• Title/Summary/Keyword: rate of absorption

Search Result 2,253, Processing Time 0.029 seconds

Study on CR/SAP Water Swellable Composite for Application of Functional Additives to Improve Water Absorption Rate

  • Seo, Eunho;Lim, Sungwook;Kang, Seungwan;Han, Dongbin;Park, Eunyoung
    • Elastomers and Composites
    • /
    • v.55 no.4
    • /
    • pp.314-320
    • /
    • 2020
  • This study focused on experiments with polyethylene glycol (PEG) and glycidyl methacrylate (GMA), which are functional additives for water-expandable rubber. Polychloroprene rubber (CR)/superabsorbent polymer (SAP) composites were prepared and their cure behaviors, mechanical properties, water absorption rates, and surface morphology were measured based on the functional additives applied. When PEG and GMA were applied to the composites, the water absorption rate increased-including the initial rate-compared to that measured when functional additives were not used. The results also show that PEG has a hydrophilic functional group, which allows it to absorb more water, and GMA acts as a coupling agent between CR and SAP. However, with the introduction of functional additives, the cure rate slowed down and the mechanical properties also decreased.

Characteristics of Absorption and Heat Transfer for Film Falling along a Vertical Inner Tube (3rd. Report, Refrigerating Capacity in Evaporator and Heating Capacity in Absorber) (수직관(수직관)내를 흘러내리는 액막식흡수기(液膜式吸收器)의 흡수(吸收) 및 열전달(熱傳達) 특성(特性) (제(第)3보(報), 증발기(蒸發器)의 냉동능력(冷凍能力)과 흡수기(吸收器)의 난방능력(暖房能力)))

  • Ohm, K.C.;Kashiwagi, Takao;Seo, J.Y.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.6 no.3
    • /
    • pp.175-181
    • /
    • 1994
  • This paper deals with the correlation of absorption rate in absorber and evaporation rate in evaporator. The evaporator consists of a copper tube of 10mm dia, and 600mm long and chilled water flowing through the tube is fed by the chilled water circulator. The flowrate of LiBr-water solution in the absorber plays a significant role in determining the magnitude of the heat transfer rate from chilled water to refrigerant There exists a flowrate of solution which has a maximum value of heat transfer. It is interesting to note that the absorption rate of absorber increases with increasing the heat transfer rate of the evaporator. Also, absorption rate increases with evaportation rate, and the ratio(the former/the other) depends on the inlet temperature of LiBr-water solution in the absorber. The heating capacity in the absorber is higher than the refrigerating capacity in the evaporator.

  • PDF

Causes of Cold Damage of Rice Plant and Its Control 1. Effects of Temperature on the Growth and Absorption of Mineral Nutrients (수도냉해의 발생기구와 그의 대책에 관한 연구 제1보 수도의 생장과 무기양분흡수에 미치는 온도의 영향)

  • 임형빈
    • Journal of Plant Biology
    • /
    • v.17 no.4
    • /
    • pp.31-37
    • /
    • 1974
  • Seedlings of Nongbaek representing strong cold tolerant variety of rice plant, Jinheung of medium variety and Tongil of weak variety were used respectively for the present study. These seedlings were water cultured in phytotron which maintained at the daytime and night temperature of 30-$25^{\circ}C$, 20-2$0^{\circ}C$, 20-15$^{\circ}C$ and 15-1$0^{\circ}C$. The growth rate of plant height, tillering rate, increase in dry weight and absorption pattern of important mineral nutrients at their early growth stage under each temperature conditions were observed. Generally, it appeared that Nongbaek was more active in the growth of plant height than Jinheung, and Jinheung was more active than Tongil under low temperature condition. The tillering rate of these three varieties was equally rapid while it was decreased in the order of weak cold tolerant variety, such as Tongil, Jinheung and Nongbaek as the temperature declined gradually. The dry weigh tincreasing curve showed almost the same pattern in the varieties at the treatment of each temperature. Under low temperature conditions, Nongbaek showed higher absorption rate of N per dry weight and higher absorption amount of per plant body, Jinheung followed and Tongil was the lowest. The absorption amount of P2O5 increased in the top part compared with the roots as temperature rose and decreased as temperature declined. There seemed to be no difference of absorption among the varieties which have different cold tolerance each other. Under low temperature the absorption rate of K per dry weight was high, as a whole, especially Nongbaek was markedly higher than the other two. The absorption rate of Ca, Mg and Fe was also equally high in all varieties under low temperature and Nongbaek showed a more absorptive tendency in the absorption amount under low temperature.

