• Title/Summary/Keyword: ratio value

Search Result 8,632, Processing Time 0.038 seconds

The Value Relevance of Advertising Activity based on R&D Intensity and Export Ratio (매출액영업이익률, 매출액성장률, 부채비율 및 기업규모를 고려하여 살펴본 광고선전활동이 기업가치에 미치는 영향 : 한국 제조업 기업을 대상으로 한 연구개발집약도 및 수출비중의 조절효과 분석)

  • Kim, Jinsu;Kwon, Gee Jung
    • International Area Studies Review
    • /
    • v.14 no.3
    • /
    • pp.312-338
    • /
    • 2010
  • This paper investigates the value relevance of advertising activity over the period from 2001 to 2009 in the listed Korean stock markets(KOSPI and KOSDAQ). In addition, this paper divide all sample firm into several subsample, based on R&D intensity and export ratio in total sales. The empirical result of this paper shows following two evidence; First, advertising intensity, which proxies for advertising activity, is significantly related to firm value at the 1% level of significance. Second, advertising activity of high R&D intensity and high export ratio sample firms has more significant value relevance than for firms with low R&D intensity and low export ratio. The empirical results suggest that moderation effect of R&D intensity and export ratio are very important factor in determining the value relevance of advertising activity.

The Effects of the Annealing Temperature and Environments on Room Temperature Wear Behavior of Plasma-Sprayed Partially Stabilized Zirconia Coatings (플라즈마 용사된 부분안정화 지르코니아 코팅의 상온 마모거동에 미치는 열처리온도 및 분위기의 영향)

  • 김장엽;임대순
    • Journal of the Korean Ceramic Society
    • /
    • v.31 no.10
    • /
    • pp.1176-1180
    • /
    • 1994
  • The sliding wear behavior of the plasma-sprayed zirconia containing 3 mol% yttria was investigated after the annealing at room temperature to 80$0^{\circ}C$ in various concentrations of humid atmosphere as laboratory, humid, dry argon atmosphere. Both of the friction coefficient and the wear loss increased with increasing temperature up to 80$0^{\circ}C$. Surface morphology of the worn samples changed with annealing temperature. The change of monoclinic/tetragonal (m/t) x-ray peak intensity ratio effected the wear behavior. The m/t ratio had maximum value at 20$0^{\circ}C$ and decreased with increased temperature in laboratory and humid atmosphere. In argon atmosphere the m/t ratio had no maximum value and decreased with increasing temperature. At all the annealing temperature humid atmosphere had more the m/t ratio value than any other atmosphere. The change of toughness was showed the inversed result of m/t ratio change. The results indicated that the resudial stress which was induced by the different amount of phase transformation takes a detrimental role in wear behavior.

  • PDF

Consideration of Exergy and Exergy Ratio on T-s Chart of Water (물의 T-s 선도 상에서 엑서지 및 엑서지율의 고찰)

  • Kim, Deok-Jin;Kim, Duck-Bong
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.827-832
    • /
    • 2009
  • Exergy is the amount of reversible work obtainable when some matter is brought to a state of thermodynamic equilibrium with ambient. This exergy is availability or useful work induced from carnot cycle, and this can calculate the irreversible loss work which occurs within any thermal or power cycle. The exergy ratio is the value of exergy divided by enthalpy of ambient reference, where the quality of energy or enthalpy in substances is evaluated by exergy ratio. Exergy is very important in optimal design method of thermal system or each component, and the value of exergy at given state is calculated by equation. Here, designer can easily understand and find the value of enthalpy because enthalpy is graphically drawn in chart, however exergy did not. In this paper, exergy and exergy ratio of air were drawn on temperature-entropy chart, and we wish to this chart is a help to design, analysis and education.

  • PDF

A Study on Method for Screening of Hypercalciuria in Children (소아에서 소변 Na/K 비를 통한 칼슘 배설량 예측)

  • Ko Han Seong;Choi Jeong Hoon;Choi Byoung Min;Yoo Kee Hwan;Hong Young Sook;Lee Joo Won;Kim Soon Kyum
    • Childhood Kidney Diseases
    • /
    • v.4 no.1
    • /
    • pp.11-16
    • /
    • 2000
  • Purpose. Urinary calcium excretion using a 24-hr urine colledtion has been used for the diagnosis of hypercalciuria up to now. But It takes a lot of time and costs much. We have investigated on a more simple method for screening of hypercalciuria in children. Methods: We had retrospectively analyzed sodium, potassium, calcium and creatinine in spot urine of eighty-four patients with urinary symptoms from May 1998 to July 1998 in Korea university Guro hospital and compared the urinary Ca/Cr ratio with the Nin ratio. Using a urinary Nan ratio >2.68 as a cutoff value in predicting the occurrence of hypercalciuria, we measured its sensitivity, specificity, positive predictive value and the negative predictive value. Results: A direct relationship was found between urinary Na/K and Ca/Cr ratio (r=0.496, P<0.001, Ca/Cr : Na/K x 0.0167+0.061). Using a urinary Na/K ratio >2.68 as a cutoff value in predicting the occurrence of hypercalciuria, its sensitivity was found to be $100\%$ and its specificity $54.5\%$. The positive predictive value was $37.5\%$ and the negative predictive value $100\%$. Conclusions : Spot urine Na/K ratio is a valuable test for the screening of hypercalciuria in children.

