• Title/Summary/Keyword: ray number

Search Result 1,137, Processing Time 0.023 seconds

Studies on the Wood Rays in Coniferous Woods - Mutural Relation on the Indicators of Wood Rays in Coniferous Woods - (침엽수재(針葉樹材)의 방사조직(放射組織)에 관(關)한 연구(硏究) - 방사조직지표치(放射組織指標値)의 상호관련성(相互關聯性)-)

  • Lee, Weon-Yong
    • Journal of the Korean Wood Science and Technology
    • /
    • v.15 no.2
    • /
    • pp.90-98
    • /
    • 1987
  • In the present paper I described the relations of wood ray indicators such as ray height, ray width, number of rays per $0.25mm^2$, ray spacing and fusiform ray height on the stem of Pinus koraiensis and Larix leptolepis grown at the Experiment Forest of Kangweon National University. The results may be summarized as follows. 1. The number of rays and ray spacing were generally decreased with the increase of ray height on the sample woods. 2. According to the tree species the patterns of varition of ray width with the increase of ray height were different, namely the relation between ray width and ray height showed some positive correlation on Pinus koraiensis and negative on Larix leptolepis. 3. It was recognized that the variation of fusiform ray height due to the increase of ray height indicated two patterns(the increasing, md constant regions) in sample woods. This boundary seemed to appear at six cells of ray height on Pinus koraiensis and ninc cells on Larix leptolepis. 4. The relation between fusiform ray height and number of rays had a negative correlation on Pinus koraiensis, but this tendancy was not obvious on Larix leptolepis. And ray spacing and ray width due to the increase of fusiform ray height were generally decreased. 5. On the whole the values of ray spacing and ray width became gradually larger in proportion to the increase of number of rays. 6. According to the increase of ray spacing the values of ray width also increased gradually. But this tendency was more clear on Pinus koraiensis than larix leptolepis.

  • PDF

Quality Control of Diagnostic X-ray Equipment in Medical Field (의료분야 진단용방사선발생장치의 품질관리)

  • Cho, Pyong-Kon
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.2
    • /
    • pp.159-164
    • /
    • 2021
  • The examination using diagnostic x-ray equipment is one of the most useful diagnostic equipment for identifying information in the human body in diagnostic radiology. For this reason, the number of examinations has recently increased a lot. Increasing the number of examinations will accelerate the aging of the device. In addition, this makes them aware of the importance of quality control for the diagnostic x-ray device. Particularly, in a diagnostic x-ray device, quality control refers to an act of always maintaining a certain level of image quality by identifying and correcting all problems that may lead to reduction of the diagnosis area in advance. Therefore, this study summarizes and reports general information about quality control in examinations using diagnostic x-ray equipment.

A Study on the Prediction of Fatigue Life in 2024-T3 Aluminium using X-ray Half-Value Breadth (X선 반가폭을 이용한 Al 2024-T3 합금의 피로수명예측에 관한 연구)

  • 조석수;김순호;주원식
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.17 no.1
    • /
    • pp.145-152
    • /
    • 2000
  • X-ray diffraction method detects change of crystal lattice distance under material surface using diffraction angle 2$\theta$. This technique can be applied to the behavior on slip band and micro crack due to material degradation. The relation between half-value breadth and number of cycle has three stages which constitute rapid decrease in initial number of cycles, slight decrease in middle number of cycles and rapid decrease in final number of cycles. The ratio of half-value breadth takes a constant value on B/B$_{0}$-N diagram with loading condition except early part of fatigue life. The ratio of half-value breadth B/B$_{0}$ with respect to number of cycle to failure N$_{f}$ has linear behavior on B/B$_{0}$-log N$_{f}$ diagram. Therefore, in this paper the estimation of fatigue life by average gradient method has much less estimated mean error than the estimation of fatigue life by log B/B$_{0}$-log N/N$_{f}$ relation.elation.ation.

