• Title/Summary/Keyword: ratio transformer

Search Result 397, Processing Time 0.027 seconds

Development of The Standard Current Transformer with Wide Ratio Error and Its Application (광범위 비오차 표준 전류변성기의 개발 및 그 응용)

  • Kwon, Sung-Won;Jung, Jae-Kap;Lee, Sang-Hwa;Kim, Mun-Seog;Kim, Myung-Soo
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.55 no.6
    • /
    • pp.302-307
    • /
    • 2006
  • Standard current transformer(CT) with the nominal ratio errors in the range of - 10 % to + 10 % has been developed. Linearity of the CT ratio error measuring system (CT comparator) has been tested by using wide ratio error standard current transformer(WRE CT). The developed WRE CT can be used to evaluate the linearity of the CT comparator by comparing both the theoretical values and experimental values of the WRE CT. The developed method has been successfully applied for calibration and correction in the CT comparator belonging to industry.

Research on a New 12-Pulse Step-Up and Step-Down Aviation Auto-Transformer Rectifier

  • Jiang, Fan;Ge, Hong-juan;Dong, Xiao-xu;Zhang, Lu
    • Journal of Power Electronics
    • /
    • v.18 no.1
    • /
    • pp.266-276
    • /
    • 2018
  • This paper presents a new step-up and step-down multi-pulse auto-transformer rectifier unit (ATRU) topology. This structure can achieve a wide range of output voltages, which solves the problem of auto-transformer output voltage being difficult to regulate. Adding middle taps to the primary winding and reasonably setting the number of auto-transformer windings, constituted two groups of three-phase output voltages with a $30^{\circ}$ phase difference. Multi-pulse output DC voltage is obtained after a three-phase output voltage across two rectifier bridges and inter-phase reactor. Thus, the output DC voltage is related to the number and configuration of the auto-transformer winding. In this paper, the relationship between the voltage ratio of the auto-transformer and the ratio of winding, input current and auto-transformer kilovoltampere rating are deduced and validated by simulations. On this basis, the output voltage range is optimized. An experiment on two different voltage ratio principle prototypes was carried out to verify the correctness of the analysis design.

Three-Winning Transformer Protection Based on Flux Linkage Ratio (쇄교자속비를 이용한 3권선 변압기 보호)

  • 강용철;이병은;김은숙;원성호
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.53 no.7
    • /
    • pp.375-381
    • /
    • 2004
  • This paper describes a three-winding transformer protective relaying algorithm based on the ratio of increments of flux linkages (RIFL). To minimize the approximation errors, the algorithm uses integration approximation. The RIFL of the two windings is equal to the turns ratio for all operating conditions except for an internal fault. For a single-phase and three-phase transformer containing the wye-connected windings, the increments of flux linkages (IFL) are calculated. For a three-phase transformer containing the delta-connected windings, the difference of IFL between the two phases are calculated to use the line currents, because the winding currents are practically unavailable. Their ratios are compared with the turns ratio. The comparative study between the proposed and differential approximation methods was conducted. The test results show that the algorithm can reduce the errors resulting from the conventional methods.

Evaluation Technique for Ratio Error of Current Transformer Comparator (전류변성기 비교기의 비오차 평가 기술)

  • Kim, Yoon-Hyoung;Han, Sang-Gil;Jung, Jae-Kap;Han, Sang-Ok
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.57 no.3
    • /
    • pp.291-295
    • /
    • 2008
  • We have developed an evaluation technique for ratio errors of current transformer (CT) comparator by using the precise standard capacitors. By applying this technique for equivalent circuit of CT comparator evaluation system, we can obtain the calculated and measured ratio errors in the CT comparator. Thus we can evaluate ratio errors of CT comparator by comparing the calculated and measured ratio errors. Because this method requires only the standard capacitors, it is simple and easy method to reliability and accuracy maintenance of CT comparator. The method was applied to CT comparator under test with the ratio error ranges of $0{\sim}{\pm}10%$. The ratio error of the CT comparator under test theoretically obtained in this method are consistent with that measured for same CT comparator under test by using wide ratio error CT within an estimated expanded uncertainty (k = 2) in the overall ratio error ranges.

Three Dimensional Finite Element Analysis for Piezoelectric Transformer

  • Joo, Hyun-Woo;Lee, Chang-Hwan;Jung, Hyun-Kyo
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.11B no.3
    • /
    • pp.98-103
    • /
    • 2001
  • This paper presents the numerical analysis of piezoelectric devices using three-dimensional finite element analysis. The characteristic of piezoelectric transducer, such as mechanical displacement and electrical are analyzed and the validity is confirmed by experiments Applying the finite element routine to a piezoelectric transformer, the resonance features electrical impedance. the ratio of step-up voltage and vibration mode of piezoelectric transformer are calculated numerically By using three-dimensional finite element method effects of width variation to resonance features, electrical input impedance and the voltage step-up ratio for a piezoelectric transformer, can be considered in design procedure.