  • PDF

Analysis of Operation Parameters of Pilot-Scale Packed-Absorption System for Airborne Methyl Ethyl Ketone Control (공기 중 메틸에틸케톤 제어를 위한 Pilot-Scale 흡수 시스템의 운영인자 분석)

  • Jo, Wan-Kuen;Kim, Wang-Tae
    • Journal of Environmental Science International
    • /
    • v.20 no.4
    • /
    • pp.501-509
    • /
    • 2011
  • Unlike many laboratory-scale studies on absorption of organic compounds (VOCs), limited pilot-scale studies have been reported. Accordingly, the present study was carried out to examine operation parameters for the effective control of a hydrophilic VOC (methyl ethyl ketone, MEK) by applying a circular pilot-scale packed-absorption system (inside diameter 37 cm ${\times}$ height 167 cm). The absorption efficiencies of MEK were investigated for three major operation parameters: input concentration, water flow rate, and ratio of gas flow-rate to washing water amount (water-to-gas ratio). The experimental set-up comprised of the flow control system, generation system, recirculation system, packed-absorption system, and outlet system. For three MEK input concentrations (300, 350, and 750 ppm), absorption efficiencies approached near 95% and then, decreased gradually as the operation time increased, thereby suggesting a non-steady state condition. Under these conditions, higher absorption efficiencies were shown for lower input concentration conditions, which were consistent with those of laboratory-scale studies. However, a steady state condition occurred for two input concentration conditions (100 and 200 ppm), and the difference in absorption efficiencies between these two conditions were insignificant. As supported by an established gas-liquid absorption theory, a higher water flow rate exhibited a greater absorption efficiency. Moreover, as same with the laboratory-scale studies, the absorption efficiencies increased as water-to-gas ratios increased. Meanwhile, regardless of water flow rates or water-to-gas ratios, as the operation time of the absorption became longer, the pH of water increased, but the elevation extent was not substantial (maximum pH difference, 1.1).

Insulation Properties of Epoxy Resin to Elastomer Contents for Power Electrical Machine according to Moisture Absorption (전력기기용 탄성형 에폭시의 흡습에 따른 절연 특성)

  • Kim, Seok-Jae;Park, Seong-Hui;Jeon, Young-Sik;Kang, Seong-Hwa;Park, Dae-Hee;Lim, Kee-Joe
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.297-300
    • /
    • 2004
  • In this paper, we investigated insulation property of epoxy resin which includes elastomers to improve mechanical property, as varied to additive elastomer contents and to moisture absorption. There are four samples with 5[phr], 10[phr], 15[phr] and 20[phr]. we experimented to acquire insulation property(absorption rate, dissolution rate, apparent rate) and electrical property(perittivity, $tan\delta$, BDV) during respectively the time such as 6[h], 12[h], 18[h], 24[h] for moisture absorption. According to the experimental results, it is appeared that when the additive elastomer contents are increasing or when specimens remain more moisture, absorption rate, dissolution rate, permittivity and $tan\delta$ are slightly increasing but apparent rate and BDV(break-Down Voltage) strength are decreasing in particular, elastomer content [20]phr appeared remarkedly the more increase or decrease than others.

  • PDF

The Comparison of Absorption Characteristics between High Absorbent Polymers and Cellulose (고흡수성(高吸水性) Polymer와 Cellulose의 흡수특성(吸水特性) 비교(比較))

  • Yang, In;Ahn, Won-Yung
    • Journal of the Korean Wood Science and Technology
    • /
    • v.18 no.2
    • /
    • pp.36-48
    • /
    • 1990
  • This experiment was carried out to improve the quality of high absorbent polymer which has excellent absorptivity and water retention compared to pulp and absorption sheet, through absorption characteristics-absorptive power, water retention, absorption rate, gel strength, pH, particle size, and moisture content. - of six polymers, namely, anionic polyacrylamide, cationic polyacrylamide, polyacrylic, acid polyvinyle alcohol 500, and 1500, and a-cellulose. and to examine the possibility of substitution of amide groups for carboxyl group and/or hydroxyl group which were commercial high absorbent polymer by comparing the absorption characteristics of the polymers. Polyacrylamide has high absorptive power and water retention, but has low gel strength and poor absorption rate. The rest of polymers were similiar to ${\alpha}$-cellulose in every respect. Thus, polyacrylamides could be replaced with polyacrylic acid and polyvinyl alcohol which are presently a high absorbent polymers. In comparing the absorption characteristics and the absorptive power of the polymers-anionic polyacrylamide, cationic polyacrylamide, polyacrylic acid, polyvinyle alcohol. a-cellulose-the absorptive power was in inverse proportion to the gel strength and absorption rates, affected by the particle size and pH change.

