• Title/Summary/Keyword: ray number

Search Result 1,132, Processing Time 0.032 seconds

Gamma Irradiation Effects on Conchospores of Porphyra Species 2. The Effects of High Gamma Irradiation on Germination and Growth of Conchospores of Two Varieties (김의 각포자에 대한 r-선의 조사효과 2. 두 품종의 각포자의 발아생장에 미치는 고선량 r-선의 조사효과)

  • KIM Joong-Rae
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.18 no.1
    • /
    • pp.52-56
    • /
    • 1985
  • For the fundamental studies of radiation breeding in edible marine algae, the biological effects on conchospores of Porphyra species by gamma-irradiation were examined. Two varieties, Keun-cham-gim (Porphyra tenera Kjell. form tamatsuensis Miura) and Saga No.5, were chosen for this study, and their conchospores after r-irradiation($5.0{\sim}20.0$ KR) were cultured for 50 days. The results obtained were summarized as follows. 1. Gamma-irradiation in less than the dose of 20KR did not affect germination of conchospores, and almost all spores grew into two cells germ in 24 hours after irradiation, but withering germs were gradually increased in number according to higher exposure within 5 days old culture. 2. High irradiation caused the induction of giant cells, abnormal useless growth of hold-fast, lumpish thalli and callus-like lumpy tissues. 3. The liberation of neutral spores from young germs and carpospores from mature thalli were observed on the frond exposed at $10{\sim}20$ KR irradiation. All spores were normal in division and its size. 4. The best irradiation effect on growth of Keun-cham-gim was observed at 10 KR dose, whose growth-rates were $140\%$ in wet weight and $108\%$ in mean frond area, but only $48\%$ was recorded in wet weight at 20 KR exposure. Saga No.5 were in contrast with Keun-cham-gim, and their most growth-rate was $400\%$ in wet weight ($258\%$ in frond area) at 10 KR irradiation and the worst was $20\%$ at the dose of 20 KR. 5. The withering phenomenon to death by treatment of gamma-ray presented substantial difference between two varieties. Survival rate compared with control in Keun-cham-gim was $70.7\%$ at 20 KR, but that in Saga No.5 recorded $47.0\%$ at same dose. 6. Synthesizing the results of high and low r-irradiation, it was suggested tat high r-irradiation in more than 5.0 KR inhibited conspicuously the growth of germs derived from conchospores, and about half of them withered at 15.0 KR dose or more.

  • PDF

THE EFFECT OF LOW DIETARY CALCIUM AND IRRADIATION ON MANDIBLE IN RATS (저칼슘식이와 방사선조사가 백서 악골에 미치는 영향의 실험적 연구)

  • Lee Sun-Ki;Lee Sang-Rae
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.23 no.2
    • /
    • pp.229-250
    • /
    • 1993
  • This study was performed to investigate the morphological and structural changes of bone tissues and the effects of irradiation on the mandibular bodies of rats which were fed low calcium diets. In order to carry out this experiment, 160 seven-week old Sprague-Dawley strain rats weighing about 150 gm were selected and equally divided into one normal diet group of 80 rats and one low calcium diet group with the remainder. These groups were then subdivided into two groups, 40 were assigned rats for each subdivided group, exposed to radiation. The Group 1 was composed of forty non-irradiated rats with normal diet, Group 2 of forty irradiated rats with normal diet, Group 3 forty non-irradiated rats with low calcium diet, and Group 4 forty irradiated rats with low calcium diet. The two irradiation groups received a single dose of 20 Gy on the jaw area only and irradiated with a cobalt-50 teletherapy unit. The rats with normal and low calcium diet groups were serially terminated by ten on the 3rd, the 7th, the 14th, and the 21st day after irradiation. After termination, both sides of the dead rats mandible were removed and fixed with 10% neutral formalin. The bone density of mandibular body was measured by use of bone mineral densitometer(Model DPX -alpha, Lunar Corp., U.SA). Triga Mark ill nuclear reactor in Korea Atomic Research Institute was used for neutron activation and then calcium contents of mandibular body were measured by using a 4096 multichannel analyzer (EG and G ORTEC 919 MCA, U.SA). Also the mandibular body was radiographed with a soft X-ray apparatus(Hitex Co., Ltd., Japan). Thereafter, the obtained microradiograms were observed by a light microscope and were used for the morphometric analysis using a image analyzer(Leco 2001 System, Leco Co., Canada). The morphometric analysis was performed for parameters such as the total area, the bone area, the inner and outer perimeters of the bone. The obtained results were as follows: 1. In the morphometric analysis, total area and outer perimeter of the mandibular bodies of Group 3 were a little smaller than that of Group 1. The mean bone width and bone area were much smaller than that of Group 1 and the inner perimeter of Group 3 was much longer than that of Group 1. The total area and outer perimeter of Group 2 and Group 4 showed little difference. The mean bone width and bone area of Group 4 were smaller than that of Group 2 and the inner perimeter of Group 4 was longer than that of Group 2. 2. The remarkable decreases of the number and thickness of trabeculae and also the resorption of endosteal surface of cortical bone could be seen in the microradiogram of Group 3, Group 4 since the 3rd day of experiment. On the 21st day of experiment, the above findings could be more clearly seen in Group 4 than in Group 3. 3. The bone mineral density of Group 3 was lesser than that of Group 1 and the bone mineral density of Group 4 was lesser than that of Group 2 on the 7th, 14th, 21st days. The irradiation caused the bone mineral density to be decreased regardless of diet. In the case of Groups with low calcium diet, the bone mineral density was much decreased on the 21st day than on the 3rd day of experiment. 4. The calcium content in mandible of Group 3 was smaller than that of Group 1 throughout the experiment. roup 4 showed the least amount of calcium content. The irradiation caused the calcium content to be decreased regardless of diet. In the case of Groups with low calcium diet, the calcium content was much decreased on the 21st day than on the 3rd day of experiment. In conclusion, the present study demonstrated that morphological changs and decrease of bone mass due to resorption of bone by low calcium diet, and that the resorption of bone could be found in the spongeous bone and endosteal surface of cortical bone. So the problem of resorption of bone must be considered when the old and the postmenopausal women are taken radiotherapy because the irradiation seems to be accelerated the resorption of osteoporotic bone.