  • PDF

Development Changes of Cambial Initials and Their Derivative Cells in the Trunk of Diospyros kaki THUNB. and Firmiana simplex W.F. WIGHT in Relation to Girth Increase (감나무와 벽오동 수간의 둘레증가에 따른 형성층 원시세포와 그 유도세포의 발생학적 변화)

  • 한경식
    • Journal of Plant Biology
    • /
    • v.34 no.3
    • /
    • pp.191-199
    • /
    • 1991
  • This study has been conducted to investigate the developmental changes of cambial initials and their derivatives in relation to the growing girth of tree in Diosypros kaki and Firmiana simplex. In D. Kaki and F. simplex with typical storeyed cambium, increase in the girth of camium occurred by radial anticlinal division in general, however occasionally the increase was companied by pseudotransverse division. The length of fusiform initials, vessel member, and sieve tube member remained relatively constant throughout the secondary growth but that of fiber showed general tendancy to increase with growing girth of tree. During the girth increase of tree, height and number of ray remained constant in D. kaki, however in F. simplex, height of ray markedly decreased while the number of ray per unit area more or less increased. The secondary ray was originated from the segmentation or division of the side or end of fusiform initials.

  • PDF

Performance Evaluation of ResNet-based Pneumonia Detection Model with the Small Number of Layers Using Chest X-ray Images (흉부 X선 영상을 이용한 작은 층수 ResNet 기반 폐렴 진단 모델의 성능 평가)

  • Youngeun Choi;Seungwan Lee
    • Journal of radiological science and technology
    • /
    • v.46 no.4
    • /
    • pp.277-285
    • /
    • 2023
  • In this study, pneumonia identification networks with the small number of layers were constructed by using chest X-ray images. The networks had similar trainable-parameters, and the performance of the trained models was quantitatively evaluated with the modification of the network architectures. A total of 6 networks were constructed: convolutional neural network (CNN), VGGNet, GoogleNet, residual network with identity blocks, ResNet with bottleneck blocks and ResNet with identity and bottleneck blocks. Trainable parameters for the 6 networks were set in a range of 273,921-294,817 by adjusting the output channels of convolution layers. The network training was implemented with binary cross entropy (BCE) loss function, sigmoid activation function, adaptive moment estimation (Adam) optimizer and 100 epochs. The performance of the trained models was evaluated in terms of training time, accuracy, precision, recall, specificity and F1-score. The results showed that the trained models with the small number of layers precisely detect pneumonia from chest X-ray images. In particular, the overall quantitative performance of the trained models based on the ResNets was above 0.9, and the performance levels were similar or superior to those based on the CNN, VGGNet and GoogleNet. Also, the residual blocks affected the performance of the trained models based on the ResNets. Therefore, in this study, we demonstrated that the object detection networks with the small number of layers are suitable for detecting pneumonia using chest X-ray images. And, the trained models based on the ResNets can be optimized by applying appropriate residual-blocks.

Image Quality Evaluation according to X-ray Source Arrangement Type and the Number of Projections in a s-IGDT System (s-IGDT 시스템의 X-선원 배열 형태 및 투영상 개수에 따른 영상 화질 평가에 관한 연구)

  • Lee, Dahye;Nam, KiBok;Lee, Seungwan
    • Journal of radiological science and technology
    • /
    • v.45 no.2
    • /
    • pp.117-125
    • /
    • 2022
  • Although stationary inverse-geometry digital tomosynthesis (s-IGDT) is able to reduce motion artifacts, image acquisition time and radiation dose, the image quality of the s-IGDT is degraded due to the truncations arisen in projections. Therefore, the effects of geometric and image acquisition conditions in the s-IGDT should be analyzed for improving the image quality and clinical applicability of the s-IGDT system. In this study, the s-IGDT images were obtained with the various X-ray source arrangement types and the various number of projections. The resolution and noise characteristics of the obtained s-IGDT images were evaluated, and the characteristics were compared with those of the conventional DT images. The s-IGDT system using linear X-ray source arrangement and 40 projections maximized the image characteristics of resolution and noise, and the corresponding system was superior to the conventional DT system in terms of image resolution. In conclusion, we expect that the s-IGDT system can be used for providing medical images in diagnosis.