  • PDF

An Experimental Study on Flow and Heat / Mass Transfer Characteristics of $LiBr-H_2O$ Solution Flowing over a Cooled Horizontal Tube (수평 냉각관 외부를 흘러내리는 $LiBr-H_2O$ 수용액의 유동 및 열/물질 전달 특성에 관한 실험적 연구)

  • Seal, Sin-Su;Lee, Sang-Yang
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.24 no.8
    • /
    • pp.1085-1096
    • /
    • 2000
  • An experimental study was performed to examine the heat and mass transfer characteristics of $LiBr-H_2O$ solution flowing over a single horizontal tube with the water vapor absorption. Effects of the flow rate and the temperature of the solution at the top of the tube, the absorber pressure and the drainage pattern were considered. The absorption rate depends highly on the absorber pressure at the low flow rate condition while on the solution inlet temperature at the high flow rate condition. Also, when the flow rate is low, the absorption performance with the sheet flow drainage appeared to be higher than that with the dripping/jet drainage. However, at the high flow rate condition, the case became reversed. The liquid film became wavy with the higher absorption rate. The waves were more probable to form with the lower flow rate and temperature of the solution, and with the higher absorber pressure.

Characteristics of Specific Absorption Rate (SAR) in Electromagnetic (EM) Dosimetry

  • Hwang, Sun-Tae;Choi, Kil-Oung
    • Journal of Radiation Protection and Research
    • /
    • v.25 no.2
    • /
    • pp.109-114
    • /
    • 2000
  • The SI unit of specific absorption rate (SAR) in W/kg in the electromagnetic (EM) field as non-ionizing radiation is exactly same as the SI unit of absorbed dose rate in Gy/s in the ionizing radiation field. The SI unit of both physical quantities can be expressed in $[m^{\cdot}s^{-3}]$. Where, the unit of absorbed dose, Gy stands for Gray. In EM biological interactions, the SAR equations are derived and the characteristics of EM field energy absorption in terms of the SAR are discussed and described on the mathematical basis.

  • PDF

Studies on the effect of various para-sympatholytic agents to the absorption of some sulfanamides (부교감신경차단성약물이 sulfa제의 흡수에 미치는 영향에 관한 연구)

  • 김재완
    • YAKHAK HOEJI
    • /
    • v.12 no.1_2
    • /
    • pp.16-31
    • /
    • 1968
  • Comparative studies were made on some sulfonamides, used individually and combined with parasympatholytic agents as regards (1) the absorption rate through isolated rat small intestine (in vitro), (2) the absorption rate through rat small intestine (in vivo), and (3) the blood concentration of sulfonamides were examined by its oral administration with each combined drug to rabbits, and the following effects were found, parasympatholytic agents inhibit the absorption of sulfonamides from the small intestinal tract. Comparison of the inhibitic efficiency of parasympatholytic agents is as follows: oxazepam, oxyphencyclimine hydrochloride, probantheline bromide, atropine sulfate (The examples are from the weakest to the strongest). Decrement of the absorption rate of sulfonamides is as follows: sulfadiazine, sulfathiazole, sulfamethoxypyridazine, sulfadimethoxine, sulfamerazine, sulfamethazine (The example are from the strongest to the weakest). Additionally, it is assumed that if the combined drugs were absorbed from the small intestine in the original form, those inhibitic effects should be best regarding to their sulfonamide per parasympatholytic agent combined rate "25:1" than to their any other rates.her rates.

  • PDF

The variation of water absorption rate and DC dielectric breakdown strength of Epoxy composites due to filler content (충진재 함량 변화에 따른 에폭시 복합재료의 흡수율과 직류 절연파괴강도의 변화)

  • Lee, D.J.;Kim, T.Y.;Shin, S.K.;Kim, M.H.;Kim, K.H.;Kim, J.H.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2349-2351
    • /
    • 1999
  • In this paper, the variable absorption rates and DC dielectric breakdown strength of epoxy composites were measured at boiling absorption condition in order to observe the influences of moisture in out door use. Also, in order to improve withstand voltage properties at moisture absorbtion condition. IPN (interpenetrating polymer network) method which had been already reported, was introduced and the influence was investigated. As a result, it was confirmed that the moisture absorption rate was increased and DC dielectric breakdown strength was degraded with boiling time and filler content increasing. On the other hand, it was confirmed that moisture absorption rate and DC dielectric breakdown strength degrading rate were lowered by the improvement of adhesion strength In IPN specimens.

  • PDF