• Title/Summary/Keyword: ratio transformer

Search Result 397, Processing Time 0.028 seconds

High Voltage SMPS Design based on Dual-Excitation Flyback Converter (이중 여자 플라이백 기반 고압 SMPS 설계)

  • Yang, Hee-Won;Kim, Seong-Ae;Park, Seong-Mi;Park, Sung-Jun
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.20 no.2
    • /
    • pp.115-124
    • /
    • 2017
  • This paper aims to develop an SMPS topology for handling a high range of input voltages based on a DC-DC flyback converter circuit. For this purpose, 2 capacitors of the same specifications were serially connected on the input terminal side, with a flyback converter of the same circuit configuration serially connected to each of them, so as to achieve high input voltage and an effect of dividing input voltage. The serially connected flyback converters have the transformer turn ratio of 1:1, so that each coil is used for the winding of a single transformer, which is a characteristic of doubly-fed configuration and enables the correction of input capacitor voltage imbalance. In addition, a pulse transformer was designed and fabricated in a way that can achieve the isolation and noise robustness of the PWM output signal of the PWM controller that applies gate voltage to individual flyback converter switches. PSIM simulation was carried out to verify such a structure and confirm its feasibility, and a 100W class stack was fabricated and used to verify the feasibility of the proposed high voltage SMPS topology.

Establishment of Evaluation System for 40,000 A Rogowski Coil (40,000 A 로고스키 코일 평가 시스템 구축)

  • Kim, Yoon-Hyoung;Han, Sang-Gil;Jung, Jae-Kap;Kang, Jeon-Hong;Lee, Sang-Hwa;Han, Sang-Ok
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.58 no.2
    • /
    • pp.202-206
    • /
    • 2009
  • Evaluation system for calibrating Rogowski coiI(RC) up to primary current of 40,000 A have been established. The system consists of 40,000 A AC high current source, current transformer(CT) comparator, standard CT, RC under test, voltage to current convertor(VCC), buffer and CT burden. An AC high current is applied to the primary windings of both the standard CT and the RC under test, and then the CT comparator measures the ratio error and the phase displacement by comparing the secondary current of the standard CT with output current of VCC. For testing of RC, we have evaluated two RCs under test of primary current ranges of 0 A ${\sim}$ 2,000 A and 0 A ${\sim}$ 40,000 A with the accuracy class of 1 %. The extended uncertainty is 0.02 % ${\sim}$ 0.23 % for ratio error and 0.29 min ${\sim}$ 1.93 min for phase displacement in the primary current ranges of 10 ${\sim}$ 40,000 A.

A Novel Multilevel Inverter Employing Series Connected Transformers (변압기 직렬 결합을 이용한 새로운 멀티 레벨 인버터)

  • 박성준;강필순;박노식;김철우
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.8 no.1
    • /
    • pp.9-16
    • /
    • 2003
  • This paper presents an novel multilevel inverter employing series connected transformers to reduce the harmonics of output voltage. The proposed inverter consists of several full-bridge modules and their corresponding transformers. Continuous output voltage levels can be generated from a suitable selection of turns ratio of transformer. And it appears an integral ratio to input DC source. Because of its series operation of transformers, output filter inductor is not required. The validity of the proposed system is verified through the experimental results using a 1.5 [kW] prototype, which can generate a 220 $[V_ac]$ output voltage from $[V_dc]$ input.

A Study on the Surface Corona Discharge in the Gas with different Mixing Ratio of Air to $SF_6$ ($SF_6$와 공기의 혼합기체중에서의 연면 코로나 방전)

  • 전춘생;조기선;우호환
    • 전기의세계
    • /
    • v.26 no.6
    • /
    • pp.78-85
    • /
    • 1977
  • This paper studies flashover voltage and surface corona loss of A.C and D.C in the mixed gas of air and SF$_{6}$ for solid insulators P.V.C, arcylic, glass and bakelite in two cases. In one case, those solids are covered with transformer oil and the other case, those solids are not covered with it. 1) The flashover voltage for each solids in SF$_{6}$ is more than three times compared with that in the air. The flashover voltage for P.V.C is the highest and then arcylic, glass, bakelite in a decreasing order. 2) The more the amount of SF$_{6}$ in the mixing ratio, the less corona loss. The P.V.C shows the least amount of corona loss and the bakelite the largest. 3) Compared with the corona loss of positive polarity and the negative polarity, the former has less corona loss than the latter. 4) The more the number of flashover discharge, the less insulation of each solids, but in case of bakelite, insulation almost vanishes after a couple of discharge. 5) When each insulator is covered with transformer oil, the flashover voltage generally increases and the corona loss decreases.eases.

