• Title/Summary/Keyword: ray.

Search Result 20,659, Processing Time 0.043 seconds

An Interesting Story of Four Gamma-ray Bright AGNs by the iMOGABA

  • Lee, Sang-Sung
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.43 no.1
    • /
    • pp.37.1-37.1
    • /
    • 2018
  • A Korean VLBI Network key science program, the Interferometric Monitoring of Gamma-ray Bright AGNs (iMOGABA) program continues to reveal the nature of the gamma-ray flares in active galactic nuclei (AGNs). Here in this presentation, we would like to introduce an interesting story about four gamma-ray bright AGNs - BL Lac, 1633+382, 3C 84, and M87 - based on the recent results of the iMGOABA. The results will include a) a sad story of an 'orphan' gamma-ray flare from BL Lac, b) a position offset of 40 pc for a gamma-ray flaring site from the radio regions in 1633+382, c) a position alignment of a gamma-ray flaring site with a central engine region in 3C 84, and d) a flat millimeter spectrum of a core in M87 revealed by the iMOGABA.

  • PDF

Image Quality Enhancement for Chest X-ray image (Chest X-ray 영상을 위한 화질 개선 알고리즘)

  • Park, So Yeon;Song, Byung Cheol
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2015.07a
    • /
    • pp.538-539
    • /
    • 2015
  • 일반 영상의 화질을 개선하기 위해 다양한 알고리즘이 존재한다. 하지만 X-ray 영상의 경우 일반 영상과 특성이 다르기 때문에 기존의 화질 개선 알고리즘으로는 진단에 적합한 화질을 얻을 수 없다. 디지털 X-ray 기기로부터 처음 획득된 X-ray 영상은 데이터 범위가 일반 영상에 비해 넓고 밝기 레벨이 고르지 못하다. 특히 Chest X-ray 영상의 경우 다양한 이유로 촬영하기 때문에 갈비뼈와 혈관, 척추 뼈 등 특성이 다른 모든 부위들을 자연스럽게 개선할 필요가 있다. 본 논문은 영상의 불필요한 배경 성분을 제거하여 특정 밝기에 밀집되어 있는 데이터들의 히스토그램 범위를 확장시키고 주파수 대역 별 가중치를 조절하여 대비 및 선명도를 향상시킨다. 마지막으로 전역적 대비 개선 기법과 지역적 대비 개선 기법의 장점을 취하여 진단에 적합하도록 개선된 Chest X-ray 영상을 얻는다.

  • PDF

Feasibility Study on Development of an Underwater Beta-ray Monitoring Sensor (수중 내 베타선 모니터링 센서 개발을 위한 기초연구)

  • Park, Hye Min;Joo, Koan Sik
    • Journal of Sensor Science and Technology
    • /
    • v.25 no.5
    • /
    • pp.333-336
    • /
    • 2016
  • In this study, a beta monitoring sensor was developed as a part of basic research for quantitative beta monitoring underwater, and its performance was evaluated using a calibration source. A beta detection sensor was manufactured by using SiPM(silicon photomultiplier) and $CaF_2$:Eu, YAG:Ce, YAP:Ce scintillator. A large-area light guide was introduced to improve beta-ray detection efficiency. As calibration sources, the Beta source $^{90}Sr$, which is the main fission product of a nuclear accident, and the gamma source $^{137}Cs$ are used. In the performance evaluation, it is confirmed that scintillator $CaF_2:Eu$ gives the highest beta-ray detection response. Compared to gamma ray, beta-ray detection responsivity and detection efficiency are verified. Therefore, this study is expected to contribute to basic research in the development of an underwater beta-ray monitoring system.

