• Title/Summary/Keyword: ratio for remaining

Search Result 401, Processing Time 0.025 seconds

volution of massive stars in Case A binary systems and implications for supernova progenitors

  • Lee, Hunchul;Yoon, Sung-Chul
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.45 no.1
    • /
    • pp.70.4-71
    • /
    • 2020
  • One of the distinctive characteristics of the evolution of binary systems would be mass transfer. Close binary systems experience so-called Case A mass transfer during the main-sequence. We have performed calculations of the evolution of massive Case A (with the initial period 1.5 ~ 4.5 days) binary systems with the initial mass of 10 ~ 20 solar masses and mass ratio 0.5 ~ 0.95 using the MESA code. We find that in some systems, after the first mass transfer, the secondary stars evolve faster than the primary stars and undergo so-called 'reverse' mass transfer. Such phenomena tend to occur in relatively low-mass (initial mass < 16 solar masses) and close (initial period < 3 day) systems. Unless a system enters the common-envelope phase, the primary star would become a single helium star after the secondary star ends its life if the system were unbound by the neutron star kick. We find the various evolutionary implications of the remaining primary stars. In addition to the evolution into the compact single helium star progenitor, there is a possibility that the remaining primary star could evolve into a helium giant star, which could be a promising candidate for Type Ibn supernova progenitor, depending on the core mass. Further, we find that some primary stars satisfy the conditions for the formation of electron-capture supernova progenitor.

  • PDF

Effect of continuing dental care program by elementary school dental clinic in Gimcheon (김천시 초등학교 구강보건실 운영을 통한 계속구강건강관리사업 효과)

  • Choi, Ok-Sun;Kim, Hye-Jin;Jang, Sun-ju
    • Journal of Korean society of Dental Hygiene
    • /
    • v.15 no.4
    • /
    • pp.705-711
    • /
    • 2015
  • Objectives: The purpose of the study is to evaluate the effect of continuing dental care program by elementary school dental clinic in Gimcheon from 2008 to 2013. Methods: The subjects were experimental group of 152 students from three elementary schools having dental clinics and control group of 136 students from three elementary schools of no dental clinics. The six dentists in Gimcheon community health center carried out the regular dental checkups in the elementary schools and four dental hygienists recorded the dental examination results. After receiving WHO dental survey guideline education, the examiners used dental mirror and dental probe under the natural light. The contents of the survey included dental caries in the deciduous and permanent teeth, malocclusion, remaining ratio of sealant, treatment, and follow up. Results: DFT index by grade showed that 3.71 in experimental group and 4.56 in control group and it was remarkable in the 3rd grade. Thus. DFT index in the experimental group was lower than that of control group (p<0.05). DT index by grade was 0.63 in experimental group and 1.28 in control group marked in the 6th grade. DT index in the control group was higher than that of the experimental group (p<0,001). DFT index and DMFT Index by grade showed no significant difference between the control group and the experimental group. DFT and DMFT Index of the control group in the 3rd and 6th grade were lower score than those of experimental group. DFT and DMFT index in the third and 6th grade showed no significant difference between the control group and the experimental group. The remaining ratio of the sealant was 4.89 experimental group in the 6th grade. The remaining ratio of the sealant in the experimental group was higher than that in the control group. Conclusions: The continuing dental care program in the elementary school is very effective method in the treatment of oral disease in the elementary school children. The oral health care and prevention for the elementary school children should be implemented and carried out continuously.

Planning for Reasonable Construction and Expanding of Distribution Substation By Load Forecasting (부하예측에 의한 합리적인 배전용 변전소 증설계획 수립)

  • Choi, Sang-Bong;Kim, Dae-Kyeong;Jeong, Seong-Hwan;Bae, Jeong-Hyo;Ha, Tae-Hyun;Lee, Hyun-Goo;Kim, Ho-Yong
    • Proceedings of the KIEE Conference
    • /
    • 2000.11a
    • /
    • pp.92-94
    • /
    • 2000
  • This paper presents algorithm to plan construction and expanding of substation considering contingency accidents by proposing utilization factor according to configuration of substation bank system. In this paper, above all, proper sphere of supply area by each district which could be standardized with respect to its supply capacity is established under assumption of long term load forecasting which was made by district respectively, and then goal of utilization ratio based on configuration of substation bank was set to keep reliability by remaining sound bank when it happen to one bank accidents. Finally it is set up for optimal construction and expanding of substation considering economy and reliability simultaneously about substation to exceed these ratio.

  • PDF

Characteristics on the Output Coupled Type CVT Combined Differential Gear Unit (차동기어장치를 적용한 출력축 연결방식 무단변속기의 특성해석에 관한 연구)

  • Choi, Sang-Hoon;Kim, Yeon-Su
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.18 no.3
    • /
    • pp.205-215
    • /
    • 2001
  • Continuously variable transmission(CVT) mechanisms considered here combine the functions of a 2K-H I type differential gear unit and a V-belt continuously variable unit(CVU). One shaft of the V-belt CVU is connected directly to the differential gear unit and remaining shaft of it is linked to the output shaft. These mechanisms have many advantage which are the decrease of CVT size, the increase of overall efficiency, the extension of speed ratio range, and the generation of geared neutral. In this paper six different mechanisms of output coupled type CVT are proposed. Some useful theoretical formula related to speed ratio, power flow and efficiency are derived and analyzed, and theoretical analysis are proven by various experiments.