Detection Probabilities of the X-ray Point Sources in X-ray Extended Sources

  • Kim, Min-Sun;Kim, Eun-Hyeuk
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.35 no.2
    • /
    • pp.33.2-33.2
    • /
    • 2010
  • Galaxy clusters are known to be very bright in X-ray and contain a large number of X-ray point sources within the X-ray emission. However, due to the fluctuations of the X-ray emission, it is very difficult to detect faint X-ray sources and to extract accurately the photometric properties of the X-ray point sources in galaxy clusters. In addition, the most X-ray telescopes show spatially varying point spread function (PSF) and suffer from severe vignetting. The Chandra Archival Survey of Galaxy Clusters project is a wide-area ($\sim40deg^2$) survey of serendipitous Chandra X-ray sources in galaxy cluster fields, containing ~58,000 X-ray point sources in ~800 Chandra ACIS observations of ~600 galaxy clusters. This project aim to investigate the density environmental effects on the physical properties of the X-ray point sources, comparing physical properties of the X-ray point sources in galaxy clusters to those in typical fields. To utilize the sensitivity and detection probability of the X-ray point sources in galaxy clusters, we perform extensive Monte-Carlo simulations. In this poster, we compare the detection probability of the X-ray point sources in galaxy clusters to that of typical fields, and discuss quantitatively the difference between them.

  • PDF

Material Estimation Method Using Dual-Energy X-Ray Image for Cargo Inspection System (화물 검색 시스템을 위한 듀얼 에너지 X-ray 검색기 영상을 이용한 물질 추정 방법)

  • Lee, TaeBum;Kang, HyunSoo
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.23 no.1
    • /
    • pp.1-12
    • /
    • 2018
  • This paper presents a material estimation method using dual-energy X-ray images generated as a result of cargo inspection system in MeV region. We use new discrimination curve using logarithmic function rather than four discrimination curves commonly used in existing estimation algorithms. We also propose an atomic number estimation using the probability distribution of the logarithmic curve rather than linear interpolation. When the probability distribution is used as a weight, we used two methods of using the weight for the two nearest reference materials and the weight for all the reference materials. Experimental results showed that the atomic number estimation of materials using the probability distribution as a weight is more accurate than the existing methods. In order to visualize the estimated atomic number, the HSI model was used for color the resulting image.

Quantitative Evaluation of Concrete Damage by X-ray CT Methods (마이크로 포커스 X-ray CT를 이용한 콘크리트 손상균열의 정량적 평가)

  • Jung, Jahe
    • The Journal of Engineering Geology
    • /
    • v.28 no.3
    • /
    • pp.455-463
    • /
    • 2018
  • This study developed a method to quantitatively measure the size of cracks in concrete using X-ray CT images. We prepared samples with a diameter of 50 mm and a length of 100 mm by coring cracked concrete block that was obtained by chipping. We used a micro-focus X-ray CT, then applied the 3DMA method (3 Dimensional Medial axis Analysis) to the 3D CT images to find effective parameters for damage assessment. Finally, we quantitatively assessed the damage based on sample locations, using the damage assessment parameter. Results clearly show that the area near the chipping surface was damaged to a depth of 3 cm. Furthermore, X-ray methods can be used to evaluate the porosity index, burn number, and medial axis, which are used to estimate the damage to the area near the chipping surface.

Correlation between the Portable X-ray and the Radiation Exposure dose in the Emergency Department: Cohort Study (응급실에서 이동식 단순 X-선 검사와 피폭선량과의 상관관계: 코호트 연구)

  • Kim, Yu Jung;Ahn, Hee Cheol;Sohn, You Dong;Ahn, Ji Yoon;Park, Seung Min;Lee, Won Woong;Lee, Young Hwan
    • Journal of The Korean Society of Clinical Toxicology
    • /
    • v.11 no.2
    • /
    • pp.101-105
    • /
    • 2013
  • Purpose: This study was conducted in order to determine the relationship between the number of portable X-rays and the radiation exposure dose for emergency medical service providers working in the emergency department (ED). Methods: A prospective study was conducted from February 15, 2013 to May 15, 2013 in the ED in an urban hospital. Six residents, seven emergency medical technicians (EMT), and 24 nurses were enrolled. They wore a personal radiation dosimeter on their upper chest while working in the ED, and they stayed away from the portable X-ray unit at a distance of at least 1.8 m when the X-ray beam was generated. Results: The total number of portable x-rays was 2089. The average total radiation exposure dose of emergency medical service providers was $0.504{\pm}0.037$ mSv, and it was highest in the EMT group, 0.85(0.58-1.08) mSv. The average of the total number of portable X-rays was highest in the doctor group, 728.5(657.25-809). The relationship between the number of portable X-rays and the radiation exposure dose was not statistically significant(-0.186, p=0.269). Conclusion: Under the condition of staying away from the portable X-ray unit at a distance of least 1.8 m, the relationship between the number of portable X-rays and the radiation exposure dose was not statistically significant.

  • PDF