Automated Detection of Pulmonary Nodules in Chest X-ray Radiography Using Genetic Algorithm (흉부 X-ray 영상에서 유전자 알고리즘을 이용한 폐 결절 자동 추출)

  • 류지연;이경일;장정란;오명진;이배호
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2002.10d
    • /
    • pp.553-555
    • /
    • 2002
  • 컴퓨터지원진단(Computer Aided Diagnosis; CAD) 시스템은 방사선 의사들이 흉부 X-ray 영상에서 결절을 탐지하는데 있어 실제적으로 발생할 수 있는 오진율을 줄이고, 폐 결절이 존재하는 폐야에서 결절의 존재 유무를 판단하여 검출을 표시함으로써 진단율을 개선시킬 수 있도록 하였다. 본 논문은 흉부 X-ray 영상에서의 폐 결절을 추출하는데 유전자 알고리즘(Genetic Algorithm)을 이용한 템플릿 매칭(Template Matching) 방법을 제안한다. 제안한 방법은 흉부 X-ray 영상에 존재하는 결절과 레퍼런스 이미지를 매칭시켜 적합도를 계산한 후, 그 값을 통하여 수치가 낮은 개체를 선택하여 높은 개체와 교차시킨다. 그리고 레퍼런스 이미지는 결절이 존재하는 환자 X-ray 영상에서 샘플 노듈을 추출한 후 가우시안 분포를 갖는 512개의 레퍼런스 이미지를 생성하였다. 본 논문에서 사용된 영상은 결절 50개, 비결절 30개와 흉부 X-ray 영상에서 육안으로 판별이 가능한 결절 영상을 20개를 포함하여 총 100개 영상을 사용하였다. 실험 결과 83%의 결절을 자동 추출 하였으며, 가장 적절한 레퍼런스 이미지를 발견하고 이를 흉부영상에 매칭시켜 정확한 결절의 위치를 확인하였다.

  • PDF

Modified Ray-space Interpolation for Free Viewpoint Video System (Free Viewpoint 비디오 시스템을 위한 Ray-space 보간 기법 보완 연구)

  • Seo, Kang-Uk;Kim, Dong-Wook;Kim, Hwa-Sung;Yoo, Ji-Sang
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2006.11a
    • /
    • pp.41-43
    • /
    • 2006
  • FTV (Free Viewpoint TV, 자유시점 TV)는 사용자들이 원하는 시점을 자유자재로 결정할 수 있는 차세대 TV이다. 또한 영상 획득 시 카메라가 위치하지 않은 새로운 시점을 만들 수 있다. 따라서 FTV는 개인, 산업, 사회, 의학. 사회 분야의 유망한 응용이 될 수 있다. Ray-space에 의한 데이터 표현은 FTV를 위한 데이터 포맷의 한 후보가 될 수 있으며, 실시간으로 임의시점의 영상을 구성하는 데에 있어서 우수한 장점을 가지고 있다. Ray-space에서 사용하는 기법은 컴퓨터 그래픽스가 아니라 순수한 신호 처리 방식이다. 스케일러블 구조, 계층적 구조가 Ray-space로 표현 가능하므로, Ray-space는 비디오 처리의 새로운 플랫폼을 구성할 수 있고 비디오의 개념을 확장할 수 있다. 본 논문에서는 Ray-space 데이터를 이용하여 임의 시점 영상을 생성하기 위해 기존의 보간(interpolation) 기법을 보완한 새로운 기법을 제안함으로써, 보다 자연스러운 영상을 얻고자 하는데 목적이 있다.

  • PDF

A New Approach on the Correction for Compton Escape Component in X-Ray Unfolding Algorithm

  • Kim, Soon-Young;Kim, Jong-Kyung
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1995.05a
    • /
    • pp.925-930
    • /
    • 1995
  • A new approach on the correction for Compton escape component in X-ray unfolding algorithm was investigated to obtain more accurate X-ray source spectrum. The X-ray detector used in this study was a planar type HPGe detector(EG&G ORTEC, GLP-32340/13-P-LP) whose energy response has been blown and ISO narrow beam series were employed as source spectrum. At lower energy Part of measured X-ray spectrum including the correction for Compton escape component more accurate unfolded spectrum was obtained by letting down the starting energy level of the collection in existing spectrum correction procedure to consider multiple scattering effects. It is, from this study, concluded that accurate correction for Compton escape component is needed in X-ray unfolding procedure since Compton scattering becomes more important as incident X-ray energies increase.