  • PDF

A Study on Application Methods of the Transfer of Development Rights - Focused on Residential Areas of Gwangju - (개발권양도제 적용방안에 관한 연구 - 광주광역시 주거지를 중심으로 -)

  • Jeong, Woo-Gon
    • Journal of the Korean housing association
    • /
    • v.23 no.5
    • /
    • pp.61-73
    • /
    • 2012
  • This study applied the value of floor-area-ratio standard calculation method to case areas and analyzed them to overcome the limits of previous studies in calculation methods for area standards and land price (value) standard development rights. The results are presented as follows: First, criteria to select sending areas and receiving areas are needed. Second, calculation methods based on the value of floor-area-ratio standard can be widely used as standardized criteria in various areas. Third, for the connection of sending areas with receiving areas, the connections of 1:1, n:1, 1:n, and n:n are available and the location of possible dealing areas should be considered. Also, the choice of connecting unions that meet the purpose of TDR presented by local governments is available. Fourth, for Gwangju, as receiving areas downtown provide higher profits than previous renewal projects, the application of TDR is available. Application methods to overcome problems are presented as follows: First, criteria to select sending and receiving areas should be prepared and implemented in an order of priority. Second, in calculating development rights, methods based on the value of floor-area-ratio standard should be used. Third, the standards and principles of sending and receiving areas should be designated and possible dealing areas should not be limited.

A Study on Evaluation of Crack Opening Point in Al 2024-T3 Material (Al 2024-T3재의 Crack Opening Point의 평가에 관한 연구)

  • Choi, Byung-Ki;Jang, Kyeung-Cheun
    • Journal of the Korean Society of Safety
    • /
    • v.19 no.2
    • /
    • pp.16-20
    • /
    • 2004
  • This paper aims to analyze fatigue fracture mechnisms with high strength aluminum alloys, which are widely used in vehicles or airplanes to prevent accidents. Usefulness of the crack opening point was proposed by using an effective stress intensity facor when evaluating the fatigue crack propagaion rate. Therefore an exact crack opening ratio can be measured for a more exact fatigue crack propagation rate. It is found that the fatigue crack propagation rate was valid within the range of experimentation as an effective stress intensity factor. Summarizing the results are as follows in this paper ; (1) It is found that the value of the crack opening ratio is constant at the rear of the specimen, U'=0.25 at the crack mouth and U'=0.45 at the crack tip, respectively regardless of the stress ratio. (2) The crack opening ratio is different according to measurement locations. The crack opening ratio value was measured at the crack mouth by a clip gage or measured behind the specimen by a strain gage. It is found that the crack opening ratio value is more accurate that any other measuring test for evaluating the crack propagation ratio test by effective stress intensity factor.

A Study on Evaluation of Crack Opening Point in High Strength Aluminum Alloy(I) (고강도 알미늄 합금재에 있어서 크랙열림점 평가에 관한 연구(I))

  • 최병기
    • Journal of the korean Society of Automotive Engineers
    • /
    • v.15 no.1
    • /
    • pp.100-106
    • /
    • 1993
  • This paper aims to synthesize the research on fatigue fracture mechanisms of high strength aluminum alloys which are widely used in motorcars or airplanes to prevent accidents. To measure the data of crack opening ratio, the same materials and method are used for evaluating the fatigue crack propagation rate as an effective stress intensity factor. But, many researchers have brought different results. An exact crack opening ratio was, therefore, proposed for getting a more accurate fatigue crack propagation rate. The main conclusions obtained are as follows. (1) As a result of the fatigue test, the value of the crack opening ratio is the same regardless of the stress ratio. (2) The value of crack opening ratio is different according to the measuring point. After measuring the crack propagation rate by using an effective stress intensity factor, the crack opening ratio value measured at the crack mouth by a clip gage, or measured rear of the specimen by a strain gage is more accurate than that by any other measuring test.

  • PDF

A Study of Cardiothoracic Ratio in Insurance Medicine (심흉비(心胸比)의 보험의학적(保險醫學的) 고찰(考察))

