is minimized by high voltage high frequency inverter has 100kHz switching frequency. Also this paper shows result of x-ray tube voltage and tube current correspond to variable load.

Comparison of Primary Breast Cancer Size by Mammography and Sonography

  • Wang, Jian-Tao;Chang, Li-Ming;Song, Xin;Zhao, Li-Xin;Li, Jun-Tao;Zhang, Wei-Guo;Ji, Ying-Bin;Cai, Li-Na;Di, Wei;Yang, Xin-Yu
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.22
    • /
    • pp.9759-9761
    • /
    • 2014
  • Purpose: To compare tumor size by mammography and sonography and align with pathological results in primary breast cancer cases. Materials and Methods: We retrospectively reviewed 95 primary breast cancer patients who underwent mammography and sonography from January 2011 to June 2012. The largest tumor diameter was chosen as sizing reference for each imaging modality. The measurements of mammography and sonography were considered concordant if they were within the measurement of pathological results ${\pm}0.5cm$. Pearson's correlation coefficient was calculated for imaging results. Results: The range of the maximum diameter was 0.6cm-10.5cm and mean value was $3.81{\pm}2.04cm$ by pathological results, 0.7cm-12.4 cm and $3.99{\pm}2.19cm$ by mammography, and 0.9cm-11.0cm and $3.63{\pm}2.01cm$ by sonography, respectively. Sonography (R: 0.754), underestimated tumor size, but had a better correlation with pathological tumor size compared to mammography (R: 0.676), which overestimated tumor size. Conclusions: Sonography is superior to mammography in assessment of primary breast cancer.

Irradiation of Intense Characteristic X-rays from Weakly Ionized Linear Plasma

  • Sato, Eiichi;Hayasi, Yasuomi;Tanaka, Etsuro;Mori, Hidezo;Kawai, Toshiaki;Takayama, Kazuyoshi;Ido, Hideaki
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.396-399
    • /
    • 2002
  • Intense quasi-monochromatic x-ray irradiation from the linear plasma target is described. The plasma x-ray generator employs a high-voltage power supply, a low-impedance coaxial transmission line, a high-voltage condenser with a capacity of about 200 nF, a turbo-molecular pump, a thyristor pulse generator as a trigger device, and a flash x-ray tube. The high-voltage main condenser is charged up to 55 kV by the power supply, and the electric charges in the condenser are discharged to the tube after triggering the cathode electrode. The x-ray tube is of a demountable triode that is connected to the turbo molecular pump with a pressure of approximately 1 mPa. As electron flows from the cathode electrode are roughly converged to the molybdenum target by the electric field in the tube, the weakly ionized plasma, which consists of metal ions and electrons, forms by the target evaporating. In the present work, the peak tube voltage was almost equal to the initial charging voltage of the main condenser, and the peak current was about 20 kA with a charging voltage of 55 kV. When the charging voltage was increased, the linear plasma x-ray source grew, and the characteristic x-ray intensities of K-series lines increased. The quite sharp lines such as hard x-ray lasers were clearly observed. The quasi-monochromatic radiography was performed by a new film-less computed radiography system.

  • PDF

Feasibility study of Hybrid X-ray detecter for Digital X-ray imaging application (디지털 방사선 적용을 위한 Hybrid 방사선 검출기의 Feasibility 연구)

  • Choi, Jang-Yong;Park, Ji-Koon;Lee, Chae-Hun;Lee, Kyu-Hong;Choi, Heung-Kook;Nam, Sang-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.04b
    • /
    • pp.77-80
    • /
    • 2004
  • In this study, the purpose is to verified the feasibility to develope Hybrid x-ray detector in order to resolve problems of direct and indirect x-ray detectors. The properties of X-ray detector depend on absorption of X-ray, charge generation by x-ray photon, leakage current. In this study, CdS was used as photoconductor, and $Y_2O_2S:Tb$ as x-ray phosphor was formed on CdS in order to embody Hybrid structure. And Screen printing was used to form Muli-layer. Characteristics of this specimen were analyzed by using SEM, and XRD. And Photoluminescence spectrum of $Y_2O_2S:Tb$, leakage current, with respect to applied voltages, output charge with respect to applied voltages, and X-ray sensitivity were measured. Also, linearity with respect to dose was measured. Leakage current was similar with direct digital x-ray detector, but sensitivity of the hybrid structure is much better than the single-layer structure.