  • PDF

Real-time X-ray Scattering as a Nanostructure Probe for Organic Photovoltaic Thin Films

  • Lee, Hyeon-Hwi;Kim, Hyo-Jeong;Kim, Jang-Ju
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.181-181
    • /
    • 2013
  • Recently, nanostructure and the molecular orientation of organic thin films have been largely paid attention due to its importance in organic electronics such as organic thin film transistors (OTFTs), organic light emitting diodes (OLEDs), and organic photovoltaics (OPVs). Among various methods, the diffraction and scattering techniques based on synchrotron x-rays have shown powerful results in organic thin film systems. In this work, we introduce the in-situ annealing system installed at PLS-II (Pohang Light Source II) for organic thin films by simultaneously conducting various x-ray scattering measurements of x-ray reflectivity, conventional x-ray scattering, grazing incidence wide angle x-ray scattering (GI-WAXS) and so on. Using the in-situ measurement, we could obtain real time variation of nanostructure as well as molecular orientation during thermal annealing in metal-phthalocyanine thin films. The variation of surface and interface also could be simultaneously investigated by the x-ray reflectivity measurement.

  • PDF

Plain Chest X-ray Diagnosis of Respiratory Disease (호흡기 질환에서 단순흉부 X-선 진단)

  • Kim, Sang-Jin
    • Tuberculosis and Respiratory Diseases
    • /
    • v.40 no.4
    • /
    • pp.353-356
    • /
    • 1993
  • Advent of new imaging modalities such as computed tomography, magnetic resonance imaging and ultrasound contributed greately to the specific imaging diagnosis. However plain chest X-ray is still most prequently used for imaging diagnosis of respiratory disease in clinical pratic and it is important to make a good quality of X-ray film and good interpretation. The optimal chest X-ray should be taken with full inspiration without rotation and motion and the exposure is at the level of barely demonstrable thoracic vertebral disc space. It is recommended that higk KVP technique for detection of lesions which is overlaped by mediastinum, heart and rib cage. It is better to examine chest X-ray film start at some distance(6-8 feet) and closer to the film later on and the reader should not read a film in fatigue condition. The reading room should be quiet and relately dark illumination. It is important, to make a good X-ray film and good interpretation to reduce the observer error.

  • PDF

Interfacial diffusion in Fe/Cr magnetic multilayers studied by synchrotron x-ray techniques (다층형 Fe/Cr 자성박막에서 계면확산의 방사광 x-선 연구)

  • Cho, Tae-Sik;Jeong, Ji-Wook
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.05a
    • /
    • pp.84-87
    • /
    • 2003
  • The interfacial diffusion in Fe/Cr/MgO(001) multilayers has been studied using synchrotron x-ray techniques, such as x-ray reflectivity, extended x-ray absorption fine structures (EXAFS), and anomalous x-ray scattering (AXS). The results of x-ray reflectivity indicated that the interfacial roughness of Fe/Cr multilayers with Cr-$4{\AA}$-thick was larger than that with Cr-$4{\AA}$-thick. The results of EXAFS indicated that the Fe element dominantly diffuse into the stable Cr layers at the Fe/Cr interface. The AXS was certified the existence of the interdiffused Fe element in the Cr layers. Our study revealed that the rough interface of the Fe/Cr multilayers was caused by the interfacia diffusion of Fe element into the Cr layers.

  • PDF

Exploring Fine Structures of Photoactive Yellow Protein in Solution Using Wide-Angle X-ray Scattering

  • Kim, Tae-Kyu;Zuo, Xiaobing;Tiede, David M.;Ihee, Hyot-Cherl
    • Bulletin of the Korean Chemical Society
    • /
    • v.25 no.11
    • /
    • pp.1676-1680
    • /
    • 2004
  • We demonstrate that wide-angle X-ray scattering pattern from photoactive yellow protein (PYP) in solution using a high flux third generation synchrotron X-ray source reflects not only the overall structure, but also fine structures of the protein. X-ray scattering data from PYP in solution have been collected in q ranges from 0.02 ${\AA}^{-1}$ to 2.8 ${\AA}^{-1}$. These data are sensitive to the protein structure and consistent with the calculation based on known crystallographic atomic coordinates. Theoretical scattering patterns were also calculated for the intermediates during the photocycle of PYP to estimate the feasibility of time-resolved wide-angle X-ray scattering experiments on such proteins. These results demonstrate the possibility of using the wide-angle solution X-ray scattering as a quantitative monitor of photo-induced structural changes in PYP.