• Title/Summary/Keyword: ratio transformer

Search Result 397, Processing Time 0.029 seconds

Electrical properties of Step -Down Multilayer Piezoelectric transformer sintered at $900^{\circ}C$ Low Temperature ($900^{\circ}C$ 저온에서 소결된 깅압용 적층 압전 변압기의 전기적 특성)

  • Lee, Kba-Soo;Yoo, Ju-Hyun;Kim, In-Sung;Song, Jae-Sung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.16-16
    • /
    • 2010
  • The multilayer piezoelectric transformer was manufactured using $Pb(Zn_{1/2}W_{1/2})O_3-Pb(Mn_{1/3}Nb_{2/3})O_3-Pb(Zr_{0.48}Ti_{0.52})O_3$ (abbreviated as PZW-PMN-PZT) ceramics and their electrical properties were investigated. The $k_{eff}$ of the input and the output calculated from the resonant and anti-resonant frequencies were 0.403 and 0.233, respectively. The voltage step-up ratio showed the maximum value in the vicinity of 81kHz. The multilayer piezoelectric transformer showed the temperature rise of about $36^{\circ}C$ at the output power of 12w.

  • PDF

Development of the Preventive Diagnostic Expert System of Gas in Oil for Power Transformer (변압기 예방진단을 위한 유중가스 전문가 시스템 구축 연구)

  • Choi, I.H.;Kweon, D.J.;Jung, G.J.;Sun, J.H.;Kim, C.G.;Kim, K.H.
    • Proceedings of the KIEE Conference
    • /
    • 1999.11d
    • /
    • pp.1019-1021
    • /
    • 1999
  • In this paper, we describe the design and appliance of the preventive diagnostic expert system of gas in oil for power transformer. This expert system is developed to use expert system development tool; Element Expert (NEURON DATA Inc.) Analysis is developed by four diagnose methods. In first, the standard of KEPCO is applied. It classifies the state of transformer by four level: Normal, warning, abnormal and danger. And the others are gas pattern methods, IEC code method, and Dornen & Roger Ratio method and applied later. These latter methods analyse the cause of result. Inference engine was designed with Element Expert. In last, we operate the system with sample data and we can obtain the correctly inferred result for the state of transformer.

  • PDF

Reduction Harmonics in Double Connected Modified Current Source Inverter by Switching Taps on Auto Transformer (단권변압기 탭 절환 방식에 의한 이중 접속 변형전류형 인버터의 고주파 저감)

  • 이공희;한우용
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.8 no.2
    • /
    • pp.69-76
    • /
    • 1994
  • An effective method for reducing the harmonics in double connected modified current source inverter[MCSI] by switching taps on auto transformer is presented in this paper. The proposed system operates as like a 24 step MCSI by adding only tap changing auxiliary circuit which consists of several taps and static switching elements to the 12 step multiple inverter, which is double connected three-phase six-step MCSI with an auto transformer. The basic theories of the proposed inverter systems for analyzing the output waveforms are described. And to optimize the effectiveness of the harmonic reduction, the optimum turn ratio and the tap changing control angle of auto transformer are decided by digital simulation and its validity is verified by experiment. Although the construction of the proposed inverter is very simple, it is clarified that the output waveform of the inverter is almost the same as that of the conventional 24 step multiple inverter under the optimum condition.

  • PDF

Numerical Algorithm for Power Transformer Protection

  • Park, Chul-Won;Suh, Hee-Seok;Shin, Myong-Chul
    • KIEE International Transactions on Power Engineering
    • /
    • v.4A no.3
    • /
    • pp.146-151
    • /
    • 2004
  • The most widely used primary protection for the internal fault detection of the power transformer is current ratio differential relaying (CRDR) with harmonic restraint. However, the second harmonic component could be decreased by magnetizing inrush when there have been changes to the material of the iron core or its design methodology. The higher the capacitance of the high voltage status and underground distribution, the more the differential current includes the second harmonic during the occurrence of an internal fault. Therefore, the conventional second harmonic restraint CRDR must be modified. This paper proposes a numerical algorithm for enhanced power transformer protection. This algorithm enables a clear distinction regarding internal faults as well as magnetizing inrush and steady state. It does this by analyzing the RMS fluctuation of terminal voltage, instantaneous value of the differential current, RMS changes, harmonic component analysis of differential current, and analysis of flux-differential slope characteristics. Based on the results of testing with WatATP99 simulation data, the proposed algorithm demonstrated more rapid and reliable performance.