  • PDF

Could Urinary Copper/Zinc Ratio Be a Newer Tool to Replace 24-Hour Urinary Copper Excretion for Diagnosing Wilson Disease in Children?

  • Fahmida Begum;Khan Lamia Nahid;Tahmina Jesmin;Md. Wahiduzzaman Mazumder;Md. Rukunuzzaman
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.27 no.1
    • /
    • pp.53-61
    • /
    • 2024
  • Purpose: Although the 24-hours urinary copper excretion is useful for the diagnosis of Wilson disease (WD), there are practical difficulties in the accurate and timed collection of urine samples. The purpose of this study was to verify if the spot morning urinary Copper/Zinc (Cu/Zn) ratio could be used as a replacement parameter of 24-hours urinary copper excretion in the diagnosis of WD. Methods: A cross-sectional study was conducted at the Department of Pediatric Gastroenterology and Nutrition, Bangabandhu Sheikh Mujib Medical University (BSMMU), Dhaka, Bangladesh, from June 2019 to May 2021 on 67 children over three years of age who presented with liver disease. Twenty-seven children who fulfilled the inclusion criteria for WD were categorized into the test group, and the remaining forty children were considered to have non-Wilsonian liver disease and were categorized into the control group. Along with other laboratory investigations, spot morning urinary samples were estimated for the urinary Cu/Zn ratio in all patients and were compared to the 24-hour urinary copper excretion. The diagnostic value of the Cu/Zn ratio was then analyzed. Results: Correlation of spot morning urinary Cu/Zn ratio with 24-hours urinary copper excretion was found to be significant (r=0.60). The area under ROC curve with 95% confidence interval of morning urinary Cu/Zn ratio measured using 24-hours urine sample was 0.84 (standard error, 0.05; p<0.001). Conclusion: Spot morning urinary Cu/Zn ratio seems to be a promising parameter for the replacement of 24-hours urinary copper excretion in the diagnosis of WD.

Surgical Correction of Tetralogy of Fallot in Adults over 20 Years of Age (성인 20 세 이상 활로 4징증의 수술성적)

  • 정윤섭
    • Journal of Chest Surgery
    • /
    • v.23 no.2
    • /
    • pp.253-259
    • /
    • 1990
  • Between January, 1970 and August, 1989, a total of 81 patients whose age were more than 20 years of life, received total correction for tetralogy of Fallot. This report analyzed 70 patients among them and excluded the remaining 11 patients whose clinical data could not be found. Their mean age was 25.750.39 years[range 20 \ulcorner50]. The clinical manifestations were cyanosis and clubbing [64 pts], frequent URI[40 pts], anoxic spell [19 pts], infective endo-carditis[4 pts], brain abscess[3 pts], pulmonary tuberculosis[3 pts] and CHF, chest tightness, nephrotic syndrome, left hemiplegia, and tamponade. The types of right ventricular outflow tract obstruction were combined[46 pts], pure infundibular [21 pts] and pure valvular[3 pts]. Associated cardiovascular anomalies were PFO [27 pts], ASDi8 pts], LSVC[8 pts], aortic regurgitation [5 pts], right aortic arch, coronary artery anomalies, PDA and dextrocardia. Hospital mortality was 5.7%. The causes of death ware low cardiac output [2 pts], aggravation of CRF[1 pts] and brain damage[1 pts]. There was one late death because of residual intracardiac shunt and congestive heart failure. During the follow-up period, 16 patients were lost and the remaining 49 patients were asymptomatic and leading normal lives. Residual intracardiac shunt was detected in 5 patients with radionuclide single pass study but all of them had Qp / Qs ratio less than 1.5.

  • PDF

Hierarchical Dynamic Bandwidth Allocation Algorithm for Multimedia Services over Ethernet PONs

  • Ahn, Kye-Hyun;Han, Kyeong-Eun;Kim, Young-Chon
    • ETRI Journal
    • /
    • v.26 no.4
    • /
    • pp.321-331
    • /
    • 2004
  • In this paper, we propose a new dynamic bandwidth allocation (DBA) algorithm for multimedia services over Ethernet PONs (passive optical networks). The proposed algorithm is composed of a low-level scheduler in the optical network unit (ONU) and a high-level scheduler in the optical line terminal (OLT). The hierarchical DBA algorithm can provide expansibility and efficient resource allocation in an Ethernet PON system in which the packet scheduler is separated from the queues. In the proposed DBA algorithm, the OLT allocates bandwidth to the ONUs in proportion to the weight associated with their class and queue length, while the ONU preferentially allocates its bandwidth to queues with a static priority order. The proposed algorithm provides an efficient resource utilization by reducing the unused remaining bandwidth caused by the variable length of the packets. We also define the service classes and present control message formats conforming to the multi-point control protocol (MPCP) over an Ethernet PON. In order to evaluate the performance, we designed an Ethernet PON system on the basis of IEEE 802.3ah "Ethernet in the first mile" (EFM) using OPNET and carried out simulations. The results are analyzed in terms of the channel utilization, queuing delay, and ratio of the unused remaining bandwidth.