  • PDF

이차전지 양극활물질의 chemical state 측정을 위한 X0ray Induced Electron Emission Spectroscopy (XIEES)의 활용

  • 이재철;송세안;임창빈
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2000.02a
    • /
    • pp.167-167
    • /
    • 2000
  • 전지 재료의 충방전 과정 연구에는 X-선 분말회절(x-ray powder diffraction techniques)과 중성자회절을 많이 사용하였다. 하지만 이러한 분석기술은 long-range order의 구조에 관한 정보를 제공하는데 유용하지만 atomic scale의 구조에 관한 정보를 얻기에는 한계가 있다. Li 전지에서의 전기화학적 반응에서는 cathode 물질에 포함된 전이금속의 산화, 환원 반응에 의한 Li 이온의 intercalation (charge process)과 deintercalation (discharge process) 현상이 일어난다. 이러한 충방전 과정은 알려지지 않은 다양한 형태의 위상 변화를 동반하게 되는데 x-선 이나 중성자를 이용한 powder diffraction techniques 로는 단지 정성적인 결정학적 정보를 얻을 수 있다. 따라서 최근에 원자 단위의 local structure에 관한 정보와 electrochemical state에 관한 정보를 동시에 얻을 수 있는 X-ray Absorption Fine Structure (XAFS) 분석기술을 Li 전지분석에 활용하기 시작하였다. XAFS는 하나의 x-ray 흡수원자에 대해서 주변원자들의 원자구조에 관한 정보와 구성 원소의 electrochemical state에 관한 정보를 얻을 수 있는 분석방법이다. X-ray Induced Electron Emission Spectroscopy (XIEES)는 x-ray에 의해서 방출된 전자를 검출하여 스펙트럼을 얻는 기능을 함축적으로 나타낸 것으로, x-ray를 물질 표면에 조사하여 발생하는 광전자, Auger 전자, 이차전자 등을 전자검출기(Channel Electron Multiplier: CEM)로 검출하는 기능과, 시료를 투과한 x-ray와 시료에서 발생하는 형광 x-ray를 비례계수기로 검출하는 기능을 가지고 있다. 이러한 검출 능력을 바탕으로 EXAFS, XANES, Standing Wave Technique, Elemental Composition Analysis, DXRD, Total Reflection Technique 등을 이용하여 물질을 구성하고 있는 원소의 성분, 미세원자구조, 전자구조에 관한 정보를 얻을 수 있는 새로운 spectrometer이다. 본 연구에서는 자체 개발한 XIEES의 XAFS 기능을 이용하여 여러 가지 방법으로 제조한 LiMn2-xO4와 LiMnO2, MnO2에서 Mn K-absorption edge에 대한 chemical state 변화를 측정하였다. Absorption edge에서 chemical shift를 측정하기 위해서는 방사광 가속기 수준의 에너지 분해능(~0.3eV)이 필요하다. 이번 연구에서는 SiO2(3140) monochromator를 사용하고 여기에 맞는 적절한 parameter를 적용하여 x-ray 에너지 분해능을 포항방사광가속기 수준으로 개선하였다. XIEES에서 얻은 스펙트럼과 포항방사광가속기에서 얻은 스펙트럼을 비교하였다. Chemical shift가 일어나는 경향은 두 실험 결과가 잘 일치하였다.

  • PDF

Feasibility study of insertable miniature x-ray source for dental imaging (치과 영상용 삽입형 초소형 X선 튜브의 가능성 연구)

  • Cho, Sung-Ho;Kim, So-Yeong;An, So-Hyun;Lim, Soo-Mee;Lee, Re-Na
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.1
    • /
    • pp.39-45
    • /
    • 2012
  • Conventional periphery radiography system has a various problem such as patient dose and the pain of X-ray examination. In this paper, to solve these problems, we suggested insertional miniature x-ray system and we verified the feasibility of this system. First, we performed the Geant4 x-ray simulation to design x-ray collimator and filter to use miniature x-ray tube and we decided optimized thickness of filter and collimator. Also, we measured x-ray spectrum using CdTe detector and PX4 module to verify simulation results. Also, we acquired teeth image of fabricated phantom using conventional dental x-ray and prosed miniature x-ray system. As a results, our system has good image quality as compared to those of conventional systems. Our evaluation of the proposed system indicates that it can be potentially very useful for dental imaging.

Quantitative Analysis of Skarn Ore Using 3D Images of X-ray Computed Tomography (3차원 X-ray 단층 화상을 이용한 스카른 광석의 정량분석 연구)

  • Jeong, Mi-Hee;Cho, Sang-Ho;Jeong, Soo-Bok;Kim, Young-Hun;Park, Jai-Koo;Kaneko, Katsuhiko
    • Journal of the Mineralogical Society of Korea
    • /
    • v.23 no.3
    • /
    • pp.211-217
    • /
    • 2010
  • A micro-focus X-ray computed tomography (CT) was employed to determine quantitative phase analysis of skarn Zn-Pb-Cu ore by nondestructive visualization of the internal mineral distribution of a skarn ore. The micro CT images of the ore were calibrated to remove beam hardening artifacts, and compared with its scanning electron microscope (SEM) images to set the threshold of CT number range covering sulfide ore minerals. The volume ratio of sulfide and gangue minerals was calculated 20.5% and 79.5%, respectively. The quantitative 3D X-ray CT could be applied to analyse the distribution of economic minerals and their recovery.