  • PDF

A Study of Optimized MRI Parameters for Polymer Gel Dosimetry (중합체 겔 선량측정법을 위한 최적의 자기공명영상 변수에 관한 연구)

  • Cho, Sam-Ju;Chung, Young-Lip;Lee, Sang-Hoon;Huh, Hyun-Do;Choi, Jin-Ho;Park, Sung-Ill;Shim, Su-Jung;Kwon, Soo-Il
    • Progress in Medical Physics
    • /
    • v.23 no.2
    • /
    • pp.71-80
    • /
    • 2012
  • In order to verify exact dose distributions in the state-of-the-art radiation techniques, a newly designed three-dimensional dosimeter and technique has been took strongly into consideration. The main purpose of our study is to verify the optimized parameters of polymer gel as a real volumetric dosimeter in terms of the various study of MRI. We prepared a gel dosimeter by combing 8% of gelatin, 8% of MAA, and 10 mM of THPC. We used a Co-60 gamma-ray teletherapy unit and delivered doses of 0, 2, 4, 6, 8, 10, 12, and 14 Gy to each polymer gel with a solid phantom. We used a fast spin-echo pulse to acquire the characterized T2 time of MRI. The signal noise ratio (SNR) of the head & neck coil was a relatively lower sensitivity than the body coil; therefore the dose uncertainty of head & neck coil would be lower than body coil's. But the dose uncertainty and resolution of the head & neck coil were superior to the body coil in this study. The TR time between 1,500 ms and 2,000 ms showed no significant difference in the dose resolution, but TR of 1,500 ms showed less dose uncertainty. For the slice thickness of 2.5 mm, less dose uncertainty of TE times was at 4 Gy, as well, it was the lowest result over 4 Gy at TE of 12 ms. The dose uncertainty was not critical up to 6 Gy, but the best dose resolution was obtained at 20 ms up to 8 Gy. The dose resolution shows the lowest value was over 20 ms and was an excellent result in the number of excitation (NEX) of three. The NEX of two was the highest dose resolution. We concluded that the better result of slice thickness versus NEX was related to the NEX increment and thin slice thickness.

