• Title/Summary/Keyword: rate dependent

Search Result 3,171, Processing Time 0.031 seconds

Characteristics of flow rate according to design parameters of a shroud in outdoor unit (실외기 shroud 설계 인자에 따른 유량 특성)

  • Ryu, Ki-Jung;Kim, Min-Soo;Cha, Woo-Ho;Lee, Kwan-Soo
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.244-249
    • /
    • 2008
  • In this study, the characteristics of flow in outdoor unit were numerically analyzed. Parametric studies were performed to compare the effect of bell mouth height, fan height and fan width concerned with flow rate. The result indicated that the flow rate was dependent on the bell mouth height, while it was negligibly affected by the fan height and fan width. The fan width was found to affect the velocity distribution at heat exchanger face.

  • PDF

Development and Characterization of Membrane for Local Delivery of Cephalexin

  • Shin, Sang-Chul;Oh, In-Joon;Cho, Seong-Jin
    • Archives of Pharmacal Research
    • /
    • v.19 no.1
    • /
    • pp.1-5
    • /
    • 1996
  • Laminated films composed of drug-containing reservoir layer and drug-free membrane were prepared. Zero-order drug release with lag time was achieved by laminating drug-free film onto the reservoir layer, while burst effect was observed on cast-on film. The rate controlling membrane was either attached to or cast directly into the reservoir. The release rate was independent on the reservoir composition but dependent on the composition of rate-controlling membrane. In growth inhibitory test of cephalexin from Eudragit RS film to Streptococcus Mutans, the disk even after release test for 72 hours showed more bacterial growth inhibition than that of control. Permeation of drug through rat skin was proportional to the HPC fraction in the film. We could control the release of cephalexin from the film by changing the fraction of Eudragit RS, HPC and DEP content. Consequently, Eudragit RS/HPC film was found to be very effective system for local delivery of drugs.

  • PDF

A study on Emission Rates of VOCs from Conifers at Jeju Island (제주지역 주요 침엽수에서 배출되는 VOCs 배출특성)

  • Kim, Hyeong-Cheol;Lee, Ki-Ho
    • Journal of Environmental Science International
    • /
    • v.19 no.5
    • /
    • pp.627-637
    • /
    • 2010
  • Emission rate of monoterpene and isoprene was measured in five commonly growing tree species of conifers(Pinus thunbergii, Abies koreana, Cryptomeria japonica, Pinus densiflora, Chamaecyparis obtusa) at the Halla mountain sites. Dynamic flow enclosure technique was used and gas samples were collected into Tenax tube. The highest and lowest hourly emission rate was observed in Abies koreana (1.86 ${\mu}g$/gdw/hr) and Chamaecyparis obtusa (0.52 ${\mu}g$/gdw/hr), respectively. The major species of monoterpene from pine trees were ${\alpha}$-pinene, ${\beta}$-pinene, ${\beta}$-phellandrene, myrcene. Particularly, d-limonene was abundant in Abies koreana but ${\alpha}$-pinene, $d^3$-carene and sabinene was in Cryptomeria japonica. Emission rates of isoprene show less significant than those of monoterpene. And also seasonal emission rates of monoterpene were dependent on environmental factors such as temperature.

Vapor deposition of silicon nitride film on silicon and its electrical properties (실리콘질화막의 기상성장과 그 전기적 특성)

  • 성영권;민남기;김승배
    • 전기의세계
    • /
    • v.28 no.9
    • /
    • pp.43-50
    • /
    • 1979
  • Silicon nitride films were chemically deposited on silicon substrates by reacting SiCl$_{4}$ and NH$_{3}$ in a nitrogen atmosphere at 700~1100 .deg.C. The deposition rate increased rapidly with deposition temperature upto about 1000 .deg.C, and became less temperature dependent above this temperature. The etch rate of films in buffered HF solution decreased, with an increase of deposition temperature, and a heat treatment at a temperature higher than that of the deposition considerably reduced the etch rate. It indicates that the heat treatment resulted in a densification of the films. Surface charge density of 3~4 * 10$^{11}$ /cm$^{2}$ was determined from the C-V characteristics of MNS diode, and it was also found that surface charge density depended on deposition temperature, but not film thickness. The current-voltage characteristics displayed a logI-V$^{1}$2/ dependence in the temperature range of 300~500.deg.K. Measurement of the slope of this characteristics and its dependence on temperature and bias polarity suggest that conduction in sili con nitride films arises from the Poole-Frenkel mechanism.

  • PDF

Engine Fault Diagnosis Using Sound Source Analysis Based on Hidden Markov Model (HMM기반 소음분석에 의한 엔진고장 진단기법)

  • Le, Tran Su;Lee, Jong-Soo
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.39A no.5
    • /
    • pp.244-250
    • /
    • 2014
  • The Most Serious Engine Faults Are Those That Occur Within The Engine. Traditional Engine Fault Diagnosis Is Highly Dependent On The Engineer'S Technical Skills And Has A High Failure Rate. Neural Networks And Support Vector Machine Were Proposed For Use In A Diagnosis Model. In This Paper, Noisy Sound From Faulty Engines Was Represented By The Mel Frequency Cepstrum Coefficients, Zero Crossing Rate, Mean Square And Fundamental Frequency Features, Are Used In The Hidden Markov Model For Diagnosis. Our Experimental Results Indicate That The Proposed Method Performs The Diagnosis With A High Accuracy Rate Of About 98% For All Eight Fault Types.

