• Title/Summary/Keyword: rate dependent

Search Result 3,171, Processing Time 0.03 seconds

Nd:YVO4 Laser Patterning of Various Transparent Conductive Oxide Thin Films on Glass Substrate at a Wavelength of 1,064 nm

  • Wang, Jian-Xun;Kwon, Sang Jik;Cho, Eou Sik
    • Transactions on Electrical and Electronic Materials
    • /
    • v.14 no.2
    • /
    • pp.59-62
    • /
    • 2013
  • At an infra-red (IR) wavelength of 1,064 nm, a diode-pumped Q-switched $Nd:YVO_4$ laser was used for the direct patterning of various transparent conductive oxide (TCO) thin films on glass substrate. With various laser beam conditions, the laser ablation results showed that the indium tin oxide (ITO) film was removed completely. In contrast, zinc oxide (ZnO) film was not etched for any laser beam conditions and indium gallium zinc oxide (IGZO) was only ablated with a low scanning speed. The difference in laser ablation is thought to be due to the crystal structures and the coefficient of thermal expansion (CTE) of ITO, IGZO, and ZnO. The width of the laser-patterned grooves was dependent on the film materials, the repetition rate, and the scanning speed of the laser beam.

Effects of Rhythmic Hop on Response Times and Kicking Velocities of Taekwondo Kicks

  • Kim, Young-Kwan;Kim, Yoon-Hyuk
    • Korean Journal of Applied Biomechanics
    • /
    • v.24 no.4
    • /
    • pp.367-373
    • /
    • 2014
  • Most athletes execute rhythmic hop as a preparatory motion in Taekwondo sparring. The purpose of this study was to investigate the effect of rhythmic hop on the response times and kicking velocities of Taekwondo kicks. Twelve male elite Taekwondo athletes performed a roundhouse kick and a back kick as fast as possible immediately after seeing an external stimulus in rhythmic hop and in no hop, respectively. The three-dimensional marker data of the whole body were measured at sampling rate of 200 Hz. Paired t-tests were used to compare dependent measures between hop and no hop conditions. Results indicated that the rhythmic hop did not affect response time statistically but improved the kicking velocity significantly than no hop did. Different instants of detecting an external stimulus in rhythmic hop for the back kick showed significantly different response times. Conclusively, rhythmic hop is recommendable for the purpose of kicking velocity, but not for the purpose of response time. Athletes should be careful in executing rhythmic hop as their preparatory motions for the back kick, since the response time could be shortened or lengthened according to the instant of detecting an external stimulus.

Developement and application of Statistical Hydrofracturing Data Processing Program (통계적 접근법에 의한 수압파쇄 자료해석용 전산 프로그램 개발 및 적용)

  • 류동우;최성웅;이희근
    • Tunnel and Underground Space
    • /
    • v.6 no.3
    • /
    • pp.209-222
    • /
    • 1996
  • Shut-in pressure, reopenting pressure and fracture orientation are very important parameters to be evaluated precisely in in-situ stress measurement by hydraulic fracturing. Graphical methods on pressure-time curves have been conventionally used, even though these are seriously dependent on subjectivity of interpreters. So there have been many demands on new method to objectivity in determining parameters. We have developed integrated hydrofracturing data processing program (HYDFRAC), based on nonlinear regression analysis and can be invoked under the Window graphical user interface. HYDFRAC consiste of three routines, that is shut-in pressure routine, reopening pressure routine, and fracture delineation routine. Each of routines include independent modules according to parameter determination methods. Its application to field tests ensured both objectivity and facility in determining of hydraulic fracturing parameters. Determining shut-in pressures at each pressurization cycles, we adopted the exponential pressure-decay method(EPD method), the bilinear pressure-decay-rate method (PDR method), and the tangent intersection method in order to find the pressurization-cyclic tendency of shut-in pressures. The estimated pressure by PDR method exists in the range of the upper and lower values by EPD method, and lies near to the upper value more than the lower. Being the pressurization cycle increased, the range of upper and lower limits come to be stabilized gradually. By graphical superposition method and bilinear pressure-accumulated volume method, reopening pressures were determined. Vertical and inclined fracture attitudes were determined by applying the directional statistics and sinusoidal curve fitting, respectively. The results of evaluation of hydrofracturing parameters showed that statistical methods could enhance the objectivity better than graphical methods.