  • PDF

New Modeling Method for an Electrodeless Fluorescent Lamp Using the Relation of Lamp Output Power and the Modeling Coefficients of the Lamp (무전극램프의 출력전력 변화에 따른 새로운 모델링 기법)

  • Lim, Byoung-Noh;Jang, Mog-Soon;Sin, Dong-Seok;Park, Chong-Yeun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.9
    • /
    • pp.1626-1631
    • /
    • 2007
  • This paper presents a new modeling method using lamp output power and the modeling coefficients of the lamp. The proposed method utilizes the lamp modeling coefficients such as equivalent impedance Z(p), coupling coefficient of the transformer k(p), turns ratio of the transformer n(p), and plasma resistance Rp(p) as a function of lamp output power. The equivalent impedance Z(p) was developed from the equivalent resistance Req(p) and equivalent inductance Leq(p) of the lamp. Simulation and experimental results of the proposed model are presented in order to validate the proposed method. The modeling method can use to design an impedance matching circuit for a Class-D inverter.

An Active Clamp Forward Converter with a Current Doubler Rectifier (Current Doubler 정류기를 이용한 능동클램프형 포워드 컨버터)

  • Eur, Sung-Jun;Choi, Jae-Ho;Ahn, Tae-Young
    • Proceedings of the KIEE Conference
    • /
    • 1997.07f
    • /
    • pp.2020-2022
    • /
    • 1997
  • An active clamp forward converter is proper for minimization and basically makes high efficiency of the system because of soft switching type. Especially, when applied to forward converter, it widens the control range of duty ratio and is suitable for high input voltage. In other hand, the current doubler has high utility efficiency of transformer and reduces output current ripple because it always transfers the power through the transformer and has two inductor with opposite slope. So, this paper explained the conduction mode of an active clamp forward converter with the current doubler rectifier.

  • PDF

개선된 자속구속형 전류제한기의 동작 특성 분석

  • Kim, Yong-Jin;Du, Ho-Ik;Kim, Min-Ju;Lee, Dong-Hyeok;Han, Byeong-Seong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.11a
    • /
    • pp.215-215
    • /
    • 2009
  • Improved flux-lock type superconducting fault current limiter(SFCL) is composed of a series transformer and superconducting unit of the YBCO coated conductor. The primary and secondary coils in the transformer were wound in series each other through an iron core and the YBCO coated conductor was connected with secondary coil in parallel. In this paper, we investigated the current limiting characteristics through initial line current after fault initiation. through the analysis, it was shown that the smaller initial line current is superior to current limiting characteristics and a point of view of power burden of the YBCO coated conductor.

  • PDF

A Study on Transformer Design of Multi-Level Converter (멀티레벨 컨버터의 변압기 설계에 대한 연구)

  • Kim, Chun-Sik;Kwon, Soon-Kurl;Lee, Hyun-Woo;Park, Sung-Woo;Chun, Jung-Ham
    • Proceedings of the KIEE Conference
    • /
    • 2003.04a
    • /
    • pp.303-305
    • /
    • 2003
  • This paper discusses single-phase AC-DC converter that driven by binary combination at different transformer winding ratio. It has a advantage that constructs a control system simply and obtain load current of good quality without filter circuit and free from noise or isolation for lower switching frequency. Also, this has merit that can do high power capacity. In this research, study on feedback circuit that consist for load stability of AC-DC multi-level converter.

  • PDF

Dielectric Characteristic Analysis of Thermally Aged Insulating Oil for Transformers (열적열화된 변압기용 절연유의 유전특성 분석)

  • Jung, J.W.;Lee, B.S.;Song, I.K.;Park, J.S.;Kwak, H.R.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07c
    • /
    • pp.1594-1596
    • /
    • 2001
  • The purpose of this paper is to provide the fundamental data which can be used for the design of pole transformers. For the purpose, electrical characteristics of aged mineral oil and silicone oil were analyzed by comparing with the results of virgin ones. For the experiment, an oil bath which can keep constant temperature was constructed to thermally deteriorate the specimens. And transformer materials were put together in the bath according to the their ratio in weight in the pole transformer. And the parameters such as relative permittivety, tan$\delta$ and specific resistance were measured. As a results, the permittivity of silicone oil was higher than that of mineral oil, and its decreasing rate with temperature was also higher. In addition, it was found that tan$\delta$ and specific resistance of virgin and aged oil began to differ at similar temperature.

  • PDF

Compensation for the Secondary Current of an Air-gapped Current Transformer (공극 변류기의 2차 전류 보상)

  • Kang, Yong-Cheol;Zheng, Tai-Ying;Jang, Sung-Il;Kim, Yong-Gyun;Park, Ji-Youn
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.2
    • /
    • pp.149-154
    • /
    • 2008
  • An air-gapped current transformer(CT) has been used to reduce a remanent flux in the core, particularly in the case of auto-reclosure. However, it causes larger transient, ratio and phase errors than the iron-cored CT because of the small magnetizing inductance. This paper proposes a compensation algorithm for the secondary current of the air-gapped CT during the fault conditions including auto-reclosure as well as in the steady-state. The core flux is calculated from the measured secondary current of the CT and inserted into the hysteresis loop to estimate the exciting current. Finally, the correct current is estimated by adding the measured secondary current to the estimated exciting current. Various test results clearly indicate that the proposed compensating algorithm can improve the accuracy of the air-gapped CT significantly and reduce the required core cross-section of the air-gapped CT significantly.