Fault Diagnostic Expert System Using Dissolved Gas Analysis in Transformer (유중가스를 이용한 변압기 고장진단용 전문가 시스템 개발)

  • Jeon, Young-Jae;Yoon, Yong-Han;Kim, Jae-Chul;Yun, Sang-Yun;Choi, Do-Hyuk
    • Proceedings of the KIEE Conference
    • /
    • 1996.07b
    • /
    • pp.859-861
    • /
    • 1996
  • This paper presents the novel fault diagnostic expert system based on dissolved gas analysis(DGA) techniques in power transformer. The uncertainty of key gas analysis, norm threshold, and gas ratio boundaries are managed by using a fuzzy set concept. The uncertainty of rules are handled by fuzzy measures. Trend analysis through the monthly increment of key gas and DGA analysis are combined by the Dempster-Shafer theory, and the state of transformer and confidence factor are yielded by using this combined analysis. To verify the effectiveness of the proposed diagnosis technique, the expert system has been tested by using KEPCO's transformer gas records.

  • PDF

The Characteristics of Piezoelectric Transformer for Driving CCFL (CCFL 구동용 압전 변압기의 특성)

  • Jeong, Su-Hyun;Lee, Jong-Sub;Hong, Jong-Kuk;Chae, Hong-In;Yoon, Man-Soon;Lim, Kee-Joe
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.49 no.5
    • /
    • pp.259-264
    • /
    • 2000
  • In this paper, the characteristics of piezoelectric transformer is studied for driving CCFL(Cold Cathode Fluorescent Lamp). In order to investigate the effects of geometrical dimensions, λvibration-mode type piezoelectric transformers with different sizes in the length(l), width$(\omega)$ and thickness(t) are made of ceramics with PZT-PMWS compositions. The increases in temperature and aging effect are also measured in the transformer of PT-3 sample under the condition of operation continuously for 10 hrs. As the results of dimensional effects, the output power and voltage step-up ratio are largely affected by the ratio of length to thickness(l/t) rather than that of length to $width(l/\omega)$. The output power and step-up ratio are increased with increasing l/t. On case of PT-3, the output voltages are 510[Vrms] at 36[Vrms] in input voltage, $100[k\Omega]$ in load resistance. Temperature increases and variation of output voltages are $10[^{\circ}C]$ and less than 5[%], respectively.

  • PDF

Secondary Current Range Extension of Current Transformers by Using Two Different Current Transformers and Absolute Evaluation Technique (전류변성기 두 대와 절대 평가 기술을 이용한 2차 전류 범위 확장)

  • Kim, Yoon-Hyoung;Han, Sang-Gil;Jung, Jae-Kap;Han, Sang-Ok
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.58 no.1
    • /
    • pp.72-78
    • /
    • 2009
  • We have developed a current range extension method to obtain the ratio error and phase displacement of a current transformer (CT) by using absolute evaluation method and two different CTs. The method was applied to CTs under test with the current ratios in the range of 5,000 A / 1 A - 20,000 A / 1 A. The ratio error and phase displacement of the CT under test obtained in this study are consistent with those measured at the national institute in Germany using the same CT under test within an expanded uncertainty (k = 2) in the overall current ratios.

An Analysis on Surge Voltage Transfer Phenomena of Transformers by Minor Network (Minor netowrk에 의한 변압기의 충격전압파의 이행현상해석)

  • 이승원
    • 전기의세계
    • /
    • v.20 no.6
    • /
    • pp.7-18
    • /
    • 1971
  • Secondary-side transfer phenomena of primary-side surge voltage in concentric-cylindrical transformers of a high turn-ratio still present a problem in transformer insulation design even in the case of a neutral solid-grounding type. The conventional methods of analyzing them so far are much complicated for practical applications. Therefore, this paper describes a new approach to the analysis of secondary-side transfer phenomena of surge in concentric-cylindrical transformers of high turn-ratio and solid-grounding type. This generalized approach is thought to be more simple with the use of minor network concepts than the conventional one by major network only. The result shows that the secondary-side transfer phenomena of surge voltage could not be neglected even in concentric-cylindrical transformer of high turn-ratio and solid-grounding type, and will be satisfactorily applicable to the design of neutral-solid-grounding type transformers.

  • PDF

Soft-Switching Phase-shifted PWM Full-bridge Converter for high power applications (고전력 응용을 위한 소프트 스위칭 위상 천이 PWM 풀 브리지 컨버터)

  • 김영필;김태웅;한완옥;이성백
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2000.11a
    • /
    • pp.188-192
    • /
    • 2000
  • This paper presents a novel prototype of soft-switching PWM Full-bridge converter which incorporates active power switches in series with each rectifier diode in transformer secondary side. Switching and conduction losses of all the switches and devices are reduced as well as commutating current and circulating current flowing through transformer as compared with conventional converter. And duty ratio of primary switches is constant for maximum voltage conversion ratio. But this converter can be varied output by duty ratio of secondary switches. Operation principles basically the same as that of the PWM Full-bridge converter published previously. The operating characteristics of this converter are illustrate and discussed including the simulated analysis.

  • PDF