A Case of Rifampicin Induced Pseudomembranous Colitis (Rifampicin에 의한 위막성 대장염 1예)

  • Yun, Jong-Wook;Hwang, Jung-Hye;Ham, Hyoung-Suk;Lee, Han-Chul;Roh, Gil-Hwan;Kang, Soo-Jung;Suh, Gee-Young;Kim, Ho-Joong;Chung, Man-Pyo;Kwon, O-Jung;Rhee, Chong-H.;Son, Hee-Chung
    • Tuberculosis and Respiratory Diseases
    • /
    • v.49 no.6
    • /
    • pp.774-779
    • /
    • 2000
  • Pseudomembranous colitis, although uncommon, is an important complication of antibiotics that is related to a variety of deleterious effects on the gastrointestinal tract. Rifampicin is one of the 1st line agents in the treatment of tuberculosis and a large number of patients are exposed to its potential adverse effects. We report upon a patient that had diarrhea due to pseudomembranous colitis after receiving antitubeculous medication, and which was probably caused by rifampicin. A 77-year-old man was admitted with diarrhea of three weeks duration. One month previously, he suffered from left pleuritic chest pain and left pleural effusion was noticed at chest X-ray. One week prior to the onset of diarrhea, he was started on empirically isoniazid, rifampicin, ethambutol and pyrazynamide as antituberculous medication. On admission, he complained of diarrhea, left pleuritic chest pain, dyspnea and sputum. On physical examination, breathing sound was decreased in the left lower lung field and bowel sound increased. Pleural biopsy revealed chronic granulomatous inflammation, which was compatible with tuberculosis, Sigmoidoscopy showed whitish to yellowish pseudomembrane with intervening normal mucosa, and his stool was positive for C.difficle toxin. He was diagnosed as pseudomembranous colitis and treated with oral metronidazole and vancomycin. The diarrhea did not recur after reinstitution of the anti-tuberculous medication without rifampicin inpatients with severe diarrhea receiving anti-tuberculous medication, rifampicin induced pseudomembranous colitis should be excluded.

  • PDF

Evaluation on the radiation exposure from activated wedge filter (10MV 이상 고에너지 사용시 wedge filler의 방사화가 작업환경에 미치는 영향평가)

  • Lee HwaJung;Kim DaeYoung;Kim WonTaek;Lee KangHyeok
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.16 no.2
    • /
    • pp.69-79
    • /
    • 2004
  • In the process of photon treatments, linear accelerators with energies higher than 10 MV produce neutrons through the (${\gamma}$, n) interactions with the composite materials of the linac head md these materials further produce the induced radiations. We investigate the possible risks from these induced radiations especially in the wedge filters to the radiation workers. Wedge filters are used to modify the isodose profiles in the radiation treatment using the linear accelerator and always be handled by the radiation workers. For the background radiation, we measured the radiation in both the waiting room and the outside of the building for two hospitals, S and H. The results of S hospital were $0.11\;{\mu}Sv/hr$ and $0.10\;{\mu}Sv/hr$ for waiting room and outside respectively, and in the case of H hospital, they were $0.12\;{\mu}Sv/hr$ and $0.11\;{\mu}Sv/hr$. Using a survey meter, we measured the radiation from wedge filters inserted in 10 MV and 15 MV Siemens linear accelerators. The time series measurements were done in ${\sim}1$ minutes after exposure of 5 Gy of monitor units for the field size of $25{\times}25cm^2$. The starting value of 10 MV machine was about $3.26\;{\mu}Sv/hr$, which was three times higher than that of 10 MV. The measured radiation was from $^{28}Al$ and $^{53}Fe$ with a half life of 3.5 min. If the treatment patients are $20{\sim}50$ per day and the number of process of wedge filter change per patient is one or two, the annual dose equivalent is $0.08{\sim}0.4\;mSv$ for 10 MV, and $0.27{\sim}1.36\;mSv$ for 15 MV, which are in the range of dose equivalent limits of radiation workers.

  • PDF

Ground Security Activities for Prevention of Aviation Terrorism -Centered on San Francisco International Airport of the U.S.A.- (항공테러방지를 위한 지상 보안활동 -미국 샌프란시스코국제공항을 중심으로-)