  • Im, Young-Hoon
    • The Journal of the Korean life insurance medical association
    • /
    • v.2 no.1
    • /
    • pp.152-181
    • /
    • 1985
  • A statistical analysis on the cardiothoracic ratio in insurance medicine was carried out for 5,200 insured persons who were medically examined including photofluorography of the chest at the Honam medical department, Dong Bang life insurance Company, Ltd from November, 1979 to August, 1984. The results were as follows: 1. The mean value of the cardiothoracic ratio in all of the insured was $44.2{\pm}4.3%$. The mean value of the cardiothoracic ratio was $43.1{\pm}4.1%$ in all males and $45.2{\pm}4.2%$ in all females, and the difference of the values between males and females showed statistical significance(P<0.001). In each age group, the mean value of the cardiothoracic ratios of female was higher than that of male without exception and the difference of the values between males and females showed statistical significance(P<0.001). The mean value of the cardiothoracic ratio showed gradual increase with age from the second to sixth decade in male(P<0.05 or 0.001 after fourth decade) and from the second to seventh decade in female(P<0.05 or 0.001 from the second to sixth decade). 2. Correlation between both sexes and among age groups relating to the cardiothoracic ratios of the insureds seen to be a physiological phenomenon of the cardiac size and should be considered on the rating of the cardiothoracic ratio. Based on the correlation above mentioned and an author's assumption that the incidence of normal and abnormal cardiothoracic ratios in each age group would show the same rate in male and female, author prepared a modified rating table from the existing table; in male group the existing rating table is used and in female group the ratings of 0, 30-50, 50-100 and 100-D are to calculate by the cardiothoracic ratio of 51%or under, 52-56%, 57-61% and 62% or over respectively in the age group below 39, by the cardiothoracic ratio of 52% or under, 53-57%, 58%-62% and 63% or over respectively in the age group of 40-49, by the cardiothoracic ratio of 53% or under, 54-58%, 59-63% and 64% or over respectively in the age group over 60. 3. The relative frequency distribution polygons of the cardiothoracic ratio of both sexes drawn in a pair on one coordinate plane revealed lying in juxtaposition each other horizontally and showed the shifting of females polygon to male's one toward the direction of greater value of the cardiothoracic ratio at a short distance which increased gradually with age. 4. The minimum cardiothoracic ratio was 31.2% and the maximum cardiothoracic ratio was 63.6% in all of the insured. 5. In each age group, no significant sex difference was found in the relative frequency distribution of ratings by the cardiothoracic ratios of 5,200 insureds by using the rating table modified by author, while significant sex difference was found by using the existing rating table.

  • PDF

A Study on the Aging Change of Exit Light by Measuring the Ratio of Luminance (휘도비 측정을 통한 유도등의 경년변화 연구)

  • Jung, Jong-Jin
    • Fire Science and Engineering
    • /
    • v.33 no.6
    • /
    • pp.181-185
    • /
    • 2019
  • In this study, Exit light installed in offices, malls, hospitals, and factories were analyzed to analyze the luminance performance of CCFL and LED light sources. In addition, fire protection products with electrical characteristics such as Exit light may change their performance due to ambient temperature, humidity, and dust. So it was extracted by installation place and analyzed its characteristics. As a result of the experiment, Exit light for CCFL type showed the value of 'ratio of luminance 2' for large, medium and small. Considering that the reference value was 'lower than 9', the value was very good and it can be seen that there is almost no change in ratio of luminance due to aging. The Exit light for LED type showed a value of 'ratio of luminance 5', which means that the light on the display surface is not uniform. In addition, there was almost no change in ratio of luminance due to ageing, but the ratio of luminance was larger than Exit light for LED type. This is an unsatisfactory result from a visual point of view. To improve this, it is necessary to disperse the light of LED light source and strengthen the regulation on ratio of luminance.

Maximal Oxygen Debt, Lactate and Excess Lactate in Men with Low Hematocrit Ratio (헤마토크?????? 비율이 낮은 사람에 있어서 최대 산소 부채와 과잉젖산 사이의 관계)

  • Kim, Dai-Sung;Nam, Kee-Yong
    • The Korean Journal of Physiology
    • /
    • v.2 no.2
    • /
    • pp.53-61
    • /
    • 1968
  • Maximal oxygen debt, lactate and excess lactate were measured in 13 men with low hematocrit ratio before and after maximal exercise. Maximal exercise run was performed on a treadmill and the duration of run was 2 minutes 45 seconds in each subject. Hematocrit ratio ranged between 35 and 47%, the mean being 39.8%. The following results were obtained. 1. Maximal oxygen debt expressed on basis of body weight increased as the hematocrit ratio decreased. The correlation coefficient between the two was r= -0.770. 2. The time necessary for decreasing to 50% of total maximal $O_2$ debt(half time) became longer as the hematocrit ratio decreased. In normal men the half time was about 4 minutes and at the longest it was 12 minutes in men with the lowest hematocrit ratio. 3. The lactate concentration reached its peak value after 3 minutes of recovery. Thereafter, the time course of decrease in lactate concentration coincided roughly with that of respiratory oxygen debt curve. To reach to the resting level, however, it took longer time than that of respiratory oxygen debt. 4. Resting concentrations of lactate was 1.28 mM/l, pyruvate 0.13 mM/l and L/P ratio was 9.8. Peak value of ${\Delta}L$ after exercise reached to the value of 10.4 mM/l and ${\Delta}L/P$ reached 26.0. Peak excess lactate after exercise was 6.34 mM/l. 5. The part of oxygen debt accounted for by the oxygen equivalent of excess lactate was only 38.4%. A better relationship between lactate and oxygen debt was observed and the part of oxygen debt accounted for by the oxygen equivalent of lactate was 63.3%. 6. Peak value of lactate after maximal exercise increased as the hematocrit ratio decreased. 7. Respiratory oxygen debt of 100 ml/kg was accounted for by lactate more than 60% and only 30% was by excess lactate. 8. Excess lactate was not a good index of respiratory oxygen debt.

  • PDF