The Effect of Synthetic Polymer Membranes on the Skin Permeation of Anti-AIDS Drugs (항에이즈 약물의 경피흡수에 미치는 합성고분자 멤브레인의 영향)

  • Lee, Kyung-Jin;Kim, Dae-Duk;Chien, Yie W.
    • Journal of Pharmaceutical Investigation
    • /
    • v.28 no.1
    • /
    • pp.1-5
    • /
    • 1998
  • The effect of synthetic polymer membranes on the permeation rate of dideoxynucleoside-type anti-HIV drugs through hairless rat skin was studied using ethylene/vinyl acetate copolymer (EVA) and ethylene/methyl acrylate copolymer (EMA) membranes fabricated by solvent casting method. In vitro skin permeation kinetics study of DDC (2',3'-dideoxythymidine), DDI (2',3'-dideoxyinosine) and AZT (3'-azido-3'-deoxythymidine) across the (membrane/skin) composite was conducted for 24 hours at $37^{\circ}C$ using the Valia-Chien skin permeation system. The results showed that skin permeation rate of each drug across the (skin/membrane) composite was mainly dependent on the property of the membrane. Proper selection of the polymeric membrane which resembles hydrophilicity/lipophilicity of the delivering drug was important in controlling the skin permeation rate.

  • PDF

Transdermal Permeation Characteristics of Anti Cholesterol Ointment using Nicotinic acid N-oxide (Nicotinic acid N-oxide를 이용한 항콜레스테롤 연고의 경피 투과 특성)

  • Jung, Duck-Chae;Kim, Kyu-Won
    • Journal of the Korean Applied Science and Technology
    • /
    • v.25 no.2
    • /
    • pp.123-129
    • /
    • 2008
  • Transdermal therapeutic system(TTS) is often used as the method of drug dosage into the epidermic skin. Natural polymer were selected as ointment material of TTS. We investigated the permeation of natural polymer ointment containing drug in rat skin using horizontal membrane cell model. Permeation properties of materials were investigated for water-soluble drug such as Nicotinic acid N-oxide in vitro. These results showed that skin permeation rate of drug across the composite was mainly dependent on the property of ointment base and drug. Proper selection of the polymeric materials which resemble and enhance properties of the delivering drug was found to be important in controlling the skin permeation rate. This result suggests a possible use of natural polymer ointment base as TTS of antihyperlipoproteinemic agent.

An Algorithm for Bit Error Rate Monitoring and Adaptive Decision Threshold Optimization Based on Pseudo-error Counting Scheme

  • Kim, Sung-Man
    • Journal of the Optical Society of Korea
    • /
    • v.14 no.1
    • /
    • pp.22-27
    • /
    • 2010
  • Bit error rate (BER) monitoring is the ultimate goal of performance monitoring in all digital transmission systems as well as optical fiber transmission systems. To achieve this goal, optimization of the decision threshold must also be considered because BER is dependent on the level of decision threshold. In this paper, we analyze a pseudo-error counting scheme and propose an algorithm to achieve both BER monitoring and adaptive decision threshold optimization in optical fiber transmission systems. To verify the effectiveness of the proposed algorithm, we conduct computer simulations in both Gaussian and non-Gaussian distribution cases. According to the simulation results, BER and the optimum decision threshold can be estimated with the errors of < 20% and < 10 mV, respectively, within 0.1-s processing time in > 40-Gb/s transmission systems.

A practical power law creep modeling of alloy 690 SG tube materials

  • Lee, Bong-Sang;Kim, Jong-Min;Kwon, June-Yeop;Choi, Kwon-Jae;Kim, Min-Chul
    • Nuclear Engineering and Technology
    • /
    • v.53 no.9
    • /
    • pp.2953-2959
    • /
    • 2021
  • A new practical modeling of the Norton's power law creep is proposed and implemented to analyze the high temperature behaviors of Alloy 690 SG tube material. In the model, both the stress exponent n and the rate constant B are simply treated as the temperature dependent parameters. Based on the two-step optimization procedure, the temperature function of the rate constant B(T) was determined for the data set of each B value after fixing the stress exponent n value by using the prior optimized function at each temperature. This procedure could significantly reduce the numerical errors when using the power law creep equations. Based on the better description of the steady-state creep rates, the experimental rupture times could also be well predicted by using the Monkman-Grant relationship. Furthermore, the difference in tensile strengths at high temperatures could be very well estimated by assuming the imaginary creep stress related to the given strain rate after correcting the temperature effects on the elastic modulus.

Identifying Factors Affecting Dental University Hospitals' Profitability (치과대학병원 수익성에 영향을 미치는 요인 분석)

  • Lee, Ji-Hoon;Kim, Seong-Sik
    • Korea Journal of Hospital Management
    • /
    • v.26 no.2
    • /
    • pp.17-26
    • /
    • 2021
  • Purposes: This study aims to identify factors affecting dental university hospitals' profitability and understand recent their business condition. Methodology: Data from 2016 to 2019 was collected from financial statement, public open data in 8 dental university hospitals. For the study, multiple regression test with stepwise selection was applied. Findings: First of all, 9 out of 19 independent variables were selected by stepwise selection. As a result of multiple regression test with selected independent variables and the dependent variable(operating profit margin ratio), the factors affecting hospitals' profitability were the number of dental unit chair, hospital location, debt ratio, total capital turnover ratio, employment cost rate, material cost rate, management expense rate, the number of patient per a dentist. Practical Implication: To improve dental university hospitals' profitability, hospitals specifically analysis and manage their cost such as employment, material and management cost and seek effectiveness by managing the proper number of patient per a dentist.