  • PDF

우위대마동맥을 이용한 관상동맥우회수술;임상적 및 혈관촬영에 의한 단기결과

  • 이현성;장병철;이성수;김재영;맹대현;박형동;윤영남;장양수
    • Journal of Chest Surgery
    • /
    • v.33 no.2
    • /
    • pp.151-159
    • /
    • 2000
  • background: The right gastroepiploic artery(RGEA) has been use in coronary artery bypass grafting from 1987. The RGEA is the most useful arterial conduit in coronary artery bypass grafting(CABG) followed by the internal mammary artery, Materials and method: From Septermber 1998 to February 1999 the RGEA was used for coronary artery bypass grafting in 11 patients 10 males and 1 female. Postoperative angiography was performed in all of the patients before discharge Result: Early patent rate of the RGEA was 100%. The flow competition of the REGA graft was seen in 4 patients(36.4%) The flow pattern war RGEA dependent type in the inner diameter of the recipient coronary artery 1.5 mm the inner diameter of the RGEA 2.5 mm and the rtio of inner diameter of the RGEA and the recipient coronary artery 1(p<0.05) Conclusion : Early results of CABG with RGEA was satisfactory. However the RGEA graft has a tendency of flow competition in relation to the inner diameter of graft. Preoperative angiographic evaluation for RGEA and meticulous operative technique are required for a good surgical results.

  • PDF

Studies on Antiulcer Effects of DA-9601, an Artemisia herba Extract against Experimental Gastric Ulcers and Its Mechanism (애엽추출물, DA-9601의 실험적 위궤양 모델에 대한 항궤양 효과 및 기전 연구)

  • 오태영;류병권;박정배;이상득;김원배;양중익;이은방
    • Biomolecules & Therapeutics
    • /
    • v.4 no.2
    • /
    • pp.111-121
    • /
    • 1996
  • Antiulcer effects of Artemisia herba extract (DA-9601) were evaluated in various types of experimental gastric ulcer induced in rats. And the effects of DA-9601 on mucus, basal and stimulated gastric acid secretion were also investigated in rats. DA-9601 (12.5∼400 mg/kg, p.o.) prevented the formation of gastric ulcers induced by 60% EtOH in 150 mM HC1, restraint water immersion stress, platelet activating factor (PAF), aspirin in 150 mM HCI with Pylorus-ligation and indomethacin. DA-9601 (4∼400 mg/kg, p.o.) significantly accelerated the healing rate of acetic acid-induced gastric ulcer and significantly stimulated mucus secretion in a dose-dependent manner. DA-9601 (20∼200 mg/kg, i.d.), however, did not inhibit basal gastric acid secretion in pylorus ligated rats and DA-9601 (200 mg/kg, i.d.) failed to influence histamine-, pentagastrin- and carbachol- stimulated gastric acid secretion. These results suggest that DA-9601 has inhibitory action on gastric lesion and ulceration through increasing mucus secretion in the stomach of rats without influencing basal and stimulated gastric acid secretion.

  • PDF

Opioid Receptor Selectivity and General Pharmacology of DK1001, New Alkaloid Analgesic (알칼로이드 진통제 DK 1001의 opioid 수용체 선택성 및 일반약리)

  • Kim, Jin-Sook;Kim, Dae-Kyung;Kwon, Tae-Hyub;Yong, Chul-Soon;Ha, Jeoung-Hee;Huh, Keon;Kim, Jung-Ae
    • Biomolecules & Therapeutics
    • /
    • v.7 no.3
    • /
    • pp.278-284
    • /
    • 1999
  • DK1001 is a thebain derivative, which is newly synthesized as an alkaloid analgesic. This study was designed to study effects of DK1001 on the ligands binding to the opioid receptor subtypes, and general pharmacology of DK1001. DK1001 inhibited the binding of [$^3H$]DAMGO, a selective mu-subtype agonist, to the opioid receptor of rat forebrain in a concentration-dependent manner. $EC_{50}$ of DK1001 was significantly lower than that of morphine. DK1001 inhibited the binding of 〔$^3$H〕DPDPE, a selective delta-subtype agonist concentration-dependently. DK1001(0.5 mg/kg) had no effects on behavior, body temperature, blood pressure. respiratory rate, and intestinal charcoal propulsion of mice. In addition, DK1001 did not affect on the contractilities of isolated muscle strips of aorta, ileum, and trachea of rats. These results suggest that DK1001 might be a potent analgesic without serious side effects.