  • Kang, Maeng-Jin;Kang, Jae-Won
    • The Journal of the Korea Contents Association
    • /
    • v.8 no.2
    • /
    • pp.195-204
    • /
    • 2008
  • With the growth of airline management, as well as computer and IT security, the international trade in this modern society has been rapidly increasing, Along with the advancing, airplanes have become a universal means of communication. However, the complications associated with airplane safety have also been brought up as a result, the most concerning of which is terrorism. One of the main counterplans for preventing terrorism is Ground security activities the core of Ground security activities is absolute safety for passengers in both passenger terminal and freight terminal. Subastral security refers to physical protection, proximity control and 100% security search and freight guarding of the passengers' possessions, and the personnel's duties to perform such jobs are be! coming more crucial. On the other hand, Airport security check has bee n gradually developing since the 1960's, when hijacking began to take place. Although the airports have been providing more safe and comfortable services to their customers, terrorism is still happening today. When Ground security activities is minute, the users feel displeasure and discomfort, yet considering solely their convenience can brings problems in achieving safety. Since the 9.11 terror in 2001, the idea of improving and strengthening airport security was reinforced and a considerable amount of estate is being spent today for invention and application of new technology. Various nations, including the United States, have been improving their systems of security through public services; public police department is actively carrying out their duties in airports as well. In San Francisco International Airport, private police department is in charge of collection of data, national events, VIP protection, law enforcement, cooperation within facilities, daily-based patrol and traffic control. Under guidance and supervision of national organizations, such as TSA, general police department interprets X-Rays, operates metal detectors, checks passports or IDs and observes reactions to explosives. Under these circumstances, studies about advancement of cooperation and duties of general police department and private police department necessitated: especially about private police department and their training for searching equipments, decrease in number of turn over rate, invention of technology and prior settlement in estate for security. The privacy of the public, who make up the major population of airport passengers, must also be minimized. In the following research, the activities of police departments in San Francisco International Airport will be analyzed in order to understand recent actions of the United States on airport security.

Factors for Delayed Diagnosis of Acute Appendicitis in Children (소아 급성 충수돌기염 진단에 지연을 일으키는 요인에 관한 연구)

  • Han, Myung-Ki;Kim, Kyoung-Soo;Park, Yu-In;Kim, Jeong-Ho;Lee, Jung-Joo;Kim, Bong-Seong;Kang, Hye-Young
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.5 no.2
    • /
    • pp.158-165
    • /
    • 2002
  • Purpose: We designed this retrospective study to establish the incidence of diagnosic delay in children diagnosed with acute appendicitis and to identify associated factors with delayed diagnosis and its impact on the clinical course. Methods: All cases of children under 15 years of age who underwent appendectomy from 1996 to 2001 at Gangneung Asan Hospital were reviewed. We reviewed signs and symptoms, type of health professional first contacted, the advice given by the health professional and a history of appendicitis in first degree relatives. Diagnostic period is the time elapsed between first complaints and definitive diagnosis. Delay was defined as diagnostic period exceeded the 48 hours. Postoperative course and complications were also reviewed. Results: Incidence of diagnostic delay differed by whether diarrhea and fecalith on X-ray were present. Also children whose parents were advised to observe them at home were more likely to have a diagnostic delay. In almost half of the cases in delayed group, initial diagnosis was not acute appendicitis but gastroenteritis. The perforation rate in non-delayed group was 22%, whereas 87% in delayed group. The delayed group showed a higher number of postoperative complication and a longer hospitalization period. Conclusions: Diarrhea with abdominal pain and fever in children should not be dismissed as gastroenteritis, respiratory infections or other common disorders. Our study suggests that physicians have a responsibility to prevent diagnostic delay and resultant perforation of acute appendicitis in children by having a high index of suspicion about acute appendicitis.

  • PDF

Manufacturing Techniques of a Backje Gilt-Bronze Cap from Bujang-ri Site in Seosan (서산 부장리 백제 금동관모의 제작기법 연구)

  • Chung, Kwang Yong;Lee, Su Hee;Kim, Gyongtaek
    • Korean Journal of Heritage: History & Science
    • /
    • v.39
    • /
    • pp.243-280
    • /
    • 2006
  • At the Bujang-ri Site, Seosan, South Chungcheong Province, around 220 archaeological features, including semi-subterranean houses and pits of Bronze Age and semi-subterranean houses, pits, and burials of Baekje period had been identified and investigated. In Particular, mound burials No. 5 of 13 of Baekje mound burials yielding a gilt-bronze cap along with other valuable artifacts drew international scholarly attention. The gilt-bronze cap from the mound burial No. 5 is a significant archaeological data not only in the study of Baekje archaeology but also in the study of international affairs and exchange at that time. At the time of exposure, the gilt-bronze cap was already broken into a number of pieces and seriously damaged by corrosion, and hardening and urethane foam were necessary in the process of collecting its pieces. Ahead of main conservational treatments on cap, X-ray photograph and CT(computerizes tomography) were taken in order to examine interior structure of the cap and to decide appropriate treatments. In the five layers identified in the profile of cap, a textile layer was set between a metal and a layerof bark of paper birch for avoiding direct contact of the metal and the bark of paper birch. Analyses were executed for examining textile layer and a layer of fibroid material. According to microscopic analysis, while the textile layer consisted of the simplest plain fabric with one fold among three kinds of textile structures, the layer of fibroid material was mixed with two or three kinds of fibers. A comparative analysis with standard sample using FT-IR (Fourier Transform Infrared Spectroscopy) announced that both textiles and fabrics were hemp. Analysis of kind of the paper birch resulted in barks of paper birch with 15 fold. A metallographic microscope, SEM, and WDS were used for the analysis of microscopic structures of plated metal pieces. While amalgam plating was treated as a plating method, the thickness of the plated layer, a barometer of plating technique, was ranged from $1.72{\mu}m$ to $8.67{\mu}m$. The degree of purity of gold (Au) used in plating was 98% in average, and less than 1% of silver (Ag) was included.

