• Title/Summary/Keyword: rating standard

Search Result 317, Processing Time 0.022 seconds

Anthropometric Characteristic of Female Student in Model Dpt. (모델 전공 여대생의 인체측정학적 특성)

  • Yoo, Young-June
    • Fashion & Textile Research Journal
    • /
    • v.9 no.4
    • /
    • pp.450-454
    • /
    • 2007
  • The purpose of this study was to offer objective information about standard of selecting and training fashion models by verifying anthropometric characteristics and comparing with general women. Total forty eight fashion models (M=20.08yr ; SD=1.7) were recruited by convenience sampling. Thirty eight items of participants were measured by manual of International Society for the Advancement of Kinanthropometric (ISAK). Mean and standard deviation of 38 items and also factor of somatotype (endomorph, mesomorph, ectomorph) were calculated. In the result, somatotype of fashion model was endomorphic ectomorphy, less muscle and taller height. Conclusionally, this study indicated that there is less mesomorphy rating related to muscle quantity, bone mass in somatoplot. However, it is necessary to provide the program enhancing the physical activity with model department.

Objective Measurement of Water Repellency of Fabric Using Image Analysis (I) - Methodology of Image Processing -

  • Jeong Young Jin;Jang Jinho
    • Fibers and Polymers
    • /
    • v.6 no.2
    • /
    • pp.162-168
    • /
    • 2005
  • A methodology for the objective evaluation of water repellency is studied using image analysis of the sprayed pattern on woven fabrics according to a standard spray test (AATCC Test Method 22-2001). The wet area ratio obtained from the spray standard test ranking is found to be exponentially related with its water repellency rating. Mean filtering is used to remove the effect of weave texture and the transmitted light through interyarn spaces. The ring frame of the instrument and wet region are recognized using Otsu thresholding technique. And Hough transform and outline operation are used to obtain the size and position of the ring frame. The objective assessment of the water repellency using image processing can reduce unnecessary confusion in the subjective determination of the water repellency.

Usability Evaluation Method for SOA Software (SOA 소프트웨어의 사용성 평가 방법)

  • Lee, Sang-Hyo;Yang, Hae-Sool
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.7
    • /
    • pp.1575-1584
    • /
    • 2009
  • Improvement of service quality and to be caused by with high re-use result expandability, the importance of SOA softwares to be coming to be high recently, according to the [thu] your (Gartner) group from 2006 until 2011 CAGR (yearly average complex growth rate: Compound it is a tendency where in Annual Growth Rate) these 35% the domestic and foreign SOA software markets are increasing suddenly at this degree. It follows hereupon and in about quality rating of SOA softwares the demand is augmented in about development of the quality rating method which it follows international standard. In order to evaluate the use characteristic quality of SOA softwares a quality and about the use frost requirement from the research which it sees and escape with the scale box it examined it measured and in about the method which it decides and an evaluation instance a research the result according to the standard which is appropriate it accomplished it presented. The research which it sees it leads and it induces strategic engineering development it leads and with the fact that it will be the possibility of raising an objectivity and an application degree it expects the use characteristic quality increase of SOA softwares.

Consensus on definition and quality standard of clinical practice guideline using RAND method (RAND 방법으로 합의한 임상진료지침의 정의와 질 평가 기준)

  • Ji, Seon-Mi;Kim, Soo-Young;Sheen, Seung-Soo;Heo, Dae-Seog;Kim, Nam-Soon
    • Health Policy and Management
    • /
    • v.20 no.2
    • /
    • pp.1-16
    • /
    • 2010
  • Background : Clinical practice guidelines are an increasingly familiar part of clinical practice. Moreover, rigorously developed evidence based guidelines has been widely used. However, in Korea, some of published documents as clinical practice guidelines have shown considerable disparity in structure, contents and quality. This is mainly because there is no consensus on the definition and quality standard of clinical practice guidelines. The purpose of this study was to draw consensus on the definition and the quality standard about clinical practice guidelines. Method : We developed a questionnaire about the definition of clinical practice guidelines with inclusion criteria(23 items) and the quality standard(30 items). We selected 9 experts who had prior experience in developing and implementing guidelines. Rating methods for appropriateness of items were adopted from the RAND method. Consensus was drawn in three rounds. Results : Of the 47 items agreed, 40 items were determined to be appropriate. Clinical practice guidelines were defined as "scientifically and systematically developed statements to assist practitioners and patients on making decisions about appropriate health care for specific clinical circumstances." Narrative reviews, systematic reviews or health technology assessment without recommendations, translation of foreign guidelines, guidelines for patients only and training manuals were not considered as clinical practice guidelines. For the quality standard of clinical practice guidelines, 27 items were deemed necessary. Conclusions : The consensus on the definition with inclusion criteria and the quality standard of clinical practice guidelines carries an important meaning as the first attempt to draw a general agreement in our society. The unique achievement of the consensus reflects the current status of clinical practice guidelines that there has been a high tendency to adapt foreign guidelines. We hope efforts of this kind will continue to bring improvement in clinical practice guidelines.