  • PDF

Photokinesis of Cyanobacterium Synechocystis sp. PCC 6803

  • Chung, Young-Ho;Park, Young-Mok;Moon, Yoon-Jung;Lee, Eun-Mi;Choi, Jong-Soon
    • Journal of Photoscience
    • /
    • v.11 no.3
    • /
    • pp.89-94
    • /
    • 2004
  • Motile cyanobacterium Synechocystis sp. PCC 6803 cells show photomovement with respect to the light stimulus. Under lateral irradiation, Synechocystis displays a phototactic gliding movement toward the light source by a twodimensional random biased walk. Under vertical irradiation, Synechocystis decreased the frequency of mean vectorial gliding speed dependent on the applied fluence rate, whereas the deviation distribution width of the speed increased. This strongly suggests the involvement of photokinesis. Evidence for the cyanobacterial photokinesis was discussed in the previous report (Choi et al., 1999. Photochem. Photobiol. 70, 95-102) demonstrating that the gross scalar speed of vertically irradiating cells increased by about 50% compared with that of dark-adapted cells. In the visible wavelength range, Synechocystis cells showed a maximal photokinetic activity at 420 nm and a second maximal activity at 680 nm. The threshold action spectrum for the photokinesis resembles the absorption spectrum of chlorophyll with major differences in the phototaxis action spectrum at 560 nm and 660 nm. We postulate that the cyanobacterial photokinesis is powered by the energy-generating chlorophyll pigments.

  • PDF

A Case Study of Root Cause Analyses and Remedies for High frequency Vibration of Globe Valve in Nuclear Power Plant Piping System (원자력 발전소 배관계 글로브 밸브의 고주파 진동 원인 분석 및 해결 사례)

  • Choi, Byoung-Hwa;Park, Soo-Il;Cheon, Chang-Bin
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11a
    • /
    • pp.394-399
    • /
    • 2005
  • A case history is presented pertaining to high frequency piping vibration and noise caused by globe valve in the spent fuel pool cooling system of nuclear power plant. Frequency analyses were performed on the system to diagnose the problem and develop a solution to reduce the piping vibration and noise. The source of the high frequency and noise energy was traced to the globe valve located immediately downstream of the centrifugal pump by performing valve throttling test. Measurements of vibration and noise are presented to show that the high frequency vibration and noise amplitude was dependent upon the valve disc position and flow rate. Strouhal vortex shedding frequencies were generated at the exit of the globe valve which exited structural resonance of valve disc and amplified the high frequency vibration and noise. The problem was identified as an interaction between the flow inside globe valve and the valve disc structure. Attempts to reduce the vibration and noise amplitudes of the piping system were successfully achieved by the modification of guide-disc diameter and disc-edge figure The valve disc was replaced by an alternative to eliminate the source of the harmful high frequency vibration and noise.

  • PDF

Expression of Microsatellite Instability (MSI) from Colorectal Carcinoma Patients

  • Lee, Jae Sik
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.46 no.2
    • /
    • pp.59-63
    • /
    • 2014
  • The death toll of Colorectal Carcinoma in Korea was 1,826 and 7,721 in the years 1992 and 2011, respectively. This rate of increase was shown to be more than 4.23 times higher than that of any other form of cancer. Therefore, Colorectal Carcinoma requires various diagnostic methods, and Microsatellite Instability (MSI) was applied as a new diagnostic tool. From this study with several microsatellite markers, only marker #13 was detected and observed D13S160 13% (4/30), D13S292 13% (4/30), D13S153 10% (3/30) in order. From the results of amplication with microsatellite marker, D13S292 37% (11/30), D13S153 33% (10/30), D13S160 33% (10/30) in order were shown. The appearance of a genetic mutation, which depends on the loci of Colorectal Carcinoma, was shown amplication from rectal cancer (3.77) which was higher than that of right Colorectal Carcinoma (2.08) (p<0.018). The genetic mutation with lymph node (4.13) appeared higher than normal (1.93) (p<0.001). There were no great differences in the genetic mutation dependent on disease, histological classification and increased group of serum CEA. Accordingly, it is suggested that the correct primers, which can evaluate MSI well from colorectal carcinoma, should be chosen and that MSI be considered a good prognosis and quality control tool.

Comparison of Developmental Efficiency of Murine Somatic Cell Nuclear Transfer Protocol

  • Moon, Jeonghyeon;Jung, Miran;Roh, Sangho
    • Journal of Embryo Transfer
    • /
    • v.32 no.3
    • /
    • pp.81-86
    • /
    • 2017
  • The Somatic cell nuclear transfer (SCNT) method can be applied to various fields such as species conservation, regenerative medicine, farming industries and drug production. However, the efficiency using SCNT is very low for many reasons. One of the troubles of SCNT is that it is highly dependent on the researcher's competence. For that reason, four somatic cell nuclear injection methods were compared to evaluate the effect of hole-sealing process and existence of cytochalasin B (CB) on efficiency of murine SCNT protocol. As a results, the microinjection with the hole-sealing process, the oocyte plasma membrane is inhaled with injection pipette, in HCZB with CB was presented to be the most efficient for the reconstructed in SCNT process. In addition, we demonstrated that the oocytes manipulated in Hepes-CZB medium (HCZB) with CB does not affect the developmental rate and the morphology of the blastocyst during the pre-implantation stage. For this reason, we suggest the microinjection involving hole-sealing in HCZB with CB could improve SCNT process efficiency.