Evaluation Technique of Burden for Current Transformer using Current Transformer Comparator and Precise Shunt Resistor (전류변성기 비교기와 정밀션트저항을 이용한 전류변성기용 부담의 평가기술)

  • Lee, Sang-Hwa;Kang, Jeon-Hong;Kim, Myung-Soo;Jung, Jae-Kap
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.55 no.5
    • /
    • pp.250-256
    • /
    • 2006
  • Both ratio error and phase angle error in current transformer(CT) depend critically on values of CT burden. Thus, precise measurement of CT burden is very important for the evaluation of CT. A method for the measurement of CT burden has been developed by employing the portable shunt precise resistor with negligible AC-DC resistance difference less than $10^{-5}$. The burden value(value and power factor) can be calculated from resistance and reactance obtained by measuring the change of ratio error and phase angle error caused by the change of shunt resistor. The uncertainty for the method is evaluated and found to be abut 2 %.

Design and FEM Analysis of Unipoled Disk-type Piezoelectric Transformer (Unipoled Disk-type 압전변압기의 설계 및 유한요소 해석)

  • Jung, Sung-Su;Park, Tae-Gone
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.04b
    • /
    • pp.183-186
    • /
    • 2004
  • Unipoled piezoelectric transformers were designed with different input and output area ratios. The voltage step-up ratio increased proportionally with increasing the input area. The piezoelectric transformers operated in each transformer's resonance vibration mode. In this paper, ANSYS(FEM program) was used for analysing piezoelectric transformers. We compared with analysis and experimental results. The voltage step-up ratio showed maximum value in output area of small size. Output characteristics of piezoelectric transformers with various size were simulated. The result of analysis showed 2~7 times higher voltage step-up ratio than a experiment result.

  • PDF

A Three-Winding Transformer Protective Relaying Algorithm Based on the Induced Voltages (유기 전압비를 이용한 3권선 변압기 보호계전 알고리즘)

  • 강용철;이병은
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.52 no.3
    • /
    • pp.173-178
    • /
    • 2003
  • This paper proposes a three-winding transformer protective relaying algorithm based on the ratio of the induced voltages (RIV). The RIV of the two windings is the same as the turn ratio for all operating conditions except an internal fault. For a single phase and a three-phase transformer containing the wye-connected windings, the induced voltages of the windings are estimated. For a three-phase transformer containing the delta-connected windings, the induced voltage differences are estimated using the line currents, because the winding currents are practically unavailable. The algorithm can identify the faulted phase and winding if a fault occurs on one phase of a winding. The test results clearly show that the algorithm successfully discriminates internal winding faults from magnetic inrush. The algorithm not only does not require hysteresis data but also can reduce the operating time of a relay.

Design and ANSYS Analysis of Disk-type Piezoelectric Transformer (디스크형 압전변압기의 설계 및 유한요소 해석)

  • Jung, Sung-Su;Park, Tae-Gone
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07b
    • /
    • pp.813-816
    • /
    • 2004
  • Unipoled piezoelectric transformers were designed with different input and output area ratios. The voltage step-up ratio increased proportionally with increasing the input area. The piezoelectric transformers operated in each transformer's resonance vibration mode. In this paper, ANSYS(FEM program) was used for analysing piezoelectric transformers. We compared with analysis and experimental results. The voltage step-up ratio showed maximum value in output area of small size. Output characteristics of piezoelectric transformers with various size were simulated. The result of analysis showed $2\sim7$ times higher voltage step-up ratio than a experiment result.

  • PDF

A Transformer Protective Relaying Algorithm Using the Ratio of Induced Voltages (유기전압비를 이용한 변압기 보호계전 알고리즘)

  • Kang, Y.C.;Lee, B.E.
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.49 no.10
    • /
    • pp.524-530
    • /
    • 2000
  • This paper presents a transformer protective relaying algorithm using the ratio of induced voltages. The proposed algorithm calculates primary and secondary voltage from currents and voltages of primary and secondary windings. The ratio of primary and secondary induced voltages is equal to the turn ratio in case of the steady state and magnetic inrush. On the other hand, the ratio is different form the turn ratio in case of internal winding faults. The algorithm does not require B-H curve and can reduce the relay's operating time.

  • PDF