Automatic National Image Interpretability Rating Scales (NIIRS) Measurement Algorithm for Satellite Images (위성영상을 위한 NIIRS(Natinal Image Interpretability Rating Scales) 자동 측정 알고리즘)

  • Kim, Jeahee;Lee, Changu;Park, Jong Won
    • Journal of Korea Multimedia Society
    • /
    • v.19 no.4
    • /
    • pp.725-735
    • /
    • 2016
  • High-resolution satellite images are used in the fields of mapping, natural disaster forecasting, agriculture, ocean-based industries, infrastructure, and environment, and there is a progressive increase in the development and demand for the applications of high-resolution satellite images. Users of the satellite images desire accurate quality of the provided satellite images. Moreover, the distinguishability of each image captured by an actual satellite varies according to the atmospheric environment and solar angle at the captured region, the satellite velocity and capture angle, and the system noise. Hence , NIIRS must be measured for all captured images. There is a significant deficiency in professional human resources and time resources available to measure the NIIRS of few hundred images that are transmitted daily. Currently, NIIRS is measured every few months or even few years to assess the aging of the satellite as well as to verify and calibrate it [3]. Therefore, we develop an algorithm that can measure the national image interpretability rating scales (NIIRS) of a typical satellite image rather than an artificial target satellite image, in order to automatically assess its quality. In this study, the criteria for automatic edge region extraction are derived based on the previous works on manual edge region extraction [4][5], and consequently, we propose an algorithm that can extract the edge region. Moreover, RER and H are calculated from the extracted edge region for automatic edge region extraction. The average NIIRS value was measured to be 3.6342±0.15321 (2 standard deviations) from the automatic measurement experiment on a typical satellite image, which is similar to the result extracted from the artificial target.

Development and Validation of a Practical Instrument for Injury Prevention: The Occupational Safety and Health Monitoring and Assessment Tool (OSH-MAT)

  • Sun, Yi;Arning, Martin;Bochmann, Frank;Borger, Jutta;Heitmann, Thomas
    • Safety and Health at Work
    • /
    • v.9 no.2
    • /
    • pp.140-143
    • /
    • 2018
  • Background: The Occupational Safety and Health Monitoring and Assessment Tool (OSH-MAT) is a practical instrument that is currently used in the German woodworking and metalworking industries to monitor safety conditions at workplaces. The 12-item scoring system has three subscales rating technical, organizational, and personnel-related conditions in a company. Each item has a rating value ranging from 1 to 9, with higher values indicating higher standard of safety conditions. Methods: The reliability of this instrument was evaluated in a cross-sectional survey among 128 companies and its validity among 30,514 companies. The inter-rater reliability of the instrument was examined independently and simultaneously by two well-trained safety engineers. Agreement between the double ratings was quantified by the intraclass correlation coefficient and absolute agreement of the rating values. The content validity of the OSH-MAT was evaluated by quantifying the association between OSH-MAT values and 5-year average injury rates by Poisson regression analysis adjusted for the size of the companies and industrial sectors. The construct validity of OSH-MAT was examined by principle component factor analysis. Results: Our analysis indicated good to very good inter-rater reliability (intraclass correlation coefficient = 0.64-0.74) of OSH-MAT values with an absolute agreement of between 72% and 81%. Factor analysis identified three component subscales that met exactly the structure theory of this instrument. The Poisson regression analysis demonstrated a statistically significant exposure-response relationship between OSH-MAT values and the 5-year average injury rates. Conclusion: These analyses indicate that OSH-MAT is a valid and reliable instrument that can be used effectively to monitor safety conditions at workplaces.

Testing the Reliability of the Pain Color Circle Measurement Tool (색채동통척도의 신뢰도 연구)

  • 김주희
    • Journal of Korean Academy of Nursing
    • /
    • v.21 no.3
    • /
    • pp.339-348
    • /
    • 1991
  • The study problem was to determine the reliability of the Stewart pain circle measurement tool with Korean subjects. The purpose was to assess the tool for potential use in research in Korea. The subjects were 95 primary school students and 103 university students in Seoul. The study was conducted from May to June 1990, using Stewart's pain color circle tool. To determine the difference in the rated intensity of the order of the pain color circles, statistical mean and standard deviation were employed. Item reliability and test - retest reliability were used to test for reliability. ANOVA and t-test were used to explore for differences in the rated intensity of the order of the pain color circles according to the subjects' general characteristics. The findings were as follows ; 1. Higher level pain intensity was assigned to color circle numbers 2, 4, and 6 (These contain large amounts of color). Lower level pain intensity was assigned to numbers 1, 3, and 5(These contain small amounts of color). Higher and lower levels of pain intensity selection patterns were the same as Stewart's but the highest rating of pain was different. The highest pain intensity rating was given to the color red in this study instead of black as in Stewart's test. 2. University students and primary school students' ratings were not very difteferent. 3. Pain color circle reliability was $\alpha$=0.3468, Test - retest reliability was supported (t=0.02~0.97, p=0.337~0.988) 4. Differences in the rating of the pain intensity order were related to the subjects' age and sex, but not to religion. It was concluded that the pain color circle measurement tool is worth for further study as a research instrument with both Korean adult and child clients for validity and reliability.