  • PDF

SINUS GRAFT AND VERTICAL AUGMENTATION OF MAXILLARY POSTERIOR ALVEOLAR RIDGE USING MANDIBULAR RAMAL BLOCK BONE GRAFT (상악동 골이식술과 하악지 자가골 블록을 이용한 상악 구치부 치조제 수직증강술)

  • Kim, Kyoung-Won;Lee, Eun-Young
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.32 no.3
    • /
    • pp.276-281
    • /
    • 2010
  • The maxillary posterior area is the most challenging site for the dental implant. After missing of teeth on maxillary posterior area due to periodontal problems, the remaining alveolar ridge is usually very thin because of not only pneumatization of maxillary sinus but also destruction of alveolar bone. The maxillary sinus bone graft procedure is one of the most predictable and successful treatments for the rehabilitation of atrophic and pneumatized endentulous posterior maxilla. But, in case of severe destruction of alveolar bone due to periodontal problems, very long crown length is still remaining problem after successful sinus graft procedures. We performed vertical augmentation of maxillary posterior alveolar ridge using mandibular ramal block bone graft with simultaneous sinus graft. After this procedures, we could get more favorable crown-implant ratio of final prosthodontic appliance and more satisfactory results on biomechanics. This is a preliminary report of the vertical augmentation of maxillary posterior alveolar ridge using mandibular ramal block bone graft with simultaneous sinus graft, so requires more long-term follow up and further studies.

A Study on Utilization Ratio and Operation of Transmission Lines (송전선로의 이용률 평가 및 합리적 운영에 관한 연구)

  • Kim, Dong-Min;Bae, In-Su;Cho, Jong-Man;Kim, Jin-O
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.55 no.10
    • /
    • pp.426-432
    • /
    • 2006
  • This paper describes the concepts of Static Line Rating (SLR) and Dynamic Line Rating (DLR) and the computational methods to demonstrate them. Calculation of the line capacity needs the heat balance equation which is also used for computing the reduced tension in terms of line aging. SLR is calculated with the data from the worst condition of weather throughout the year. Even now, the utilization ratio is obtained from this SLR data in Korea. DLR is the improved method compared to SLR. A process for DLR reveals not only improved line ratings but also more accurate allowed line ratings based on line aging and real time conditions of weather. In order to reflect overhead transmission line aging in DLR, this paper proposes the method that considers the amount of decreased tension since the lines have been installed. Therefore, the continuous allowed temperature for remaining life time is newly acquired. In order to forecast DLR, this paper uses weather forecast models, and applies the concept of Thermal Overload Risk Probability (TORP). Then, the new concept of Dynamic Utilization Ratio (DUR) is defined, replacing Static Utilization Ratio (SUR). For the case study, the two main transmission lines which are responsible for the north bound power flow in the Seoul metropolitan area are chosen for computing line rating and utilization ratio. And then line rating and utilization ratio are analyzed for each transmission line, so that comparison of the present and estimated utilization ratios becomes available. Finally, this paper proves the validity of predictive DUR as the objective index, with simulations of emergency state caused by system outages, overload and so on.

Analysis of Cell Performance with Varied Electrolyte Species and Amounts in a Molten Carbonate Fuel Cell

  • Lee, Ki-Jeong;Kim, Yu-Jeong;Koomson, Samuel;Lee, Choong-Gon
    • Journal of Electrochemical Science and Technology
    • /
    • v.9 no.2
    • /
    • pp.141-148
    • /
    • 2018
  • This study evaluated the performance characteristics of varied electrolyte species and amounts in a molten carbonate fuel cell (MCFC). Coin-type MCFCs were used at the condition of $650^{\circ}C$ and 1 atm. In order to measure the effects of varied electrolyte species and amounts, electrolytes of $(Li+K)_2CO_3$ and $(Li+Na)_2CO_3$ were selected and the amounts of 1.5 g, 2.0 g, 3.0 g, and 4.0 g were used. Insignificant performance differences were observed in the cell using different electrolytes, but the cell performance was sensitive to the amount of the electrolyte used. The pore-filling ratio (PFR), a ratio of pore filling in the components by the liquid carbonate electrolytes, was used to determine the optimum performance range. Consequently, 77% PFR demonstrated the optimum performance for both electrolytes. Thus, the MCFC had a permissible but narrow optimum performance range. The remaining amounts of electrolyte in the cells were determined using the weight reduction ratio (WRR) method after several hours of cell operation. The WRR used the relationship between the initial loaded amount of electrolyte and weight reduction of components in 10 wt% acetic acid. The relationships were linear and identical between the two electrolyte species.