• Title/Summary/Keyword: ratio transformer

Search Result 397, Processing Time 0.024 seconds

Fabrication and Characteristics of Piezoelectric transformer using PMN-PZT (PMN-PZT 세라믹을 사용한 압전트랜스포머 제작과 특성)

  • 류주현;손은영;류규현;윤현상;정희승
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1997.11a
    • /
    • pp.13-20
    • /
    • 1997
  • In this paper, the voltage step-up ratio, efficiency and input impedance of the PMN-PZT cert- mic transformer(PT) were investigated for the variation of resonant frequency according to lead resistance. The output voltage and voltage step-up ratio are increased with the the increase of load resistance. The efficiency of PT showed the maxinum value of 91% at R$_{L}$ of 500k$\Omega$X>

  • PDF

Electric Power Characteristics of a SFCL based on Turn-ratio of 3-Phase Transformer (3상 변압기의 권수비에 따른 초전도 한류기의 전력특성)

  • Jeong, In-Sung;Choi, Hyo-Sang;Jung, Byung-Ik
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.3
    • /
    • pp.414-417
    • /
    • 2014
  • At present, the demand for electric power increases, the electric power system is complicated. The size of the line-to-ground fault and the line-to-line fault occurred with complication of electric power system continue to increase, therefore several issues are raised. To address these issues effectively, the superconducting fault current limiter (SFCL) has been proposed, this study is ongoing. In this paper, we applied the SFCL in three-phase transformer and comparative analysis of the electric power burden to the SFCL. The superconductor is combined to the third winding of transformers in connection structure. In case of a third line-to-line fault, we did comparative analysis of the electric power burden to the SFCL based on the turn ratio of transformer third winding. In this case, we could confirm as the third turn ratio increased, electric power impressed to the superconducting element increased.

A Study on the Harmonics Effect of Ratio Differential Relay for Transformer Protection (변압기 보호용 비율차동계전기의 고조파 영향에 관한 연구)

  • Kim, Kyung-Chul;Hwang, Young-Rok;Kho, Hun;Jung, Dong-Won;Chung, Hae-Sung;Lee, Dong-Wook;Jeong, Chae-Ho;Lee, Jae-Yoon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.6
    • /
    • pp.99-105
    • /
    • 2014
  • Power transformers are applied throughout the power system to connect systems of different voltage to one another. Since a ratio differential relay offers high sensitivity in detection of internal faults in power transformers, it is widely used in the main protection system. The use of nonlinear devices such as rectifiers and other devices utilizing solid state switching have been increased in industry during recent years. For nonlinear loads, the load current is not proportional to the instantaneous voltage. This situation creates harmonic distortion on the system. The harmonic could differential relay misoperation if not recognized. This paper aims at analyzing and probing into the influences of harmonics on a ratio differential relay for power transformer protection.

A Study on the Mechanism with the Electrode Ratio of Driving and Generation Part of a Disk-Type Piezoelectric Transformer (디스크형 압전변압기의 전극 면적비에 따른 구동 메카니즘에 관한 연구)

  • Lee, Jong-Pil;Chae, Hong-In;Jin, Woong-Hong
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.5
    • /
    • pp.17-22
    • /
    • 2005
  • In this study, a disk-type piezoelectric transformer was fabricated. Its diameter was 50[mm] and thickness was 4.5[mm]. The driving and generating electrode with their gap of 1[mm] were fabricated on the top surface. But the common electrode was fabricated on the whole bottom surface. The electrode surface ratio of driving and generating part on the top surface was the range of 1.4:1 to 3:1. We investigated the electrical characteristics with the variation of its thickness and the electrode surface ratio of driving and generating part in the range of load resistance of 100${[\Omega]}\~70{[k\Omega]}$.. Form the experimental results, their influence on the set-up voltage ratio were investigated quantitively and qualitatively.

The Development of an Operating System for Load-following Real-time Transformer Loss Minimization and Economic Analyses on its' Test Operation (부하 추종형 실시간 변압기 손실감소운전시스템 개발과 시범운영 경제성 분석)

  • Lee, Ok-Bae;Ahn, Jae-Kyoung
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.6
    • /
    • pp.797-803
    • /
    • 2012
  • In this paper, for minimizing the real-time operating load losses of the power transformer, a SCADA optimum operating system was developed, and the economic analyses on the test operation were performed. Transformer loss DB which reflects the economic integration operation criteria was constructed by referring the transformer manufacturer's loss data(iron loss, copper loss). Based on the loss DB, each substation transformer real-time loss was calculated according to the size of the transformer loads, and if integration or separation transformer operating conditions minimizing the loss are met, then a window pops-up and the dispatcher performs the substation equipments operation according to the procedure provided by this system. With the existing SCADA main program, the relation database of the substation facilities and integration/separation operation algorithm were developed and applied to Auto MTR Processor and pconn Processor Task module. Seven stations test data for seven months were analyzed for the economic analyses, and the results showed that Cost-Benefit ratio was 2.64, and IRR(Internal Rate of Return), 36%, which asserted the economic justification of the proposed system.

Design and Simulation Technologies of Flat Transformer with High Power Current (대전류 출력형 Flat Transformer 설계 및 해석 기술)

  • Han, Se-Won;Cho, Han-Goo;Woo, Bung-Chul
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.05c
    • /
    • pp.15-17
    • /
    • 2002
  • Leakage inductance and temperature rise are two of the more impotent problems facing the magnetic core technology of today's high frequency transformers. Excessive leakage inductance increases the stress on the switching transistors and limits the duty-cycle, and excessive temperature rise can lead the design limitation of high frequency transformer with high current. The flat transformer technology provides a very good solution to the problems of leakage inductance and thermal management for high frequency power. The critical magnetic components and windings are optimized and packaged within a completely assembled module. The turns ratio in a flat transformer is determined as the product of the number of elements or modules times the number of primary turns. The leakage inductance increase proportionately to the number of elements, but since it is reduced as the square of the turns, the net reduction can be very significant. The flat transformer modules use cores which have no gap. This eliminates fringing fluxes and stray flux outside of the core. The secondary windings are formed of flat metal and are bonded to the inside surface of the core. The secondary winding thus surrounds the primary winding, so nearly all of the flux is captured.