  • PDF

Input LC Fiter Design of Diode Rectifiers Considering Filter VA Rating Reduction (필터소자의 용량 저감을 고려한 다이오드 정류기의 입력LC필터 설계)

  • 임영철;정영국
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.12 no.1
    • /
    • pp.35-44
    • /
    • 1998
  • In this paper, input LC filter design of diode rectifiers considering filter V A rating reduction has been propoesd. It consisted of an input LC parallel resonent tank whose inductor and capacitor values are se$.$ lected so that the input filter presents an infinite impedance to harmonic input ac current component. The operation of proposed input filter has been analyzed in detail under steady state conditions. Performance evaluation and related design data have been provided on Per Unit basis for the proper implementation of diode rectification system. Finally, Detailed input and output current analysis has shown that the proposed input filter yield high quality input ac current waveforms, in particular, high input power factor values and more reliabilty which reducing the V A rating of passive components as compared to the standard type LC filter.filter.

  • PDF

Individual Fit Testing of Hearing Protection Devices Based on Microphone in Real Ear

  • Biabani, Azam;Aliabadi, Mohsen;Golmohammadi, Rostam;Farhadian, Maryam
    • Safety and Health at Work
    • /
    • v.8 no.4
    • /
    • pp.364-370
    • /
    • 2017
  • Background: Labeled noise reduction (NR) data presented by manufacturers are considered one of the main challenging issues for occupational experts in employing hearing protection devices (HPDs). This study aimed to determine the actual NR data of typical HPDs using the objective fit testing method with a microphone in real ear (MIRE) method. Methods: Five available commercially earmuff protectors were investigated in 30 workers exposed to reference noise source according to the standard method, ISO 11904-1. Personal attenuation rating (PAR) of the earmuffs was measured based on the MIRE method using a noise dosimeter (SVANTEK, model SV102). Results: The results showed that means of PAR of the earmuffs are from 49% to 86% of the nominal NR rating. The PAR values of earmuffs when a typical eyewear was worn differed statistically (p < 0.05). It is revealed that a typical safety eyewear can reduce the mean of the PAR value by approximately 2.5 dB. The results also showed that measurements based on the MIRE method resulted in low variability. The variability in NR values between individuals, within individuals, and within earmuffs was not the statistically significant (p > 0.05). Conclusion: This study could provide local individual fit data. Ergonomic aspects of the earmuffs and different levels of users experience and awareness can be considered the main factors affecting individual fitting compared with the laboratory condition for acquiring the labeled NR data. Based on the obtained fit testing results, the field application of MIRE can be employed for complementary studies in real workstations while workers perform their regular work duties.

Application of Web-based Load Duration Curve System to TMDL Watersheds for Evaluation of Water Quality and Pollutant Loads (수질오염총량제도 유역의 수질 및 부하량 평가를 위한 웹기반 LDC 시스템의 적용)

  • Kang, Hyunwoo;Ryu, Jichul;Shin, Minhwan;Choi, Joongdae;Choi, Jaewan;Shin, Dong Seok;Lim, Kyoung Jae
    • Journal of Korean Society on Water Environment
    • /
    • v.27 no.5
    • /
    • pp.689-698
    • /
    • 2011
  • In South Korea, Total Maximum Daily Load (TMDL) has been enforced since 2004 to restore and manage water quality in the watersheds. However, the appraisal of TMDL in South Korea has lots of weaknesses to establish the plan for recovery of water quality because it just evaluates the target water quality during the particular flow duration interval. In the United States, Load Duration Curve (LDC) method bas been widely used in the TMDL to evaluate the water quality and pollutant loads considering variation of stream flow. In a recent study, web-based Load Duration Curve system was developed to create the LDC automatically and provide the convenience of use. In this study, web-based Load Duration Curve system was applied in the Gapyeongcheon watershed using the daily flow and 8-day interval water quality data, and Q-L Rating Curve was used to evaluate the water quality and pollutant load in the watershed, also. As a result of study, water quality and pollutant load in Gapyeongcheon watershed were met with water quality standard and allocated load in the all flow durations. Web-based Load Duration Curve system could be applied to the appraisal of South Korean TMDL because it can be used to judge the impaired flow duration and build up the plan of load reduction, and it could enhance the publicity. But, web-based Load Duration Curve system should be enhanced through addition of load assessment tools such as Q-L rating curve to evaluate water quality and pollutant load objectively.