Retrospective Analysis of Clinical Patterns and Antibiotic Utilization in Pediatric Patients Hospitalized with Respiratory Syncytial Virus Pneumonia at a Recently Established General Hospital (신생 대학병원에서 호흡기세포융합바이러스 폐렴으로 입원한 건강한 소아청소년환자에서의 임상 양상 및 항생제 사용에 대한 후향적 분석)

  • Hyejin So;Kyung Min Kim;Eun Young Cho
    • Pediatric Infection and Vaccine
    • /
    • v.31 no.1
    • /
    • pp.75-82
    • /
    • 2024
  • Purpose: As the coronavirus disease 2019 (COVID-19) pandemic ended, the number of patients with respiratory syncytial virus (RSV) pneumonia increased during the spring/summer of 2022. This study aimed to analyze the clinical features and antibiotic usage of children hospitalized for RSV pneumonia in a recently established general hospital in Sejong city. Methods: In this retrospective review, we included inpatients of the Pediatric Department of Chungnam National University Sejong Hospital diagnosed with RSV pneumonia between March 2022 and April 2023. Patients were divided into 2 groups: with and without antibiotic treatment. Demographic data, initial presentations, and clinical courses were reviewed. Results: A total of 116 patients with RSV pneumonia were hospitalized during this period, of which 102 were analyzed, excluding 14 with underlying diseases or who did not fall within the definition of pneumonia. The median age was 17 months. Diagnoses of bacterial infections (acute otitis media and sinusitis) were documented in 9.8% of cases. Intravenous (IV) antibiotics were administered in 46% of cases. The group receiving IV antibiotics showed higher inflammatory levels (C-reactive protein; CRP), more infiltration on initial chest X-rays, and longer fever duration. There was no difference in the length of hospitalization between the groups with and without IV antibiotics. Conclusions: This study showed a tendency for the attending physician to prescribe IV antibiotics to patients with longer fever duration, pulmonary infiltrations on the initial chest X-ray, and higher CRP levels. However, given the high rate of IV antibiotic usage compared to previous studies, care should be taken in antibiotic use.

A Study on the Radioprotection Effect of Selenium and Arginine Mixtures for Reducing Radiation Damage to Police SOU (경찰특공대 요원의 방사선손상 감소를 위한 셀레늄과 아르기닌 혼합물의 방호효과 연구)

  • Geun-Woo Jeong;Hae-Suk Kim;Jae-Hyeong Park;Sung-Hyun Joo;Jae-Gyeong Choi;Se-Im Cheon;Byung-In Min
    • Journal of the Korean Society of Radiology
    • /
    • v.18 no.2
    • /
    • pp.119-125
    • /
    • 2024
  • The purpose of this study is to examine the radioprotection effect of mixtures of selenium and arginine for development of radioprotection agents that can minimize radiation damage to police special operation unit in the event of radioactive terrorism. In this study 72 male rats were classified into 4 groups: normal group(NC Group), selenium and arginine mixtures administration group(SeAr Group), radiation exposure group(IR Group), and selenium and arginine mixture administration group followed by radiation exposure(SeAr+IR Group). The 7Gy of X-ray was irradiated to whole body of SD rats. And selenium and arginine were dministered orally at 3mg/kg and 150mg/kg once a day for 14 days. And then hematological and histological analyzes were performed on days 1, 7, and 21 after radiation exposure. In hemotological analysis, significant radioprotection wes observed in lymphocytes(p<0.05) on day 1, platelet(p<0.01) on day 7, red blood cell(p<0.01) on day 21 of radiation exposure in SeAr+IR group compared to IR group. In histological analysis, it was observed that the border of small crypt cells in the small intestine was less collapsed and the length of small crypts was relatively recovered on day 7 and showed that the number of cells and cell wall thickness were better in the prostate on day 21 in SeAr+IR group compared to IR group. Therefore, it is judged that selenium and arginine mixtures have radioprotection effect on blood and tissues due to radiation exposure. it will be helpful for research on radioprotection agents to reduce radiation damage to police special operation unit.