  • PDF

Study on designing of Flat Transformer and operating characteristics of Converter (Flat Transformer 코아의 설계와 컨버터 동작 특성)

  • Han, Se-Won;Cho, Han-Goo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.587-590
    • /
    • 2003
  • The first attention in designing a transformer for low temperature rise should be to reduce losses. Leakage inductance and temperature rise are two of the more impotent problems facing the magnetic core technology of today's high frequency transformers. Excessive leakage inductance increases the stress on the switching transistors and limits the duty-cycle, and excessive temperature rise can lead the design limitation of high frequency transformer with high current. The flat transformer technology provides a very good solution to the problems of leakage inductance and thermal management for high frequency power. The critical magnetic components and windings are optimized and packaged within a completely assembled module. The turns ratio in a flat transformer is determined as the product of the number of elements or modules times the number of primary turns. The leakage inductance increase proportionately to the number of elements, but since it is reduced as the square of the turns, the net reduction can be very significant. The flat transformer modules use cores which have no gap. This eliminates fringing fluxes and stray flux outside of the core. The secondary windings are formed of flat metal and are bonded to the inside surface of the core. The secondary winding thus surrounds the primary winding, so nearly all of the flux is captured.

  • PDF

Device and Piezoelectric Characteristics of Pb(Mn1/3Sb2/3) O3-PZT Ceramics for Piezoelectric Transformer

  • Sohn, Joon-Ho;Heo, Soo-Jeong;Sohn, Jeong-Ho;Lee, Joon-Hyung;Jung, Woo-Hwan;Kim, Dong-Bum;Cho, Sang-Hee
    • The Korean Journal of Ceramics
    • /
    • v.5 no.2
    • /
    • pp.171-177
    • /
    • 1999
  • In the $(Pb_{1-x}M_x)[(Mn_{1/3}Sb_{2/3})_{0.05}Zr_yTi_{0.95-y}]O_3$ system, where M=Ca and Sr, the piezoelectric properties were evaluated to examine the possibility of application to piezoelectric transformer. A Rosen-type piezoelectric transformer was formed, then the electrical properties of voltage step-up ratio, frequency characteristics etc. were analysed. The morphotropic phase boundary was determined to be y=0.475 in $Pb[(Mn_{1/3}Sb_{2/3})_{0.05}Zr_yTi_{0.95-y}]O_3$ system and the piezoelectric properties of this composition was kp=0.59, Qm=1600 and $\varepsilon_r$=1150. Moreover, when 1-2 mol% of Sr are substituted, enhanced piezoelectric properties of kp=0.61, Qm=1600 and $\varepsilon_r$=1400 were shown. The temperature rising (ΔT) of a piezoelectric transformer with $Pb[Mn_{1/3}Sb_{2/3})_{0.05}Zr_{0.475}Ti_{0.475})]O_3 $ composition was $10^{\circ}C$, and the voltage step-up ratio was 500 when the output voltage was 4000V, whereas the ΔT was below $3^{\circ}C$ and the resonant frequency variation ($\Delta f_r$) as a function of load resistance was below 5% when the output voltage was 2000 V. These characteristics are superior to the properties of materials, which were substituted by Ca or without substitution.

  • PDF

Uncertainty Analysis in Potential Transformer Calibration Using a High Voltage Capacitance Bridge

  • Jung, Jae-Kap;Lee, Sang-Hwa;Kang, Jeon-Hong;Kwon, Sung-Won;Kim, Myung-Soo
    • Journal of Electrical Engineering and Technology
    • /
    • v.2 no.3
    • /
    • pp.401-407
    • /
    • 2007
  • Precise absolute measurement of the errors in a potential transformer (PT) can be achieved using high voltage capacitance bridge (HVCB) and capacitive divider. The uncertainty in a PT measurement using the HVCB system was evaluated by considering the overall factors affecting during the calibration of a PT. The expanded uncertainties are found to be not more than $30{\times}10^{-6}$ for ratio and $30{\mu}rad$ for phase up to the primary voltage of $V_p=22kV$. For same PTs, the measured errors in KRISS (Korea Research Institute of Standards and Science) using our bridge are well coincide with those in NMIA (National Measurement Institute of Australia) and PTB (Physikalisch-Technische Bundesanstalt) within the corresponding uncertainties.

Resonance characteristics and electrical properties of PZT-piezoelectric transformer (PZT계 압전변압기의 공진특성과 전기적 성질)

  • 박순태;정수태;이종헌
    • Electrical & Electronic Materials
    • /
    • v.8 no.1
    • /
    • pp.27-34
    • /
    • 1995
  • The analysis of nonlinear equivalent circuit and the resonance characteristics of input current and output voltage were simulated, and their electrical properties are discussed in the transverse-type piezoelectric ceramic transformer. The nonlinear resonance characteristics of input current and output voltage showed by the thermal effect due to a higher driving current, the nonlinearity increased greatly as driving current increased. When load resistor was 100[M.ohm.], the nonlinear coefficient was -1.3. The nonlinear resonance curve of input current and output voltage for a variation of input voltage and load resistor agreed with the discussed theory. The output voltage increased nearly proportioned to input voltage when load resistors were below 50[M.ohm.], the voltage step-up ratio decreased when a load resistor was 100[M.ohm.] and their maximum value was 950.

  • PDF